TL 1. Vds Certification - fcs-8000-Vfd-b - Aviotec Ip Starlight-Đã G P
TL 1. Vds Certification - fcs-8000-Vfd-b - Aviotec Ip Starlight-Đã G P
MECHANICAL
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following tests on electrical/electronic control modules:
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3305.01
Valid to November 30, 2025
Revised October 21, 2024
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
ELECTRICAL (EMC)
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following automotive electromagnetic compatibility tests:
*Automotive Electrical Tests of the following types: GMW3172 (2010, 2012, 2014, 2015, 2018,
-Point Functional/Parametric Check 2023);
-Jump Start ISO 16750-2 (2010, 2012, 2023)
-Reverse Polarity
-Over Voltage
-Discrete Digital Input Threshold Voltage
-Crank Pulse Capability and Durability
-Power Supply Interruptions
-Battery Voltage Dropout
-State Change Waveform Characterization
-Ground Path Inductance Sensitivity
-Parasitic Current
-Sinusoidal Superimposed Voltage
-Pulse Superimposed Voltage
-Battery Line Transients
-Ground Offset
-Open Circuit – Single Line Interruption
-Open Circuit – Multiple Line Interruption
-Power Offset
-Over Load – All Circuits
-Over Load – Fuse Protected Circuits
-Multiple Power and Multiple Ground Short Circuits
Including Pass Through
-Intermittent Short Circuit to Battery and to Ground
-Switched Battery Lines
-Continuous Short Circuit to Battery and to Ground
for Input/Output
- AutoStart Voltage Transient
Electrostatic Discharge (ESD) ISO 10605 (2001, 2008, 2023)
Conducted Emissions CISPR 25 (2002, 2008), Sections 6.2 & 6.3;
CISPR 25 (2016, 2021), Sections 6.3 & 6.4
*Using the above customer supplied test methods and specifications, directly related to the test
technologies and equipment parameters listed above.
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3305.02
Valid to November 30, 2025
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MECHANICAL
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following dimensional testing:
I. Dimensional Testing
FOV :
75 mm 3D Scanner
125 mm
250 mm
350 mm
Up to (20 x 200) mm
Up to (20 x 200) mm
Up to (20 x 200) mm
Up to 50 mm Digital Indicator
Up to 25 mm Digital Micrometer
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3305.03
Valid to November 30, 2025
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3305.03
Valid to November 30, 2025
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Building Technologies
12 th February 2025
Dear partners,
This report presents the test results of the AVIOTEC 8000i IR (Model: FCS-8000-VFD-I), conducted
in accordance with VdS Guideline 3847 as part of the certification process. The tests were performed
to verify compliance with the required fire detection performance and environmental standards. Below
is a summary of the test results:
Environmental class II
6.15 Vibration, sinusoidal Frequency range: (10 to 150) Hz
(operational) - Test FC Acceleration amplitude:
☒
according to IEC 60068-2- 5 m/s2 (≈0,5 gn)
6:1995 Number of axes:3 / Sweep rate: 1 octave/min
Number of sweep cycles: 1/axis
Environmental class II:
6.16 Vibration, sinusoidal Frequency range: (10 to 150) Hz
(endurance) - Test Acceleration amplitude:
☒
according to EN 60068-2- 10 m/s2 (≈1,0 gn)
6:2008 Number of axes:3 / Sweep rate: 1 octave/min
Number of sweep cycles: 20/axis
The specimen shall be connected to the supply and
6.17 Displacement of the monitoring equipment and focused
FOV (option with on a fixed image area. Then the alignment of the specimen ☒
requirements) is changed manually according to the manufacturer’s
specifications.
The specimen shall be connected to the supply and
monitoring equipment. Then the response behaviour of the
test specimen shall be measured at the upper and lower
6.18 Variation in supply limit
☒
parameters (operational) values of the range of supply parameters (e.g. voltage)
specified by the manufacturer in
accordance with the test method described in section
6.1.3.
Using the devices and test methods the following EMC
immunity tests must be performed:
a) Mains supply voltage variations — if the VCD
6.19 Electromagnetic incorporates a mains supply;
compatibility (EMC), b) Mains supply voltage dips and short interruptions — if
immunity tests the VCD incorporates a mains supply;
☒
(operational) according to c) Electrostatic discharge;
EN 50130-4:2011 + A1 d) Radiated electromagnetic fields;
:2014 e) Conducted disturbances induced by electromagnetic
fields;
f) Fast transient bursts;
g) Slow high-energy surge voltages.
Building Technologies
Video-based fire detection is the system of choice The cameras have a powerful, embedded processor
when reliable video motion fire detection is needed. with dedicated hardware to support advanced
It operates as stand-alone unit and does not need a machine learning and deep neural networks.
separate evaluation unit. Subject to the installation AVIOTEC 8000i IR allows easy configuration and
and operating conditions explained in the monitoring through network devices such as Client
documentation, it can, for example, supplement PCs or mobile devices. A video recording
traditional fire detection systems or provide means management system may be integrated optionally.
of fire detection where traditional fire detection Furthermore, there is a relay output to transmit
systems are technically limited. alarm signals, e.g. to the AVENAR panel. In this case
AVIOTEC 8000i IR can be used as primary fire the camera acts as supervisory signal-initiating
detection system when the application is not covered device. Alarms have to be verified by an operator in a
by any code of practice or other kind of standards or monitoring center owing to non-existing standards.
if the necessary approvals/releases have been Automatic alarm-forwarding to fire services is not
obtained for the intended applications in accordance provided.
with the applicable laws and other regulations.
The FCS-8000-VFD-I is an extremely robust bullet Functions
camera for mission-critical applications. The Fast and reliable flame and smoke detection
ruggedized and stable design has exceptional The smoke and flame algorithm analyzes video
corrosion resistance for use in any outdoor frames by means of characteristic spatio-temporal
application. patterns and variables. The core of the detection
Using 1/1.8" sensors with 4MP resolution, the algorithm is a Deep Learning Network which was
FCS-8000-VFD-I provides the perfect balance trained on a large-scale internal database, which is
between high resolution and extreme low light representative of the use cases of a Video-based Fire
sensitivity. Detection System. The fast detection algorithm is
Starlight X technology combined with powerful smart based on a real-time image processing on the camera
IR illumination ensure highly detailed images even in firmware.
the most challenging situations.
Fire Alarm Systems - FCS-8000-VFD-I AI-VFD Bullet 4MP 4.4-10mm IP67 2|7
The video-based fire detection works under The camera is capable of delivering high-quality and
remarkable low-light performance (down to 1 or 0 lx high-resolution video with low network load.
with the internal IR illumination) and detects test With a doubling of encoding efficiency, H.265 has
fires TF1 to TF8. In case of flame or smoke detection become the new compression standard of choice for
the video broadcast has the advantage to verify the IP video surveillance systems.
alarm, speed up the rescue chain and give insights to
Resists rain, dust, and tampering with reliable
rescue teams.
operation across a wide temperature range
Monitoring large areas Suitable for indoor and outdoor usage.
Insensitive to dust and humidity thanks to the optical The robust design of the camera is rated to IP66 /
principle, it is possible to monitor large indoor and IP67 and IK10 standards, safeguarding the camera
sheltered outdoor areas that push conventional against rain and dust while also offering protection
systems to their limits. AVIOTEC 8000i IR is the against vandalism and tampering.
innovative solution for: The camera can operate in a wide ambient
• Industry temperature range between -50 °C up to +60 °C.
• Transportation Easy installation
• Energy & Utilities The FCS-8000-VFD-I uses the proven 3-step
• Warehouses installation concept. The mounting plate has multiple
hole patterns for installation. The back box can be
Large application range
attached with a simple rotate and click. All wires can
The video-based fire detection is suitable for a range
be connected in the back box.
of challenging applications in harsh environments
Power can be supplied through Power-over-Ethernet.
with a high fire hazard like paper mills. Highly
With this configuration, only a single cable
versatile in application, AVIOTEC 8000i IR offers the
connection is required to view, power, and control
possibility to complement existing systems or to tap
the camera. Using PoE makes installation easier and
into new application fields.
more cost effective, as cameras do not require a
Individually adjustable and adaptable local power source.
Verification time, sensitivity, detection size and The design of the camera focuses on robustness and
selective masking for smoke and flame are stability. A patented optimized swivel design further
individually configurable to adjust them to the helps with the ease of installation.
customer needs. Flame and smoke detection can be The swivel has a big-ball joint for optimal stability.
activated or deactivated separately. When combined with electronic image stabilization,
this helps to ensure stable images in challenging
Root cause analysis
environments, such as traffic monitoring.
Connecting the camera to a video management
The camera features a short housing and a big
system offers the possibility to find out the cause of
swivel, to ensure maximum stability.
fires. Based on video recordings, incidents can
carefully be established and evaluated. This helps Advanced edge recording
eliminating and preventing hazardous situations in Advanced edge recording provides the storage
the future. solution possible due to the combination of the
following functionalities:
Starlight X - Next level starlight performance
Starlight X technology combines the latest high • Dual microSD cards that can be set up as either:
performance, large pixel sensors, optics, improved – Mirrored, for redundant storage
image processing and noise suppression, resulting in – Failover, for extended service intervals
a 5.5x improved sensitivity compared to the standard
starlight camera. – Extended, for maximum retention time
• Industrial microSD card support allows for
IR illumination extreme lifetime
The camera offers integrated advanced intelligent IR
• Health monitoring of industrial microSD cards
illumination. The IR range covers a distance of up to
provide early service indications
80 m (262 ft).
The combination of multiple IR beam angles, linked Cloud-based services
to the zoom position of the lens, ensure uniform The camera supports time-based or alarm-based
illumination of the full scene, without hot spots or JPEG posting to four different accounts. These
dark corners in any field of view. Intelligent IR accounts can address FTP servers or cloud-based
ensures a balanced image without over exposure on storage. Video clips or JPEG images can also be
objects closer to the camera. exported to these accounts.
Alarms can be set up to trigger an e-mail or SMS
H.265 high-efficiency video encoding
notification so you are always aware of abnormal
The camera is designed on the most efficient and
events.
powerful H.264 and H.265/HEVC encoding platform.
Fire Alarm Systems - FCS-8000-VFD-I AI-VFD Bullet 4MP 4.4-10mm IP67 3|7
Environmental EN 50130-5 (Class IV) IMPORTANT: Video fire indication systems are video
content analysis systems. They give indications for
EN 60068-2-2 possible fires and are designed to supplement fire
EN 60068-2-5 detection systems and human guards in monitoring
EN 60068-2-6 centers in order to recognize possible dangerous
situations.
EN 60068-2-18
Video fire indication systems are confronted with a
EN 60068-2-27 higher amount of challenges considering scenery and
EN 60068-2-30 background compared to conventional fire detection
systems. They cannot ensure that fire will be
EN 60068-2-42
detected reliably in all scenery settings. Thus, the
EN 60068-2-52 video fire detection system shall be seen as a
EN 60068-2-75 support system that enhances the probability of early
fire detection, with the restriction that it shall not be
EN 60068-2-78
seen as a system that ensures fire detection in all
TS 2-2003, Section 2 (Environmental require- possible image scenarios and it might detect false
ments) alarms. Conventional fire alarm systems must in no
EN IEC 63000 (RoHS) way be replaced by video-based fire alarm systems.
California Proposition 65
In addition, and for the U.S. market only, Bosch
Security Systems makes no representation that the
Corrosion resistance ISO 14993
video fire indication system will prevent any personal
injury or property loss by fire or otherwise; or that
Safety IEC 62368-1
such product will in all cases provide adequate
EN 62368-1 warning or protection. Buyer understands that a
UL 62368-1 properly installed and maintained fire indication
system may only reduce the risk of a fire or other
CSA C22.2 No. 62368-1
events occurring without providing an alarm, but it is
IEC 60950-22 not insurance or a guarantee that such will not occur
EN 60950-22 or that there will be no personal injury or property
UL 60950-22 loss as a result.
1 Grommet (IP66)
1 Grommet (IP67)
3 Installer UX labels
Technical specifications
Electrical
Algorithm Overview
Dimensions in mm (inch) Min. detection size for Smoke, standard setting 1.6
(% of picture width)
0.3m 11.4m 13.6m 23.6m 30.2m Max. illumination level for flame detection (lx) 20,000
0.5m 19.0m 22.7m 39.3m 50.4m
0.3m 7.8m 9.3m 16.2m 20.8m Input voltage (VAC) 24 VAC ±10%
0.5m 13.1m 15.6m 27.0m 34.6m
0.75m 19.6m 23.4m 40.5m 52.0m Input voltage (VDC) 12 VDC – 26 VDC ±10%
1m 26.2m 31.2m 54.1m 69.3m
1.25m 32.7m 39.0m 67.6m 86.7m Power consumption PoE (W) (typ- 7 W – 12.95 W
1.5m 39.3m 46.8m 81.1m 104.0m ical – maximum)
For further information refer to user manual and Power consumption VAC (W) (typ- 7.10 W – 13 W
planning manual on: https://www.boschsecurity.com ical – maximum)
1 FCS-8000-VFD-I
Fire Alarm Systems - FCS-8000-VFD-I AI-VFD Bullet 4MP 4.4-10mm IP67 5|7
Illumination intensity Manually adjustable; Intelligent in- Display stamping Name; Logo; Alarm message; Time
tensity
Storage
Firmware
Internal storage 5-s-pre-alarm-recording
Common Product Platform CPP14
Memory card slot Dual micro SDHC; Dual micro SDXC;
Video streaming Dual micro SD card up to 2 TB
Video compression H.264 (ISO/IEC 14496-10); M- Industrial SD cards Extreme lifetime and health monitor-
JPEG; H.265/HEVC ing support that provides early ser-
vice indication
Fire Alarm Systems - FCS-8000-VFD-I AI-VFD Bullet 4MP 4.4-10mm IP67 6|7
Dual SD-card slot configurations Mirror (redundant storage); Failover no-ip.com); SMTP; iSCSI; UPnP
(extended service interval); Extend (SSDP); DiffServ (QoS); LLDP;
(maximum retention time); Auto- SOAP; CHAP; Digest authentication
matic Network Replenishment
Ethernet type 10/100BASE-T
Inputs and outputs
Conformity ONVIF Profile S; ONVIF Profile G;
Ethernet Shielded RJ45; ONVIF Profile T; ONVIF Profile M
Punch down connector
Data security
Audio line in 10 kOhm typical; max. 1 Vrms
Crypto coprocessor (TPM) RSA 4096 bit; AES/CBC 256 bit
Audio line out 1.5 kOhm typical; 1 Vrms
PKI X.509 certificates
Alarm inputs 2;
Dry contact; End-to-end encryption Full end-to-end with supported VMS
5 - 40 VDC;
2.2 K end-of-line resistor Encryption TLS 1.2; TLS 1.0; TLS 1.1; AES
256; AES 128; TLS 1.3
Alarm outputs 2
max 30 VAC; Local storage encryption XTS-AES
+40 VDC;
0.5 A; Video authentication MD5; SHA-1; SHA-256; Checksum
continuous 10 VA
Firmware protection Signed firmware; Secure boot
Power output 12 VDC, max 50mA
Mechanical
Surge protection 1 kV; 1 kA to ground (8/20 μs)
Material Housing: Aluminum with dehumidify-
USB USB 2.0 Type C, for use with wire- ing membrane and waterproof con-
less USB dongle for setup and com- nection area
missioning (sold separately)
Dimensions (Ø x H) (mm) 148 mm x 115 mm
Fiber optics (sold separately) The Fiber Optic Ethernet Media Con-
verter kit (VG4-SFPSCKT) installed Weight (kg) 2.95 kg
inside a Surveillance Cabinet
(NBA-7070-PA0, NBA-7070-PA1 or Color in RAL RAL 9003 Signal white
NBA-7070-PA2) provides the fiber
optic interface to the mounted cam- Mounting type Surface-mounted
era
Environmental
Audio
Operating temperature (°C) -40 °C – 60 °C PoE;
Compression and sampling rate AAC-LC 48kbps 16 kHz -50 ºC — 60 ºC 12 VDC/24VAC;
Up to 74 ºC according to NEMA TS
Minimum signal-to-noise ratio (dB) >50 dB 2-2003 (R2008), para 2.1.5.1 us-
ing fig. 2.1 test profile
Audio streaming Full duplex; Half duplex
Storage temperature (°C) -40 °C – 70 °C
Network
Cold start temperature (°C) -40 °C
Protocols / standards IPv4; IPv6; UDP; TCP; HTTP; HTTPS;
RTP/RTCP; IGMP V2/V3; ICMP; Operating relative humidity, non- 5% – 93%
ICMPv6; RTSP; FTP; ARP; DHCP; condensing (%)
APIPA (Auto-IP, link local address);
Operating relative humidity, con- 5% – 100%
NTP (SNTP); SNMP (V1, MIBII);
densing (%)
SNMP (V3, MIBII); DNS; DNSv6;
DDNS (DynDNS.org, selfHOST.de, Storage relative humidity (%) 0% – 98%
Fire Alarm Systems - FCS-8000-VFD-I AI-VFD Bullet 4MP 4.4-10mm IP67 7|7
Ordering information
Accessories
NDA-U-PMAL Pole mount adapter large
Universal pole mount adapter, white; large
Order number NDA-U-PMAL | F.01U.324.944
MSD-064G IP SECURITY MICROSD CARD 64GB
64 GB industrial microSD card with health status
monitoring
Order number MSD-064G | F.01U.394.680
MSD-128G IP SECURITY MICROSD CARD 128GB
128 GB industrial microSD card with health status
monitoring
Order number MSD-128G | F.01U.394.681
MSD-256G IP SECURITY MICROSD CARD 256GB
256 GB industrial microSD card with health status
monitoring
Order number MSD-256G | F.01U.394.682
NCA-U-PIG Push-in grommet IP66 patch comp. 25pcs
Push-in grommet IP66 patch comp. 25pcs
Order number NCA-U-PIG | F.01U.411.437
NCA-U-PIGS Push-in grommet IP67 4.5-7.5mm 25pcs
Push-in grommet IP67, 4.5-7.5mm, 25pcs
Order number NCA-U-PIGS | F.01U.411.438
NCA-U-PIGL Push-in grommet IP67 7.5-10mm 25pcs
Push-in grommet IP67, 7.5-10m, 25pcs
Order number NCA-U-PIGL | F.01U.411.568
Represented by:
Data subject to change without notice | 202310170957 | V3 | October 17, 2023 © Bosch Security Systems 2023
CERTIFICATE OF QUALITY
CONTRACT No. 01.AVIOTEC/2025/AICE-BOSCH/VS
Date 29 April 2025
Invoice Number: 3390045842
This is hereby to certify that the following BOSCH branded products manufactured by Bosch Manufacturer Plant have
passed the Quality Control and tested according to the relevant internationally recognized standards and manufacturer’s
Quality Standards of Manufacturer Plant. As such, their Quality is certified for conformity and satisfaction of the
customer.
Commercial Type
No. SAP Description Unit Quantity Origin
No.
1 F.01U.406.348 FCS-8000-VFD-I Bullet 4MP 4.4-10mm IP67 pcs 58 Portugal
Leonard Hew
Head of Sales & Marketing, Asia Pacific
Business Unit Fire Safety, Building Technologies,
Robert Bosch (SEA) Pte Ltd
Rickmond Tong
Controller
Robert Bosch (SEA) Pte Ltd
Building Technologies
By this letter, Building Technologies of Robert Bosch (South East Asia) Pte
Ltd, headquartered in Singapore, hereby confirms that Applied Illumination
and Electronics Co., Ltd. will be the entity responsible for importing the goods
and delivering them to Saigoncomm Corporation.
The shipment includes 58 units of Infrared Bullet Cameras with IP67 rating,
4MP resolution, and 4.4–10mm focal length (Model: FCS-8000-VFD-I),
along with all relevant supporting documents, including:
• Certificate confirming that Applied Illumination and Electronics Co., Ltd. 14th February 2025
Page 2 of 2
is an authorized distributor of Bosch in Vietnam.
• Goods delivery and receipt report.
• Certificate of Origin (CO) and Certificate of Quantity/Quality (CQ).
• Technical documentation of the product.
• VDS 3487 certificate for Camera FCS-8000-VFD-I.
• Valid ISO 17025 international laboratory accreditation certificate.
• Product test report equivalent to or exceeding VDS 3487 standards.
Note: Building Technologies of Robert Bosch (South East Asia) Pte Ltd,
headquartered in Singapore, shall not be held liable for any purchase
transactions conducted outside of the authorized distributor network.
We kindly ask for your understanding and cooperation to ensure that all
transactions proceed smoothly and effectively.
Thank You.
Yours sincerely,
2025
Your expertise and dedication to quality and service along with your
commitment to training entitle you to this prestigious distinction.