1706D E93tag1
1706D E93tag1
1 of 5
Publication No. TPD2258 Issue 2, April 2020
Copyright © 2020 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
General installation
60 Hz @ 1800 rpm
Designation Units Baseload Standby
Prime power
power power
Rating definition
Baseload power
Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.
Prime power
Unlimited hours usage with an average load factor of 70% of the published prime power over each 24 hour period. A 10% overload is
available for 1 hour in every 12 hours operation.
Standby power
Limited to 500 hours annual usage with an average load factor of 70% of the published standby power rating over each
24 hour period
Note: Not to be used for combined heat and power (CHP) purposes (indicative figures only). If necessary, consult Perkins Engines Company
Energy balance
60 Hz @ 1800 rpm
Designation Units Baseload Standby
Prime power
power power
2 of 5
Publication No. TPD2258 Issue 2, April 2020
Copyright © 2020 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Cooling system Fuel system
Total coolant capacity System specification
ElectropaK (with radiator) .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . 35.8 litres Type of injection .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. . Electronic
ElectropaK (without radiator) .. .. ... .. ... .. ... .. ... .. ... .. ... .. .. 20.3 litres Fuel injection pump.. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. ..Common rail
Maximum top tank temperature .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... 107°C Fuel injector .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . Electronic
Maximum static pressure head on pump.. .. ... .. ... .. ... .. ... .. ..170 kPa Nozzle opening pressure .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 20.2 MPa
Coolant temperature rise across engine.. . . . .. . . . .. . . . .. . . . .. . . . .. . .N/A°C Filtration media size .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 4 μm
Maximum permissible external system resistance .. .. ... .. ... .. ... 35 kPa Fuel lift pump type.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. . N/A
Thermostat operation range (closed to fully open) .. .. ... .. ... .. .87-98°C Fuel flowrate.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . 480 l/h
Pressure .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .800 kPa
Recommended coolant Maximum suction head .. . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . . 1 – 2 m
Perkins Extended Life Coolant, 50% antifreeze/50% water. Maximum static pressure head.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . 1.5 – 2.5 m
For details of recommended coolant specifications, please refer to the Maximum fuel temperature at lift pump inlet.. .. .. . .. .. . .. .. . .. .. . .. .. 80°C
Operation and Maintenance Manual (OMM) for this engine model. Governor type .. . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . Electronic
Radiator Speed control conformity .. .. .. . .. .. . .. .. . .. .. . .. .. . ISO 8528-5 Class G3
Radiator face area .. . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .0.62 m² Fuel specification
Core material .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... Aluminium BS 2869 1998 CLASS A2 or BSEN590.
Number of rows.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ..4 Note: For further information on fuel specifications and restrictions,
Fins per inch.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . 10 refer to the OMM fuels section for this engine model.
Width of matrix .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. 1071 mm
Height of matrix.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 1318 mm Fuel consumption data
Pressure cap setting .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 110 kPa
60 Hz @ 1800 rpm
Fan Prime power 267.30
Fan type.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . . Mechanical, fixed
Load condition g/kWh
Configuration .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .. Pusher
Diameter (tip to tip).. . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . 813 mm Standby (110% Prime) 213
Number of blades.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... ..9 Prime 215
Material.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . Plastic
75% Prime 224
Drive ratio .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 1:1
50% Prime 246
Duct allowance 25% Prime 259
Engine speed rpm
Description Units Note: For conversion to l/h use the following formula with the correct
60 Hz @ 1800 rpm fuel density: (SFC [kg/kWh] ÷ Fuel density [kg/l]) × Power [kW] = SFC [l/h]
Ambient clearance °C 72
Duct allowance (1) Pa 125
Cooling fan airflow m3/min 482
3 of 5
Publication No. TPD2258 Issue 2, April 2020
Copyright © 2020 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Lubrication system Electrical system
Total system capacity Alternator output voltage.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... ..24 volts
(Maximum sump capacity (maximum dipstick mark).. .. ... .. ... . 30 litres Alternator output current .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... 45 amps
Minimum sump capacity (minimum dipstick mark) .. .. ... .. ... .. . 26 litres Starter motor input voltage.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. 24 volts
Maximum oil temperature (continuous operation).. . . . .. . . . .. . . . .. . . 110°C Starter motor power draw.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 8 kW
Maximum oil temperature (intermittent operation).. .. ... .. ... .. ... . 115°C Number of teeth on flywheel.. . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . 113
Number of teeth on starter pinion .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 11
Lubricating oil
Relief valve opening pressure.. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 662 kPa Engine stop method .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. .. Electronic
Minimum oil pressure.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . 38 kPa
Oil pressure at maximum no-load speed.. . . . .. . . . .. . . . .. . . . .. . . . ..350 kPa
Oil flow at rated speed.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 130 l/min
Engine mounting
Maximum static bending moment at rear face of block.. . . . .. . . . 1920 Nm
Maximum engine operating angles Maximum static bending moment for
Front up, front down .. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... . 35° exhaust outlet (for muffler design).. .. ... .. ... .. ... .. ... .. ... .. ... .. 0.4 Nm
Right side up, right side down .. .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . 20°
Note: single or multigrade oil conforming to API-CH-4
A
or ACEA E5 must be used.
Viscosity grade
15W-40
10W-40
10W-30
5W-40
5W-30
0W-40
0W-30
Induction system
Maximum air intake restriction
Clean filter.. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 3.7 kPa
Dirty filter.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ..6.2 kPa
Air filter type .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. Dry
Number of air filters.. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . ..1
Exhaust system
Number of exhaust outlets.. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . . .. . . 1
Exhaust outlet diameter .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. 127 mm
Minimum back pressure.. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . .. .. . ..2 kPa
Maximum back pressure.. .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. 10 kPa
4 of 5
Publication No. TPD2258 Issue 2, April 2020
Copyright © 2020 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com
Noise data
Noise level
The figures for total noise levels are typical for an ElectropaK running at prime power rating in a semi-reverberant
environment and measured at a distance of one metre
Octave analysis
The following figure shows a third octave band analysis at the position of the maximum noise level:
120.0
100.0
80.0
SPL (dB(A))
60.0
40.0
20.0
0.0
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
6300
8000
10000
Frequency (Hz)
1800rpm / 60 Hz
Notes
• If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes.
• Sound pressure reference level: 20 μPa.
• One third octave analysis performed at the position where the highest noise levels were measured.
5 of 5
Publication No. TPD2258 Issue 2, April 2020
Copyright © 2020 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com