Current Transducer LT 4000-T/SP11 IPN = 4000 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
IPN Primary nominal r.m.s. current 4000 A Features
IP Primary current, measuring range 0 .. ± 6000 A • Closed loop (compensated) current
RM Measuring resistance RM min RM max transducer using the Hall effect
with ± 24 V @ ± 4000 A m a x 0 10 Ω • Insulated plastic case recognized
@ ± 6000 A m a x 0 2 Ω according to UL 94-V0.
ISN Secondary nominal r.m.s. current 800 mA
KN Conversion ratio 1 : 5000 Special features
VC Supply voltage (± 5 %) ± 24 V • Vd = 9 kV 1)
IC Current consumption 30 + IS mA • TA = - 40°C .. + 70°C
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 9 1) kV • Shield
1 2) kV • Connection to secondary circuit on
Ve R.m.s. voltage for partial discharge extinction AMP CPC 13/9
@ 50 pC 2.5 kV • Burn-in
^
• Railway equipment.
Accuracy - Dynamic performance data
Advantages
X Accuracy @ IPN , TA = 25°C ± 0.5 % • Excellent accuracy
ε L
Linearity < 0.1 % • Very good linearity
Typ Max • Low temperature drift
IO Offset current @ IP = 0, TA = 25°C ± 0.8 mA • Optimized response time
IOT Thermal drift of IO - 40°C .. + 70°C ± 0.4 ± 0.8 mA • Wide frequency bandwidth
• No insertion losses
tr Response time 3) @ 90 % of IPN <1 µs • High immunity to external
di/dt di/dt accurately followed > 50 A/µs interference
f Frequency bandwidth (- 1 dB) DC .. 100 kHz • Current overload capability.
General data Applications
• AC variable speed drives and servo
TA Ambient operating temperature - 40 .. + 70 °C motor drives
TS Ambient storage temperature - 50 .. + 85 °C • Static converters for DC motor drives
RS Secondary coil resistance @ TA = 70°C 15 Ω • Battery supplied applications
m Mass 13 kg • Uninterruptible Power Supplies
Standards EN 50155 (UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
1)
Notes : Between primary and secondary + shield
2)
Between secondary and shield
3)
With a di/dt of 100 A/µs.
030204/1
LEM Components w w w.lem.com
Dimensions LT 4000-T/SP11 (in mm. 1 mm = 0.0394 inch)
Front view Left view
Secondary terminals
Terminal 1 : supply voltage + 24 V
Terminal 2 : measure
Terminal 3 : supply voltage - 24 V
Terminal 4 : screen
Connection
Top view
Mechanical characteristics Remarks
• General tolerance ± 1 mm • IS is positive when IP flows in the direction of the arrow.
• Transducer fastening 4 slots ∅ 10.5 mm • Temperature of the primary conductor should not exceed
4 M10 steelscrews 100°C.
Fastening torque max. 11.5 Nm or 8.48 Lb. - Ft.
• Connection of primary 8 holes ∅ 13 mm
• Connection of secondary AMP CPC 13/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.