031 Probe Systems Triggered R2025-1 WENZEL
031 Probe Systems Triggered R2025-1 WENZEL
Probe Systems
Triggered
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
All rights, including those of reprinting, replication of parts of this training document and its translation are
reserved by the publisher.
No part of this training document may be reproduced in any form or copied with the aid of electronic repli-
cation systems without the written approval of the publisher.
Contents
Probe systems 3
Learning goals 3
Configuration 7
Machine settings 10
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
Calibrate probe system automatically 14
Select calibrate 14
List view 16
Clear probe 17
Probe systems
Probe systems are used in order to probe points on the work piece. WM | Quartis uses these points to cre-
ate elements such as lines, planes, circles, cylinders, and so forth.
• Tactile (touching) probe system triggered, meaning point for point measurement
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
• Calibrate triggered probe systems automatically
031_Probe_Systems_Triggered_R2025-1.docx
In the case of special, star and disc stylus, it is essential to set them up
graphically. Certain set-up data is required during calibration.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
Pay particular attention to the permissible weight and length dimen-
sions of the sensor manufacturer. This can influence the accuracy of
the calibration.
031_Probe_Systems_Triggered_R2025-1.docx
Stylus Changing If a Stylus changing system is configured for automatic changing of the
probe systems, it is important to first assign the correct changer and
System
rack slot to the new probe system.
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
With the Function the actual configuration is deleted.
Closes the dialogue and the changer configuration remains in the back-
ground
Setup probe system It is beneficial to set up (configure graphically) the used probe system
for the display in offline mode (not connected to machine). This allows
selecting adequate probe systems easier, checking probe positions and
accomplishing collision considerations.
Template and user catalog The most common Renishaw components are included in a template
catalog. The user can assemble his own catalog, containing only the
components available on his machine. With this user catalog, the setup
of the probe system can be easily made.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
catalog (upper half).
The length information of the stylus refers to the center of the probing
sphere.
on
Adopt the configuration for the current probe system while the configu-
ration dialog remains opened.
on
Adopts the configuration for the current probe system and closes the
dialog at the same time.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
on
Unsuitable components
on
You can enter any name for the assembly when saving.
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
More information about the function Set up probe system is available
in the WM | Quartis help.
031_Probe_Systems_Triggered_R2025-1.docx
The functions related to the probe systems are found in the ribbon
Machine.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
Reference sphere settings Check the reference sphere settings first.
on
on
031_Probe_Systems_Triggered_R2025-1.docx
on
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
on
The same measuring speed and acceleration should be set for calibra-
tion and for measuring on the work piece. Overall, the same setting
031_Probe_Systems_Triggered_R2025-1.docx
on
Select stylus
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
on
Calibrate probe system With the semi-automatic calibration, only the point on the pole of the
semi-automatically reference sphere has to be probed, all other points are probed by the
machine automatic.
on
Select stylus
Start the calibration via the command button Start. In this case only a point
on the pole of the sphere has to be probed. Probe in stylus direction towa-
rds the center of the sphere.
on
The machine then autonomously probes the reference and measuring
points that are required for probe system calibration.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
on
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
Number and name of the probe system can be adjusted.
031_Probe_Systems_Triggered_R2025-1.docx
Calibrate probe system If an articulating probing system, e.g. PH10M, is available, multiple
probe positions can be calibrated automatically.
automatically
Calibrate articulating probe sys- If needed, the articulating probe system has to be calibrated first using
tem this function.
The reference probe system usually is the probe system that is calibra-
ted with the angle positions A0 B0. It is recommended to graphically set
up the reference probe system before calibrating other probe systems
(see chapter Set up probe system). The graphical configuration is then
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
automatically adopted with the automatic calibration for all other
probe positions.
Select calibrate
on
031_Probe_Systems_Triggered_R2025-1.docx
Just as with manual calibration, you should check the machine settings.
on
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
Define those positions of the probe system that you want to calibrate
by selecting the corresponding checkboxes of the A and B angles.
031_Probe_Systems_Triggered_R2025-1.docx
on
After exiting the matrix with OK, the probe positions to be calibrated are
on displayed in the calibration list.
on
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
031_Probe_Systems_Triggered_R2025-1.docx
Position the probe near to the reference sphere in order to prevent col-
lisions with parts possibly mounted on the machine during the automa-
tic travel to the reference sphere.
Click on Calibrate probe system. The probe systems are calibrated and
saved directly into the system database.
Information about the dialog
Calibrate probe system (matrix)
After the calibration, re-open the ribbon Calibrate probe system
on
and the matrix in order to calibrate automatically.
on
Probe systems calibrated outside the defined range,
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
not yet calibrated probe systems,
The selected probe systems are marked in the matrix and thus can be
adopted into the calibration list.
on
The above described procedure for probe system calibration may be re-
corded into a program. More related information you find in the
WM | Quartis help Adjust probe system settings.
Exclusive use according to the user agreement permitted for WENZEL Group GmbH & Co. KG and its customers.
The function allows you to select measuring programs and to au-
tomatically take over probe systems included into the calibration list.
More related information you find in the WM | Quartis help.
031_Probe_Systems_Triggered_R2025-1.docx