Safran 4001 001 10 Datasheet

The Series 4001 Sub-Miniature Precision Circuit Breaker is a lightweight, space-qualified device designed to interrupt high currents, with a capacity of up to 6,000A at 30V DC and 3,500A at 120V AC. It meets military specifications for durability, vibration, and shock, and is suitable for both AC and DC circuits. The breaker is available in various ampere ratings and configurations, with detailed performance data and ordering information provided.

Uploaded by

wyortiz75
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views2 pages

Safran 4001 001 10 Datasheet

The Series 4001 Sub-Miniature Precision Circuit Breaker is a lightweight, space-qualified device designed to interrupt high currents, with a capacity of up to 6,000A at 30V DC and 3,500A at 120V AC. It meets military specifications for durability, vibration, and shock, and is suitable for both AC and DC circuits. The breaker is available in various ampere ratings and configurations, with detailed performance data and ordering information provided.

Uploaded by

wyortiz75
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Series 4001 Sub-Miniature Precision Circuit Breaker

The space-qualified product uti- PERFORMANCE DATA


lizes the same internal design. Interrupting Capacity 1 to 5A: 6,000A at 30V, DC. 7 1/2 to 25A: 2,000A at 30V, DC 1A: 3,500A at 120V, 400 Hz., AC. 2 to 5A: 800A
at 120V, 400 Hz., AC 7 1/2 to 25A: 500A at 120V, 400 Hz., AC
Single-Pole High Endurance * At 120V, 400 Hz., AC, or 28V, DC: inductive load — 2,500 cycles; resistive load — 5,000 cycles; mechanical
Performance cycling, no load — 5,500 cycles
Overload Cycling 100 operations at 200% rated current and rated voltage
Qualified
Dielectric Strength 1,500V, minimum
To MS22073 of MIL-C-5809 Insulation Resistance Not less than 100 megohms at 500V, DC
Lightweight Voltage Drop Varies with rating (see “Ordering Information”)
Vibration* Meets specification MIL-STD-202, Method 204, Condition A, 10G, 10-500 Hz.
Under 33 grams (.073 lbs) MS “V” type (4001-008) meets Condition B, 15G, 10–2,000 Hz. and Condition C, 10G, 10–2,000 Hz.
High Interrupting Capacity MS “D“ type (4001-011) meets Random Vibration levels
Shock * Exceeds 30G’s, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J
Interrupts up to 6,000A circuit at
Acceleration Exceeds 10G’s
30V, DC; and up to 3,500A cir-
Weight 33 grams (0.073 lbs.)
cuit at 120V, 400 Hz. AC.
* Variations of these circuit breakers are capable of exceeding the standard Mil specification for endurance, vibration, and shock.
Not Sensitive To Frequency Or Consult the business unit for more information.
Voltage
Breaker may be used on either
AC or DC circuits.
Performance Rated Circuit
Breaker OVERLOAD CALIBRATION DATA
Meets or exceeds military speci-
fication requirements for durabil- Specification @ 25°C @ +71°C @ -55°C Test Time
Table MIN MAX MIN MAX MIN MAX Parameters
ity, vibration, mechanical shock,
Must Hold 115 — 90 — 135 — % For 1 Hour
and acceleration.Precision inter-
Must Trip — 150 — 130 — 180 % Within 1 Hour
nal design provides a time-tem-
perature characteristic capable 200% Overload 2.000 20.0 — — — — Seconds

of protecting either wire or 500% Overload 0.160 2.0 — — — — Seconds


equipment. With a case 1 1/2 1000% Overload 0.046 0.5 — — — — Seconds
inches long, the breaker weighs Trip curve available
less than 33 grams, and is ideal
for today’s demanding design
requirements.

ORDERING INFORMATION
STANDARD HIGH VIBRATION RANDOM VIBRATION
MS APPROVAL AMPERE VOLTAGE MS P/N EATON MP MS P/N EATON MP P/N MS P/N EATON MP
STATUS RATING DROP P/N P/N
MAX. *
MS Approved 1 1.10 MS22073-1 4001-001-1 MS22073-1V 4001-008-1 MS22073-D1 4001-011-1
MS Approved 1 1/2 0.75 MS22073-1 1/2 4001-001-105 MS22073-1 1/2V 4001-008-105 MS22073-D1 1/2 4001-011-105
MS Approved 2 0.75 MS22073-2 4001-001-2 MS22073-2V 4001-008-2 MS22073-D2 4001-011-2
MS Approved 2 1/2 0.70 MS22073-2 1/2 4001-001-205 MS22073-2 1/2V 4001-008-205 MS22073-D2 1/2 4001-011-205
MS Approved 3 0.55 MS22073-3 4001-001-3 MS22073-3V 4001-008-3 MS22073-D3 4001-011-3
MS Approved 4 0.45 MS22073-4 4001-001-4 MS22073-4V 4001-008-4 MS22073-D4 4001-011-4
MS Approved 5 0.35 MS22073-5 4001-001-5 MS22073-5V 4001-008-5 MS22073-D5 4001-011-5
MS Approved 7 1/2 0.30 MS22073-7 1/2 4001-001-705 MS22073-7 1/2V 4001-008-705 MS22073-D7 1/2 4001-011-705
MS Approved 10 0.28 MS22073-10 4001-001-10 MS22073-10V 4001-008-10 MS22073-D10 4001-011-10
MS Approved 15 0.25 MS22073-15 4001-001-15 MS22073-15V 4001-008-15 MS22073-D15 4001-011-15
MS Approved 20 0.25 MS22073-20 4001-001-20 MS22073-20V 4001-008-20 MS22073-D20 4001-011-20
Non MS 25 0.20 MS22073-25 4001-001-25 MS22073-D25V 4001-008-25 MS22073-D25 4001-011-25
Approved
* AT RATED NOMINAL CURRENT
For other amperage ratings and configurations, consult the Business Unit.

20 EATON CORPORATION Aerospace TF300-1 December, 2003


Series 4001

DIMENSIONS

.780 Ampere Rating In


MAX. White Figures .375 ± .005

.593

3
MAX.

.125 ± .005 DIA.

.484 ± .005 DIA.

.410 DIA.
Mounting Lockwasher
MS35333-136B .469-32UNS-2A
Mounting Nut Threaded Bushings
MS25082-C21

.467 MIN. .750 MAX.


Closed Tripped
.250

1.852 1.535 MAX.


1.707
MAX.

45
.352 2 Screws MS51957-41 &
Lockwashers MS35338-137
.703

TRIP CURVE
Percentage Of Circuit Breaker’s Rated Current

10000 TYPICAL
TRIP
CURVE
AT 25°C

1000

150%
100 115%

0
0.01 0.1 1.0 10 100 1000 10000
Time To Open (Trip) In Seconds

EATON CORPORATION Aerospace TF300-1 December, 2003 21