© Siemens AG 2018
Weighing Electronics
SIWAREX weighing electronics for SIMATIC
Ex-Interface
SIWAREX IS
■ Overview ■ Technical specifications
Ex interface, Standard Low-current version
type SIWAREX IS
Non-intrinsically-safe circuits
Load cell powering
Rated voltage Un1 10 V DC
2 Permissible error voltage
Internal resistance of load
250 V AC
8.7 /V 18 /V
cells depending on input
voltage
Total < 4 010
Sensor line
Rated voltage Un2 10 V DC
Permissible error voltage 250 V AC
Measuring signal line
Rated voltage Un3 10 ... 40 mV DC
Permissible error voltage 250 V AC
SIWAREX IS New Generation
Intrinsically safe circuits
The Ex-Interface SIWAREX IS can be used for SIWAREX weigh-
ing modules. It comprises six safety barriers and has been Load cell powering
granted the approvals stated in the technical data. The Ex inter- No-load voltage U01 13.1 V DC
face must be installed outside the potentially explosive area. It is Voltage against equipotential 6.6 V DC
installed inside the control cabinet, preferably under the elec- bonding cond.
tronic weighing system, and fixed using a 35 mm mounting rail.
Short-circuit current IK1 120 mA 58 mA
The SIWAREX IS only interferes with the load cell signal to a very Sensor line
small extent and is therefore approved for scales requiring veri-
fication. No-load voltage U02 14.4 V DC
Voltage against equipotential 7.2 V DC
The connection is made at the front using two clamp-type plugs. bonding cond.
A separate screw terminal is available for connection of the equi-
potential bonding conductor (EBC). Short-circuit current IK2 25 mA
Measuring signal line
■ Function No-load voltage U03 12.8 V DC
Voltage against equipotential 6.4 V DC
Principle of operation bonding cond.
The safety barriers limit current and voltage in the power, sensor Short-circuit current IK3 54 mA
and measuring signal lines of load cells installed in the poten-
Total connection load
tially explosive area.
(when circuits are connected
together)
Input Output
No-load voltage U0 14.4 V DC
Shield Shield
Exc + Exc + Short-circuit current IK 199 mA 137 mA
Supply Current
Voltage
lines Exc - limitation
limitation Exc - Power PO 1.835 W 1.025 W
(active)
For gas group II C
Sense + Current Sense + Max. permissible external 500 nF 450 nF
Feedback Voltage Instrinsically capacitance Ca3
Sense - limitation Sense -
lines limitation safe area
(passive)
Max. permissible external 0.15 mH 0.5 mH
inductance La
Signal + Current Signal +
Signal Voltage For gas group II B
Signal - limitation Signal -
lines limitation
(passive) Max. permissible external 2 000 nF
capacitance Ca3
Equipment Potential equalisation
grounding (PE) line (PAL)
Max. permissible external 1 mH 2 mH
inductance La
Function chart
2/60 Siemens WT 10 · 2018
© Siemens AG 2018
Weighing Electronics
SIWAREX weighing electronics for SIMATIC
Ex-Interface
SIWAREX IS
Ex interface,
type SIWAREX IS
Standard Low-current version
■ Dimensional drawings
General data
Weight, approx. 500 g
Permissible ambient
temperature
• During operation -10 ... +60 °C (14 ... 140 °F)
(for vertical mounting)
105 (4.13)
• During operation for legal-
for-trade medium accuracy
-10 ... +40 °C (14 ... 104 °F)
(for vertical mounting) 2
weighing machines
• During transportation and -40 ... +85 °C (-40 ... +185 °F)
storage
Permissible relative humidity 95%
Degree of protection IP20
Approvals
75 (2.95) 123 (4.84)
EC type test certificates No. TÜV 01 ATEX 1722 X
Type of explosion protection Intrinsic safety "i" PAL connection
II (2) G [Ex ibGb] IIC
or
II (2) D [EX ib Db] IIIC
IEC certification IECEx TUN 06.0002 X
[Ex ib Gb] IIC
or
[Ex ib Db] IIIC
Calibration approval (German EN 45501, OIML R76-1, 90/384/EEC
Testing Laboratory test certifi-
cate) according to
■ Selection and ordering data Article No.
Ex interface SIWAREX IS
For intrinsically-safe connection of SIWAREX IS Ex interface, dimensions in mm (inch)
load cells. Suitable for SIWAREX
electronic weighing system. The
compatibility of the load cells must
be checked.
• With short-circuit current 7MH4710-5BA
< 199 mA DC
• With short-circuit current 7MH4710-5CA
< 137 mA DC
Cable (optional)
Cable Li2Y 1 x 2 x 0.75 ST +
2 x (2 x 0.34 ST) – CY
For connecting SIWAREX electronic
weighing systems to junction box
(JB), extension box (EB) and Ex
interface or between two JBs.
For permanent installation. Occa-
sional bending is possible.
External diameter:
approx. 10.8 mm (0.43 in)
Permissible ambient temperature
-40 ... +80 °C (-40 ... +176 °F).
Sold by the meter.
• Sheath color orange. 7MH4702-8AG
• For potentially explosive atmo- 7MH4702-8AF
spheres. Sheath color: blue.
Siemens WT 10 · 2018 2/61