Item 1. Cementitious Fireproofing
PRODUCT: MONOKOTE MK-6HY
DESCRIPTION: Standard Density Cementitious Fireproofing
THEORETICAL COVERAGE: 3.4 sqm at 25mm thickness per bag
PACKAGING: 21.5 kg bag
UNIT PRICE: SAR 53.00 per bag
Item 2. Cementitious Fireproofing
PRODUCT: MONOKOTE Z-106/HY
DESCRIPTION: Medium Density Cementitious Fireproofing
THEORETICAL COVERAGE: 2.3 sqm at 25mm thickness per bag
PACKAGING: 20.5 kg bag
UNIT PRICE: SAR 53.00 per bag
Item 3. Accessories
PRODUCT: MONOKOTE ACCELERATOR
DESCRIPTION: Injection component for MK-6/HY
THEORETICAL COVERAGE: 30 bags : 1,000 bags of MK-6/HY
PACKAGING: 27.2 kg bag
UNIT PRICE: SAR 65.00 per bag
Item 4. Accessories
PRODUCT: FIREBOND
DESCRIPTION: Recommended bonding agent for AVI fireproofing
products
THEORETICAL COVERAGE: 10-12 sqm per liter (on steel) / 8-10 sqm per liter (on
concrete)
PACKAGING: 20 ltr. Pail
UNIT PRICE: SAR 280.00 per pail
1
NOTE/S: Theoretical coverage is based on optimal application settings.
Practical results will vary.
DELIVERY TERMS: Ex-works Dammam
AVAILABILITY: Min. 4-7 days from receipt of PO depending on quantity.
PAYMENT TERMS: Cash Advance / Wire Transfer
QUOTATION 1 month from date of quotation
VALIDITY: PRICES ARE EXCLUSIVE OF VAT
We do hope that the above quotation meets your favorable approval and should you need
any further clarification, please feel free to contact the undersigned.
Best regards,
Ralph Malabanan
Sales Support
2
MONOKOTE MK-6/HY
Product Data and Application Instructions
Product Information discarded. Stock of material is to be rotated and used before
its expiration date.
Monokote® Type MK-6/HY is a single component, millmixed
spray-applied fire resistive material (SFRM) which requires Steel and Concrete Surfaces
only the addition of water on the job site to form a consistent,
pumpable slurry. Type MK-6/HY is designed for use on structural 1. Prior to the application Monokote® Type MK-6/HY
steel columns, beams, joists, trusses and floor and roof decking. fireproofing, an inspectional shall be made to determine that
all steel and concrete surfaces are acceptable to receive
Features and Benefits fireproofing. The steel to be fireproofed shall be free of oil,
grease, excess rolling compounds or lubricants, loose mill
Monokote cementitious fireproofing offers many significant scale, excess rust, non-compatible primer, lock down agent
advantages to the architect, owner, applicator and building or any other substance that will impair proper adhesion.
occupant. These include: Where necessary, the cleaning of steel surfaces to receive
fireproofing shall be the responsibility of the general
• Proven in-place performance
contractor.
• Low in-place cost
2. The project architect shall determine if the painted/primed
• Fast, efficient application structural steel to receive fireproofing has been tested in
accordance with ASTM E-119, to provide the required fire
• UL fire tested and factory inspected
resistance rating.
• Building Code compliant
3. Many Fire Resistance Designs allow the use of painted metal
floor or roof deck in place of galvanized decking. Painted
Delivery and Storage
decking must be UL listed in the specific fire resistance
designs and must carry the UL classification marking.
1. All material to be used for fireproofing shall be delivered
in original unopened packages bearing the name of the 4. Prior to application of Monokote® Type MK-6/HY, a bonding
manufacturer, the brand, the name of the manufacturer, the agent, approved by the fireproofing manufacturer, shall be
brand and proper Underwriters Laboratories Inc. labels for applied to all concrete substrates to receive Type MK-6/HY.
fire hazard and fire resistance classifications.
5. Fireproofing to the underside of roof deck assemblies shall
2. The material shall be kept dry until ready for use. Packages be done only after roofing application is complete and roof
of material shall be kept off the ground, under cover and traffic has ceased.
away from sweating walls and other camp surfaces. All
6. No fireproofing shall be applied prior to completion of
bags that have been exposed to water before use shall be
concrete work on steel decking
Physical Performance Characteristics
Physical Properties Recommended Specification Test Method
Dry density, minimum average 240 kg/m3 (15 pcf) ASTM E 605
Bond strength 16.9 KPa (352 psf) ASTM E 736
Compression, 10% deformation 220 KPa (32 psi) ASTM E 761
Air erosion 0.000 g/m2 (0.000 g/ft2) ASTM E 859
High velocity air erosion No continued erosion after 4 hours ASTM E 859
Corrosion Does not contribute to corrosion ASTM E 937
Bond impact No cracking, spalling or delamination ASTM E 760
Deflection No cracking, spalling or delamination ASTM E 759
Resistance to mold growth No growth after 60 days ASTM G 21
Surface burning characteristics Flame Spread = 0 ASTM E 84
Smoke Developed = 0
Combustibility Less than 5 M J/m2 total, 20 kW/m2 peak heat release ASTM E 1354
Impact penetration Max 6 cm abraded
3
Developed by City of San Francisco
Abrasion resistance Max 15 cm abraded
3
Developed by City of San Francisco
*Actual laboratory tested values meet or exceed recommended values. Test reports are available on request from your AVI sales representative.
www.avi-sa.com | [email protected]
Arabian Vermiculite Industies P.O. Box 7137, Dammam 31462, Saudi Arabia Tel: +966 13 847 1450 Fax: +966 13 847 1575
Mixing Temperature and Ventilation
1. Monokote fireproofing shall be mixed by machine in a 1. An air and substrate temperature of 4.4°C (40°F) minimum
conventional, plaster-type mixer or a continuous mixer shall be maintained for 24 hours prior to application, during
specifically modified for cementitious fireproofing. The mixer application and for a minimum of 24 hours after application
shall be kept clean and free of all previously mixed material. of Monokote.
The mixer speed in a conventional mixer shall be adjusted
2. Provisions shall be made for ventilation to properly dry the
to the lowest speed which gives adequate blending of the
fireproofing after application. In enclosed areas lacking
material and a mixer density of 673–769 kg/m3 (42- 48 pcf).
natural ventilation, air circulation and ventilation must be
2. Using a suitable metering device and a conventional mixer, provided to achieve a minimum total air exchange rate of 4
all water shall be first added to the mixer as the blades turn. times per hour until material is substantially dry.
Mixing shall continue until the mix is lump-free, with a creamy
texture. All material is to be thoroughly wet. Target density
of 720 ±50 kg/m3 (45 ±2 pcf) is most desirable. Overmixing
Monokote will reduce pumping rate.
Application
1. Application of Monokote fireproofing can be made in the
following sequence:
• For thickness of approximately 13mm (1/2 in.) or less,
apply in one pass.
• For thickness of 16mm (5/8 in.) or greater, apply
subsequent passes after the first coat has set.
2. Spatterkote™ SK-3 shall be applied to all flat plate cellular
deck units and below all bottomless trench headers prior to
application of Type MK-6/HY. Spatterkote shall be applied in
accordance with the manufacturer’s application instructions.
3. Spatterkote SK-3 shall be applied to roof decking where
required prior to application of Monokote. Field Test
4. Monokote fireproofing material shall not be used if it contains 1. The architect will will select an independent testing
partially set, frozen or caked material. laboratory (for which the owner will pay) to sample and verify
5. Monokote shall have a minimum average dry, inplace density the thickness and density of the fireproofing in accordance
of 240 kg/m3 (15 lbs./ft3) with the the applicable building code.
6. Monokote is formulated to be mixed with water at the job 2. The architect will select, and the owner will pay an
site. independent testing laboratory to randomly sample and
verify the bond strength of the fireproofing in accordance
7. Monokote Accelerator is to be used with Monokote Type with the provisions of ASTM E 736.
MK-6/HY to enhance set characteristics and product
yield. The Monokote Accelerator is injected into the 3. Results of the above tests will be made available to all parties
Monokote Type MK-6/HY at the spray gun. Monokote at the completion of pre-designated areas which shall have
Accelerator shall be mixed and used according to been determined at a pre-job conference.
manufacturer’s recommendations.
Safety
8. Monokote is applied directly to the steel, at various rates
of application which will job dependent, using standard 1. Monokote is slippery when wet. The general contractor
plastering type equipment or continuous mixer/pump units. A and applicator shall be responsible for posting appropriate
spray gun with a properly sized orifice and spray shield, and cautionary SLIPPERY WHEN WET signs. Signs should be
air pressure at the nozzle of approximately 38 KPa (20 psi) posted in all areas in contact with wet fireproofing material.
will provide the correct hangability, density and appearance. Anti-slip surfaces should be used on all working surfaces.
NOTE: If freshly sprayed Monokote does not adhere properly, it 2. A Material Safety Data Sheets for Monokote® Type MK-6/
is probably due either to a too wet mix, poor thickness control, or HY is available upon request
an improperly cleaned substrate.
www.avi-sa.com
Monokote Type Z-106/HY®
Portland Cement Based, Medium Density Cementitious Fireproofing
Product Information Delivery and Storage
Monokote Z-106/HY® is Portland cement based cementitious a. All material to be used for fireproofing shall be delivered
fireproofing designed to meet specific commercial and industrial in original unopened packages bearing the name of the
fire protection requirements on structural steel members, floor/ manufacturer, the brand, the name of the manufacturer, the
ceiling and roof/ceiling assemblies. brand and proper Underwriters Laboratories Inc. labels for
fire hazard and fire resistance classifications.
Monokote Z-106/HY® is hard, moisture resistant and suitable
for interior areas where resistance to moisture and abrasion b. The material shall be kept dry until ready for use. Packages
is needed. Formulated for use with Grace’s patented Injection of material shall be kept off the ground, under cover and
System. Monokote Z-106/HY® offers high yield and improved away from sweating walls and other camp surfaces. All
application characteristics while providing resistance to repeated bags that have been exposed to water before use shall be
physical contact and/or high humidity. discarded. Stock of material is to be rotated and used before
its expiration date.
Applications
Steel and Concrete Surfaces
Monokote Z-106/HY® can be used for interior, exposed
applications where abrasion, high humidity, and damage a. Prior to the application Z-106/HY fireproofing, an inspectional
resistance are desired such as: shall be made to determine that all steel and concrete
• Special use areas in commercial buildings surfaces are acceptable to receive fireproofing. The steel
• Transportation terminals to be fireproofed shall be free of oil, grease, excess rolling
• Convention centers compounds or lubricants, loose mill scale, excess rust, non-
• Stairwells compatible primer, lock down agent or any other substance
• Parking garages that will impair proper adhesion. Where necessary, the
• Elevator shafts cleaning of steel surfaces to receive fireproofing shall be the
• Light manufacturing areas and facilities responsibility of the general contractor.
• Mechanical rooms
b. Prior to the application of Monokote Z-106/HY®, a bonding
• Gymnasiums and pool areas
agent approved by the fireproofing manufacturer shall be
• Correctional facilities
applied to all substrates to receive Z-106. There are two
exceptions to this requirement:
Benefits
1. No bonding agent is required when Monokote Z-106/
Monokote Z-106/HY® offers the following advantages to the HY® is applied uninjected to bare steel and
architect, owner, applicator and building occupant.
2. No bonding agent is required when bond tests run in
Durability – 100% Portland cement binder provides increased accordance to the Coatings Materials section of the
durability in interior environments where high-traffic resistance to Underwriters Laboratories Fire Resistance Directory
physical abuse is required. Volume 1 indicate that a bonding agent is not required
for Monokote Z-106/HY® in conjunction with the specific
Moisture Resistant – Provides excellent resistance to high
primed or painted structural steel.
humidity and condensation.
c. The project architect shall determine if the painted/rimed
Quick Set – HY formulation allows use with Grace patented
structural steel to receive fireproofing has been tested in
Injection System for high-yield and quick set.
accordance with ASTM E-119, to provide the required fire
Applicator Friendly – Low pumping pressures allow use of small resistance rating.
diameter hoses for increased maneuver ability and greater
distances. d. No fireproofing to the underside of roof deck assemblies
shall be done only after roofing application is complete and
Non-Toxic – The factory-mixed blend of common Portland roof traffic has ceased.
cement and inert materials require only the addition of water for
mixing and application.
www.avi-sa.com | [email protected]
Arabian Vermiculite Industies P.O. Box 7137, Dammam 31462, Saudi Arabia Tel: +966 13 847 1450 Fax: +966 13 847 1575
Recommended Specifications - Medium Density Products
Physical Properties Monokote Z-106/HY® Test Method Laboratory Test* Value
Minimum density 22 pcf (352 kg/m ) 3
ASTM E605 See note below**
Minimum bond strength 2,000 psf (94.5 kN/m ) 2
ASTM E736 Greater than 2,000 psf (94.5 kN/m2)
Minimum compressive 100 psi (680 kPa) ASTM E761 Greater than 100 psi (680 kPa)
strength @ 10 deformation
Deflection and bond impact No cracking ASTM E759 Pass
No delamination ASTM E760 Pass
Air erosion 0.000 gr/ft2 (0.000 gr/m2) ASTM E859 0.000 gr/ft2 (0.000 gr/m2)
Mold inhibitor Yes ASTM G21 Pass / No growth
Standard color Gray
*Actual laboratory tested values meet or exceed Grace’s recommended value.
**ASTM test methods modified where required, for high density, high performance products.
Mixing orifice and spray shield and air pressure at the nozzle of
approximately 20 psi (.014 MPa), will provide the correct
a. Monokote Z-106/HY® fireproofing shall be mixed by hangability, density and appearance.
machine in a conventional, plaster-type mixer or a
continuous mixer specifically modified for cementitious Temperature and Ventilation
fireproofing. The mixer shall be kept clean and free
of all previously mixed material. The mixer speed in a a. An air and substrate temperature of 40°F (4.4°C) minimum
conventional mixer shall be adjusted to the lowest speed shall be maintained for 24 hours prior to application, during
which gives adequate blending of the material and a mixer application and for a minimum of 24 hours after application
density of 38-43 pcf (610-690 kg/m3) of Monokote Z-106/HY®.
b. Using a suitable metering device and a conventional b. Provisions shall be made for ventilation to properly dry the
mixer, all water shall be first added to the mixer as the fireproofing after application. In enclosed areas lacking
blades turn. Mixing shall continue until the mix is lump- natural ventilation, air circulation and ventilation must be
free, with a creamy texture. All material is to be thoroughly provided to achieve a minimum total air exchange rate of 4
wet. Target density of 38-43 pcf (610-690 kg/m3) is most times per hour until material is substantially dry.
desirable. Over-mixing Monokote Z-106/HY® will reduce
pumping rate and will negatively effect in-place density and Field Test
mechanical properties.
a. The architect will select an independent testing laboratory
Application (for which the owner will pay) to sample and verify the
thickness and density of the fireproofing in accordance with
a. Application of Monokote Z-106/HY® fireproofing can be the provisions of ASTM E605 (current edition), Standard
made in the following sequence: Test Method for Thickness and Density of Sprayed Fire-
1. Required fire rating thickness will determine if a multi- Resistive Material Applied to Structural Members or
pass operation is required. If the first pass can be Uniform Building Code Standard No. 7-6 Thickness and
applied at a thickness sufficient to obtain the required Density Determination for Spray Applied Fireproofing.
rating a second pass will not be required. Where samples are or irregular share (or sprayed texture),
the displacement method (ASTM E605 published in AWCI
2. Where the full required thickness cannot be applied in
Technical Manual 12-A) shall be used to determine in-place
a single pass, subsequent passes can be applied only
fireproofing density.
after the first coat has set.
b. The architect will select an independent testing laboratory
b. Monokote Z-106/HY® fireproofing material shall not be
(for which the owner will pay) to randomly sample and
used if it contains partially set, frozen or caked material.
verify the bond strength of the fireproofing in accordance
c. Monokote Z-106/HY® shall have a minimum average dry, with the provisions of ASTM E736.
in-place density of 22 pcf (352 kg/m3)
c. Results of the above tests will be made available to all
d. Monokote Z-106/HY® is formulated to be mixed with water parties at the completion of pre-designated areas which
at the job site. shall have been determined at a pre-job conference.
e. Monokote Accelerator may be used with Monokote Z-106/ Safety
HY® to enhance set characteristics and product yield. The
Monokote Accelerator is injected into the Monokote Z-106/ a. Monokote Z-106/HY® is slippery when wet. The general
HY® at the nozzle of the spray gun. Monokote Accelerator contractor and applicator shall be responsible for posting
shall be mixed and used according to manufacturers’ appropriate cautionary SLIPPERY WHEN WET signs.
recommendations. Signs should be used on all working surfaces.
f. Monokote Z-106/HY® is applied directly to the steel at b. Material Safety Data Sheets for Monokote Z-106/HY® is
various rates of application which will be job dependent, available upon request.
using standard plastering type equipment or continuous
mixer/pump units. A spray gun, with a properly sized
www.avi-sa.com
Monokote® Accelerator
Uses
Monokote® Accelerator is used to increase the yield and accelerate the setting of Monokote
MK-6/HY, when used with Monokote Injection Machines. This allows Monokote® MK-6/HY®
to set in 10-20 minutes. The use of Monokote® Accelerator with MK-6® results in a lower
installed cost.
Product Information
Product : Aluminum Sulphate
Formula : Al2(SO4)3 XH2O(X=10)
UN NO : NA
Dangerous Goods Class : None Allocated
Type : White or Grey granule
Size: 0-5mm
Soluble in water
Properties
Melting Point : 86°C
Flash Point : NA
Auto Ignition Temp : NA
Specification
Al2O3 : 17-18%
Fe (As Fe2O3) : 0.02% (max)
Water Insoluble Matter : 0.3%
pH (1% solution) : 2.5-4.0
Packing : 27.2 kg/bag
Application
For preparation, mixing and application, please refer to our simplified yield kit chart.
Other Information
For further uses and application, please refer to our MSDS.
www.avi-sa.com | [email protected]
Arabian Vermiculite Industies P.O. Box 7137, Dammam 31462, Saudi Arabia Tel: +966 13 847 1450 Fax: +966 13 847 1575
Firebond
Bonding Agent
Description Firebond is a water-based product with very low VOC content of
0.5g per liter.
Firebond is a styrene acrylic emulsion and is UL classified
bonding agents approved for use with any of the fire protection Refer to AVI product literature to determine acceptability of fire
or acoustical treatment products manufactured by Arabian protection or acoustical treatment products for the intended use.4
Vermiculite Industries. It is non-toxic, non-flammable and ready
to use. Firebond is classified in compliance with ASTM E-119
Footnotes
and listed in the UL fire resistance directory, category CBUI,
encapsulant materials. 1. Refer to the “Spray Material” section (pp.10-11) of the
Underwriters Laboratories, Inc. Fire Resistance Directory
Applications for requirements/restrictions to the use of primed/painted
structural steel in fire resistance designs.
Firebond may be used as a bonding agent or surface sealer for
the following applications. 2. The use of Retro-Guard Types RG and RG1 is often
associated with abatement projects. These products are not
1. As a bonding agent over polystyrene or urethane foam
substitutes for UL classified post-removal lockdowns. Refer
insulation prior to application of Zonolite 3306 Thermal
to the Encapsulant Materials (CBUI) category of the UL Fire
Barrier
Resistance Directory for additional information.
2. As a bonding agent over primed/painted structural steel
3. The use of a surface sealer over Sonotex 1 or any acoustical
(columns, beams and joists)1 prior to application of Monokote
treatment may reduce the NRC value of the installed product.
Type MS-5 and MK-6, Zonolite Type 105, Zonolite 106,
Zonolite 146, and Retro-Guard Types RG-RG-12, Avikote 4. Monokote, Retro-Guard, Sonotex and Zonolite are
AV650 and Avikote AV800 registered trademarks of Grace Construction and Packaging
Applied Technologies, formerly W.R. Grace and Company,
3. As a bonding agent over concrete floor and/or roof units
U.S.A. and manufactured by Arabian Vermiculite Industries
(including slab, pan joist, hollow-core or pre-cast plant or
in Dammam, Saudi Arabia.
TEE units) prior to application of the products listed in item 2.
5. Avikote AV650 and Avikote AV800 are manufactured by
4. As a bonding agent for use over any approved substrate
Arabian Vermiculite Industries.
prior to application of Sonotex range of products
5. As a surface sealer (where specified) over any of the above
products. Coverage rate requirements will vary based on
project requirements. A surface sealer shall be installed in
one or more coats in such a manner that the sealer does
not substrate the fire protection product. The fire protection
product should be substantially dry prior to sealer application.
Application
Graco Encapsulator II or airless spray equivalent, roller or brush.
Pressure : 2500 – 2700 PSI
Hose Length : 100’
Hose diameter : ¼”
Tip size : 0.015 – 0.25 (orifice size)
Fan size : 12”
Coverage : Firebond – 500 sq. ft./gal.
Clean up : Tools and drippings should be cleaned
with soapy water
www.avi-sa.com | [email protected]
Arabian Vermiculite Industies P.O. Box 7137, Dammam 31462, Saudi Arabia Tel: +966 13 847 1450 Fax: +966 13 847 1575