0% found this document useful (0 votes)
9 views4 pages

Gs e Yokogawa Yta70 Temperaturtransmitter Specifikationer Gs01c50c03 00en

The YTA70 is a head mount temperature transmitter that converts various input types, including thermocouples and RTDs, into a 4 to 20 mA DC signal and supports HART® communication protocol. It features selectable HART protocol revisions, accuracy specifications, and a range of operational parameters such as ambient temperature limits and response time. The device is designed for use in various industrial applications and complies with relevant safety and EMC standards.

Uploaded by

Huan Trinh Van
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views4 pages

Gs e Yokogawa Yta70 Temperaturtransmitter Specifikationer Gs01c50c03 00en

The YTA70 is a head mount temperature transmitter that converts various input types, including thermocouples and RTDs, into a 4 to 20 mA DC signal and supports HART® communication protocol. It features selectable HART protocol revisions, accuracy specifications, and a range of operational parameters such as ambient temperature limits and response time. The device is designed for use in various industrial applications and complies with relevant safety and EMC standards.

Uploaded by

Huan Trinh Van
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

<<Contents>> <<Index>>

General YTA70
Specifications Temperature Transmitter

GS 01C50C03-00EN

The YTA70 is a head mount type of temperature


transmitter that accepts thermocouple, RTD, ohms
or DC milivolts input and converts it to a 4 to 20 mA
DC signal for transmission. The YTA70 conforms to
the standard DIN form B head mounting. The YTA70
supports HART® communication protocol.
HART protocol revision is selectable from HART 5 or
HART 7, and HART 7 features long tag number up
to 32 characters, enhanced burst mode and event
notification, and command aggregation function.

 STANDARD SPECIFICATIONS
Accuracy Supply & Load Requirements:
See Table 1. on page 3. Voltage
Cold Junction Compensation Accuracy 8 to 35 V DC for operation
(For T/C only) (8 to 30 V DC for Intrinsically safe type)
±1°C (±1.8°F) 13.8 to 35 V DC for digital communication
Ambient Temperature Effects Load Resistance
See Table 1. on page 3. 0 to (E-8)/0.0236 [Ω]
Power Supply Effects where E is power supply voltage.
±0.005% of FS per Volt 250 to 600 Ω for digital communication
EMC Conformity
EN61326-1 Class A, Table 2
EN61326-2-3
EU RoHS Directive 600
Applicable standard: EN IEC 63000 E-8
R=
Input Type, Span and Range External 0.0236
Digital
Selection from thermocouples (T/Cs), 2-, 3-, and 4- load Communication
wire RTDs, ohms and DC milivolts. resistance range
See Table 1 on page 3.
Maximum Zero offset 250
±50% of selected maximum value R (Ω)
Input Resistance (for thermocouples, mV)
10 MΩ, or 3 kΩ at power-off
Input Lead Wire Resistance (for RTD, ohm)
8.0 13.8 21.8
5 Ω per wire or lower
(up to 50 Ω per wire is configurable with reduced Power supply voltage E (V DC)
F01E.ai
measurement accuracy)
Sensor Burnout Figure 1. Relationship Between Power Supply
High (NAMUR NE43 upscale), Low (NAMUR NE43 Voltage and External Load Resistance
downscale), or value within 3.5 to 23 mA
Material
Output Polycarbonate
Two wire 4 to 20 mA DC
Color of the case
Response Time Red
1 to 60 seconds programmable
Mounting
Ambient Temperature Limits DIN form B head mounting
(Option code may affects limit)
Terminals
-40 to 85°C (-40 to 185°F)
M3 screws
Ambient humidity limits
Weight
0% to 95% RH (non-condensation)
50 g (0.11 lb)
Isolation
Input/output isolated to 1500 V AC.

Yokogawa Electric Corporation GS 01C50C03-00EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan ©Copyright Mar. 1999
Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 15th Edition July 2021
<<Contents>> <<Index>> 2
 MODEL AND SUFFIX CODES
Model Suffix Codes Descriptions
YTA70 . . . . . . . . . . . . Temperature Transmitter (Head Mount Type)
Output Signal -J. . . . . . . . . . 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1
Optional /KS2*2 ATEX Intrinsically safe approval
Specifications Applicable standard: EN IEC 60079-0, EN 60079-11
Certificate: KEMA 10 ATEX0027 X
II 1 G Ex ia IIC T6...T4 Ga
II 2 D Ex ia IIIC Db
Amb. temp.:
For EPL Ga:
The relation between ambient temperature range and temperature class:
Pi= 0.84W Pi= 0.75W
Temperature Class
Ambient temperature range Ambient temperature range
T6 -40°C to +47°C -40°C to +50°C
T5 -40°C to +62°C -40°C to +65°C
T4 -40°C to +85°C -40°C to +85°C
For EPL Db:
The surface temperature of the outer enclosure is + 20 K above the ambient temperature,
determined without a dust layer.
Ambient temperature range: -40 to 85°C
Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W or 0.75W, Ci=1nF, Li=0μH
Sensor circuit: Uo=9.6V, Io=28mA, Po=67.2mW, Co=3.5µF, Lo=35mH
/SS2*2 IECEx intrinsically safe, FM intrinsically safe/Nonincendive, and ATEX intrinsically safe approval
combination (For ATEX intrinsically safe approval, see /KS2.)
[FM Intrinsically safe/Nonincendive approval]
Applicable standard: Class 3600, Class 3610, Class 3611, Class 3810, ANSI/ISA-60079-0, and
ANSI/ISA-60079-11
Intrinsically safe for Class I, Division 1, Groups A, B, C, and D
Supply: Vmax=30V, Imax=120mA, Pmax=0.84W, Ci=0μF, Li=10μH
Nonincendive for Class I, Division 2, Groups A, B, C, D
Hazardous (Classified) indoor/outdoor (TYPE 4) Locations
Supply: Vmax=35V, Ci=0μF, Li=10μH
Amb. temp.: T6 Ta=60°C, T4 Ta=85°C
[IECEx intrinsically safe approval]
Applicable standard: IEC 60079-0, IEC 60079-11
Certificate: IECEx KEM 10.0086X
Ex ia IIC T6...T4 Ga
Ex ia IIIC Db
Amb. temp.:
For EPL Ga:
The relation between ambient temperature range and temperature class:
Pi= 0.84W Pi= 0.75W
Temperature Class
Ambient temperature range Ambient temperature range
T6 -40°C to +47°C -40°C to +50°C
T5 -40°C to +62°C -40°C to +65°C
T4 -40°C to +85°C -40°C to +85°C
For EPL Db:
The surface temperature of the outer enclosure is + 20 K above the ambient temperature,
determined without a dust layer.
Ambient temperature range: -40 to 85°C
Supply/output circuit: Ui=30V, Ii=120mA, Pi=0.84W or 0.75W, Ci=1nF, Li=0μH
Sensor circuit: Uo=9.6V, Io=28mA, Po=67.2mW, Co=3.5µF, Lo=35mH
*1: Output signal code J is HART 5 or HART 7 selectable model. Specify HART 5 or HART 7 when ordering.
*2: Even if the option code is the same, the explosion-proof specifications (Ex marking, Amb.temp., etc.) are different, so
please check the specifications when ordering.

All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C50C03-00EN July 1, 2021-00
<<Contents>> <<Index>> 3
Table 1. Input type, range and accuracy

Sensor Input range Minimum Span Accuracy Temp. effects/10°C


Standard
Type °C °F °C °F (value whichever is greater) (value whichever is greater)
<T/Cs>
B 400 to 1820 752 to 3308 200 360 ±0.1% of span or ±1.0°C ±0.05% of span or ±1.0°C
E -100 to 1000 -148 to 1832 50 90
J -100 to 1200 -148 to 2192 50 90
±0.1% of span or ±0.5°C ±0.05% of span or ±0.25°C
K IEC60584 -180 to 1372 -292 to 2502 50 90
N -180 to 1300 -292 to 2372 100 180
R -50 to 1760 -58 to 3200 200 360
±0.1% of span or ±1.0°C ±0.05% of span or ±1.0°C
S -50 to 1760 -58 to 3200 200 360
T -200 to 400 -328 to 752 50 90
L DIN43710 -100 to 900 -148 to 1652 50 90 ±0.1% of span or ±0.5°C ±0.05% of span or ±0.25°C
U -200 to 600 -328 to 1112 75 135
GOST
Lr -200 to 800 -328 to 1472 50 90
3044-84
±0.1% of span or ±1.0°C ±0.05% of span or ±1.0°C
W3 ASTM 0 to 2300 32 to 4172 200 360
W5 E988-90 0 to 2300 32 to 4172 200 360
<RTDs>
Pt100 IEC60751 -200 to 850 -328 to 1562 10 18 ±0.1% of span or ±0.1°C
±0.05% of span or ±0.05°C
Ni100 DIN43760 -60 to 250 -76 to 482 10 18 ±0.1% of span or ±0.2°C
DC Voltage [mV] -800 to 800 [mV] 2.5 [mV] ±0.1% of span or ±0.01mV ±0.05% of span or ±5μV
Resistance [Ω] 0 to 7000 [Ω] 25 [Ω] ±0.1% of span or ±0.1Ω ±0.05% of span or ±0.05Ω
Note: In T/C type B, the minimum range value can be set from 0°C. However, the accuracy between 0 to 400°C is not specified.

Selection guide for HART 5 and HART 7


Select HART 5 or HART 7 according to Table 2.
Table 2. Selection guide for HART 5 and HART 7
Specified item when ordering HART protocol Selection guide
Note
"HART protocol revision" revision Requirement for HART 7 function Other conditions
Available to switch to HART 7protocol
Specify '5' HART 5 NO *
after delivery by user-configuration.
YES
In this case, be sure to confirm that Available to switch to HART 5 protocol
Specify '7' HART 7
HART configuration tool supports after delivery by user-configuration.
HART 7 by Table 3.
*: Indicate the most typical selection for HART communication. Select this when HART 7 functionality is not required. In case
of selecting HART 7 without conforming to Table 3, communication will not be available.

HART protocol revision and communication


Protocol revision supported by HART configuration tool must be the same or higher than that of the device.
HART 7 communication is supported by FieldMate R2.02 or later.
Table 3. HART protocol revision and communication
Protocol revision supported
by HART configuration tool
HART 5 HART 7
Communication Communication
HART 5
Available Available
Protocol revision of YTA70
Communication Communication
HART 7
Not Available Available

All Rights Reserved. Copyright © 1999, Yokogawa Electric Corporation GS 01C50C03-00EN Apr. 15, 2016-00
<<Contents>> <<Index>> 4
 DIMENSIONS
Unit : mm (approx. inch)  Sensor Connections
Single input (YTA70)
(+) (+)
1 1
4 5
SUPPLY SUPPLY
Ø6 2 (–)
2 (–)
)
- +

(0.24
6
3 3
3

Ø 44 (1.73)
3

(–) (B)
4 4
- + 5 (+)
5
(A)
6 6
Two-wire RTD or ohm
2 1
T/C or DC milivolts
(+) (+)
1 1
SUPPLY SUPPLY
2 (–)
2 (–)
33 (1.30) 20.2 3 3
(B) (B)
(0.80) 4 4
(B) (B)
5 5 (A)
(A)
6 6 (A)

Three-wire RTD or ohm Four-wire RTD or ohm


F02E.ai

< Ordering Information > Model YTA70 will be shipped with the following settings
Specify Model, suffix, and optional specification codes from the factory if not specified upon ordering;
when ordering. If necessary, also specify the followings; Sensor type: Pt100, 3-wire
1. Sensor type. For RTD and ohm input, specify the Range: 0 to 100 °C
number of wire together. Sensor Burnout: High
2. Calibration range and unit. Response time: 1 s
3. Sensor Burnout: High or Low
4. Response time: An integral number from 1 to 60. < Reference >
5. HART protocol: When output signal code is “J”, HART; Trademark of the HART Communication
specify the HART protocol revision “5” or “7”. Foundation.