Hydro Leduc Truck Pumps 07032025
Hydro Leduc Truck Pumps 07032025
FIXED DISPLACEMENT
VARIABLE DISPLACEMENT
2 Contents
XPi series
PA - PAC series
The range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Performances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
TXV series
The range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Why use a variable displacement pump ? . . . . . . . . . . . . . . . . . . . 23
How does it work ? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
VARIABLE Pressure-flow "Load Sensing" control . . . . . . . . . . . . . . . . . . . . . . 25
DISPLACEMENT Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PUMPS Performances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
TXV 130 with through shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TXVA - SAE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
TXV with constant torque control . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Installation and start-up recommendations . . . . . . . 42
Shaft sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
The complete LEDUC product range . . . . . . . . . . . . . 46
Piston pumps specially designed for truck hydraulics 3
XPi
▪ Models from 12 to 130 cc/rev
XPi series
▪ 380 bar continuous working pressure
▪ 420 bar peak pressure
▪ Automatic adjustment to desired direction of rotation
▪ For use on DIN-mount PTO
XAi - SAE
▪ Models from 18 to 63 cc/rev
PA - PAC
▪ Single flow models from 25 to 114 cc/rev
PA - PAC series
▪ Twin flow models from 2x25 to 2x75 cc/rev
▪ Model with two different displacements
▪ 400 bar continuous working pressure
▪ 500 bar peak pressure
▪ Dual direction of rotation
▪ For use on DIN-mount PTO
TXV
▪ Variable displacement pumps with Load-Sensing control
▪ Displacement from 40 to 150 cc/rev
TXV series
TXV
▪ Models from 40 to 150 cc/rev
w i t h Constant Torque ▪ TXV130 with constant torque control - with through shaft version
4 XPi - Presentation
XPi series
the intelligent pump
fixed displacement bent axis design
The compact size envelope of XPi pumps, together with their technology,
means they can be installed in environments with little space available,
and be used at relatively high rotating speeds .
A D VA N TA G E S
CHARACTERISTICS
7 pistons
Innovative plate - barrel synchronisation
use of materials with high mechanical resistance
reinforced sealing
10 models :
from 12 to 130 cc/rev
380 bar continuous working pressure
420 bar peak pressure
max . speed from 1750 to 3150 rpm
Characteristics - XPi 5
XPi series
pressure without with without with
reference pressure 380 bar(2)
< 5 seconds inlet fitting inlet fitting 2ʺ inlet fitting inlet fitting 2ʺ
(cc/rev) (bar) (bar) (rpm) (N.m) (kg) (kg) (N.m) (N.m)
XPi 12 0523820 12 380 420 3150 76 9 .2 9 .65 8 .74 9 .17
XPi 108 0523750 108 .3 380 420 1900 687 14 .95 15 .4 17 .94 18 .48
XPi 130 0523730 129 .8 380 420 1750 827 15 .35 15 .8 18 .73 19 .28
+ 0.2
55 - 0.4 A F
Splined shaft: 8-32-36 80
7 E
DIN ISO 14 - NF 22.131 40
14.5
(DIN 5462)
M12x1.75-6H
25.95 ±0,1
40
Ø 80 - 0.013
80
40°
1.9 ±0.1 Ø 12.75 (4x)
C
37.9 +- 0.2
0.4
D
G3/8
"
B
G
VIEW G
Additionnal bore
H on the shaft
G on request. 18.2 ± 0.05
Ø 8,15 ± 0.05
Shaft bored
through
Pump reference A B C D E F G H
XPi series
800 XPi 130
0
0 50 100 150 200 250 300 350 400 Pressure (bar)
Q (l/min)
250
XPi 130
Cyl x N x ŋvol
200 XPi 108 Q=
1000
XPi 80
XPi 63 With:
150
XPi 50 Q = Flow in l/min
XPi 41 N = Speed in rpm
100 XPi 32 ŋvol = Volumetric efficiency
XPi 25 Cyl = Displacement in cc/rev
XPi 18
50
XPi 12
0
0 500 1000 1500 2000 2500 3000 3500 4000 N (rpm)
These graphs are the results of testwork done in HYDRO LEDUC R&D laboratory, on a specific test bench
with a mineral hydraulic fluid ISO VG46 at 25°C (~100 cSt) - disregarding the volumetric efficiency.
► Volumetric efficiency
% Efficiency at 1000 rpm
100
90 Pressure
0 100 200 300 350 (bar)
8 XPi - Accessories
I N L ET F I T TIN GS F OR X Pi P U MPS
See recommendations of the hosing dimensions on page 40.
For high speeds, please consult .
All XPi pumps are supplied with their inlet fitting.
Please specify required fitting from the choice below when ordering.
xA
xA
E
E
F
DE FL E C TO R TO P R OT E C T S H A F T SEALS
This deflector ensures the protection of the pump shaft seals.
In particular, it protects the pump from projections of dirt from the road in cardan drive installations.
BY-PA S S VA LV E F OR X Pi P U MP S
For XPi pump applications where the pump is driven by a continuous running PTO (PTO which cannot be disengaged), this solution allows
the continuous running of the pump:
▪ without creating problems of fluid overheating;
▪ without affecting pump service life;
▪ with no modifications necessary to the hydraulic circuit of the equipment.
XPi series
When it is activated, the pump operates normally (output flow).
A drain line has to be installed between the By-Pass valve and the hydraulic tank of the vehicule to ensure sufficient oil circulation and a good
cooling into the pump . In any case, the connection to the tank must be done below the oil level .
A
B
C
G
H
118
J
10 XAi SAE version - Presentation
XAi series
the intelligent pump - SAE version
fixed displacement bent axis design
The compact size envelope of XAi pumps, together with their technology, means
they can be installed in environments with little space available,
and be used at relatively high rotating speeds .
A D VA N TA G E S
CHARACTERISTICS
10 models :
7 pistons
from 18 to 63 cc/rev (1.1 to 3.84 cu.in/rev)
original idea for plate - barrel synchronisation
380 bar (5511 psi) continuous working pressure
use of materials with high mechanical resistance
420 bar (6092 psi) peak pressure
reinforced sealing
maximum speed from 2300 to 2650 rpm
4 bolt
flange models
2 bolt
flange models
Characteristics - XAi SAE version 11
XAi 25 0524095 1 .52 (25) 5511 (380) 6092 (420) 2650 117 (159) 22 .38 (10 .15) 23 .36 (10 .6) 7 .11 (9 .64) 7 .43 (10 .07)
XAi 32 0524105 1 .95 (32) 5511 (380) 6092 (420) 2600 150 (204) 26 .34 (11 .95) 27 .67 (12 .4) 8 .81 (11 .95) 9 .15 (12 .4)
XAi 41 0524115 2 .5 (41) 5511 (380) 6092 (420) 2550 192 (261) 26 .45 (12) 27 .45 (12 .45) 8 .85 (12) 9 .18 (12 .45)
(1) At absolute pressure 14,50 psi (1 bar), ISO VG46 fluid at 25°C.
(2) Maximum torque given with a mechanical efficiency at 95%.
XAi 25 0524090 1 .52 (25) 5511 (380) 6092 (420) 2650 117 (159) 22 .71 (10 .3) 23 .70 (10 .75) 7 .19 (9 .75) 7 .53 (10 .21)
XAi 32 0524100 1 .95 (32) 5511 (380) 6092 (420) 2600 150 (204) 26 .68 (12 .1) 27 .67 (12 .55) 8 .92 (12 .1) 9 .26 (12 .55)
XAi 41 0524110 2 .5 (41) 5511 (380) 6092 (420) 2550 192 (261) 26 .78 (12 .15) 27 .78 (12 .6) 8 .96 (12 .15) 9 .29 (12 .6)
XAi 50 0524360 3 .07 (50 .3) 5511 (380) 6092 (420) 2450 234 (318) 26 .89 (12 .2) 27 .89 (12 .65) 9 .45 (12 .81) 9 .80 (13 .28)
XAi 50 0524365
XAi 63 0524125 3 .84 (63) 5511 (380) 6092 (420) 2300 295 (401) 27 .01 (12 .25) 28 (12 .7) 9 .49 (12 .86) 9 .83 (13 .33)
(1) At absolute pressure 14,50 psi (1 bar), ISO VG46 fluid at 25°C.
(2) Maximum torque given with a mechanical efficiency at 95%.
Outlet
1.62 (41.3) A
4.67 (118.5) 6.85 (174)
0.38 (9.65)
3.53 (89.8) 5.75 (146)
Splined shaft SAE B 7/8" 0.63 (16)
13T 16/32DP
M8x1.25-6H M8 x 1.25-6H
0.0008 (Ø101.6)
4.67 (118.5)
3.53 (89.8)
4.00 -0.0000
2x Ø 0.56
40°
( 14.3)
0.79 (20)
D 4x Ø 0.56
C ( 14.3)
1.31 ±0.01 (33.3)
0.31 (7.9)
9/16
"-18
UNF
-2B
B
4.27 (108.5) 4.27 (108.5)
1.81 (46) A
Splined shaft SAE BB 1" 0.38 (9.65)
15T 16/32DP SAE B 4 bolts (SAE J744) SAE B 2 bolts (SAE J744)
2.1
F 3(
54
0.0008 (Ø101.6)
)
4.00 -0.0000
1.08 (27.5)
F
1.50 ±0.01 (38.1)
0.31 (7.9) View from A
XAi 18 0524085 7 .76 (197 .2) 6 .79 (172 .5) 4 .08 (103 .7) 2 .87 (73) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 25 0524095 7 .76 (197 .2) 6 .79 (172 .5) 4 .08 (103 .7) 2 .87 (73) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 32 0524105 8 (203 .2) 7 .03 (178 .5) 4 .28 (108 .7) 3 .03 (77) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 41 0524115 8 (203 .2) 7 .03 (178 .5) 4 .28 (108 .7) 3 .03 (77) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 18 0524080 7 .76 (197 .2) 6 .79 (172 .5) 4 .08 (103 .7) 2 .87 (73) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 25 0524090 7 .76 (197 .2) 6 .79 (172 .5) 4 .08 (103 .7) 2 .87 (73) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 32 0524100 8 (203 .2) 7 .02 (178 .5) 4 .28 (108 .7) 3 .03 (77) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 41 0524110 8 (203 .2) 7 .02 (178 .5) 4 .28 (108 .7) 3 .03 (77) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 50 0524360 8 .45 (214 .7) 7 .48 (190) 4 .65 (118 .2) 3 .4 (86 .5) 1 1/16"-12 UNF-2B SAE B 7/8" 13T-16/32DP
XAi 50 0524365 8 .45 (214 .7) 7 .48 (190) 4 .65 (118 .2) 3 .4 (86 .5) 1 1/16"-12 UNF-2B SAE BB 1" 15T-16/32DP
XAi 63 0524125 8 .45 (214 .7) 7 .48 (190) 4 .65 (118 .2) 3 .4 (86 .5) 1 1/16"-12 UNF-2B SAE BB 1" 15T-16/32DP
350 Cyl x ∆P
C=
62 .8 x ŋmeca
300 XAi 63
With:
XAi 50
250 C = Torque in N .m
XAi 41 Cyl = Displacement in cc/rev
200
∆P = Differential pressure in bar
XAi 32
150 ŋmeca = Mechanical efficiency
XAi 25
100
XAi 18
50
Q (gallons/min)
40
XAi 63 Cyl x N x ŋvol
Q=
35 1000
XAi 50
30 With:
XAi 41 Q = Flow in l/min
25
N = Speed in rpm
XAi 32
20 ŋvol = Volumetric efficiency
XAi 25 Cyl = Displacement in cc/rev
15
10 XAi 18
0
0 500 1000 1500 2000 2500 3000 3500 N (rpm)
These graphs are the results of testwork done in HYDRO LEDUC R&D laboratory, on a specific test bench
with a mineral hydraulic fluid ISO VG46 at 25°C (~100 cSt) - disregarding the volumetric efficiency.
► Volumetric efficiency
% Efficiency at 1000 rpm
100
90 Pressure
0 100 200 300 350 (bar)
14 XAi SAE version - Accessories
I NL ET F I T T I N GS F OR X Ai P U MP S
See recommendations of the hosing dimensions on page 40.
For high speeds, please consult .
All XAi pumps are supplied with their inlet fitting.
Please specify required fitting from the choice below when ordering.
4 5 ° e lb o w fittin gs kit 9 0 ° e lb o w f it t in g s k it
xA
xA
E
E
F
BY-PA S S VA LV E F OR X A i P U MP S
For XAi pump applications where the pump is driven by a continuous running PTO (PTO which cannot be disengaged), this solution allows
the continuous running of the pump:
▪ without creating problems of fluid overheating;
▪ without affecting pump service life;
▪ with no modifications necessary to the hydraulic circuit of the equipment.
Drain
By-pass valve
A drain line has to be installed between the By-Pass valve and the hydraulic tank of the vehicule to ensure sufficient oil circulation
and a good cooling into the pump . In any case, the connection to the tank must be done below the oil level .
Accessories - XAi SAE version 15
4 b o lt fl an g e - S A E J744
Pump reference A B C D E F G H J
XAi 18 / 25 11 .43 (290 .4) 8 .81 (223 .9) 8 .00 (203 .2) 5 .20 (132 .1) 4 .53 (115) 3 .84 (97 .6) 1 1/16"- 16UNF - 2B 2 .13 (54) 4 .25 (108)
XAi 32 / 41 11 .67 (296 .5) 9 .06 (230) 8 .24 (209 .2) 5 .41 (137 .3) 4 .73 (120 .1) 4 .04 (102 .7) 1 1/16"- 16UNF - 2B 2 .13 (54) 4 .25 (108)
XAi 50 / 63 12 .13 (308 .2) 9 .52 (241 .7) 8 .70 (221) 5 .79 (147) 5 .11 (129 .9) 4 .43 (112 .5) 1 1/16"- 16UNF - 2B 2 .13 (54) 4 .25 (108)
A
D
C
H B
J
4.65 (118)
PA | PAC series
piston pumps
fixed displacement in-line design
A D VA N TA G E S
► Of unique design, the PA and PAC pumps offer a robust solution with long service life for high
pressure requirements in truck hydraulics.
► The design means the pumps can rotate either clockwise or counter-clockwise
without any user intervention.
► Like all truck pumps designed by HYDRO LEDUC, this range is fitted with the
latest innovation in terms of sealing:
Front of pump fitted with two shaft seals: externally, a seal capable of resisting the high temperatures
of the gearbox, and internally, a seal adapted to the hydraulic requirements.
A transparent flexible tube fitted between the two seals, to protect these seals from dirt from the road,
and from high pressure water jet during washing of vehicle etc...
C h a r a c t e r i s t i c s - PA | PA C 17
The PA, PAC pump series comprises two ranges, all designed for truck
applications at working pressures up to 5800 psi (400 bar) continuous and
7252 psi (500 bar) peak.
PA - PAC
Series
PA pumps
single flow from 25 to 114 cc/rev
twin-flow from 2x50 to 2x75 cc/rev
two different flows: 75-40 cc/rev
PA C pumps
Series offering the most compact size envelope :
single flow from 40 to 80 cc/rev
twin-flow from 2x25 to 2x40 cc/rev
18 PA | PA C - D i m e n s i o n s
55 A
G
B C
M12x1,75-6H
E
D
80
F
D
80
J (Inlet) K (Outlet) 98
► S i n gle flow
PA 25 0511510 25 - 261 102 126 47 78 64 107 G 1 1/2" G 3/4" 15 17 2200 177
PA 32 0511515 34 - 261 102 126 47 78 64 107 G 1 1/2" G 3/4" 15 17 2000 240
PA 40 0511520 43 - 261 102 126 47 78 64 107 G 1 1/2" G 3/4" 15 17 1750 304
PA 50 0511525 50 - 261 102 126 47 78 64 107 G 1 1/2" G 3/4" 15 17 1650 354
PA 100 0511565 104 - 290 123 138 .8 69 90 69 124 G 2" G 3/4" 23 .5 31 .5 1400 736
PA 114 0511570 114 - 290 123 138 .8 69 90 69 124 G 2" G 3/4" 23 .5 31 .5 1350 807
► Twin-flow - 2 x 3 pi st ons
PA 2 x 50 0511555 52 52 290 123 138 .8 69 90 69 124 G 2" G 3/4" 23 .5 31 .5 1400 736(2)
PA 2 x 57 0511560 57 57 290 123 138 .8 69 90 69 124 G 2" G 3/4" 23 .5 31 .5 1350 807(2)
PA 2 x 75 0516100 75 75 302 126 147 .8 72 .5 90 72 .5 135 G 2" G 3/4" 26 .8 38 .7 1350 1062(2)
PA 75-40 0516810 75 40 302 126 147 .8 72 .5 90 72 .5 135 G 2" G 3/4" 27 .4 38 .7 1350 807(2)
PAC 2 x 25 0511480 25 25 243 102 .5 112 .8 63 78 65 107 G 1 1/2" G 3/4" 16 17 .6 1750 354(2)
PAC 2 x 32 0511485 32 32 243 102 .5 112 .8 63 78 65 107 G 1 1/2" G 3/4" 16 17 .6 1500 460(2)
PAC 2 x 40 0511710 39 39 247 102 .5 116 .3 63 78 65 107 G 1 1/2" G 3/4" 17 21 .3 1350 552(2)
Dimensions in mm .
P e r f o r m a n c e - PA | PA C 19
Torque (Nm)
600 PAC 50
Torque (Nm)
Tw i n - fl ow m od els
PA s e r i e s PA C s e r i e s
Twin flow models PA Twin flow models PAC
1200
600
1000
PA 2x75
PA - PAC
500
Torque (Nm)
Series
800 PA 75-40
400
Torque (Nm)
600 PA 2x57
PA 2x50 300 PAC2x40
400
PAC2x32
200 200
PAC2x25
0 100
0 50 100 150 200 250 300 350 400 450
Pressure (bar) 0
0 50 100 150 200 250 300 350 400 450
Pressure (bar)
P = Hydraulic power in kW
∆P x Q
P= Q = Flow in l/min
600 x ŋglobal
ŋglobal = Volumetric efficiency + mechanical efficiency
Ca lc u la tio n of t or que t o det er m i ne P TO ,
a s a fu n c tio n o f t he di s pl ac em ent and t he pr es su r e C = Torque in N .m
Cyl = Displacement in cc/rev
Cyl x ∆P
C = 62 .8 x ŋ ∆P = Differential pressure at the pump terminals, in bar
meca
ŋmeca = Mechanical efficiency
20 PA | PA C - P e r f o r m a n c e
Q (l/min)
Q (l/min)
100
PA 40 60 PAC 40
80
60 PA 32 40
40 PA 25
20
20
0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500
N (rpm) N (rpm)
Tw i n - fl ow m od els
PA s e r i e s PA C s e r i e s
Twin flow models PA Twin flow models PAC
250 120
200 100
150 80
PAC 2x40
Q (l/min)
Q (l/min)
PA2x75
60 PAC 2x32
100 PA75-40
PA2x57 40 PAC 2x25
50 PA2x50
20
0
0 500 1000 1500 2000 0
0 500 1000 1500 2000
N (rpm)
N (rpm)
► Volumetric efficiency
These graphs are the results of testwork done in HYDRO LEDUC
% Efficiency at 1000 rpm
R&D laboratory, on a specific test bench with a mineral hydraulic 100
fluid ISO VG46 at 25°C (~100 cSt) - disregarding the volumetric
efficiency.
90 Pressure
0 100 200 300 350 (bar)
A c c e s s o r i e s - PA | PA C 21
I NLET F I T T I N GS F OR PA | PA C P UMPS
See recommendations of the hosing dimensions on page 40.
For high speeds, please consult .
Reference A ØB C D E F
ØB
240131 G 1 1/2" 40 60 17 61 77
E
240133 G 1 1/2" 50 60 17 65 82
C
D
240135 G 2" 50 70 17 65 82
ØA
Dimensions in mm .
S t r a i g h t fi tti ng s
Reference A ØB C D E
ØB
240182 G 1 1/2" 40 55 16 52
240067 G 1 1/2" 48 55 16 64 E
240066 G 1 1/2" 60 65 16 67 D C
ØA
240186 G 1 1/2" 63 .5 65 16 67
240183 G 2" 50 65 16 52
PA - PAC
Series
240170 G 2" 60 65 16 70
240201 G 1 1/2" 76 .2 80 16 87
Dimensions in mm .
DEF L E C TO R TO P R OT E C T S H A F T SEALS
This deflector ensures the protection of the pump shaft seals.
In particular, it protects the pump from projections of dirt from the road in cardan drive installations.
TXV series
pumps with
Load Sensing control
variable displacement piston pumps
A D VA N TA G E S
► TXV series pumps are variable displacement with pressure-flow control – called Load Sensing.
They self-regulate to give just the flow required for each movement.
► Specifically designed for the needs of the truck hydraulics market, TXV pumps are particularly
well adapted for applications in:
▪ loader cranes,
▪ forestry cranes,
▪ refuse vehicles,
▪ salt spreaders, snow and ice equipment,
▪ construction equipment vehicles.
► Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.
► TXV pumps are available in 11 models with maximum displacement from 40 to 150 cc/rev.
► Installing a TXV variable displacement pump will transform your hydraulic equipment.
Slow or rapid movements are done with precision, due to the constant adjustment of pump flow rate.
► The pump incorporates a load sensing device to control flow and maximum pressure.
This control device is piloted by a proportional valve which informs the pump of the flow needed for the
different circuits supplied by the pump, independently of pressure.
2 Quick 3 Slow
and precise
1 Slow
and precise
1&3
For slow and precise movements, the pump adjusts its flow to whatever Q
the user needs, whilst also controlling maximum circuit pressure .
TXV series
Oil heating and lamination, and noise level, are considerably reduced
compared to a fixed displacement pump.
Time
The motor driving the pump only provides the power actually
needed by the equipment, thus ensuring:
longer service life of that equipment;
significant gains in energy consumption;
and overall a more environmentally friendly solution .
The proportional movement of
the control lever is perfectly
reproduced by the pump.
2
For rapid movements, the pump supplies the
required flow virtually instantaneously.
24 TXV - How does it work ?
► TXV variable displacement pumps are of axial piston design with 11 pistons, thus ensuring optimal regularity
of flow and a low noise level.
Swashplate
Bleed screw
α max
Pump pilot
pressure line (LS)
Pressure-flow regulation: "Load Sensing" - TXV 25
► Full flow
LS line The proportional valve is fully open, allowing passage of pump flow .
The pressure in the LS line is the same as in the P line .
Hydraulic pressure is the same on either side of the spool .
P line The standby spring holds the spool in its closed position .
The cancellation piston is not supplied with oil .
The swashplate is at maximum angle α: the pump is at full
displacement .
► Flow control
LS Line
As soon as the proportional valve tends to reduce the flow
requested by the user, the pressure drop created allows the pump
displacement setting piston to be piloted .
P line This setting piston automatically adjusts pump displacement to match
the order given by the proportional valve .
TXV pumps are available in 11 models from 40 to 150 cc/rev maximum displacement.
Max. peak
Max.speed
Pump Direction Maximum Max. opera- pressure Torque at Max.speed Overhang
at full displa- Weight
reference of rotation displac.(1) ting pressure (intermittent: 300 bar(2) in stand-by torque(4)
cement(3)
5%)
(cc/rev) (bar) (bar) (N.m) rpm rpm (kg) (N.m)
Drain line Fa
Inlet line Application Splined shaft: 8-32-36
Outlet line
circuit DIN ISO 14 - NF 22.131
Pilot line
Performance - TXV 27
► Torque absorbed as a function of pump output pressure (with a mechanical efficiency considered at 85%)
Torque (N.m)
900
850
800
750
700
650
600
550
TXV40
500 TXV60
450 TXV75
400 TXV92
350 TXV120
300 TXV130*
250 TXV150
200 * TXV with through shaft
150
100
50
0
0 50 100 150 200 250 300 350 400 Pressure (bar)
300
250 TXV40
TXV60
200 TXV75
Q (l/min)
TXV92
150 TXV120
*TXV130
100
TXV150
0
0 500 1000 1500 2000 2500 3000
N (rpm)
Flow as a function of speed, with pump in maximum displacement position and oil level in tank above the pump .
TXV series
These graphs are the results of testwork done in HYDRO LEDUC R&D laboratory, on a specific test bench
with a mineral hydraulic fluid ISO VG46 at 25°C (~100 cSt) - disregarding the volumetric efficiency.
► Volumetric efficiency
Efficiency at 1500 rpm
%
100
90
0 100 200 300 360
Pressure (bar)
28 TXV 40 to 120 - Dimensions
TXV 4 0 TO 1 2 0
331.1
125
276
80
Drain G1/2’’
Max. pressure setting (PC) connected to tank 40
stand-by pressure
55.1 setting
LS G1/4"
9
247.8
F
40
80 f7
80
194
12.75 (4x)
Connection
for pressure gauge G1/4’’
Dimensions in mm .
TXV 40 to 92 G 3/4" 15 19
29
25
G 1"1/2
25 A
G 1"
A
Inlet Outlet
Connection for
pressure gauge G1/4" 28
28
B 36 36 B
CW CCW
► Support device
TXV 1 3 0 - 1 5 0
321.1 127
266 80
Drain G1/2" 40
Maximum pressure setting to be connected to tank
277
40
F
Ø 80 f7
219
80
Ø 12,75 (4x)
Connection for
pressure gauge G1/4"
Dimensions in mm .
Inlet
Connection for
pressure gauge G1/4"
A B
32
CW CCW
► Support device
TXV series
TXV 1 3 0 T H R OU GH S H A F T P U MP
The TXV 130 pump exists in a “through shaft” version .
With side porting for inlet and output, this “through shaft” TXV 130 configuration means any LEDUC TXV pump, or fixed displacement XPi
or PA pump, can be mounted on the back .
The maximum displacement of the “through shaft” TXV 130 can be factory set, on request, between 60 and 110 cc/rev on request.
It is important to check that maximum torque to be transmitted by the shaft of the “through shaft” TXV 130 does not exceed 900 N .m .
A closing plate must be used when using the pump alone (see page 37) .
Connection for
pressure gauge G1/4"
27
M10x1.5-6H (2x)
Depth 15mm
15 to attach support device
382.6
327.5
Drain G1/2" to be Interface to mount TXV, XPi, PA pumps
Maximum pressure setting connected to tank
(splines 8-32-36 DIN ISO 14 - NF E 22.131)
E F
228
57.1
127
80 80
40 40
LS G1/4"
Outlet G1"
Interface to mount
TXV, XPi, PA pumps
M12x1.75-6H
40
80
Ø 12.75 (4x)
TXV 1 3 0 T H R OU GH S H A F T P U MP
View from F (see p.30)
CW CCW
► Support device
The support device for the pump must be fixed to the same part which the pump is mounted on (see diagram below) and has to be designed
to avoid strain on the pump flange.
Support device
C C
Example of two TXV pumps. Example of TXV with a PA pump. TXV series
C = 900 N .m
C
That is, the sum of torque for both pumps must be < 900 N .m .
Please consult our Technical Department for advice regarding your installations .
32 T X VA S A E v e r s i o n - C h a r a c t e r i s t i c s
TXVA series
variable displacement
piston pumps
SAE version
► Characteristics
Max.
Max. peak
Maximum Torque at speed at
Max. pressure Max. speed Overhang
Direc- operating 300 bar full Weight
Pump displacement(1) (intermittent: in stand-by torque(4)
tion of pressure (4350 psi)(2) displace-
ref. 5%)
rotation ment(3)
cu.in/rev (cc/rev) psi (bar) psi (bar) lbf ft (N.m) rpm rpm lbs (kg) lbf ft (N.m)
TXVA CC
4 .60 (75) 5800 (400) 6090 (420) 310 (420) 2000 3000 64 (29) 26 (35 .2)
75 CCW
TXVA CC
5 .60 (92) 5500 (380) 5800 (400) 380 (515) 1900 3000 64 (29) 26 (35 .2)
92 CCW
(1) TXV pumps can be set for smaller maximum displacements (see page 39) .
(2) For a mechanical efficiency at 85%.
(3) Higher speed - at full displacement - possible depending on flow required : please contact us.
(4) Value of the overhang torque of the only pump .
TXVA pump
Displacement 75 92 ...
Clockwise rotation (CW) R
Direction of rotation
Counterclockwise rotation (CCW) L
SAE C - 2 bolts C1
Flange
SAE C - 4 bolts C2
Splined
14T 12/24 DP - SAE C S1
SAE J744
Shaft end
Keyed
Ø1 1/4" UNF 2A - SAE C K1
SAE J744
450 45
40
400
35
350
30
300 TXVA 75
25
TXVA 75 TXVA 92
250 20
TXVA 92
200 15
150 10
5
100
0
50 0 500 1000 1500 2000 N (rpm)
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Pressure (psi)
► Dimensions
14T 12/24DP
3.76 (95.5)
M8x1.25-6H
Ø 5.00 (Ø126.97)
4.51 (114.5)
5.75 (146)
2 x Ø 0.79 (Ø 20)
3.88 (98.5)
1.10 (28)
4 x Ø 0.56 (Ø 14.3)
U1/G1 U1/G1
4.92 (125) 4.92 (125)
2.20 (55.9)
0.51 (13)
K1 0.5 (12.7) R L
G1 : G3/4''
0.98 (25)
0.59 (15)
0.25 (6.45)
1.38 (35.16)
Ø 5.00 (Ø 126.97)
0.25 (6.45)
0.31 (7.94)
0.59 (15)
Ø 1.25 (Ø 31.73)
0.98 (25)
1.14 (29)
U1 : 1-7/8''-12UN-2B 2x 3/8"-16UNC-2B
G1 : G1-1/2’’ depth 0.59 (15) U1 : 1-7/8''-12UN-2B
1.89 (48) 0.31 (7.87) G1 : G1-1/2’’
PC | Co n stan t P ressure
The constant pressure regulator maintains the pressure within a hydraulic receiver. As soon as the set pressure is reached, the pump's flow
adjusts automatically to match the receiver's consumption. This arrangement prevents overheating and power consumption for all pressure
maintenance applications .
Examples:
IMPORTANT::
IMPORTANT
• Hydraulic press Without
Sansfurther specifications
précision in the order:
autre à la commande :
• Compression molds PC
PCréglée
set atà100
100bar .
bar .
Flow Q
P
PC
Service
pressure P
T (drain G1/2'')
T X VA S A E Ve r s i o n - C o n t r o l s 35
Proportional valve
LS
Flow Q
P
A
Stand-by
PC
Service
LS Pressure P
(U1: 9/16''-18UNF-2B
G1: G1/4'')
T drain: (U1: 9/16''-18UNF-2B
G1: G1/2'')
TXV series
36 TXV pumps range with constant torque control
A D VA N TA G E S O F T H E C O N S TA N T T O R Q U E R E G U L AT I O N
► TXV pumps with constant torque control which ensures regulation to maintain Pressure X Flow = Constant
► Control device available for the entire range of TXV pumps from 40 to 150 cc/rev., including the TXV130 model
with through shaft
► Maximum torque between 90 and 700 Nm depending on models
► Torque/power adjustment screw
► Characteristics
Max. peak Max. speed Max. speed
Max. Max. Max.
pressure at full Overhang
Direction displace- operating torque in stand-by Weight
Pump Reference (1) (intermittent displace- torque
ment pressure range(3) mode
of rotation 5%) ment(2)
(cc) (bar) (bar) (daN.m) (rpm) (rpm) (kg) (N.m)
P002685 CW
TXV 40 40 400 420 9 to 43 .5 3000 3000 25 .8 34
P002686 CCW
P002673 CW
TXV 60 60 400 420 9 to 43 .5 2600 3000 25 .8 34
P002674 CCW
P002683 CW
TXV 75 75 400 420 9 to 43 .5 2000 3000 25 .8 34
P002684 CCW
P002681 CW
TXV 92 92 400 420 9 to 43 .5 1900 3000 25 .8 34
P002682 CCW
P002441 CW
TXV 120 120 380 400 12 to 56 .5 2100 3000 25 .8 34
P002442 CCW
P002763 CW
TXV 130 130 365 380 13 to 60 .5 2100 3000 28 38 .6
P002764 CCW
P002765 CW
TXV 150 150 310 330 15 to 70 2000 3000 28 .2 38 .6
P002766 CCW
TXV 130 P002741 CW
(through shaft 130 365 380 13 to 60 .5 1900 3000 31 .1 47 .4
version) P002743 CCW
(1) The pumps can be set for a lower maximum displacement .
(2) Higher speed possible - at full displacement - depending on flow required : please contact Customer Service.
(3) Required torque setting to be specified on order.
250
350 LS
300 200 P
250
A
Torque (Nm)
150
Flow (l/min)
200
150 100
Torque
100
Flow
50
50
T
0 0
0 50 100 150 200 250 300 350 400
Pressure (bar)
Dimensions 37
55,1
55,1
9
262,30
Ø 80 f7
227
284
219
247,8
194
Pressure gauge
connection G1/4" 127 Pressure gauge
connectionG1/4"
80
125
40
80
40
M12x1.75-6H
M12x1.75-6H
40
40
80
80
Ø12,75 (4x)
Ø12,75 (4x)
382,6
327,5
255,5 127
80 80
Standby pressure Maximum pressure Drain G1/2"
Torque setting setting setting (PC) LS G1/4" to be connected to tank 40 40
M12x1.75-6H
292,5
E F
40
281,5
40
80 f7
80
80
228
TXV series
12,75 (4x)
.
57,1
Inlet G1 1/2"
View from E View from F
(Shaft side) (Hub side)
Connection for
Splined hub: 8-32-36
pressure gauge G1/4" DIN ISO 14 - NF 22.131
Dimensions in mm .
38 TXV - Accessories
I NL ET F I T T I N GS F OR T X V P U MP S ( opt ional)
See recommendations of the hosing dimensions on page 40.
For high speeds, please consult .
ØB
E
St r a i gh t fi tti ng s
Reference A ØB C D E Pump type C
D
240182 G 1 1/2" 40 55 16 52 TXV
ØA
240067 G 1 1/2" 48 55 16 64 TXV
240066 G 1 1/2" 60 65 16 67 TXV ØB
Dimensions in mm . D C
ØA
TXV - Accessories 39
► Technical characteritics
9/16-18 UNF
9/16-18 UNF
G 1/4″
G 1/4″
29.50 29.57
SE A L + F I LT E R | L E D U C C OD E K000028
The LS filter protects the TXV's Load Sensing valve against contaminations
coming from the hydraulic circuit .
Mounted as standard on all TXV pumps .
TXV series
Deflector
CARDAN PLATE - DIN 90 and DIN 100 Splines 8-32-36
NF E 22-131
H
The cardan plate enables the pump shaft to be connected to a cardan shaft
with interface as on drawing on the right .
Note: the maximum admissible torque is limited by the drive shaft.
ØG
ØC
ØA
ØB
LEDUC
Type ØA ØB C D E F ØG H D E
code F
DIN 90 056315 90 47 43 2 10 62 55 15
DIN 90 4 holes Ø8.5 on Ø74.5
DIN 100 0519040 100 57 43 2 10 64 55 15
DIN 100 4 holes Ø10.5 on Ø84
Dimensions in mm.
40 Accessories for TXV pumps
► Technical characteristics
► Dimensions
A
37 max.* 91.50
45
L 15.5 P
51.50
51.50
56
32
56
LS
G1/4"
8.50
15 33
15
A 57
G1/4" 30
* This lenght varies depending on the setting of L ( see bottom of this page).
► Schematics
Proportional valve
P
LS = LS signal
LS P = Pressure
T = drain
T
Circulation valve
6 L
P
5,5
5
4,5 LS
4
3,5
3 T
2,5
2
15 16 17 18 19 20 21 L (mm)
Unscrew completely, loosen nut and screw to obtain dimension X on graph below, X
and the corresponding displacement (see figure).
▪ For TXV 150 : 1 turn of the screw changes the displacement by 7.5 cc.
▪ For TXV 130 : 1 turn of the screw changes the displacement by 6.5 cc.
▪ For TXV 120: 1 turn of the screw changes the displacement by 9 cc.
▪ For TXV 92 to TXV 40: 1 turn of the screw changes the displacement by 8 cc.
110
100
90
80
70
60
50
40
30
24 26 28 30 32 34 36 38 40 42 44 46 48 50
Dimensions X (mm)
SE TT I N G O F T H E R E GU L AT ION
► Stand-by
TXV pumps are supplied as standard with standby pressure set at 30 bar .
Sérieseries
TXV
► Maximum pressure
TXV
Cancellation pressure PC of the pump must be the same as the maximum working pressure of your installation . This PC pressure should be
specified in the order. If no PC setting is specified, pumps will be supplied with PC set at 100 bar.
► Response time
Response time of TXV pumps, from zero flow up to full flow, can be adapted.
For further information or advice, please contact our Customer Service Department .
42 Installation and start-up recommendations
Generally, hydraulic pumps perform better when the tank is above the The supply line should be dimensioned to ensure fluid speed between
pump . LEDUC pumps can also operate with oil level beneath the pump . 0.5 and 0.8 m/second.
Choose as direct a supply line as possible, avoiding sharp bends .
For further information on such installations, please contact our
Technical Department .
Q = Flow (l/min)
Correct inlet conditions are between 0 .8 to 2 bar absolute pressure . 300 d = Ø inner diameter v = fluid speed
of inlet line (m/s)
200 (mm)
The tank should preferably have a separation between inlet side and
return. This avoids fluid emulsion and the introduction of air into the
0,4
150
Suction
0,5
70
hydraulic circuit . 100 60
90 50
80
70
Ensure also that the suction is not from the very bottom of the tank, 60
40 1,0
30
so as to protect the pump from any deposits (particles) . 50
1,5
25
40
20 2,0
Return
30
15 2,5
3,0
20
Filling filter and venting 10 4,0
9
Clogging indicator 15 8 5,0
Outlet
7
Return filter 6,0
6 7,0
10
Max. level 5 8,0
RETURN 4
Min. level
6
Drain return
Plunging return
► Filtration
The service life of the pumps is highly dependent on the quality of the
hydraulic fluid and level of cleanliness.
Suction raised to prevent
suction of contamination in Separating plate
the bottom of tank Return / Inlet
Opening for oil passage
We recommend the following minimum cleanliness:
(the farther as possible from return)
Ball valve with low ∆P
PUMP INLET
0.8 bar min. absolute We recommend using of a return filter of 20 µm absolute maximum.
2 bar max.
► Drain pressure
It is essential to drain the pump, to avoid excessive pressures on the
shaft seal . Maximum acceptable internal pressure depends on pump
rotating speed .
Ensure that the working pressure in the housing does not exceed 2
bar, whatever the pump rotation speed and the viscosity of the fluid .
Other operating may be possible; please consult our Technical
Department .
43
Before start-up, the pumps should be filled with clean hydraulic oil. If cardan shaft drive: check the quality and correct installation of the
(minimum 50%). cardan shaft .
LEDUC pumps are not designed to withstand any axial or radial load
on the pump shaft . Check your installation conforms to this require-
ment .
For pumps with a greater overhang torque than that accepted by the
PTO, it is recommended to use an elastic support device to support
the weight of the pump .
This support has to be designed to
avoid strain on the pump flange .
► Fluid
Use a mineral hydraulic oil type HLVP according to DIN 51502 (or HV
according to ISO 11158) with viscosity between 10 and 400 cSt .
It is in this viscosity range that the pump keeps its volumetric
characteristics .
We do not sell the elastic support.
The optimal viscosity range is between 20 and 30 cSt . It must be suitable for the environment of the pump assembly.
A maximum viscosity of 1000 cSt is accepted when starting up at low
speed and without pressure . ► Start-up
If you wish to use other fluids, please consult our Customer Service ▪ Open the supply valve if there is one.
Department . ▪ Check the valve is in “back to tank” position.
Maximum temperature of fluid in the pump should not exceed 80°C. ▪ Start up at low speed, or by successive starts/stops.
Fluid viscosities as a function of temperature ▪ Let the pump run for one to two minutes, and check that the flow
10000 is regular .
▪ Check the pump is running correctly, with neither vibrations nor a
1000 normal noise .
mm2/s or cSt
► Maintenance
3.0
LEDUC pumps designed for truck hydraulics are all fitted with
reinforced sealing comprising:
WARNING : if you notice any trace of oil in the tube, the tightness
of PTO-pump should be checked immediately .
Make a siphon with the tube so as to avoid any Avoid attaching the tube to any parts which may move,
introduction of dirt from road, and water or damp from this could lead to it being damaged or torn off .
high pressure washing of vehicle .
Avoid any pinching or folds in the tube when fixing
Put the end of the tube downwards, or in a place sheltered from it in place .
any projections.
Make sure the end of the tube is not blocked .
Fix the tube in place using a collar/clip.
i INFORMATION
HYDRO LEDUC stresses that on non-sealed PTO installations it is the Example of tube attachment
hydraulic pump which ensures the sealing of the vehicle gearbox .
This is why HYDRO LEDUC offers tried and tested solutions approved
by vehicle manufacturers .
Note in particular the pump - PTO sealing has to be done via the seal
C002510 supplied with the pump .
NOTES
46 The LEDUC range
M/MA
MSI
X Pi/XAi T X VA
TXV
Va r i a b l e
M o to r
W/ WA
PA/PAC/PAD
HYDRO LEDUC offers 3 ranges of piston The W series consists of fixed displacement Axial Piston Motors with Constant and
pumps perfectly suited for truck applications, pumps, and the TXVA series consists of Variable Displacement
mountable on power take-off . variable displacement pumps . These pumps
are capable of operating at high pressures Models from 5 to 180 cc/rev
while occupying minimal space . DIN and SAE Versions
Fixed displacement from 12 to 130 cm³/rev Constant Displacement, Motors without
Fixed displacement, dual flow, from 2x25 to Leak Oil Connection Special Version .
2x75 cm³/rev ► W Series (ISO) and WA Series
Variable displacement, with LS (load (SAE)*
sensing) control, from 40 to 150 cm³/rev.
Fixed displacements from 5 to 180 cm³/
rev
Flanges according to ISO 3019/2 or
SAE standards
Shafts according to DIN or SAE
standards
► TXVA Series
H Y D R O P N E U M AT I C A C -
C U M U L AT O R S MICROHYDRAULIC
µ
A passion for hydraulics
HYDRO LEDUC AB
Betongvägen 11
461 38 TROLLHÄTTAN
SWEDEN
Tel. + 46 (0) 520 10 820
HYDRO LEDUC BV
Ericssonstraat 2
5121 ML RIJEN
THE NETHERLANDS
Tel. +31 161 747816
make it simple
HYDRO LEDUC
SAS with capital of 4 065 000 €
EORI FR31902742100019
RC Nancy B 319 027 421
www.hydroleduc.com
[email protected]
EN_TRUCK PUMPS_20250703