Escalator Drawings

The document outlines specifications for an escalator installation, including dimensions, power supply requirements, and safety features. It details the necessary structural support distances and load capacities, as well as installation guidelines for various components. Additionally, it provides information on rated speeds and transport capacities for different escalator models.

Uploaded by

san2papa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
616 views1 page

Escalator Drawings

The document outlines specifications for an escalator installation, including dimensions, power supply requirements, and safety features. It details the necessary structural support distances and load capacities, as well as installation guidelines for various components. Additionally, it provides information on rated speeds and transport capacities for different escalator models.

Uploaded by

san2papa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Distance between supports L=1.

428*H+4755+690(upper part)=8800±10 Ø100



≥6640+1.428*S C
2514+690 1140
safety fence(by others) 628+690 B
838
A Specification:
600

≥300

900
Ⅱ R1
1.Main power: 380/220V 3-phase 5-line.Customer provide
grounding terminal with resistance no bigger than 4Ω.
the fluctuation of voltage can not over than±7%.
Ø100 Ⅰ

S
2.Pit bottom should be smooth and bright, water-proof.No

≥2300
need pit if escalator was installed above second floor.
Climbing prevention device power supply
by others 400
by others 3.The pressure here is for one unit,when two in parallel,

H=2350±1
91
the girder bear pressure more than twice of it.

8
min 500mm otherwise deflector

230
2241 4.If there is middle support,it should be firmly welded
by others
628 with the truss, distance between two adjacent support
should no more than 15m.

5."S" in drawing stands for floor plate thickness.


1000

35°
900

R2
30 30
min1100


1009

Number Rated speed of Theoretical transport Customer service


escalator capacity selection
min4100 D
clear floor access min1200 1. 0.4 m/s 2880 p/h
area
2. 0.45 m/s 3240 p/h

170 3. 0.5 m/s 3600 p/h

CODE α=35° H=2350


min1200

2×1200
STEP WIDTH A=600mm

1200
RISE H=2350mm

170 SPAN L=8800mm


≥500

When net distance less than 500mm, min2000


POWER SUPPLY 380V 60HZ
provide safety boards(by others) min2500 LIGHTING SUPPLY 220V 60HZ

MOTOR POWER 5.5 KW


DETAIL Ⅱ
REACTIONS(single) R1=42KN
embellished ground 170 L
REACTIONS(single) R2=37KN
125

PROJECT NAME FJFDZLY25060503


DETAIL Ⅰ CUSTOMER SIGNATURE
700

光滑地方

80KN
CUSTOMER SEAL

power supply DRAWING DATE


edge of truss
CHECKED EDITION 2021A
steel plate 20x150xCx2 edge of support
by others 40