Kelman Dga 900 Multitrans Brochure en 230329 Grid Gea 33192 A4 r002 HR

The Kelman DGA 900 MULTITRANS is an advanced on-line monitoring solution for transformer health, capable of measuring nine gases and moisture levels across three single-phase transformers. Utilizing photo-acoustic spectroscopy technology, it provides high precision and repeatability, enabling frequent sampling and integration with asset management software for comprehensive diagnostics. Key benefits include modular architecture, remote monitoring capabilities, and minimal maintenance requirements, making it a cost-effective choice for managing transformer conditions.

Uploaded by

johannes.riedel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views2 pages

Kelman Dga 900 Multitrans Brochure en 230329 Grid Gea 33192 A4 r002 HR

The Kelman DGA 900 MULTITRANS is an advanced on-line monitoring solution for transformer health, capable of measuring nine gases and moisture levels across three single-phase transformers. Utilizing photo-acoustic spectroscopy technology, it provides high precision and repeatability, enabling frequent sampling and integration with asset management software for comprehensive diagnostics. Key benefits include modular architecture, remote monitoring capabilities, and minimal maintenance requirements, making it a cost-effective choice for managing transformer conditions.

Uploaded by

johannes.riedel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Grid Solutions

Kelman DGA 900 MULTITRANS


On-line DGA & Moisture for 3 x Single Phase Cutting Edge DGA
Transformer • Nine gases plus moisture in a single monitor
• Automated headspace gas extraction and state
Knowledge of the condition of transformers is essential for all electrical networks and on-line
of the art photo-acoustic spectroscopy (PAS)
monitoring of transformers is an increasingly vital component of successful asset management measurement technology
programs. The comprehensive information provided by the Kelman™ DGA 900 MULTITRANS not only
• No carrier or calibration gases required
allows expensive failures to be avoided but enables asset capabilities to be maximized.
• Long service life with minimal maintenance
The DGA 900 MULTITRANS offers discrete multigas on-line DGA and moisture monitoring across three
adjacent single phase transformers, enabling a very cost effective monitoring solution. Utilizing photo-
acoustic spectroscopy (PAS) measurement technology, well suited to field application, it provides
laboratory challenging levels of precision and repeatability. Full 9 gas oil sampling and analysis can be
Ease of Use
performed as often as every hour on a single tank and up to once every three hours if all three possible • Easy installation: no outages required reducing
oil tanks are connected. expense and inconvenience for user
• No consumables and minimal maintenance
Through close integration with GE’s powerful Perception™ software suite and/or user’s own software,
reduces running costs and site visits
historian and SCADA systems, the MULTITRANS offers full gas-in-oil trending, analysis and diagnostic
capabilities including various diagnostic methods prescribed by international standards. • Extensive remote communications options and
protocols available (including IEC® 61850)
Key Benefits • Sampling frequency is user-configurable, up to
• Modular and retrofittable architecture using selectable standard add-on cards once per hour

• Provides extensive remote insight into transformer condition and safe operation • Can be connected to normal AC power or
protected DC supply
• Enables correlation of data for validation and in-depth fault analysis
• Supports new lower flammability ester based oils
• Graphical presentation using built-in web-page based HMI and local color screen
as well as mineral insulation oils
• Full integration with GE’s acclaimed Perception™ Fleet asset management software
• From the only vendor with 15 years PAS experience and installed base of >15,000 units
• Remote insight into transformer condition enables rapid action to correct any issue detected
Configurable Alerts
• Two alarm levels (one for Caution and one for
• Discrete measurement of all fault gases facilitates full remote diagnostic without having to go to
Alarm) can be set to show increasing severity
site and take an oil sample
• Sunlight visible front panel LED arrays
• Cost effective solution for 3 adjacent single phase transformer configuration
• Six user configurable alarm relay contacts
Applications • Caution and alarm modes can be used to
Knowledge of the condition of transformers is essential for all electrical networks and on-line automatically increase sampling frequency
monitoring of transformers is an increasingly vital component of successful asset management
programs. The information provided by multi-gas on-line DGA allows valuable asset capabilities to be
maximized and expensive failures to be avoided.
Integrated Solution
• Integrates to Perception Fleet to provide health/
MULTITRANS is best suited for monitoring large, system critical or already compromised transformers,
risk ranking of the monitored transformers
arranged in a 3 single phase tank configuration, with a view to extending asset life, preventing
compared to other fleet assets
unexpected failure and operating on a condition based maintenance schedule.
Technical Specifications
MEASUREMENTS
Technology Frequency
Automated head-space gas extraction. Configurable from once per hour to once every 4 weeks.
Photo-acoustic spectroscopy (PAS) gas measurement. Faster sampling automatically triggered upon alert level reached.
Thin film capacitive moisture sensor. "Rapid Mode" provides a rapid indication of the evolution of the
Immersed fiber optic oxygen sensor. gasses indicated below in ~30 minutes.
Range
LDL UDL Accuracy* Repeatability Response Time*** Rapid Mode
Hydrogen (H₂) 5 5,000 ppm ± LDL or ±5 % <3% > 90 % •
Carb. Monox. (CO) 1 50,000 ppm ± LDL or ±3 % <2% > 95 % •
Methane (CH₄) 2 50,000 ppm ± LDL or ±3 % <2% > 95 %
Acetylene (C₂H₂) 0.5 50,000 ppm ± LDL or ±3 % <2% > 95 % •
Ethylene (C₂H₄) 1 50,000 ppm ± LDL or ±3 % <2% > 95 %
Carb. Diox. (CO₂) 20 50,000 ppm ± LDL or ±3 % <3% > 95 % •
Ethane (C₂H6) 1 50,000 ppm ± LDL or ±3 % <2% > 95 %
Oxygen (O₂) 100 50,000 ppm ± LDL or ±5 % <2%
Nitrogen (N₂) ** 10,000 100,000 ppm ± LDL or ±15 %
Moisture (H₂O) 0 100 % RS (in ppm) ± 3 % ppm <3% •
*Whichever is greater. Accuracy quoted is the accuracy of the detectors during calibration. Gas-in-oil measurement may be affected by oil type and
condition. Repeatability as measured from final production test data.
** N₂ value is calculated and available on free-breathing transformers only.
*** Time Response (typical): % of value after 1 measurement cycle.
Location of maximum 3 x add-on cards

FEATURES ADD-ONS † ENVIRONMENT


Display Option – Bushing Monitoring 3 Phase Transformers Operating Conditions
4 x Sunlight visible LED arrays Up to 6 x Bushing adaptors ordered separately
Ambient -40 °C to +55 °C (-40 °F to +131 °F)
Backlit 7” inch color resistive touch screen (800 x 480) Standard: Bushing HV (3 Bushings) temperature
Embedded secure webserver (https) Option: Bushings HV & LV (6 Bushings) Ambient 0-95 % RH, non-condensing
humidity
Analogue Input Option: Inputs for phase to ground reference voltage
1 x Standard for split core load CT sensor Oil temp at -20 °C to +120 °C (-4 °F to +248 °F)
All sensors supplied unless noted valve††
Digital Output MECHANICAL Enclosure
6 x Standard customer programmable dry contact relays (type Analysis Unit Hub Unit
C, SPDT), NO/NC, 10A @250Vac resistive load, 8A @30Vdc IP56 certified
Dimensions 600 x 484 x 330 mm 600 x 380 x 330 mm
resistive load Standard: Powder coated marine grade 2 mm aluminium
23.6 x 19.1 x 13.0 in 23.6 x 15.0 x 13.0 in (RAL9002)
1 x Standard service alarm relay
Weight 32 kg / 70.5 lb 18.5 kg / 40.8 lb Option: Unpainted 316 Stainless Steel
1 x Standard watchdog relay
POWER REQUIREMENTS †Bushing monitoring will be available in future releases
Digital Communications / Protocols
AC Nominal 100-240 Vac (Range 85-264), 4A ††Based on testing carried out using Voltesso™ 35 mineral
1 x Modbus® over RS485 / TCP/IP as standard
DC Nominal 100-250 Vdc (Range 90-300) oil, over a ¼” pipe run of 10 metres or less from oil supply or
1 x Standard 1Gb Ethernet (RJ45) return valve to monitor connection point and on transformer
OPTIONS oil supply valve volumes of 200 ml or less. For oil temperatures
Option: DNP3.0 over RS485 or TCP/IP
Mounting stand and Sun canopy colder than -20 ºC GE recommends the use of heat trace
Option: IEC 61850 Edition 2 cabling on piping
Longer umbilical cable between units
Option: ST/SC Multi-mode fiber converters
Option: GPRS/UMTS/HSPA+ modem

Grid Solutions
Lissue Industrial Estate East
Unit 1, 7 Lissue Walk
Lisburn BT28 2LU
United Kingdom
Tel: +44 (0) 2892 622915

GEGridSolutions.com
All Rights Reserved. GE, the GE monogram, Kelman and Perception are trademarks of the General Electric
Company.
Modbus is a registered trademark of Schneider Automation, Inc. IEC is a registered trademark of
Commission Electrotechnique internationale. Voltesso is a registered trademark of Exxon Mobil
Corporation.
GE reserves the right to make changes to specifications of products described at any time without notice
and without obligation to notify any person of such changes.
For further information scan here Copyright 2023, General Electric Company. GEA-33192-(E)
English
230330

You might also like