PN. DESC.
1 Decompression
chamber
2 Condensate inlet
3 Filter bin
4 Sampling port
5 Water outlet
6 Overflow
7 Compare bottles
PN. DESC.
1 Decompression chamber
2 Condensate inlet
3 Filter bin
4 Secondary filter bin
5 Sampling port
6 Oil storage drums
Front view of the device
7 Compare bottles
8 Primary filter bin
9 Level warning rod
10 Condensate inlet
11 Overflow
12 Filter bin access openings
13 Pre-separation bin access port
※ 12, 13,
Back view of device for the process port, installation does not need to
consider.
※It can also be used to open the hole and
connect the ball valve, which is used to discharge
the residual liquid in the equipment when the
equipment is overhauled, displaced and scrapped.
The activated carbon filter element needs to be soaked in clean water for 24h to achieve
the best filtration performance, and the water level is referred to Figure 1.
Don't worry that water can not enter the condensate processor, although the drain outlet is
low, the inlet of the condensate processor is high, but no matter what kind of drainage
method, the drainage is pressured, and the water will definitely enter the condensate
processor.
The equipment should be installed on a flat ground.
The treated condensate can reach the national three-level discharge standard and needs to
be taken over to the municipal sewage pipe network for discharge.
1. The water level of the
secondary filter
chamber is added to the
diffuse activated carbon
filter element;
2. Water level of pre-separation bin,
Add to the mouth of the overflow
pipe .
1. Single set of air
compressor equipment,
one-to-one installation;
2. Multiple sets of air
compressor equipment,
multi-to-one
installation;
After 1-2 weeks of use, adjust according to the Under normal circumstances, what
thickness of the oil layer should be received in the oil drum is oil
Adjust the block to a suitable height to drain the oil;
It is subject to 3-5mm higher than the oil surface
The oil layer in the pre-separation bin is very The oil storage drum collects a
thick, but the storage drum can not collect oil, large amount of condensate, and
the oil pipe adjustment block needs to lower the tubing regulating block needs
the height to be raised upwards
1. Use the comparison bottle regularly for 3-4 weeks for water quality inspection, if the
turbidity is higher than the comparison bottle, you need to change the filter element;
2. The red warning floating rod of the filter compartment floats, and the filter element
needs to be replaced;
3. The filter element is blocked and the overflow port begins to produce water, so the
filter element needs to be replaced;
4. After using at most 6000h, the filter element must be replaced;
Note: Condensate processors with a throughput of 4 and 8 m³/min replace the filter
element in 4000 hours.
quantity quantity quantity quantity quantity quantity
Name Contains Air compressor Air compressor Air compressor Air compressor Air compressor Air compressor
parts flow 4m ³/min flow 8m ³/min flow 15m³/min flow 30m³/min flow 45m³/min flow 70m³/min
Pressure 1 1 1 1 1 1
Filter reducin
eleme g filter
nt set element
Oil 1 1 1 1 1 1
suction
filter
element
Purifyin 1 2 2 3 2 3
g filter
element
Part number 61220000 61220100 61220200 61220300 61220400 61220500
1. The new activated carbon filter element also needs 24h water
immersion and activation;
2.
High pressure air compressor drainage, may be emulsified;
The quality of the oil is not good, and the drainage of the air compressor may be
emulsified;
High air humidity, long-term high temperature operation of the air
compressor, after the cooling of the post-cooling, when the exhaust
temperature < the exhaust pressure dew point, the air compressor
drainage will be emulsified;
Electronic timing drainage drainage, may emulsify;