Safety Data Sheet (SDS)
According to Regulation (EC) No 1907/2006 (REACH), Annex II(COMMISSION REGULATION (EU) No 2015/830)
SS7065
Date of issue: 2015-09-22 Revision date: 2020-08-12 Version: R0014.0001
SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
1.1. Product identifier
Trade name/designation : SS7065
1.2. Relevant identified uses of the substance or mixture and uses advised against
1.2.1. Relevant identified uses
- Conformal Coating
1.2.2. Uses advised against
- Do not use except for purpose
1.3. Details of the supplier of the safety data sheet
Manufacturer/Supplier : KCC Corporation
Address : 35, Daejuk 2-ro, Daesan-eup, Seosan-si, Chungcheongnam-do
Telephone : 82-41-660-8700
Email :
[email protected] 1.4. Emergency telephone number
EU-wide emergency number : 112
See section 16.6 for the list of telephone number of National Helpdesks in the European Economic Area.
SECTION 2: HAZARD IDENTIFICATION
2.1. Classification of the substance/mixture
2.1.1. Classification according to Regulation (EC) No 1272/2008 CLP
- Flammable liquids : Category3, H226
2.2. Label elements
2.2.1. Labelling according to Regulation (EC) No 1272/2008 CLP
* Hazard Pictogram(s)
* Signal word : Warning
* Hazard statement(s)
- H226 Flammable liquid and vapour
* Precautionary statement(s)
1) Prevention
- P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.
- P233 Keep container tightly closed.
- P240 Ground/bond container and receiving equipment.
- P241 Use explosion-proof electrical/ventilating/lighting/equipment.
- P242 Use only non-sparking tools.
- P243 Take precautionary measures against static discharge.
- P280 Wear protective gloves/protective clothing/eye protection/face protection.
2) Response
- P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
- P370+P378 In case of fire: Use Suitable extinguishing media for extinction(Refer Section MSDS 5).
3) Storage
- P403+P235 Store in a well-ventilated place. Keep cool.
1/11
4) Disposal
- P501 Dispose of contents/container in accordance with local/regional/national/international regulation
2.3. Other hazards
- Not available
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS
3.1. Substances
- Not applicable
3.2. Mixtures
REACH
Classification
Name EC No. CAS No. registration % [weight]
[1272/2008/EC]
No.
Siloxanes and Silicones, di-Me,
- 142982-20-5 73 ~80 Not classified
[(trimethoxysilyl)oxy]-terminated
01-
Aquatic Choronic 4, H413
Octamethyltrisiloxane 203-497-4 107-51-7 2119970219- 7 ~ 14
Flam. Liq. 3, H226
31-XXXX
Trimethoxy(methyl)silane 214-685-0 1185-55-3 7 ~ 14 Flam. Liq. 2, H225
Bis(ethyl 3-oxobutanoato-
248-697-2 27858-32-8 1~6 Not classified
O1',O3)bis(2-propanolato)titanium
Secret - - 0 ~ 1미만 Not classified
SECTION 4: FIRST AID MEASURES
4.1. Description of first aid measures
General
- No general information.
Inhalation
- When exposed to large amounts of steam and mist, move to fresh air.
- Take specific treatment if needed.
Skin contact
- Flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.
- Wash contaminated clothing thoroughly before re-using.
Eye contact
- Do not rub your eyes.
- Immediately flush eyes with plenty of water for at least 15 minutes and call a doctor/physician.
Ingestion
- Please be advised by doctor whether induction of vomit is demanded or not.
- Rinse your mouth with water immediately.
4.2. Most important symptoms and effects, both acute and delayed
- Not available
4.3. Indication of any immediate medical attention and special treatment needed
- Notify medical personnel of contaminated situations and have them take appropriate protective measures.
SECTION 5: FIREFIGHTING MEASURES
5.1. Extinguishing media
Suitable extinguishing media
- Dry chemical, carbon dioxide, regular foam extinguishing agent, spray
Unsuitable extinguishing media
- Avoid use of water jet for extinguishing
5.2. Special hazards arising from the substance or mixture
Hazardous combustion products
- Not available
2/11
5.3. Advice for firefighters
- Cool containers with water until well after fire is out.
- Keep unauthorized personnel out.
- Notify your local firestation and inform the location of the fire and characteristics hazard.
- In case of conflagration, use automatic fire sprinkler. Major fire may require withdrawal, allowing the object itself to burn.
- Avoid inhalation of materials or combustion by-products.
- Keep containers cool with water spray.
- Use fire fighting procedures suitable for surrounding area.
- Vapor or gas is burned at distant ignition sources can be spread quickly.
- Due to the extremely low flash point, irrigating fire extinguishing may be less effective when put out a fire.
SECTION 6: ACCIDENTAL RELEASE MEASURES
6.1. Personal Precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
- Protective equipment: Wear proper protective equipment.
- Emergency procedures: Not applicable
- If required, notify relevant authorities according to all applicable regulations.
6.1.2. For emergency responders
- Wear proper personal protective apparatus as indicated in Section 8 and avoid skin contact and inhalation.
- Must work against the wind, let the upwind people to evacuate.
- Remove all sources of ignition.
- Handle the damaged containers or spilled material after wearing appropriate protective equipment
- Do not direct water at spill or source of leak.
6.2. Environmental precautions
- Prevent runoff and contact with waterways, drains or sewers.
- If large amounts have been spilled, inform the relevant authorities.
- Avoid dispersal of spilt material and runoff and contact with waterways, drains and sewers. If large spills, advise emergency services.
6.3. Methods and material for containment and cleaning up
6.3.1. For containment
- Don't use a brush or compressed air for cleaning surfaces or clothing.
- Clean up all spills immediately.
- No smoking, flame or ignition sources.
- Stop leak if safe to do so.
6.3.2. For cleaning up
- Large spill : Stay upwind and keep out of low areas. Dike for later disposal.
- Notify the central and local government if the emission reach the standard threshold.
- Disposal of waste shall be in compliance with the Wastes Control?Act
- Appropriate container for disposal of spilled material collected.
- Small leak: sand or other non-combustible material, please let use absorption.
- Wipe off the solvent.
- Dike for later disposal.
- Do not use plastic containers.
6.3.3. Other information
- Slippery when spilt.
6.4. Reference to other sections
- See Section 7 for information on safe handling.
- See Section 8 for information on personal protection equipment.
- See Section 13 for information on disposal.
SECTION 7: HANDLING AND STORAGE
7.1. Precautions for safe handling
3/11
- Since emptied containers retain product residue(vapor, liquid, solid) follow all MSDS and label warnings even after container is emptied.
- Avoid contact with incompatible materials.
- Operators should wear antistatic footwear and clothing.
- Do not inhale the steam prolonged or repeated.
- Avoid contact with heat, sparks, flame or other ignition sources.
7.2. Conditions for safe storage, including any incompatibilities
- Check regularly for leaks.
- Do not apply direct heat.
- Store according to current laws and regulations
- Keep in the original container.
7.3. Specific end use(s)
- See Section 1 for information on 1.2 Relevant identified uses.
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1. Control parameters
8.1.1. Occupational exposure limits
European Union (EU) Commission Directive 2006/15/EC (IOELVs)
- Not available
European Union (EU) Commission Directive 2006/15/EC (IOELVs) - Skin
- Not available
Greece Occupational Exposure Limits
- Not available
Netherlands Occupational Exposure Limits
- Not available
Denmark Indicative List of Organic Solvents
- Not available
Denmark List of Limit Values for Dust
- Not available
Latvia Occupational Exposure Limit Values (OELV) for Chemical Substances in the Work Environment AtmbExcel Air & Hydraulics9
- Not available
Latvia Carcinogens and their Occupational Exposure Limit Values (OELV)
- Not available
Bulgaria Occupational Exposure Limits
- Not available
Bulgaria Limit values for the chemical agents in the air at the working environment
- Not available
Sweden Occupational Exposure Limit Values
- Not available
Sweden Occupational Exposure Limit Values and Measures against Air Contaminants
- Not available
Spain Changes Proposed for Occupational Exposure Limit Values
- Not available
Spain Occupational Exposure Limit for Chemical Agents
- [Secret1] - VLA- ED : 3 mg/㎥ (Particulates (insoluble) not otherwise classified: Respirable fraction)
Slovak Republic Highest Admissible Exposure Limits
- Not available
Slovak Republic Highest Admissible Exposure Limits - Solid aerosols predominately with fibrogenic effect
- Not available
Slovak Republic Highest Admissible Exposure Limits - Solid aerosols with possible fibrogenic effect
- Not available
Slovak Republic Highest Admissible Exposure Limits - Solid aerosols predominately with nonspecific effect
- Not available
Ireland Occupational Exposure Limits
- [Secret1] - Occupational Exposure Limit Value (8-hour reference period) : 10 mg/㎥ (Dusts non-specific total inhalable)
4/11
UK Workplace Exposure Limits (WELs)
- Not available
Austria Technical Exposure Limits (TRK Values)
- Not available
Austria Occupational Exposure Limits - Maximum Workplace Concentrations (MAK)
- Not available
Italy Occupational Exposure Limits
- Not available
Czech Republic Occupational Exposure Limits (PEL and NPK-P)
- Not available
Czech Republic Occupational Exposure Limits - Dusts predominately with fibrogenic effect
- Not available
Czech Republic Occupational Exposure Limits - Dusts with possible fibrogenic effect
- Not available
Czech Republic Occupational Exposure Limits - Dusts predominately with nonspecific effect
- Not available
Czech Republic Occupational Exposure Limits - Dusts predominately with irritating effect
- Not available
Czech Republic Occupational Exposure Limits - Mineral fibrous dusts
- Not available
Poland Workplace Maximum Allowable Concentration - Dust
- Not available
Poland Workplace Maximum Allowable Concentration
- [Bis(ethyl 3-oxobutanoato-O1',O3)bis(2-propanolato)titanium0] - NDS 8h/d - 40h/w : 10 mg/㎥ ; NDSCh 15min : 30 mg/㎥ (Tytan i jego
związki - w przeliczeniu na Ti)
France Threshold Limit Values for Occupational Exposure - VLE/VME
- [Secret1] - VME : 10. 5 mg/㎥ (Poussières réputées sans effet spécifique)
Finland Occupational Exposure Levels - Concentrations Known to be Harmful
- [Secret1] - HTP Value (8h) : 3 ppm ; HTP Value (8h) : 28 mg/㎥ ; HTP Value (15min) : 6 ppm ; HTP Value (15min) : 55 mg/㎥ (3-
Aminopropyltrietoxisilan)
Hungary Occupational Exposure Limits
- [Secret1] - TWA : 2 mg/㎥ (porok (szálló porok) egyéb porok [Á sványi porok - Talkum (azbesztmentes)])
- [Secret2] - TWA : 2 mg/㎥ (porok (szálló porok) egyéb porok [Á sványi porok - Szénpor (kvarc <5% m/m)])
- [Secret3] - TWA : 10 mg/㎥ (porok (szálló porok) egyéb porok [Á sványi porok - Talkum (azbesztmentes)])
- [Secret4] - TWA : 5 mg/㎥ (porok (szálló porok) egyéb porok [Egyéb szerves porok])
8.1.2. Recommended Monitoring Procedures
- Personal, workplace atmosphere or biological monitoring may be required to determine the effectiveness of the ventilation or other control
measures and/or the necessity to use respiratory protective equipment.
8.1.3. DNEL/PNEC - Values
- Not available
8.2. Exposure controls
8.2.1. Appropriate engineering controls
- Business owner is recommended to maintain below recommended exposure limits for the working place with general exhaust of
gas/vapour/mist/fume.
8.2.2. Individual protection measures, such as personal protective equipment
Hand protection
- Wear appropriate chemical resistant glove.
Eye protection
- Wear primary eye protection such as splash resistant safety goggles with a secondary protection face shield.
- Provide an emergency eye wash station and quick drench shower in the immediate work area.
Respiratory Protection
- Respiratory protection is ranked in order from minimum to maximum.
- Consider warning properties before use.
- Any chemical cartridge respirator with organic vapor cartridge(s).
- Any chemical cartridge respirator with a full facepiece and organic vaporcartridge(s).
5/11
- Any air-purifying respirator with a full facepiece and an organic vapor canister.
- For Unknown Concentration or Immediately Dangerous to Life or Health : Any supplied-air respirator with full facepiece and operated in a
pressure-demand or other positive-pressure mode in combination with a separate escape supply. Any self-contained breathing apparatus with
a full facepiece.
- Under conditions of frequent use or heavy exposure, Respiratory protection may be needed.
Skin protection
- Wear appropriate chemical resistant protective clothing.
Others
- It is necessary to wear protective clothes and other protection equipment. Cover your face, head and neck.
- Prior to removing protective garments the employee should undergo decontamination and be required to shower upon removal of the
garments and hood.
- Emergency deluge showers and eyewash fountains, supplied with potable water, should be located near, within sight of, and on the same
level with locations where direct exposure is likely.
Thermal hazards
- Not available
8.2.3 Environmental exposure controls
- Do not let product enter drains. For ecological information refer to section 12.
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
9.1. Information on basic physical and chemical properties
Appearance(State) Liquid(Viscous liquid)
Appearance(Color) Light yellow
Odor Characteristic odor
Odor threshold Not available
pH Not available
Melting point/Freezing point Not available
Initial boiling point and boiling range Not available
Flash point 40 ℃
Evaporation rate Not available
Flammability(solid, gas) Not available
Upper/Lower Flammability or explosive limits Not available
Vapour pressure Not available
Vapour density Not available
Relative density 0.95
Solubility Not available
Partition coefficient of n-octanol/water Not available
Autoignition temperature Not available
Decomposition temperature Not available
Viscosity 150 cP
Explosive properties Not available
Oxidising properties Not available
9.2. Other information
- Not available
SECTION 10: STABILITY AND REACTIVITY
10.1. Reactivity
- Product is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
10.2. Chemical Stability
- This material is stable under recommended storage and handling conditions.
10.3. Possibility of hazardous reactions
- Cylinders exposed to fire may vent and release flammable gas.
10.4. Conditions to avoid
- Avoid contact with incompatible materials and condition.
6/11
- Avoid : Accumulation of electrostatic charges, Heating, Flames and hot surfaces
- Avoid contact with heat, sparks, flame or other ignition sources.
10.5. Incompatible materials
- Not available
10.6. Hazardous decomposition products
- May emit flammable vapour if involved in fire.
SECTION 11: TOXICOLOGICAL INFORMATION
11.1. Acute toxicity
- Oral
- Product (ATEmix) : >5000mg/kg
- [Trimethoxy(methyl)silane] : LD50 = 11685 ㎎/㎏ Rat (ECHA), 12.3 ml/kg Rat (THOMSON)
- [Secret] : LD50 = 300 ~ 2000 mg/kg
- [Secret] : LD50 = 7010 ㎎/㎏ Rat (SIDS)
- [Secret] : LD50 > 10000 ㎎/㎏ Rat(NLM;ChemIDPlus)
- [Secret] : LD50 = 16000 ㎎/㎏ Rat (NLM, RTECS)
- Dermal
- Product (ATEmix) : Not available
- [Secret] : LD50 3,970 mg/kg Rabbit (SIDS)
- [Secret] : LD50 = 16000 ㎎/㎏ Rabbit (NLM, RTECS)
- Inhalation
- Product (ATEmix) : Not available
- [Secret] : Steam LD50 > 5.3 ㎎/ℓ Rat (SIDS)
- [Secret] : Dust LC50 > 1.8 ㎎/ℓ 4 hr Mouse (KOSHA)
11.2. Skin corrosion/irritation
- Not available
11.3. Serious eye damage/irritation
- Not available
11.4. Respiratory sensitization
- Not available
11.5. Skin sensitization
- Not available
11.6. Germ cell mutagenicity
- Not available
11.7. Carcinogenicity
- IARC
- Not available
- OSHA
- Not available
- ACGIH
- Not available
- NTP
- Not available
- EU CLP
- Not available
11.8. Reproductive toxicity
- Not available
11.9. Specific target organ toxicity(single exposure):
7/11
- Not available
11.10. Specific target organ toxicity(repeated exposure):
- Not available
11.11. Aspiration hazard
- Not available
SECTION 12: ECOLOGICAL INFORMATION
12.1. Toxicity
12.1.1. Fish
- [Trimethoxy(methyl)silane] : LC50 32662.842 ㎎/ℓ 96 hr (Estimate)
- [Secret] : LC50 = 237 ㎎/ℓ 96 hr Oncorhynchus mykiss (SIDS)
- [Secret] : LC50 0.000844 ㎎/ℓ 96 hr (estimate)
- [Secret] : LC50 0.021 ㎎/ℓ 96h(estimate)
12.1.2. Invertebrate
- [Trimethoxy(methyl)silane] : LC50 29104.090 ㎎/ℓ 48 hr (Estimate)
- [Secret] : EC50 = 710 ㎎/ℓ 48 hr Daphnia magna (SIDS)
- [Secret] : LC50 0.00108 ㎎/ℓ 48 hr (Estimated LC50 > water solubility not classified acute toxicity) (EPI Suite)
- [Secret] : LC50 0.024 ㎎/ℓ 48 hr (estimate)
12.1.3. Algae
- [Trimethoxy(methyl)silane] : EC50 1.000 ㎎/ℓ 96 hr (Estimate)
- [Bis(ethyl 3-oxobutanoato-O1',O3)bis(2-propanolato)titanium] : EC50 1441.435 ㎎/ℓ 96 hr (Estimate)
- [Secret] : EC50 = 350 ㎎/ℓ 96 hr Selenastrum capricornutum (SIDS)
- [Secret] : EC50 0.007 ㎎/ℓ 96 hr (estimate)
- [Secret] : EC50 0.085 ㎎/ℓ 96 hr(estimate)
12.2. Persistence and degradability
12.2.1. Persistence
- [Octamethyltrisiloxane] : log Kow 4.8 (NLM)
- [Trimethoxy(methyl)silane] : log Kow -0.67 (Estimate)
- [Bis(ethyl 3-oxobutanoato-O1',O3)bis(2-propanolato)titanium] : log Kow = 0.02
- [Secret] : log Kow = -0.92 (Estimate)
- [Secret] : log Kow 6.64 (Estimate)
12.2.2. Degradability
- Not available
12.3. Bioaccumulative potential
12.3.1. Bioaccumulation
- [Octamethyltrisiloxane] : BCF 682.4 (Estimate)
- [Bis(ethyl 3-oxobutanoato-O1',O3)bis(2-propanolato)titanium] : BCF 3.162 (Estimate)
- [Secret] : BCF = 2160 (Estimate)
- [Secret] : BCF 11200 (Estimate)
12.3.2. Biodegradability
- [Secret] : Biodegradability = 37 (%) 28 day (SIDS)
- [Secret] : (non-biodegradable, not degraded and has a high potential to accumulate in vivo (Estimate) (EPI Suite)
12.4. Mobility in soil
- [Octamethyltrisiloxane] : Koc 4.166 (Estimate)
- [Bis(ethyl 3-oxobutanoato-O1',O3)bis(2-propanolato)titanium] : Koc = 7.008 (Low potential for soil adsorption)
- [Secret] : Koc = 29660000 (Estimates, Low potential for soil adsorption)
- [Secret] : Koc = 578700 (Can be adsorbed in the soil)
12.5. Results of PBT and vPvB assessment
8/11
- Not available
12.6. Other adverse effects
- Not available
SECTION 13: DISPOSAL CONSIDERATIONS
13.1. Waste treatment methods
- Stabilization and minimization treatment by incineration or similar method can be applied, if more than two kinds of designated wastes are in
mixture state and it is impractical to separate them
- Oil water separation technology shall be applied as pre-waste treatment if it is applicable
- It shall be treated by incineration
- Anyone with business license number who generates industrial wastes shall treat the waste by him/herself or by entrusting to the legal entities who
treat the wastes, recycle the wastes of others or install and operate the waste treatment facilities according to the Wastes Control Act
- Dispose of waste in accordance with all applicable laws and regulations.
SECTION 14: TRANSPORT INFORMATION
14.1. UN No.
14.1.1. UN No. (ADR/RID/ADN)
- 1993
14.1.2. UN No. (IMDG)
- 1993
14.1.3. UN No. (ICAO)
- 1993
14.2. UN proper shipping name
- COMPOUNDS, CLEANING LIQUID
14.3. Transport hazard class(es)
14.3.1. ADR/RID/ADN Class
-3
14.3.2. ADR/RID/ADN Class
- Class : 3, FLAMMABLE LIQUID, N.O.S.
14.3.3. ADR Label No.
-3
14.3.4. IMDG Class
-3
14.3.5. ICAO Class/Division
-3
14.3.6. Transport Labels
14.4. Packing group
14.4.1. ADR/RID/ADN Packing group
-I
14.4.2. IMDG Packing group
-Ⅲ
14.4.3. ICAO Packing group
9/11
-I
14.5. Environmental hazards
- Not applicable
14.6. Special precautions for user
- Local transport follows in accordance with Dangerous goods Safety Management Law.
- Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.
- EmS FIRE SCHEDULE : F-E (Non-water-reactive flammable liquids)
- EmS SPILLAGE SCHEDULE : S-E (Flammable liquids, floating on water)
- Emergency Action Code : l3YE
- Hazard No.(ADR) : 33
- Emergency Action Code : 1 (D/E)
- Air transport(IATA): This product is NOT classified as dangerous for IATA Transport.
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
- Not applicable
SECTION 15: REGULATORY INFORMATION
15.1. Safety, health and environmental regulation / legislation specific for the substance or mixture
15.1.1. Europe regulatory
15.1.1.1 REACH Restricted substance under REACH
- Not applicable
15.1.1.2 REACH Substances subject to authorization under REACH
- Not applicable
15.1.1.3 REACH SVHC
- Not applicable
15.1.1.4 Europe PBT
- Not applicable
15.1.1.5 European Union (EU) Transport of Dangerous Goods by Road - Dangerous Goods List
- Not applicable
15.2. Chemical Safety Assessment
- Not conducted
SECTION 16: OTHER INFORMATION
16.1. Indication of changes
- The Safety Data Sheet has been reviewed and the data therein were revised and laid out according the requirements of the Commission Regulation
(EU) No. 453/2010
16.2. Abbreviations and acronyms
- 1272/2008 CLP : Classification, Labelling and Packaging regulation.
- REACH : Registration, Evaluation and authorisation of chemical substances.
- DNEL : Derive no effects level
- PNEC : Predicted no effect concentration
16.3. Key literature references and sources for data
- This Safety Data Sheet was compiled with data and information from the following sources: RTECS, ECOSAR, HSDB, SIDS SIAP,
ChemWATCH, CESAR, Chemical DB
16.4. Classification procedure
- The mixture classification has been derived based on the classification of the individual components in accordance with the rules set out in
Regulation (EC) No 1272/2008 (CLP) as well as the translation tables in Annex VII to the same regulation.
16.5. Training advice
- Not applicable
16.6. Further information
10/11
- The (M)SDS is a Hazard Communication tool and should be used to assist in the Risk Assessment. Many factors determine whether the reported
Hazards are Risks in the workplace or other settings. Risks may be determined by reference to Exposures Scenarios. Scale of use, frequency of use
and current or available engineering controls must be considered.
- This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental
requirements only.
- It should not therefore be construed as guaranteeing any specific property of the product.
- Contact a poison control centre, List of Telephone Numbers : AUSTRIA (Vienna Wien) +43 1 406 43 43; BELGIUM (Brussels Bruxelles) +32 70
245 245; BULGARIA (Sofia) +359 2 9154 409; CZECH REPUBLIC (Prague Praha) +420 224 919 293; DENMARK (Copenhagen) 82 12 12 12;
ESTONIA (Tallinn) 112; FINLAND (Helsinki) +358 9 471 977; FRANCE (Paris) +33 1 40 0548 48; GERMANY (Berlin) +49 30 19240;
GREECE (Athens Athinai) +30 10 779 3777; HUNGARY (Budapest) 06 80 20 11 99; ICELAND (Reykjavik) +354 525 111, +354 543 2222;
IRELAND (Dublin) +353 1 8379964; ITALY (Rome) +39 06 305 4343; LATVIA (Riga) +371 704 2468; LITHUANIA (Vilnius) +370 5 236 20 52
or +370 687 53378; MALTA (Valletta) 2425 0000; NETHERLANDS (Bilthoven) +31 30 274 88 88; NORWAY (Oslo) 22 591300; POLAND
(Gdansk) +48 58301 65 16 or +48 58 349 2831; PORTUGAL (Lisbon Lisboa) 808 250 143; ROMANIA (Bucharest) +40 21 3183606 SLOVAKIA
(Bratislava) +421 2 54 77 4166; SLOVENIA (Ljubljana) + 386 41 650 500; SPAIN (Barcelona) +34 93 227 98 33 or +34 93 227 54 00 bleep 190;
SWEDEN (Stockholm) 112 or +46 8 33 12 31 (mon-fri 9.00-17.00); UNITED KINGDOM (London) 112 or 0845 4647 (NHS Direct).
11/11