Inverter Chiller and Heat Pumps EWA (Y) T CZ Series
Inverter Chiller and Heat Pumps EWA (Y) T CZ Series
The new R-32 Small Inverter Chiller provides This new series stands out for being able to provide
the lowest direct and indirect CO2 emissions levels. the best efficiency levels in the market, both in
That makes it an environmentally friendly series, cooling and heating mode, allowing substantial
also thanks to the use of R-32, which is known for savings on energy bills.
being a low GWP and sustainable refrigerant.
Daikin can count on the highest number of R-32 The R-32 Small Inverter Chiller series has been
installations around the world. That not only means designed to meet the needs of the widest possible
being the most experienced, but also means being range of applications, from process cooling
the most knowledgeable and reliable brand applications, to residential, commercial and data
producing R-32 technology. centers applications. All that to provide customers
with an extremely flexible solution to their needs.
The management of multiple units in parallel as well Complexity has been reduced by moving from
as the advanced control logics for optimizing the hardware to software tools. Thanks to a newly
heating and cooling production and fulfil domestic designed Configuration App, it possible to let the units
hot water needs provide this new Series a with a full of this Series communicate with any external BMS.
set of invaluable features.
The new R-32 Small Inverter Chiller comes in three Daikin customers, other than benefitting from
different layouts, all providing a very compact the quality standards associated with the brand, they can
footprint despite the cooling/heating capacity they benefit from Daikin’s widespread network of installers
can deliver. That makes the series a great solution for and after sales support teams around the world.
projects dealing with space issues.
ʯ Capacity range from 16 to 90 kW
Working conditions
Heating guaranteed all year round and hot water production up to 60°C and cooling
from -20°C up to 52°C in order to respond to all countries need intallations.
The most advanced technology with highest efficiency and quality levels.
Unrivaled and proven reliability thanks to testing of chillers and components in different locations
even at extreme working conditions.
Plant management
& connectivity
Master/Slave or Modbus RTU are standard
to ensure a perfect plant Connectivity.
Daikin License Manager When ordering the Connectivity Kit, you will receive a
Connectivity card. The card will report a unique Activation
the mobile App to enable BMS communication ID (QR code) identifying the license for a specific SIC unit
protocols on the new Small Inverter Chiller controller. The SIC controller has a sticker that must be put
on the Connectivity card in order to use it with the app.
Frame the Connectivity Download the license to Your can now connect your
card with your camera the SIC unit controller Chiller to your BMS
Heat pump EWYT-CZ series
Heating & cooling EWYT-CZN/CZP/CZH 016 021 025 032 40 - MONO 40 - DUAL 050 064 090
Cooling capacity Nom. 15.9 (1)/16.1 20.9 (1)/21.1 25.6 (1)/25.9 32.4 (1)/32.7 39.6 (1)/39.9 41.4 (1)/41.7 50.8 (1)/51.1 64 (1)/64.4 88.3 (1)/88.8
kW
(2)/16.2 (3) (2)/21.2 (3) (2)/25.9 (3) (2)/32.8 (3) (2)/40.1 (3) (2)/41.8 (3) (2)/51.3 (3) (2)/64.5 (3) (2)/88.9 (3)
Max. 18.3 (1)/18.6 25 (1)/25.3 29.3 (1)/29.6 38.6 (1)/38.9 45.2 (1)/45.6 49.6 (1)/50 58.2 (1)/ 72.7 (1)/ 73.3 98.3 (1)/ 98.8
kW
(2)/18.7 (3) (2)/25.4 (3) (2)/29.6 (3) (2)/39.1 (3) (2)/45.7 (3) (2)/50.1 (3) 58.6(2)/58.7 (3) (2)/73.4 (3) (2)/98.9 (3)
Heating capacity Nom. 15.9 (1)/15.62 20.2 (1)/19.93 24.8 (1)/24.6 32.4 (1)/32.08 39.4 (1)/39 40.3 (1)/40.01 49.8 (1)/49.49 61.9 (1)/61.43 85.8 (1)/85.33
kW
(2)/15.5 (3) (2)/19.8 (3) (2)/24.5 (3) (2)/32 (3) (2)/38.9 (3) (2)/39.9 (3) (2)/49.4 (3) (2)/61.3 (3) (2)/85.2 (3)
Max. 18.3 (1)/18 24.3 (1)/24 28.7 (1)/28.4 36.5 (1)/36.2 44.7 (1)/44.3 48.7 (1)/48.4 57.3 (1)/ 58.9 69.2 (1)/68.7 94.7 (1)/ 94.1
kW
(2)/18 (3) (2)/23.9 (3) (2)/28.3 (3) (2)/36.1 (3) (2)/44.2 (3) (2)/48.3 (3) (2)/56.7 (3) (2)/68.6 (3) (2)/94 (3)
Power input Cooling Nom. 5.5 (1)/5.45 6.6 (1)/6.56 8.5 (1)/8.48 10.3 (1)/10.3 13.4 (1)/13.3 13.2 (1)/13.2 17 (1)/16.9 21.8 (1)/21.9 31 (1)/31.1
kW
(2)/5.6 (3) (2)/6.7 (3) (2)/8.7 (3) (2)/10.4 (3) (2)/13.5 (3) (2)/13.3 (3) (2)/17 (3) (2)/22 (3) (2)/31.2 (3)
Heating Nom. 4.7 (1)/4.63 5.8 (1)/5.81 7.5 (1)/7.42 9.4 (1)/9.32 11.8 (1)/11.7 11.9 (1)/11.8 15.4 (1)/15.3 19.1 (1)/19.2 27.2 (1)/27.3
kW
(2)/4.8 (3) (2)/6 (3) (2)/7.6 (3) (2)/9.5 (3) (2)/11.9 (3) (2)/12 (3) (2)/15.4 (3) (2)/19.3 (3) (2)/27.4 (3)
Capacity control Method Inverter controlled
Minimum capacity % 18 14 12 19 15 14 12 15 14
EER 2.9 (1)/2.96 3.16 (1)/3.22 3 (1)/3.05 (2)/2.98 3.13 (1)/3.18 2.95 (1)/3 (2)/2.97 3.12 (1)/3.17 2.98 (1)/3.03 2.93 (1)/2.95 2.84 (1)/2.85
(2)/2.89 (3) (2)/3.15 (3) (3) (2)/3.14 (3) (3) (2)/3.15 (3) (2)/3.02 (3) (2)/2.93 (3) (2)/2.85 (3)
COP 3.41 (1)/3.37 3.46 (1)/3.43 3.33 (1)/3.31 3.45 (1)/3.44 3.33 (1)/3.33 3.38 (1)/3.38 3.24 (1)/3.23 3.23 (1)/3.2 3.16 (1)/3.13
(2)/3.24 (3) (2)/3.31 (3) (2)/3.22 (3) (2)/3.37 (3) (2)/3.28 (3) (2)/3.33 (3) (2)/3.2 (3) (2)/3.17 (3) (2)/3.12 (3)
SEER 5 (1)/5.41 (2)/5.32 5.06 (1)/5.41 5.21 (1)/5.7 5.09 (1)/5.36 5.41 (1)/5.76 5.33 (1)/5.48 5.21 (1)/5.34 5.03 (1)/5.18
5 (1)/5.3 (2)/5.2 (3)
(3) (2)/5.34 (3) (2)/5.67 (3) (2)/5.34 (3) (2)/5.76 (3) (2)/5.4 (3) (2)/5.27 (3) (2)/5.12 (3)
ηs,c 197 (1)/209 197 (1)/213 200 (1)/213 205 (1)/225 201 (1)/211 213 (1)/228 210 (1)/216 205 (1)/211 198 (1)/204
%
(2)/205 (3) (2)/210 (3) (2)/211 (3) (2)/224 (3) (2)/210 (3) (2)/227 (3) (2)/213 (3) (2)/208 (3) (2)/202 (3)
Space heating Average climate General ηs (Seasonal space 153 (1)/158 157 (1)/165 160 (1)/165 159 (1)/164 160 (1)/164 158 (1)/165 157 (1)/162 156 (1)/157 157 (1)/159
%
water outlet heating efficiency) (2)/152 (3) (2)/159 (3) (2)/160 (3) (2)/161 (3) (2)/162 (3) (2)/163 (3) (2)/161 (3) (2)/155 (3) (2)/157 (3)
35°C SCOP Low Temp. 3.89 (1)/4.03 4 (1)/4.19 (2)/4.06 4.07 (1)/4.19 4.06 (1)/4.18 4.07 (1)/4.18 4.02 (1)/4.19 4 (1)/4.12 (2)/4.09 3.98 (1)/4.01
4 (1)/4.04 (2)/4 (3)
(2)/3.88 (3) (3) (2)/4.08 (3) (2)/4.11 (3) (2)/4.13 (3) (2)/4.14 (3) (3) (2)/3.94 (3)
Seasonal space
A++ A++ A++ A++ A++ A++ A++ A++ A++
heating eff. Class
Dimensions Unit Height mm 1,878
Width mm 1,552 1,752 2,306 2,906 3,506
Depth mm 802 814
Weight Unit kg 227 (1)/261 (2) (3) 252 (1)/286 (2) (3) 350 (1)/393 (2) (3) 349 (1)/392 (2)(3) 494 (1)/546 (2) (3) 588 (1)/644 (2) (3) 693 (1)/749 (2) (3)
Water heat Type Brazed plate HE
exchanger Water flow rate Cooling Nom. l/s 0.8 1 1.2 1.6 1.9 2 2.4 3.1 4.2
Heating Nom. l/s 0.8 1 1.2 1.6 1.9 2 2.4 3.1 4.2
Water pressure drop Cooling Total kPa 19.8 11.3 16.3 19.2 27.6 9.91 14.3 21.7 20.1
Water volume l 1 2 5 8
Air heat exchanger Type Al Fins&Cu Tubes
Compressor Type Hermetically sealed scroll compressor
Quantity 1 2
Fan Type Axial
Quantity 1 2 3 4
Air flow rate Cooling Nom. l/s 3227 3122 3524 5080 6701 5444 7048 8967 13402
Heating Nom. l/s
Sound power level Cooling Nom. dBA 76 78 79 80 81 83 85
Operation range Air side Cooling Min.~Max. °CDB -20~52
Heating Min.~Max. °CDB -20~35
Water side Cooling Min.~Max. °CDB -15~25
Heating Min.~Max. °CDB 20~60
Refrigerant Type R32
Circuits Quantity 1 2
Control Electronic expansion valve
GWP 675
Refrigerant charge Total kg 3 5.5 5.5 7 8 12 12 13 16
kgCO2eq 2025 3713 3713 4725 5400 8100 8100 8775 10800
Water circuit Piping connections
inch 1-1/4“ (female) 2“ (female)
diameter
Unit Running current Max A 17 (1)/21 (2)/21 (3) 21 (1)/25 (2)/25 (3) 23 (1)/27 (2)/27(3) 34 (1)/38 (2)/39 (3) 38 (1)/42 (2)/43 (3) 41 (1)/45 (2)/46 (3) 46 (1)/50 (2)/51 (3) 61 (1)/66 (2)/68 (3) 83 (1)/88 (2)/90 (3)
Power supply Phase/Frequency/
Hz/V 3N~/50/400
Voltage
(1) EWYT-CZN: version without pump. (2) EWYT-CZP: version with pump low lift. (3) EWYT-CZH: version with pump high lift.
All the cooling performances (cooling capacity, unit power input in cooling and EER) are based on the following conditions: 12,0/7,0°C; ambient 35,0°C, unit at full load operation;
operating fluid: water; fouling factor = 0. EN14511:2018
All the heating performances (heating capacity, unit power input in heating and COP) are based on the following conditions: 40,0/45,0°C; ambient 7,0°C, unit at full load operation;
operating fluid: water; fouling factor = 0. EN14511:2018
SEER is calculated in accordance with the regulation No. 2281/2016 and standard EN14825 for information only, unless the unit is a “cooling-only” type.
The values of Low Temperature SCOP and ηs are calculated in accordance with the Ecodesign regulation No. 813/2013 and the standard EN 14825-2018.
Performances according to CSS software 10.29
Daikin Europe N.V. Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Publisher)
FSC
Performance programme for Liquid Chilling Packages and
Hydronic Heat Pumps, Fan Coil Units and Variable Refrigerant
Flow systems. Check ongoing validity of certificate:
www.eurovent-certification.com
ECPEN21-42006/21
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.