Registration No : 240625022
Patient Name : MRS. PRACHI KAMBLI Registered On : 24-Jun-2025 11:06 AM
Age/Gender : 60 Years / Female Sample Collected On : 24-Jun-2025 11:14 AM
Referral : VISIT Sample Reported On : 24-Jun-2025 04:52 PM
Source
Center Name
:
: The Lab Plus
Sample ID
*240625022*
Complete Blood Count
Parameter Value(s) Unit Ref Range
COMPLETE BLOOD COUNT
Blood Haemoglobin Levels 11.3 g/dL 12 -15
R.B.C. Count 3.69 mil/µL 3.8 - 4.8
Packed Cell Volume (HCT) 33.3 % 36-46
Mean Cell Volume(MCV) 90.2 fl 83-101
Mean Cell Hemoglobin( MCH) 30.6 pg 27-33
Mean Cell Hb Conc(MCHC) 33.9 % 32 -38
RDW (CV) 18.1 % 11.6 - 14.6
Platelet Count 297000 /uL 150000-410000
Mean Platelet Volume (MPV) 9.4 fl 7.5 - 12.0
Platelet Distribution Width (PDW) 16.4 % 15 - 17
Total W.B.C. Count (Leukocytes 6690 / cumm 4000-11000
count)
DIFFERENTIAL COUNT
Neutrophils 75 % 50-70
Lymphocytes 13 % 15 - 45
Eosinophils 02 % 0-6
Monocytes 10 % 2.0 - 10.0
Basophils 00 %
ABSOLUTE COUNT
Absolute Neutrophils Count 5018 / cumm 2000-7000
Absolute Lymphocytes Count 870 / cumm 1000-3000
Absolute Monocytes Count 669 / cumm 200-1000
Absolute Eosinophils Count, AEC 134 / cumm 20-500
PERIPHERAL SMEAR-MICROSCOPIC EXAMINATION
RBC Morphology Anisocytosis
WBC Morphology Neutrophilia
Platelet on smear Adequate on smear
Instrument: Sample processed on Fully automated 7 PART Hematology analyzer,
Mindray BC- 760 with Optical PLT-H.
Dr.Ashish Bhosle
Page 1 of 4
M.D.Pathologist
Registration No : 240625022
Patient Name : MRS. PRACHI KAMBLI Registered On : 24-Jun-2025 11:06 AM
Age/Gender : 60 Years / Female Sample Collected On : 24-Jun-2025 11:14 AM
Referral : VISIT Sample Reported On : 24-Jun-2025 04:52 PM
Source
Center Name
:
: The Lab Plus
Sample ID
*240625022*
Complete Blood Count
Parameter Value(s) Unit Ref Range
Interpretation
BLOOD COUNTS-
• RBC AND PLATELET INDICES-The cell morphology is well preserved for 24hrs. However after 24-48 hrs a progressive
increase in MCV and HCT is observed leading to a decrease in MCHC. A direct smear is recommended for an accurate
differential count and for examination of RBC morphology.
• WBC DIFFERENTIAL COUNT - NLRThe optimal threshold of 3.3 for NLR showed a prognostic possibility of clinical symptoms
to change from mild to severe in COVID positive patients.
• When age = 49.5 years old and NLR = 3.3, 46.1% COVID-19 patients with mild disease might become severe.
• By contrast, when age < 49.5 years old and NLR < 3.3, COVID-19 patients tend to show mild disease.
Note:
1.As per the recommendation of International council for Standardization in Hematology, the differential leucocyte counts
are additionally being reported as absolute numbers of each cell in per unit volume of blood
2.Test conducted on EDTA whole blood
Prothrombin Time
Parameter Value(s) Unit Ref Range
Prothrombin Time 15.0 Sec 13-16
CONTROL VALUE(MNPT) 13.2 Sec
ISI VALUE 1.1
INR VALUE 1.15 0.5-1.2
Ratio 1.1
Method Performed on coagulatiol analyzer ADG C-102
______________________________________________________________________________________________________
Interpretation :
Prothombin time (PT) is a blood test that measures how long it takes blood to clot. A prothombin time test can be used to
check for bleeding problems. PT is also used to check whether medicine to prevent blood clots is working.
______________________________________________________________________________________________________
Comment : Please correlate with clinical condition
Technology : Coagulation
Notes : Clinical diagnosis should not be made on the findings of a single test result, but should integrate both
clinical and laboratory data.
______________________________________________________________________________________________________
Dr.Ashish Bhosle
Page 2 of 4
M.D.Pathologist
Registration No : 240625022
Patient Name : MRS. PRACHI KAMBLI Registered On : 24-Jun-2025 11:06 AM
Age/Gender : 60 Years / Female Sample Collected On : 24-Jun-2025 11:14 AM
Referral : VISIT Sample Reported On : 24-Jun-2025 02:14 PM
Source
Center Name
:
: The Lab Plus
Sample ID
*240625022*
Blood Sugar - Fasting
Parameter Value(s) Unit Ref Range
Blood Sugar Fasting (F) 127.96 mg/dL 70 - 110
Method: GOD/POD Photomethry
Instrument Sample processed on Fully automated Biochemistry Analyzer , Mindray
BS- 240 pro & CE approved.
Blood Sugar- Post Prandial
Parameter Value(s) Unit Ref Range
Blood Sugar Level (PP) 247.32 mg/dL 70-140
Method: GOD/POD Photomethry
Instrument Sample processed on Fully automated Biochemistry Analyzer, Mindray
BS- 240 pro & CE approved.
Dr.Ashish Bhosle
Page 3 of 4
M.D.Pathologist
Registration No : 240625022
Patient Name : MRS. PRACHI KAMBLI Registered On : 24-Jun-2025 11:06 AM
Age/Gender : 60 Years / Female Sample Collected On : 24-Jun-2025 11:14 AM
Referral : VISIT Sample Reported On : 24-Jun-2025 02:16 PM
Source
Center Name
:
: The Lab Plus
Sample ID
*240625022*
Renal Function Test
Parameter Value(s) Unit Ref Range
RENAL FUNCTION TEST
Total Proteins 6.0 gms/dl 6.0 - 8.2
Method : Biuret
Serum Albumin 3.28 gms/dl 3.2 - 6.0
Method : BCG
Serum Urea 15.83 mg/dL 15 - 45
Method: Urease kinetic
Blood Urea Nitrogen 7 mg/dL 6 - 24
Serum Creatinine 0.64 mg/dL 0.5 - 1.0
Method: Enzymatic UV
BUN/Creatinine Ratio 11 mg/dL 6 - 22
Serum Uric Acid 3.36 mg/dL 2.4 - 5.7
Method:Uricase - PAP
Calcium 9.19 mg/dL 8.5 - 10.1
Method: Arsenazo III
Serum Phosphorous 3.4 mg/dL 2.6 - 4.5
Method: Phosphomolybdate UV
Instrument Sample processed on Fully automated Biochemistry Analyzer , Mindray
BS- 240 pro & CE approved.
Interpretation :
Renal function tests (RFT) are performed for evaluation of kidney function. The blood urea nitrogen or BUN test is primarily
used, along with the creatinine test, to evaluate kidney function in a wide range of circumstances, to help diagnose kidney
disease, and to monitor people with acute or chronic kidney dysfunction or failure. 1. Blood Urea Nitrogen (BUN) - Urea is a
waste product formed in the liver when protein is metabolized. Urea is released by the liver into the blood and is carried to
the kidneys, where it is filtered out of the blood and released into the urine. 2. Creatinine - Creatinine is a waste product
produced by muscles from the breakdown of a compound called creatine. Almost all creatinine is filtered from the blood by
the kidneys and released into the urine, so blood levels are usually a good indicator of how well the kidneys are working. 3.
Uric acid - The uric acid blood test is used to detect high levels of this compound in the blood in order to help diagnose
recurrent kidney stones and gout. The test is also used to monitor uric acid levels in people undergoing chemotherapy or
radiation treatment for cancer.
--------------------------------------------------------------------------------------- END OF REPORT------------------------------------------------------------------------------------------
This sample is processed at THE LAB PLUS , Dignostics & Health Care,NABL Accredited
Dr.Ashish Bhosle
Page 4 of 4
M.D.Pathologist