J A N U A R Y 2 0 1 0 C A T A L O G
INDUSTRIAL/ 1
CONFINED SPACE
Electric
HAZARDOUS 9
LOCATIONS
Electric • Air
SMOKE 19
REMOVAL
Gas • Electric • Water
ACCESSORIES 37
Ducting • Misting Systems • Plugs • Adapters
Meeting this standard ensures that Euramco Safety fulfills the customer’s
quality requirements and applicable regulatory requirements, while aiming
to enhance customer satisfaction and achieve continual improvement of its
performance in pursuit of these objectives.
2 www.EuramcoSafety.com
Quick-Couple™ Reversible Canister
Detachable in seconds, the Quick-Couple™
Canister with attached duct conveniently reverses
from discharge to suction, making use and storage
easier while protecting duct from rips and tears.
Available with 15’/4.6m or 25’/7.6m of duct.
15’/4.6m canister: 14h x 12w x 31.5d in.
35.6h x 30.5w x 80d cm
25’/7.6m canister: 14h x 12w x 41.5d in.
35.6h x 30.5w x 105d cm
Order # System Includes
ED6015 20cm 115V, 50Hz Blower/Exhauster, Quick-Couple Canister w/ 4.6m duct
ED6025 20cm 115V, 50Hz Blower/Exhauster, Quick-Couple Canister w/ 7.6m duct
ED7015 8” 110V Blower/Exhauster, Quick-Couple Canister w/ 15’ duct
ED7025 8” 110V Blower/Exhauster, Quick-Couple Canister w/ 25’ duct
ED8015 20cm 240V, 50Hz Blower/Exhauster, Quick-Couple Canister w/ 4.6m duct
ED8025 20cm 240V, 50Hz Blower/Exhauster, Quick-Couple Canister w/ 7.6m duct
ED9015 8” 12V Blower/Exhauster, Battery Clips, Quick-Couple Canister w/ 15’ duct
ED9025 8” 12V Blower/Exhauster, Battery Clips, Quick-Couple Canister w/ 25’ duct
UB20 Turbo-Couple™
Long Distance Ventilation Solution
Quick-connecting two or more RAMFAN UB20 axial
blowers in series increases airflow up to 50%
when blowing through long and windy duct runs.
Designed for duct runs up to 25’/7.6m, the UB20
airflow significantly drops when blowing through
more than 75’/22.9m of duct or when confronted
with multiple turns in the duct.
Long, windy duct runs need more power and
pressure to deliver sufficient airflow, a costly Patent no. D602,347S
■ UB-line compatible
■ UB20xx compatible
■ High impact polyethylene
www.EuramcoSafety.com 3
INDUSTRIAL/
CONFINED SPACE
Battery Pak & Charger –
12V DC High-Low Control UB20
RAMFAN’s long-life Battery Pak now with infinitely
high-low control. Pulse width modulation extends
battery life up to 10 hours in low setting yet gives a
full 2.5 hours on high. Can be used with vehicle
battery with optional connector. Built-in charger
allows you to fully recharge the battery in 12 hours.
Purge the area on high for 10 minutes, reduce to
low speed (low-noise as well) and maintain fresh
air for the whole work shift. Ideal for construction job
sites to eliminate noisy gasoline-engine blowers.
■ High-low control enables fast-purge ventilation
and lower speed for maintaining safe work space
Order # System Includes ■ High impact case includes battery and built-in
BPV-12 12V DC Battery Pak w/ built in Charger charger for overnight charging
ED9015-BAT 8”/20cm Blower/Exhauster, 12V DC Battery Pak ■ Up to 10 hours of continuous operation
with Built-in Charger, Quick-Couple Canister ■ Lightweight and portable
with 15’/4.6m duct
ED9025-BAT 8”/20cm Blower/Exhauster, 12V DC Battery Pak
with Built-in Charger, Quick-Couple Canister
with 25’/7.6m duct
UB20 Mister
■ Misting collar mounts easily to UB20 Blower
■ Garden hose connection uses 2.1gph of water
for cooling mist injected into airflow
■ Cools airflow up to 25 degrees
4 www.EuramcoSafety.com
UB20 M.E.D.™
Manhole Entry Device
The M.E.D. allows workers to enter and exit small
man-size openings while maintaining continuous
ventilation. Without such a device, duct fills the
manhole opening, preventing rapid entry and exit.
Tightly integrated into the UB-line of confined
space ventilation equipment, RAMFAN’s M.E.D. is
quick to assemble and the new swiveling elbow
makes duct alignment easy.
Changing its cross-section from circular to elliptical
and back to circular minimizes loss and optimizes
airflow into a confined space, while providing
adequate room for the worker to enter and exit
unimpeded. The rugged polyethylene construction System Includes: 8”/20cm Blower/Exhauster, Quick-
endures heavy, negligent use and will last for years. Couple Canister with 15’/4.6m or 25’/7.6m of duct,
Comprised of three components, the M.E.D., Manhole Entry Device, 90° Elbow, Universal Mount
swiveling elbow, and universal mount, the RAMFAN
M.E.D. system increases safety by maintaining Order #
continuous airflow. ED7015-MED 115V/60Hz Blower with 15’/4.6m and 5’/1.5m Duct
■ Ventilate without blocking entry ED8015-MED 220V/60Hz Blower with 15’/4.6m and 5’/1.5m Duct
www.EuramcoSafety.com 5
INDUSTRIAL/
CONFINED SPACE
UB20 In-Line Heating System
RAMFAN’s UB20 In-Line Heating System with its
propane-fired, heat-exchanger provides safe, warm
breathing air during cold conditions.
■ For tent/shelter or confined space heating
■ Airflow can cycle with heat or run continuous
for confined space ventilation
■ Remote thermostat included
■ Up to 10 hours of continuous operation with
standard propane cylinder tank
■ Heater attaches quickly and easily to UB20 blower
■ Output: 70,000 BTU/13.5kW
■ Includes propane regulator and connection assembly
■ Easy access top mounted heater control panel
■ Compatible with UB20 M.E.D. system
■ IP20 rated enclosure
ORDER PACKAGES
Confined Space Heating
Order # HA01-100HT HA02-100HT HA03-100HT
System Options UB20 8” Blower, Heater with UB20 20cm Blower, Heater with UB20 20cm Blower, Heater with
Regulator, Quick-Couple Regulator, Quick-Couple Regulator, Quick-Couple
Canister w/ 15’ Duct Canister w/ 4.6m Duct Canister w/ 4.6m Duct
Order # HA01-125HT HA02-125HT HA03-125HT
System Options UB20 8” Blower, Heater with UB20 20cm Blower, Heater with UB20 20cm Blower, Heater with
Regulator, Quick-Couple Regulator, Quick-Couple Regulator, Quick-Couple
Canister w/ 25’ Duct Canister w/ 7.6m Duct Canister w /7.6m Duct
Tent/Shelter Heating
Order # ED7125-HT ED6125-HT ED8125-HT
System Options UB20 8” Blower, Heater w/ UB20 20cm Blower, Heater w/ UB20 20cm Blower, Heater w/
Regulator, 15’ Duct, Regulator, 4.6m Duct, Regulator, 4.6m Duct,
Duct Storage Bag Duct Storage Bag Duct Storage Bag
6 www.EuramcoSafety.com
A powerful, new 12 inch RAMFAN is born. Building on “UB” technology, the patent-pending UB30 is simply
the toughest, most durable, easy to maintain and versatile blower in its class. Unmatched performance,
dual voltage-dual frequency versatility, tough polymer shell and turbo-impeller design makes for an
unbeatable package. Priced to compete and ready to ship, the UB30 is supported by Euramco Safety’s
key product stocking program in our strategic warehouse locations. See back cover for stocking locations.
MODEL UB30
Order # EJ4002 EJ8002
STOCK LOCATIONS
FREE AIRFLOW 2,420cfm 2,873m3/h
15ft/4.6m 1-90° turn 2,050cfm 2,550m3/h
15ft/4.6m 2-90° turns 1,875cfm 2,340m3/h 12”/30cm to 8”/20cm
IMPELLER 11-blade 11-blade Duct Adapter/Reducer
www.EuramcoSafety.com 7
INDUSTRIAL/
CONFINED SPACE
8 www.EuramcoSafety.com
HAZARDOUS
LOCATIONS
HAZARDOUS
LOCATIONS
The Explosion Proof Rating – Recognized Worldwide: We have designed and manufactured a line
of fans specifically for use in Explosive Atmospheres to meet the standards specified by the ATEX Directive 94/9/EC, which
went into effect on March 1, 1996 and applies to all manufacturers worldwide.
This directive applies to all electrical equipment used in potentially explosive atmospheres; defined as gas, vapor or mist
and are capable of causing an explosion through their own potential sources of ignition.
All RAMFAN Explosion Proof Blowers and Exhausters have been certified by UL to bear the ATEX Mark and have been
tested to the standards set forth in the ATEX Directive. Our certification covers the whole unit: the motor, the connecting
cable, the fan blade terminal box, the power cable and the plugs.
The following information explains the ATEX Classification and Designation Identification Numbering System. The Highlighted
areas specifically apply to the Classification Designation numbers you will see on our explosion proof units.
TEMPERATURE CLASSES
Can Be
Ignition Protection Categories I.D. Used In Safety Principle
Box
Class T1 T2 T3 T4 T5 T6
Increased safety Ex e Zone 1 No arcs, sparks or MAXIMUM SURFACE TEMPERATURE
Non-sparking equipment Ex nA Zone 2 hot surfaces 450°C 300°C 200°C 135°C 100°C 85°C
Pressurised encapsulation Ex d Zone 1 Controls an internal IIA Acetone i-Amylacetate Gasolines Acetal- – –
Sand encapsulation Ex q Zone 1 explosion and Ammoniac n-Butane Diesel Fuels dehyde
extinguishes the flame Benzene n-Butyl Alcohol Heating Oils
Motor
Gas Group IIB, Class T6 includes all specifications for Gas Group
EC-Type Examination Certificate Number: DEMKO 09 ATEX 092696 IIA, Class T1-T6 and Gas Group IIB, T1-T6
CE Hazardous Location Marking: CE0539
Ingress Protection: IP55 Highlighted areas in charts apply to
Euramco Safety’s ATEX Certification String
10 www.EuramcoSafety.com
8”/ 20cm | UB20xx
Intrinsically Safe Blower/Exhauster
■ Intrinsically safe blower -- ATEX certified for safe use
in a variety of adverse atmospheres
■ Compact and lightweight
■ Tough dual wall casing – weather proof,
chemical resistant and dent proof
■ Ultra-quiet
■ Power cable is 30ft/9m long
■ IMPA Codes:
EF7002 - 591416
EF8002 - 591417
Optional Accessories: Quick-Couple
Canister, Duct Adapters, Cooling Collar,
Anti-Static Duct, Duct Carrying Bags,
UB20xx with Duct Adapter
Electric Plugs
UB20xx 115V UB20xx 115V (60Hz) UB20xx 220V UB20xx 220V (50Hz)
MODEL (60Hz) with Q-C Canister* (50/60Hz) with Q-C Canister*
Order # EF7002 EF7015 (15’/4.6m duct) EF8002 EF8015 (15’/4.6m duct)
EF7005 (w/ duct EF7025 (25’/7.6m duct) EF8005 (w/ duct EF8025 (25’/7.6m duct)
adapter) adapter)
STOCK LOCATIONS
FREEFLOW 980cfm/1,666.3m3/hr 980cfm/1,666.3m3/hr 819cfm/1,392.3m3/hr 819cfm/1,392.3m3/hr
15’/4.6m 1-90° turn 789cfm/1,341.3m3/hr 789cfm/1,341.3m3/hr 659cfm/1,120.3m3/hr 659cfm/1,120.3m3/hr
15’/4.6m 2-90° turns 666cfm/1,132.2m /hr3
666cfm/1,132.2m /hr 3
557cfm/947m /hr3
557cfm/947m3/hr
25’/7.6m 1-90º turn 722cfm/1,227.4m /hr3
722cfm/1,227.4m /hr 3
603cfm/1,025.1m /hr3
603cfm/1,025.1m3/hr
25’/7.6m 2-90º turns 614cfm/1043.8m3/hr 614cfm/1,043.8m3/hr 510cfm/867m3/hr 510cfm/867m3/hr
WEIGHT 22lbs/10kg 22lbs/10kg 22lbs/10kg 22lbs/10kg
DIMENSIONS 14/12/14 in 14/12/14 in 14/12/14 in 14/12/14 in
(h/w/d) 356/305/356 mm 356/305/356 mm 356/305/356 mm 356/305/356 mm
NOISE 74dB 74dB 74dB 74dB
MOTOR 0.33Hp/0.25kW 0.33Hp/0.25kW 0.25Hp/0.19kW 0.25Hp/0.19kW
ELECTRIC 115VAC, 1ø 115VAC, 1ø 220VAC, 1ø 220VAC, 1ø
AMPS – RUN 2A 2A 1.2A 1.2A
UNIT II 2 G Ex de IIB T6 II 2 G Ex de IIB T6 II 2 G Ex de IIB T6 II 2 G Ex de IIB T6
CERTIFICATION
BR-Ex de IIB T6 BR-Ex de IIB T6 – –
www.EuramcoSafety.com 11
HAZARDOUS
LOCATIONS
UB20xx M.E.D.™
Manhole Entry Device
The Intrinsically Safe UB20xx System utilizes high
strength polymers with an anti-static housing
designed to discharge static build-up safely. The
M.E.D. allows workers to enter and exit small
man-size openings while maintaining continuous
ventilation. Without such a device, duct fills the
manhole opening, preventing rapid entry and exit.
Tightly integrated into the UB-line of confined
space ventilation equipment, RAMFAN’s M.E.D. is
quick to assemble and the new swiveling elbow
makes duct alignment easy.
Changing its cross-section from circular to elliptical
and back to circular minimizes loss and optimizes
airflow into a confined space, while providing Order #
adequate room for the worker to enter and exit EF7015-MEDXX 115V/60Hz Blower with 15’/4.6m and 5’/1.5m Duct
unimpeded. The rugged polyethylene construction
EF8015-MEDXX 220V/60Hz Blower with 15’/4.6m and 5’/1.5m Duct
endures heavy, negligent use and will last for years.
Comprised of three components, the M.E.D.,
swiveling elbow, and universal mount, the RAMFAN
M.E.D. system increases safety by maintaining
continuous airflow.
■ Ventilate without blocking entry
■ Maintain airflow while working
■ UB-line compatible
■ Anti-static housing
12 www.EuramcoSafety.com
12”/ 30cm | EFi75xx/EFi85xx
Intrinsically Safe Blower/Exhauster
■ Intrinsically safe – ATEX certified for use in
adverse atmostphere
■ Cast aluminum turbo blade is precision balanced
■ Tough, chemical resistant ABS housing, carbon-filled
to conduct static charges to ground
■ IP65 rain tested switch enclosure “watertight”
■ Integral 12”/30cm duct adapters
■ Blow or exhaust hazardous/explosive gases safely
■ Uses 12”/30cm or 8”/20cm duct, (8”/20cm
requires optional adapter) conductive or non,
suction or discharge
■ IMPA Codes:
EB7201xx (110V) - 591506
EB7201xx-230 (230V) - 591506
Optional Accessories: Anti-Static Duct, Duct Carrying
Bags, Cooling Collar
BR-Ex de IIB T6 –
www.EuramcoSafety.com 13
HAZARDOUS
LOCATIONS
– – BR-Ex de IIB T6
14 www.EuramcoSafety.com
16”/ 40cm | AFi50xx
Intrinsically Safe Air Driven
Blower/Exhauster
■ Intrinsically safe for use in adverse atmospheres
■ Pneumatic powered blower
■ Precision balanced, cast aluminum turbo impeller
■ High Strength, anti-static glass reinforced ABS
housing is lightweight, corrosion proof and
chemical resistant
■ Integral 16”/40cm duct adapters
■ Exhausts OUTSIDE of duct, compressed air
not in airstream
■ Complete with filter, motor lubricator, exhaust
muffler, air control valve and static grounding cord
■ IMPA Codes:
AA7000 - 591512
Optional Accessories: Standard Duct, Anti-Static Duct,
Duct Carrying Bags, Cooling Collar, 16”/40cm Multi-
Purpose Accessory Pack, Door Bar and Hanger Kit
MODEL AFi50xx
Order # AA7000
STOCK LOCATIONS
FREE AIRFLOW 3,200cfm/5,440m3/hr
AIR CONSUMPTION 40cfm/68m3/hr
INDUCTION RATIO 80:1
WEIGHT 43lbs/20kg
DIMENSIONS 19/21/12 in
(h/w/d) 480/530/305 mm
NOISE 89dB
MOTOR GAST 4AM-NRV-50C
* Measurements @ 80psig inlet air
www.EuramcoSafety.com 15
HAZARDOUS
LOCATIONS
MODEL AFi75xx
Order # AB7000
STOCK LOCATIONS
FREE AIRFLOW 2,042cfm/3,471.4m3/hr
AIR CONSUMPTION 40cfm/68m3/hr
INDUCTION RATIO 51:1
WEIGHT 38lbs/15kg
DIMENSIONS 16/17/16 in
(h/w/d) 410/430/410 mm
NOISE 89dB
MOTOR GAST 4AM-NRV-50C
* Measurements @ 80psig inlet air
16 www.EuramcoSafety.com
Venturi Cones | RV760S/RV760/RV1500
■ Intrinsically safe for use in adverse or explosive
atmospheres when used with optional static cord
■ Pneumatic (compressed air) or saturated steam powered
■ Crush and dent resistant, anti-static, polyethylene cone
■ Cylindrical mixing chamber delivers higher induction ratios
■ Fits standard API 3”/7cm and 6”/15cm openings
■ No moving parts
■ Requires minimum maintenance
■ IMPA Codes:
RV760S - 591430
RV760 - 591432
RV1500 - 591433
Order # Accessory
AZ-RAC-10 Static Cord
www.EuramcoSafety.com 17
HAZARDOUS
LOCATIONS
18 www.EuramcoSafety.com
SMOKE
REMOVAL
SMOKE
REMOVAL
Why We Use AMCA: AMCA, The Air Movement and Control Association International,
has been in existence for nearly 80 years and is the world’s only recognized authority for
the development of standards and measurement of air movement.
Our commitment to AMCA Certification is your verifiable assurance that every RAMFAN PPV
Turbo Blower will perform exactly as specified.
MODEL SIZE HP HEIGHT x WIDTH x DEPTH MOTOR MFG./MODEL NO. WEIGHT RPM SET BACK ANGLE AIRFLOW at FREE AIR
inches cm lbs kg ft m tilt cfm m3/hr
GF165 US 16” 6.0 21.5 x 20 x 22 55 x 51 x 51 HONDA GX200 86 39 3767 4’ 1.2 16° 13,434 22,838
6’ 1.8 16° 14,421 24,516
8’ 2.4 16° 12,479 21,214
GF165 EUR 16” 5.5 21.5 x 20 x 22 55 x 51 x 51 HONDA GX160K1 86 39 3603 4’ 1.2 16° 12,906 21,940
GF165SE 16” 5.0 21.5 x 20 x 22 55 x 51 x 51 HONDA GC160 76 35 3498 4’ 1.2 16° 11,815 20,085
GF164SE 16” 5.0 21 x 20 x 17 53 x 51 x 43 HONDA GC160 59 27 3390 8’ 2.4 16° 10,058 17,099
GF210 US 21” 6.0 25.25 x 24.25 64 x 62 x 49 HONDA GX200 88 40 3786 4’ 1.2 20° 14,426 24,524
x 19.5
6’ 1.8 20° 15,616 26,547
8’ 2.4 20° 17,059 29,000
10’ 3.0 20° 16,793 28,548
GF210 EUR 21” 5.5 25.25 x 24.25 64 x 62 x 49 HONDA GX160K1 88 40 3726 8’ 2.4 20° 17,670 30,039
x 19.5
GF240 24” 5.5 29 x 28 x 21 74 x 71 x 53 HONDA GX160K1 115 52 1847 5’ 1.5 17° 17,268 29,355
EF400 16” 1.5 23 x 17 x 16 58 x 43 x 41 Franklin 113300418 74 34 3512 6’ 1.8 20° 9,408 15,993
TEAO
EV400 15amp 16” 1.5 23 x 17 x 16 58 x 43 x 41 YM-EM F1.5-90 68 31 3267 4’ 1.2 20° 8,466 14,392
6’ 1.8 20° 9,184 15,613
8’ 2.4 20° 8,646 14,698
EV400 20amp 16” 1.5 23 x 17 x 16 58 x 43 x 41 YM-EM F1.5-90 68 31 3978 4’ 1.2 20° 10,618 18,051
6’ 1.8 20° 11,391 19,365
8’ 2.4 20° 11,049 18,783
EV420 16” 1.5 23 x 17 x 16 58 x 43 x 41 YM-EM F1.5-180 68 31 3640 6’ 1.8 20° 10,084 17,143
EV600 21” 1.5 26 x 24 x 17 66 x 61 x 43 YM-EM F1.5-90 80 36 3588 8’ 2.4 13° 11,061 18,804
EV620 21” 1.5 26 x 24 x 17 66 x 61 x 43 YM-EM F1.5-180 80 36 3360 8’ 2.4 13° 10,818 18,391
WF20 150psi 8” 4.6 16 x 14 x 39 41 x 36 x 99 RAMFAN WA1001 42 19 5689 15’ 4.6 12° 13,125 23,313
Water Motor
WF20 250psi 8” 8.0 16 x 14 x 39 41 x 36 x 99 RAMFAN WA1001 42 19 7260 15’ 4.6 12° 16,511 28,069
Water Motor
WF390L 150psi 16” 4.0 23 x 17 x 16 58 x 43 x 41 RAMFAN WA5101 60 27 3516 6’ 1.8 20° 10,886 18,506
Water Motor
20 www.EuramcoSafety.com
Airflow Ratings
Comparing the CFM performance ratings of PPV blowers can be difficult.
For this reason, Euramco Safety adopted the measuring techniques of Air
Movement & Control Association Standard 240.
RAMFAN turbo blowers were introduced in 1990 and are used by hundreds of
departments and brigades throughout the world. RAMFAN was instrumental in the
standardization of positive pressure airflow testing and fully supports the
implementation of AMCA 211 test specifications.
Ratings are developed in ideal test conditions and are not a guarantee of actual performance.
Entrained air is a large component of PPV airflow and can vary with the size of the entrance and
exit openings; actual airflow can be significantly different.
To the best of our knowledge no testing standard exists, other than Standard 240 of the Air Movement and
Control Association (AMCA), that measures the airflow in a manner consistent with the deployment of blowers
under fire ground situations. Other non-accredited organizations have experimented, but none with published
standards or an active certification program.
www.EuramcoSafety.com 21
SMOKE
REMOVAL
A more focused airflow shape penetrates deeply into layers of super-heated gas, disturbing stratification, dropping temperature
and improving visibility much quicker than a conventional blower with the same or even greater airflow. Low velocity flow does
not have the kinetic energy necessary to penetrate and mix.
22 www.EuramcoSafety.com
Put a RAMFAN TurboForce™ Blower Anywhere in ‘The ZONE’
It Will Generate Peak Ventilation Performance and Faster Clearance and Cooling
to Safely Clear the Way for Advancing Firefighters
NEW!
Set-Up ‘Zone Guides’ for
Quick and Easy Deployment
GF165 ZONE GUIDE EV400 ZONE GUIDE
www.EuramcoSafety.com 23
SMOKE PPV: GAS
REMOVAL
MODEL GF164SE
Order # GB5001HSE
STOCK LOCATIONS
PPV AIRFLOW 11,815cfm/20,085m3/hr
RUN TIME 58min
WEIGHT 59lbs/27kg
DIMENSIONS 21/20/17 in
(h/w/d) 533/508/432 mm
NOISE 96.1dB
MOTOR Honda 5Hp/3.7kW GC Series
24 www.EuramcoSafety.com
PPV: GAS
www.EuramcoSafety.com 25
SMOKE PPV: GAS
REMOVAL
26 www.EuramcoSafety.com
PPV: GAS
MODEL GF240
Order # GD5001
STOCK LOCATIONS
DESCRIPTION Gas Powered PPV Turbo Blower
PPV AIRFLOW – Single Door 17,268cfm/29,355m3/hr
PPV AIRFLOW – Double Door 27,500cfm/46,750m3/hr
RUN TIME 58min
WEIGHT 115lbs/52kg
DIMENSIONS 29/28/20.9 in
(h/w/d) 737/711/531 mm
NOISE 98.5dB
MOTOR Honda 5.5Hp/4.1kW GX160K1
CERTIFICATIONS AMCA (see test report on pg. 20)
www.EuramcoSafety.com 27
SMOKE PPV: ELECTRIC
REMOVAL
28 www.EuramcoSafety.com
PPV: ELECTRIC
www.EuramcoSafety.com 29
SMOKE PPV: ELECTRIC
REMOVAL
30 www.EuramcoSafety.com
PPV: WATER
MODEL WF390L
Order # WB5001LB (BSP) / WB5001LNH (NH)
STOCK LOCATIONS
DESCRIPTION Intrinsically safe, water driven PPV blower
PPV AIRFLOW @150psi 10,886cfm/18,506m3/hr
WEIGHT 60lbs/27kg
DIMENSIONS 23/17/16 in
(h/w/d) 580/430/410 mm
MOTOR 4Hp/3kW
PRESSURE/FLOW Min: 125psi/49gpm
Max: 250psi/70gpm
CONNECTIONS 1.5”/3.8cm NH, BSP
CERTIFICATIONS AMCA (see test report on pg. 20)
www.EuramcoSafety.com 31
SMOKE
REMOVAL
WF20 Performance
180 psi
16
60’
14 150 psi
Static Pressure – Inches H20
8” duct
on discharge
12
WF20 - Ducted
10
8
Water/air couplings to customer specifications
6
4 40 psi 200’
12” duct
on discharge
2
0
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
CONNECTIONS 1.5”/3.8cm NST (NH), NPSH, Duct Adapter, 12”/30cm for use with WA0511
or BSP male connections belted duct – 2 required/blower
32 www.EuramcoSafety.com
PPV: WATER
TEXT
WF20 - Multiplier/
Mister - PPV
www.EuramcoSafety.com 33
SMOKE SMOKE EJECTOR
REMOVAL
34 www.EuramcoSafety.com
SMOKE EJECTOR
www.EuramcoSafety.com 35
SMOKE SMOKE EJECTOR
REMOVAL
36 www.EuramcoSafety.com
ACCESSORIES
ACCESSORIES
Standard Duct – 15’/4.6m & 25’/7.6m
■ ECKO-flex non-collapsible, reinforced duct
■ 8”/20cm, 12”/30cm or 16”/40cm sizes
■ Flame retardant
■ IMPA codes available for ducting, please call to inquire
Cooling Collars/Misters
■ Quickly cool and rehabilitate with a cooling collar
■ Fits around duct adapter of blower injecting mist into airflow
■ Designed for use with a garden hose
■ Available for 8”/20cm, 12”/30cm & 16”/40cm blowers
■ Water output per hour is based on water pressure
38 www.EuramcoSafety.com
BIGbore™ Exhaust Diverter
■ Diverts engine exhaust away from the work environment
■ 2”/5cm diameter flexible, galvanized hose reduces engine
backpressure
■ Quick connect fittings meet DIN standards
■ Additional hose available to extend exhaust diversion
Hanger Kit
■ Suspend smoke ejector box fans in doorway or window for more
efficient ventilation
■ Compatible with all EFi and EFC-series fans
Door Bar
■ For use with Hanger Kit
Manhole Guard
■ Additional safety precaution for the workplace
Manhole Mount
■ Allow for vertical ventilation
■ Aluminum Frame
■ Compatible with all EFi, EFC and EVC-series fans
www.EuramcoSafety.com 39
ACCESSORIES
Electric Plugs
Order # System Includes
EZGFI GFI Plug (replaces standard plug on UB20)
EZ-5-15P 110–130V 15amp NEMA Plug 5-15P
EZ-L5-15P 110–130V 15amp NEMA Plug L5-15P (Twist-Lok)
EZ-L5-20P 110–130V 20amp NEMA Plug L5-20P (Twist-Lok)
EZ-L5-30P 110–130V 30amp NEMA Plug L5-30P (Twist-Lok)
EZ-L6-20P 200–250V 20amp NEMA Plug L6-20P (Twist-Lok)
EZ-L6-30P 200–250V 30amp NEMA Plug L6-30P (Twist-Lok)
EZ-UGP15231 110–130V 15amp Killark Plug Haz Loc (use w/ UB20xx)
EZ-999-21000 110–130V 16amp Non-ATEX Shuko Plug (Euro Standard)
EZ-999-21001 200–250V 16amp Non-ATEX Shuko Plug (Euro Standard)
EZ-ATX96430 110–130V 16amp ATEX Haz. Loc. Shuko Plug (Euro Standard)*
EZ-ATX96433 200–250V 16amp ATEX Haz. Loc. Shuko Plug (Euro Standard)*
EZ-88010920 200–250V 16amp Shuko Plug (Euro Standard)
Duct Couplers
Order # System Includes
DC8 8”/20cm Duct Coupler Stainless HD
DC12 12”/30cm Duct Coupler Stainless HD
DC16 16”/40cm Duct Coupler Stainless HD
Duct Adapters/Reducers
Order # System Includes
ED0304 8”/20cm Inlet Duct Adapter for UB20
EF0304X 8”/20cm Anti-Static Inlet Duct Adapter for UB20xx
EC0301 12”/30cm to 8”/20cm Duct Adapter/Reducer
EA7006 16”/40cm Duct Adapter
40 www.EuramcoSafety.com
Quick Reference Order Guide
www.EuramcoSafety.com 41
ACCESSORIES
Quick Reference Order Guide, Continued
42 www.EuramcoSafety.com
Euramco Warehouses:
Distributed by:
www.EuramcoSafety.com
RAMAMCA January 2010