WO-205269-Power Tong #8052521

The document contains inspection reports for various equipment, including a Sulush Pump and a Power Tong, conducted by PT. Akura Bina Citra for PT. Bohai Drilling Service Indonesia. Both inspections utilized non-destructive testing methods, including Magnetic Particle Inspection and Hydrostatic Pressure Testing, with all tests resulting in 'Passed' status. The reports also outline periodic examination schedules and inspector details, ensuring compliance with relevant industry standards.

Uploaded by

imron rosyadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views9 pages

WO-205269-Power Tong #8052521

The document contains inspection reports for various equipment, including a Sulush Pump and a Power Tong, conducted by PT. Akura Bina Citra for PT. Bohai Drilling Service Indonesia. Both inspections utilized non-destructive testing methods, including Magnetic Particle Inspection and Hydrostatic Pressure Testing, with all tests resulting in 'Passed' status. The reports also outline periodic examination schedules and inspector details, ensuring compliance with relevant industry standards.

Uploaded by

imron rosyadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

NDE INSPECTION Page 1 of 2

Certificate No. : ABC/WO-34184/X/2019 Issue Date : 23-Oct-19


Customer : PT. BESMINDO MATERI SEWATAMA
Owner : PT. BESMINDO MATERI SEWATAMA
Customer Work Order : PO No.: Proceed Qtt-7694-R2 ABC Job No. : SPK-7977
Job Location : RIG APS # 3525 PULAU BUNYU - KALIMANTAN

EQUIPMENT DETAIL
Description : Sulush Pump
Dimension : 3 1/2'' (OD), 501 cm (L)
Serial Number : SL-312-01
MM/YY of Manufacture : N/A

INSPECTION SUMMARY
NON DESTRUCTIVE TEST
Acceptance Criteria : In compliance with ASME B31.3 : 2018
Y N VIS MPI LP ACC REP TYPE OF INDICATION
✘ ✘ ✘
Body -
Critical Area ✘ ✘ ✘ ✘ -
Other ✘ -
Note : Y=YES, N=NO, VIS=VISUAL, MPI=MAGNETIC PARTICLE INSPECTION, LP=LIQUID DYE PENETRANT, ACC=ACCEPTED, REP=REPAIR
MAGNETIC PARTICLE INSPECTION PICTURE
Method : Wet Continous Visible Examination
In accordance with ABC-MT-0206 Rev. 02 & ASTM E709-
Reference Procedure : 15

Acceptance Criteria : In compliance with ASME B31.3 : 2018

Equipment Used : Certified AC Yoke and Infrared Thermometer

Serial Number : S11-ABC-001


Pole Spacing : 75-150 mm
Mag Current : AC
Calibration Block SN : S08-ABC-002
Consumable : Prepared Bath 7HF and White Contrast WCP-2
Manufacturer : Magnaflux
Magnetic Particle : 7 HF Batch No : 18H14K
White Contrast Paint : WCP Batch No : 17H20K
Application : Flowing
Blowing
✘ Spraying
Ilumination : External Day Light
Temperature : 30 ° C
Post Cleaning : N/A MPI COMPLETED

TEST RESULT
Examination Date : 25-Sep-19 Inspection Status : Passed
The unit has passed visual examination satisfactorily and there is no apparent discontinuities were detected on
Connection during Magnetic Particle Inspection. It is fit to its intended use.

PERIODIC EXAMINATION Due date : 25-Mar-20


The test and or examination(s) should be carried out at interval not exceeding 6 (six) months, but more frequent is needed with
the objectives of enviromental condition, result of previous examination, length of service and statutory requirements.

Inspector Name : Hipron Pandi Sitohang


Inspector Certificate : 004/MT-II-ABC/IX/2018 Valid until : 05-Sep-23 ###
Inspector Signature, Reviewed and Approved, Customer Representative

Hipron Pandi Sitohang Andi Setyo Budianto __________________


ASNT-NDT-MT Level II QHSE Manager/ASNT-NDT Level III
FORM 5.7.7-NDT-10 REV. 00 ISSUED DATE 01/06/2014
PT. AKURA BINA CITRA
Jln. POJ Kalimalang, Kp. Pekopen No. 12. Tambun, Bekasi, Indonesia 17510
Telp. : (62-21) 8833 4486, Fax : (62-21) 8833 4508
Website : www.akurabinacitra.com Info : [email protected]
NDE INSPECTION Page 1 of 1

Certificate No. : ABC/WO-205269/VIII/2024 Issue Date : 30-Aug-24


Customer : PT. BOHAI DRILLING SERVICE INDONESIA
Owner : PT. BOHAI DRILLING SERVICE INDONESIA
Customer Work Order : PO No.: Proceed Qtt-0265 ABC Job No. : SPK-0213 JKT
Job Location : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI

EQUIPMENT DETAIL
Description : POWER TONG
Serial Number : 8052521
Size : 2 7/8" - 3 1/2"
MM/YY of Manufacture : N/A

INSPECTION SUMMARY
NON DESTRUCTIVE TEST
Acceptance Criteria : In compliance with API Spec 7K, Sixth Edition & API RP 7L Cat. III, First Edition
Y N VIS MPI LP ACC REP TYPE OF INDICATION
Body ✘ ✘ ✘ ✘ -
Handle ✘ ✘ ✘ ✘ -
Critical Area ✘ ✘ ✘ ✘ -
Shackle ✘ ✘ ✘ ✘ -
Note : Y=YES, N=NO, VIS=VISUAL, MPI=MAGNETIC PARTICLE INSPECTION, LP=LIQUID DYE PENETRANT, ACC=ACCEPTED, REP=REPAIR
MAGNETIC PARTICLE INSPECTION PICTURE
Method : Wet Continous Visible Examination
In compliance with ASTM E709-15 & ABC-MT-0206
Reference Procedure : Rev.04
In compliance with API Spec 7K, Sixth Edition & API RP
Acceptance Criteria : 7L Cat. III, First Edition
Equipment Used : Certified AC Yoke and Infrared Thermometer
Serial Number : S23-ABC-001
Pole Spacing : 75-150 mm
Mag Current : AC
Calibration Block SN : S10-ABC-002
Consumable : Magnaflux Prepared Bath 7HF and Magnaflux White
Contrast WCP-2
Manufacturer : Magnaflux
Magnetic Particle : 7 HF Batch No.: 18K22K
White Contrast Paint : WCP-2 Batch No.: 19D14K
Application : Flowing
Blowing
✘ Spraying
Ilumination : External Day Light
Temperature : 30 ° C
Post Cleaning : N/A MPI COMPLETED

TEST RESULT
Examination Date : 28-Aug-24 Inspection Status : Passed
The unit has passed visual examination satisfactorily and there is no apparent discontinuities were detected on
Connection during Magnetic Particle Inspection. It is fit to its intended use.

PERIODIC EXAMINATION Due date : 26-Feb-25


The test and or examination(s) should be carried out at interval not exceeding 6 (six) months, but more frequent is needed
with the objectives of enviromental condition, result of previous examination, length of service and statutory requirements.

Inspector Name : Hafli Syahriza Putra


Inspector Certificate : 048.R/SDIT/NDT-MT/IX.2022 Valid until : 08-Sep-27
: 048.R/SDIT/NDT-PT/IX.2022 Valid until : 07-Sep-27
0
Inspector Signature, Reviewed and Approved, Customer Representative

Hafli Syahriza Putra Andi Setyo Budianto __________________


ASNT-NDT-MT/PT Level II ASNT-NDT-228051 LEVEL III
FORM 5.7.7-NDT-10 REV. 00 ISSUED DATE 01/06/2014
ULTRASONIC WALL THICKNESS REPORT FOR
POWER TONG S/N : 2 7/8" - 3 1/2"
CERTIFICATE NO. : ABC/WO-205269/VIII/2024 DATE ISSUED : 30-Aug-24
CUSTOMER : PT. BOHAI DRILLING SERVICE INDONESIA SPK : SPK-0213 JKT
OWNER : PT. BOHAI DRILLING SERVICE INDONESIA PAGE : 2 of 2
CUSTOMER WO. : PO No.: Proceed Qtt-0265
JOB LOCATION : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI
DESCRIPTION : POWER TONG
OWNER SERIAL NUMBER : 2 7/8" - 3 1/2" SCOPE OF WORKS
INSPECT. DATE : 27-Oct-20 Thicknes Gauging ✘
DUE DATE : 27-Apr-21 Upset
Welding
Thickness Gauging Equipment Used Tranducers Data Laminasi
Dakota MMX6 ✘Serial Number S08-ABC-011 Serial Number Model Raw Material ✘
Panametrics Model 26DL Serial Number _________________ N/A Dual Other ( )
KT - M 150 Serial Number _________________ Couplant Type
T - Mike Serial Number _________________ Cristal Size Tranducer Angle Grease ✘

USM 35 DAC Serial Number _________________ Dia. 0.250" 0o Oil


Other ( )
Calibration Block Surface Preparation Probe Frequency
Flat Step Block Serial Number _________________ As Welded Grinding < 2 Mhz 5 Mhz ✘

Radius Step Block ✘


Serial Number S07-ABC-010 Ground Flush Wire Brush ✘
3 Mhz 10 Mhz
Other Serial Number _________________ Coated Surface ✘
Sand Blasting 4 Mhz > 10 Mhz
Thickness Gauging Tech : ✘ Pulse Echo Echo to Echo Coating Thickness
Acceptance Criteria : DS1 Volume 3 API RP7G-2 BS EN 12079-1 ASTM E-797 ✘ API Spec 6A

ILUSTRATION

THICKNESS MEASUREMENT

Minimun
MEASURED
DESCRIPTION / GAUGING Customer
NO SIZE THICKNESS
SERIAL NUMBER POINT Requierement
(mm)
(mm)

16.630
PIPA 1 3'' 16.910
CHOKE 16.350
1 MANIFOLD / 8
1009004 20.320

PIPA 2 3.4'' 21.150

20.390

Inspector Name : 0
Inspector Certificate : 0 Valid Until : 30-Dec-99
: ### Valid Until : Err:509
: ### Valid Until : Err:509
Inspector Name : ###
Inspector Certificate : ### Valid Until : Err:509
### Valid Until : Err:509

Inspected by : Reviewed and Approved : Approved by


Inspector Notes / Comments : Customer Representative :
There were no apparent discountinies
had been detected UT Examination.
The equipment is fit for its intended use.

0 Andi Setyo Budianto


QHSE Manager / ASNT NDT
ASNT MT/PT/UT LEVEL II
Level III
FORM 5.7.7-UT-01A REV. 00 ISSUED DATE 01/06/2014
HYDROSTATIC PRESSURE TEST REPORT
CUSTOMER : PT. BOHAI DRILLING SERVICE INDONESIA
OWNER : PT. BOHAI DRILLING SERVICE INDONESIA
CUSTOMER WORK ORDER : PO No.: Proceed Qtt-0265
ISSUE DATE : 30-Aug-24
WORK LOCATION : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI
ABC JOB NO. : SPK-0213 JKT
CERTIFICATE NO. : ABC/WO-205269/VIII/2024
Page 3 of 4
PART'S DESCRIPTION
PART NAME : POWER TONG
SERIAL NUMBER : 2 7/8" - 3 1/2"
BRAND / SIZE : N/A

HYDROSTATIC DATA
MEDIUM : STATIC WATER
TEMPERATURE : AMBIENT
TEST DATE : 28-Oct-20
ACCEPTANCE CRITERIA : In compliance with API Spec 7K, Sixth Edition & API RP 7L Cat. III, First Edition
DUE DATE : 28-Oct-21

TEST PRESSURE HOLDING TIME RESULT


500 PSI 5 MINUTES ACCEPTABLE
5000 PSI 15 MINUTES ACCEPTABLE

Pressure
Pressure graphic
6000
P=5000 PSI
5000

4000
Pressure graphic
3000

2000

1000 P=500 PSI


0
0 10 20

NON DESTRUCTIVE TESTING*


YES NO RESULT
MAGNETIC PARTICLE TESTING ✘ -
DYE PENETRANT TESTING ✘ -
ULTRASONIC WALL THICKNESS TESTING ✘ -
RADIOGRAPHY TESTING ✘ -

COMMENTS :
No leakage or pressure drop were detected during pressure testing.

OPERATED BY CLIENT REPRESENTATIVE WITNESSED BY REVIEWED AND APPROVED BY

( ) ( ) 0 Andi Setyo Budianto


ASNT-NDT-MT/PT Level II QHSE Manager / ASNT NDT Level III
FORM 5.7.7-HT-01A REV. 00 ISSUED DATE 01/06/2014
HYDROSTATIC PRESSURE TEST REPORT
Page 4 of 4
PART NAME POWER TONG
SERIAL NUMBER : 2 7/8" - 3 1/2"
BRAND / SIZE : N/A
CERTIFICATE NO. : ABC/WO-205269/VIII/2024
PICTURE

STEP 1 : Test Pressure 500 psi STEP 2 : Test Pressure 5000 psi
HYDROSTATIC PRESSURE TEST REPORT
CUSTOMER : ABC/WO-205269/VIII/2024
OWNER : PT. BOHAI DRILLING SERVICE INDONESIA
CUSTOMER WORK ORDER : PT. BOHAI DRILLING SERVICE INDONESIA
ISSUE DATE : 30-Aug-24
WORK LOCATION : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI
ABC JOB NO. : SPK-0213 JKT
CERTIFICATE NO. : ABC/WO-205269/VIII/2024
Page 3 of 4
PART'S DESCRIPTION
PART NAME : POWER TONG
BRAND / SIZE : N/A
SERIAL NUMBER : ADA-04-18-14

HYDROSTATIC DATA
MEDIUM : STATIC WATER
TEMPERATURE : AMBIENT
TEST DATE : 28-Dec-19
ACCEPTANCE CRITERIA : API Spec 6A

TEST PRESSURE HOLDING TIME RESULT


2059 PSI 5 MINUTES ACCEPTABLE
5131 PSI 5 MINUTES ACCEPTABLE
7539 PSI 10 MINUTES ACCEPTABLE

Pressure
Pressure graphic
8000 P=7539 PSI
7000
6000
5000 P=5131 PSI
Pressure graphic
4000
3000
2000
P=2059 PSI
1000
0
0 10 20 30

NON DESTRUCTIVE TESTING*


YES NO RESULT
MAGNETIC PARTICLE TESTING ✘ -
DYE PENETRANT TESTING ✘ -
ULTRASONIC WALL THICKNESS TESTING ✘ -
RADIOGRAPHY TESTING ✘ -

COMMENTS :
No leakage or pressure drop were detected during pressure testing.

OPERATED BY CLIENT REPRESENTATIVE WITNESSED BY REVIEWED AND APPROVED BY

( ) ( ) 0 Andi Setyo Budianto


ASNT-NDT-MT/PT Level II QHSE Manager / ASNT NDT Level III
FORM 5.7.7-HT-01A REV. 00 ISSUED DATE 01/06/2014
HYDROSTATIC PRESSURE TEST REPORT
Page 4 of 4
PART NAME : POWER TONG
BRAND / SIZE : N/A
SERIAL NUMBER : ADA-04-18-14
CERTIFICATE NO. : ABC/WO-205269/VIII/2024
PICTURE

STEP 1 : Test Pressure 2059 psi STEP 2 : Test Pressure 5131 psi

STEP 2 : Test Pressure 7539 psi


ULTRASONIC WALL THICKNESS REPORT FOR
POWER TONG
CERTIFICATE NO. : ABC/WO-205269/VIII/2024 DATE ISSUED : 30-Aug-24
CUSTOMER : PT. BOHAI DRILLING SERVICE INDONESIA SPK : SPK-0213 JKT
OWNER : PT. BOHAI DRILLING SERVICE INDONESIA PAGE : 2 of 2
CUSTOMER WO. : PO No.: Proceed Qtt-0265
JOB LOCATION : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI
DESCRIPTION : POWER TONG
OWNER SERIAL NUMBER : 2 7/8" - 3 1/2"
SCOPE OF WORKS

INSPECT. DATE : 27-Oct-20 Thicknes Gauging ✘


Upset
Welding
Thickness Gauging Equipment Used Tranducers Data Laminasi
Dakota MMX6 Serial Number S08-ABC-011
✘ Serial Number Model Raw Material ✘
Panametrics Model 26DL Serial Number _________________ N/A Dual Other ( )
KT - M 150 Serial Number _________________ Couplant Type
T - Mike Serial Number _________________ Cristal Size Tranducer Angle Grease ✘

USM 35 DAC Serial Number _________________ Dia. 0.250" 0o Oil


Other ( )
Calibration Block Surface Preparation Probe Frequency
Flat Step Block Serial Number _________________ As Welded Grinding < 2 Mhz 5 Mhz ✘

Radius Step Block ✘


Serial Number S07-ABC-010 Ground Flush Wire Brush ✘
3 Mhz 10 Mhz
Other Serial Number _________________ Coated Surface Sand Blasting

4 Mhz > 10 Mhz
Thickness Gauging Tech : ✘ Pulse Echo Echo to Echo Coating Thickness
Acceptance Criteria : DS1 Volume 3 API RP7G-2 BS EN 12079-1 ASTM E-797 ✘ ASME B31.3 : 2018

ILUSTRATION 1

4 2
THICKNESS MEASUREMENT
MEASURED
THICKNESS A 3
DESCRIPTION / GAUGING (inch)
NO
SERIAL NUMBER POINT
1 2 3 4

Long Joint 2'' A 0.381 0.365 0.378 0.377


11 (10 Ft) / B 0.386 0.388 0.382 0.375
141217047 C 0.383 0.384 0.378 0.381
Long Joint 2'' A 0.384 0.367 0.371 0.377
12 (10 Ft) / B 0.379 0.365 0.381 0.379
141217158 C 0.368 0.376 0.372 0.378
B
Long Joint 2'' A 0.387 0.367 0.358 0.368
13 (10 Ft) / B 0.363 0.365 0.372 0.375
141217207 C 0.369 0.371 0.353 0.371

Inspector Name I : Hipron Pandi Sitohang


Inspector Certificate : 004/MT-II-ABC/IX/2018 Valid Until : 05-Sep-23
Inspector Name II : Asep Sudrajat
Inspector Certificate : 001/PT-II-ABC/V/2019 Valid Until : 02-May-24
028/UT-II-ABC/XII/2016 Valid Until : 06-Dec-21
IPC Meena Int' : 2019038 Valid Until : 04-Mar-24

Inspected by : Reviewed and Approved : Approved by


Inspector Notes / Comments : Customer Representative :
There were no apparent discountinies
had been detected UT Examination.
The equipment is fit for its intended use.

Asep Sudrajat Andi Setyo Budianto


ASNT PT/UT/MT QHSE Manager / ASNT NDT
LEVEL II Level III
FORM 5.7.7-UT-01A REV. 00 ISSUED DATE 01/06/2014
ULTRASONIC WALL THICKNESS REPORT FOR
POWER TONG
CERTIFICATE NO. : ABC/WO-205269/VIII/2024 DATE ISSUED : 30-Aug-24
CUSTOMER : PT. BOHAI DRILLING SERVICE INDONESIA SPK : SPK-0213 JKT
OWNER : PT. BOHAI DRILLING SERVICE INDONESIA PAGE : 3 of 3
CUSTOMER WO. : PO No.: Proceed Qtt-0265
JOB LOCATION : BDSI #85, GE 77, TANJUNG JABUNG BARAT - JAMBI
DESCRIPTION : POWER TONG
OWNER SERIAL NUMBER : 2 7/8" - 3 1/2"

SCOPE OF WORKS


INSPECT. DATE : 27-Oct-20 Thicknes Gauging
Upset
Welding
Thickness Gauging Equipment Used Tranducers Data Laminasi
Dakota MMX6 Serial Number S08-ABC-011
✘ Serial Number Model Raw Material ✘
Panametrics Model 26DL Serial Number _________________ N/A Dual Other ( )
KT - M 150 Serial Number _________________ Couplant Type
T - Mike Serial Number _________________ Cristal Size Tranducer Angle Grease ✘

USM 35 DAC Serial Number _________________ Dia. 0.250" 0o Oil


Other ( )
Calibration Block Surface Preparation Probe Frequency
Flat Step Block Serial Number _________________ As Welded Grinding < 2 Mhz 5 Mhz ✘

Radius Step Block ✘


Serial Number S07-ABC-010 Ground Flush Wire Brush ✘
3 Mhz 10 Mhz
Other Serial Number _________________ Coated Surface Sand Blasting

4 Mhz > 10 Mhz
Thickness Gauging Tech : ✘ Pulse Echo Echo to Echo Coating Thickness
Acceptance Criteria : DS1 Volume 3 API RP7G-2 BS EN 12079-1 ASTM E-797 ✘ ASME B31.3 : 2018

ILUSTRATION 1

4 2
THICKNESS MEASUREMENT
MEASURED
THICKNESS 3
DESCRIPTION / GAUGING (inch) C
NO
SERIAL NUMBER POINT
1 2 3 4

A 0.373 0.368 0.382 0.384


Long Joint 2''
21 B 0.390 0.384 0.392 0.390
(10 Ft) / 141217173
C 0.393 0.382 0.394 0.400
A 0.373 0.381 0.384 0.378
Long Joint 2''
22 B 0.369 0.398 0.376 0.373
(10 Ft) / 141217084
C 0.378 0.393 0.376 0.375 B
A 0.410 0.390 0.381 0.388
Long Joint 2''
23 B 0.391 0.378 0.380 0.386
(10 Ft) / 141217117
C 0.387 0.375 0.371 0.385
A 0.400 0.376 0.387 0.388
Long Joint 2''
24 B 0.386 0.377 0.387 0.383
(10 Ft) / 141217097
C 0.387 0.370 0.384 0.387
Long Joint 2'' A 0.392 0.387 0.381 0.382
25 (10 Ft) / B 0.382 0.383 0.381 0.380
071911A10361 C 0.374 0.373 0.375 0.377

Long Joint 2'' A 0.393 0.389 0.386 0.385


A
26 (10 Ft) / B 0.384 0.376 0.386 0.380
070811A10210 C 0.372 0.375 0.370 0.377
Long Joint 2'' A 0.378 0.385 0.372 0.364
27 (10 Ft) / B 0.370 0.372 0.374 0.377
071911A10357 C 0.372 0.371 0.370 0.376
Long Joint 2'' A 0.377 0.374 0.402 0.374
28 (10 Ft) / B 0.385 0.381 0.352 0.375
071911A10359 C 0.375 0.382 0.377 0.372
Long Joint 2'' A 0.346 0.359 0.342 0.337 Inspector Name I : Hipron Pandi Sitohang
29 (10 Ft) / B 0.353 0.338 0.354 0.356 Inspector Certificate : 004/MT-II-ABC/IX/2018 Valid Until : 05-Sep-23
071911A10357 C 0.352 0.361 0.356 0.362 Inspector Name II : Asep Sudrajat
A 0.377 0.385 0.398 0.380 Inspector Certificate : 001/PT-II-ABC/V/2019 Valid Until : 02-May-24
Long Joint 2''
30 B 0.381 0.384 0.390 0.373 028/UT-II-ABC/XII/2016 Valid Until : 06-Dec-21
(10 Ft) / 141217144
C 0.385 0.372 0.389 0.373 IPC Meena Int' : 2019038 Valid Until : 04-Mar-24

Inspected by : Reviewed and Approved : Approved by


Inspector Notes / Comments : Customer Representative :
There were no apparent discountinies
had been detected UT Examination.
The equipment is fit for its intended use.

Asep Sudrajat Andi Setyo Budianto


ASNT PT/UT/MT QHSE Manager / ASNT NDT
LEVEL II Level III
FORM 5.7.7-UT-01A REV. 00 ISSUED DATE 01/06/2014