BAOPUSA3
BAOPUSA3
Operating Manual
Hardware Description
Versions
Example
OPUSA3EL1CANB000
OPUSA3 model
E E=ECO; S= Standard
L L= Landscape; P= Portrait; N= Neutral
1 1. Generation
CAN CAN=Projektor; CDS=CODESYS©; ISO=ISO-UT
B B=Basic F= Full
000 customer specific identification
Seite II von 32
Table of contents
Table of contents
5 Technical Documentation................................................................................25
Seite IV von 32
Preliminary Notes
1 Preliminary Notes
This document is valid for the following OPUS A3 version:
• OPUSA3E “ECO”
• OPUSA3S “Standard”
This document is directed to the qualified personnel and contains all the important
information to the correct use of the OPUS A3.
Please read this document before the first use and keep it during the operation.
In order to provide a better overview, this operating manual cannot present all
details for handling the OPUS A3 in all conceivable application cases. Neither can
all conceivable methods of setting up the device, operating the device, and servicing
the device be discussed in this manual. In case more information or support is
required please contact manufacturer technical support department.
This operating manual contains instructions that must be complied with for your
personal safety and in order to avoid damage to property.
Hazard!
Caution!
Note
Seite 1 von 32
Safety instructions, guarantee and liability
2 Safety instructions, guarantee and liability
2.1 Common
Read this operating manual before commissioning the OPUS A3. Keep this
operating manual where it is accessible to all users at anytime. Every person who is
assigned to commission or operate the OPUS A3 must have read and understood
the operating manual and the safety instructions in particular!
This operating manual contains instructions that must be complied with for your
personal safety and in order to avoid damage to property. Failure to follow these
safety instructions could result in fire, electric shock, or other injury or damage to
OPUS A3 or other property.
This operating manual is intended for technically qualified personnel, who have the
appropriate skills in the area of measurement, control, and regulating technology.
Precise knowledge of all safety instructions and warnings contained in this operating
manual, as well as problem-free technical implementation of these instructions and
warnings are the prerequisites for hazard-free installation, commissioning, safe
operation, and maintenance, of the operator panel. Consequently it is strictly
required that all measures be performed by qualified personnel.
• are familiar with CANbus systems, related protocols and network designs that
fulfill all legal requirements of the intended application, so that they are able
to program the OPUS operator panel accordingly
• have gained knowledge of the programming related concepts by education or
trainings. Using the Projektor Tool a Projektor Tool training by Wachendorff
needs to be attended. Using CODESYS© a CODESYS© training needs to be
attended, either held by Wachendorff or 3S.
• are familiar with the safety concepts of automation technology, either as
project design personnel
• or operating personnel who have been instructed in how to handle the
automation technology, and who are familiar with the section of this manual
which deals with operation.
• or who, as commissioning, and service personnel have been trained to repair
this type of automation technology, or who are authorized to commission,
ground, and label electrical circuits and devices, or systems, in accordance
with technical safety standards.
All persons who are involved in project planning, installation and operating the
OPUS A3 must be familiar with automation technology safety concepts, and they
must be qualified in accordance with the guidelines listed above.
Seite 2 von 32
Safety instructions, guarantee and liability
Serious bodily injury and property damage can occur in the event of unqualified
interventions in the device, or the system, or failure to heed the warning instructions
specified in this operating manual.
OPUS A3 is designed for 12 V and for 24 Volt battery systems. The operating
voltage range is 9-36 VDC, overvoltage resistance 48V for 2 minutes, inverse-
polarity protection up to -48 VDC.
The OPUS A3 has been developed, manufactured, and tested in compliance with
applicable standards. When the handling guidelines and safety-related instructions
described here are complied with for project design, mounting, intended use, and
maintenance, normally the product poses no hazards relative to property damage or
to personal health. Nevertheless the device can cause residual hazards if it is used
or operated improperly by personnel who have not been trained.
In case of malfunctions or lacks please get in contact with the manufacturer. Any
interventions in the device are able to cause serious interferences of the security for
people and machines. They are not allowed and lead to disclaimer of liability and
guarantee exclusion.
Seite 3 von 32
Safety instructions, guarantee and liability
Moreover we expressly declare that all obligations on the part of Wachendorff are
exclusively derived from the respective purchase contract, in which the guarantee is
conclusively stipulated.
Dangerous high-voltage
Never attempt to repair or modify OPUS A3 yourself.
Disassembling OPUS A3 may cause damage that is not covered
under the warranty and cause hazardous conditions by the
high-voltage components inside of the unit.
OPUS A3 does not contain any user-serviceable parts. Service
should only be provided by a Wachendorff Elektronik GmbH &
Co KG.
Seite 4 von 32
Safety instructions, guarantee and liability
Unintentional operation
Operating states can be called due to unintentional operation of
the OPUS A3 that are not appropriate for the situation.
OPUS A3 devices should be installed in such a manner that the
possibility of unintentional operation is adequately excluded.
Seite 5 von 32
Intended Use
3 Intended Use
The operator panel OPUS A3 is a programmable graphical display used to operate
and monitor vehicles and working machines.
The communication with other system components, as for example decentralised I/O
module, occurs over the CAN interfaces with the supported protocols: CANopen,
J1939 and CANfreestyle (layer 2).
For service purposes additional interfaces like Ethernet, RS232, USB and
analog/digital inputs/outputs (optional) are available. Together with Embedded Linux
operating system they form a universal platform for the communication with other
CAN devices, networks or PCs.
Seite 6 von 32
Intended Use
3.2 Device Description
Multicolor LED
Display
Function Keys
Display
Seite 7 von 32
Intended Use
Display
Softkeys F1 – F8
3 Status LEDs
Light sensor (optional)
Function Keys
Multicolor LED
USB Slot behind Encoder
flap (optional)
For display, light sensor and multicolor LED please see the description for the OPUS
A3 ECO.
Softkeys F1 to F8:
All softkeys can be assigned to the function defined in the customer specific
application. Please see the Operational Manual of the application tools for more
information.
Using Projektor Tool the functions for these keys are fixed:
HOME is used to change the display page to the start page of the
application
Seite 8 von 32
Intended Use
The Encoder:
Encoder is used for the navigation between the objects in customer specific
application. It is possible to select graphical objects on the screen and change there
value rotating the encoder. An entry function can be generated directly on rotating or
by pressing the encoder.
LEDs:
There are 3 different status LEDs available on the unit:
yellow light during the data transfer over the USB interface
Multicolor LED (option) is embedded in keypad and can be free programmable. This
LED is able to show PWM-controlled RGB colours, 16 bit each.
Light Sensor:
The light sensor offers the possibility for an automatic adaption of display-backlight
and key-backlight to the ambient light intensity.
Main connector:
There are following interfaces available of the main connector:
• Power supply and ignition input
• 2 x CAN-Interfaces according to ISO/DIS 11898
• RS232-Interface
• USB
• 4 analogue/digital inputs (optional)
• 3 digital outputs (optional)
Seite 9 von 32
Intended Use
Video (optional):
This interface is used for the analog Video-Input included protected camera power
supply.
Ethernet (optional):
There is an Ethernet interface (10/100 Mbit/s Base) available on the unit. This
interface may only used for the data transfer.
Power-on/off Behavior:
The OPUS A3 does not have a separate on/off key. As soon as the device is
supplied with the necessary voltage via terminal 30 (battery plus), terminal 31
(battery GND) and terminal 15 (ignition), it will start to boot. In order to decrease
boot time the device supports power modes with which you can put the device in a
sleep mode before it powers down.
When ignition voltage is removed, the device will switch to low-power-mode (see
C/C++ Developer Guide). After a time frame that can be configured (default time is
60 sec) the device will move one more step down to sleep-mode. After another 60
seconds (default time) the unit will fully switch off. As soon as terminal 15 is switched
on again the unit will go back to on-mode in full operation.
Seite 10 von 32
Intended Use
• RS232 interface for serial console and Full-Speed USB on main connector
• High speed USB on the front (optional)
The OPUS A3 is particularly characterized by its robust construction, and it has been
developed especially for harsh use conditions in mobile work machines.
There are three possible ways to program the OPUS A3 and make it an integrated
part of its application.
1. Projektor-Tool:
This powerful development environment provided by Wachendorff Elektronik GmbH
& Co KG enables the quick and effective creation of an application for the OPUS A3
operator terminal. Use the Projektor to conveniently design the user interface on the
computer, which can be easily displayed on the device. In addition this tool includes
features to work with CANopen®, J1939 and CANfreestyle protocols for CAN
communication. Fur further information please refers to the Operator Manual
Projektor Tool III.
2. CODESYS© 3.x:
CODESYS© is a programming tool and system developed by the German company
3S. It supports different means of programming such as FUB or Structured Text. It
can be used to program the OPUS A3 and CODESYS© compatible ECUs.
CODESYS© includes the functionality to configure the CANopen® protocol for
communication over CAN bus. For further information please refer to the
BAOPUSA3CDS.
3. C-Programming:
OPUS A3 with its embedded Linux as operational system can be fully programmed
using C or C++ as programming language. For further information and function-call
list please refer to the C/C++ Developer Guide.
4. ISO-UT:
OPUS A3 can be used as a ISO-UT slave. According to the ISO-11783 standard and
DLG conformity.
6. Universal Downloader:
To download software from the PC to the terminal the Universal Downloader 4 is
provided. It supports a download via USB stick and Ethernet. The Universal
Downloader 4 also stores the software, installs it and restarts the application on the
terminal. It is part of the Wachendorff Toolchain and documented in the Operator
Manual Projektor Tool III.
Seite 11 von 32
Intended Use
Please notice the following recommendation and prerequisites for the computer used
to the application design and /or programming:
- Using Projektor Tool and CODESYS© for the development it is recommended
to use the PC with Windows XP operational system (for CODESYS© it may
by younger), at least 2 GB free hard disk capacity and 2 GB RAM. Serial port
is recommended.
- Programming with C/C++ Linux operational system is prerequisite.
To be support programming the graphical user interface for the OPUS A3 terminal
the different development kits referred to the using tools are provided.
CODESYS© 3.x
Order number: OPEP00A3CDS
Seite 12 von 32
Intended Use
Basic CODESYS© training at a 1
Wachendorff facility
12 month technical support 1
Seite 13 von 32
Getting Started
4 Getting Started
4.1 Check the delivered parts
Please check whether all parts described in the scope of delivery have been
delivered correctly. For question or reclamation please contact the support team of
Wachendorff Elektronik GmbH & Co KG ([email protected]).
4.2 Mounting
The back side of the unit is ready prepared for both in dash and standalone
mounting.
For mounting please follow the instruction provided in the following dimension
drawing.
Seite 14 von 32
Getting Started
3
4
Parts List
Pos. Description Order number Supplier
1 OPUS A3 Standard OPUSA3SXXXXX Wachendorff Elektronik
2 Dashboard - Customer
3 Spacer or washer - Customer
4 Mounting Cover OPUSA3ZBEB001 Wachendorff Elektronik
5 M5 Screw* (DIN EN ISO 4762) - Customer
Seite 15 von 32
Getting Started
Attention!
Using too long screws can damage the unit!
Accepted mounting torque with mounting cover is 2,5 ± 0,2 Nm.
Please secure the screws with the thread locker medium
strength (e.g. Loctite 243).
Seite 16 von 32
Getting Started
4.2.3 Mounting Cover for OPUS A3 STANDARD
Seite 17 von 32
Getting Started
3
4
Parts List
Pos. Description Order number Supplier
1 OPUS A3 Eco OPUSA3EXXXXX Wachendorff Elektronik
2 Dashboard - Customer
3 Spacer or washer - Customer
4 Mounting Cover OPUSA3ZBEB002 Wachendorff Elektronik
5 M5 Screw* (DIN EN ISO 4762) - Customer
Seite 18 von 32
Getting Started
Attention!
Using too long screws can damage the unit!
Accepted mounting torque with mounting cover is 2,5 ± 0,2 Nm.
Please secure the screws with the thread locker medium
strength (e.g. Loctite 243)
Seite 19 von 32
Getting Started
4.2.6 Mounting Cover
Seite 20 von 32
Getting Started
4.3 Electrical installation OPUS A3
Below you find the pin out diagram of the OPUS A3. The connectors are drawn as
seen from the back side of the unit.
Please be aware that the existing pins and connectors depend on the hardware
option you ordered.
Please note that the OPUS A3 only represents one part of the entire CAN network.
Set-up and dimensioning of the network must be executed by specialized personnel,
and the information in this regard cannot be a component of this operating manual.
Seite 21 von 32
Getting Started
Main connector pinout (in full option)
• Power supply lines should only be laid as pairs, as close together as possible.
• Sensitive signal lines should be shielded to achieve highest possible
damping, and under this shielding they should be still be laid out twisted.
• Metal plug connections should be used for shielded lines.
• Cable bundles should be distributed in accordance with their purpose (e.g.
HF, LG, and power supply); the groups thus formed should not be routed
parallel to the extent possible, and they should be routed with clearance.
The OPUS A3 relies on a connection to an ECU that controls the functions and
features of the target vehicle/machine.
Seite 22 von 32
Getting Started
Please keep all the connectors separated. All connection should be done on the
shortest distance to the unit.
The unit may be used with the 12 V and for 24 Volt battery systems, operating
voltage range of 8-36 VDC. The overvoltage resistance is about 48V for 2 minutes.
Inverse-polarity protection is up to -48 V DC.
Car ground (pin no. 4 on main connector) has to be connected to the chassis by a
conductor as short as possible. Even if there is no conductive chassis available (eg.
in E-vehicles) the pin has to be connected to the negative pole of the battery.
Otherwise there will be no protection against over voltage, shot cut or ESD.
Plug the main connector into the OPUS A3. Then connect the pins 15 and 30 for the
plus voltage, as well as pins for GND and CarGND for the ground. Switch on the
Power supply.
On start the boot-logo image will be displayed on the screen. This may be
exchanged with the customer specific image (please refer to C/C++ Developer
Guide for more information).
Seite 23 von 32
Getting Started
The boot up takes about 3 minutes and will call the application according to the start
scripts on the unit (start scripts for Projektor Tool and CODESYS© application
already installed by delivery).
The application display the information to the version of the application software
required. CODESYS© application also contains a simple function test. Each new
downloaded application will replace the old one automatically.
Cleaning agents which have an abrasive or dissolving effect on the coated glass
pane, the foil of the touch screen or the plastic of the encoder or the housing should
not be used to clean OPUS A3 operator panels. Only use soft clothes with a little
soap and water or mild dish washing liquid.
The OPUS A3 does not have any parts that require service by the user.
Seite 24 von 32
Technical Documentation
5 Technical Documentation
The OPUS A3 is currently available in two variants:
OPUS A3 STANDARD:
OPUS A3 ECO:
Seite 25 von 32
Technical Documentation
5.1 Dimension Drawings - OPUS A3 STANDARD
Seite 26 von 32
Technical Documentation
5.2 Dimension Drawings - OPUS A3 ECO
Seite 27 von 32
Technical Documentation
5.3 Specification
Seite 28 von 32
Technical Documentation
5.4.1 CE-Compliance
IP 6k5 and 6k7 according to ISO 20653: Road Vehicles – Degrees of protection (IP-
Code) – Protection of electrical equipment against foreign objects, water and access
According to ISO 16750-3: Road Vehicles – Environmental conditions and testing for
electrical and electronic equipment – Mechanical loads, Code L
Seite 29 von 32
Technical Documentation
Seite 30 von 32
Technical Documentation
Seite 31 von 32
Technical Documentation
Seite 32 von 32