0% found this document useful (0 votes)
25 views2 pages

Vegator 132

The VEGATOR 132 is a double-channel controller designed for point level detection using conductive sensors, suitable for applications like level detection and pump control. It features two independent level detections, integrated fault monitoring, and operates with a wide range of voltage supplies. The device is compact, easy to mount, and has worldwide approvals for various applications.

Uploaded by

james.tong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views2 pages

Vegator 132

The VEGATOR 132 is a double-channel controller designed for point level detection using conductive sensors, suitable for applications like level detection and pump control. It features two independent level detections, integrated fault monitoring, and operates with a wide range of voltage supplies. The device is compact, easy to mount, and has worldwide approvals for various applications.

Uploaded by

james.tong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Specification sheet

VEGATOR 132
Double-channel controller for point level detection with conductive sensors
Technical data

General data
Series Module unit for mounting on carrier rails
35 x 7.5 acc. to EN 50022/60715
Connection terminals
ƲƲ Wire cross-section 0.25 mm² (AWG 23) … 2.5 mm² (AWG 12)
Voltage supply
Operating voltage
ƲƲ Nominal voltage AC 24 … 230 V (-15 %, +10 %), 50/60 Hz
ƲƲ Nominal voltage DC 24 … 65 V (-15 %, +10 %)
Max. power consumption 2 W (8 VA)
Sensor input
Quantity 2 x for connection of a conductive elec-
trode
Input type Active (sensor power supply by VEGATOR
132)
Measured value transmis- Alternating voltage
sion
Response resistor 500 Ω … 200 kΩ, adjustable
Application area Terminal voltage (idle 10 Vss rectangular voltage 75 Hz
The VEGATOR 132 is a double-channel controller for conductive state)
probes type EL. Applications are level detections and pump controls. In Permissible line capaci- 200 nF
conjunction with multiple rod or cable probes, several VEGATOR 132 tance
can be combined with a probe. Relay output
Quantity 2 x operating relay
Your benefit Contact Floating spdt
Switching voltage min. 10 mV DC, max. 253 V AC/50 V DC
• Compact controller with alarm function for limit level
Switching current min. 10 µA DC, max. 3 A AC, 1 A DC
• Two independent level detections or one min./max. control (two-point
Breaking capacity min. 50 mW, max. 500 VA, max. 54 W DC
control)
Switch-on/Switch-off delay
• Integrated fault monitoring with LED display detects line break
ƲƲ Basic delay 250 ms, ± 20 %
• Simple mounting through carrier rail as well as detachable, coded
terminals ƲƲ Adjustable delay 2/6/8 s, ± 20 %
Ambient conditions
Ambient temperature at -20 … +60 °C (-4 … +140 °F)
Function
the installation site of the
The VEGATOR 132 is a double channel limit level alarm and is mainly instrument
used for level detection in conjunction with conductive probes. All sen- Electrical protective measures
sors of series EL can be connected. The signal circuit is permanently Protection rating IP20
monitored on line break. An operating relay per channel as limit level
alarm for control tasks is available as output. Overvoltage category (IEC 61010-1)
Pollution degree 2

Approvals

Worldwide approvals are available for VEGA instruments, e.g. for use in
hazardous areas, on ships or in hygienic applications.
The technical data in the respective safety instructions are valid for ap-
proved instruments (e.g. with Ex approval). In some cases, these data
can differ from the data listed herein.
You can find detailed information on the existing approvals with the ap-
propriate product on our homepage.

VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com VEGATOR 132 - 46841-EN-220412
Electrical connection

EL
4 5 2

1 2 3 1
2
1 3 EL pri /
sec OPEN

1 2 3

10 11 12 3

13 14 15 4

+ -
16 17 5

Wiring plan VEGATOR 132


1 Sensor circuit 1 (terminal 1 + 2) and Primary/Secondary connection (terminal
3)
2 Sensor circuit 2 (terminals 4 + 5)
3 Relay output 1
4 Relay output 2
5 Voltage supply

You can find details on electrical connection in the instrument operating


instructions on our homepage at www.vega.com/downloads.

Dimensions

20 mm 113 mm
(0.79") (4.45")

OPEN
55 mm
(2.17")
111 mm

92 mm
(4.37")

(3.62")

46 mm
(1.81")

56 mm
(2.20")

Dimensions VEGATOR 132

Information

You can find further information on the VEGA product line on our home-
page.
In the download section of our homepage you'll find operating
instructions, product information, industry brochures and approval
documents as well as device and adjustment software.

Contact

You can find your personal contact person at VEGA on our homepage
under " Contact".

VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com VEGATOR 132 - 46841-EN-220412