2025-05-16 09-50-33 Sabia Gabriel 10052000 Os

The document is a treatment printout for a patient named Gabriel Sabia, who underwent a TransPRK procedure for Compound Myopic Astigmatism on May 16, 2025. The treatment involved specific laser settings and parameters, including an ablation depth of 117.73 µm and a total ablation volume of 5315 nl. Additional system data and environmental conditions during the procedure are also provided.

Uploaded by

faturamentohosl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views1 page

2025-05-16 09-50-33 Sabia Gabriel 10052000 Os

The document is a treatment printout for a patient named Gabriel Sabia, who underwent a TransPRK procedure for Compound Myopic Astigmatism on May 16, 2025. The treatment involved specific laser settings and parameters, including an ablation depth of 117.73 µm and a total ablation volume of 5315 nl. Additional system data and environmental conditions during the procedure are also provided.

Uploaded by

faturamentohosl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Laser serial number R432 (1050Hz)

Software version 6.1.2117.900


User HODF
Date yyyy-mm-dd 2025-05-16
Time 09:50:33 TREATMENT PRINTOUT -ORK-

Patient
Patient ID Firstname Lastname Date of birth Age Gender
OS 10052000 GABRIEL SABIA
yyyy-mm-dd
25 male
2000-05-10
Planning Data Treatment Data
Type of treatment AF Optical zone (OZ) 7,30 mm
Treatment method TransPRK Transition zone (TZ) 1,21 mm

Type of refraction Compound Myopic Astigmatism


Ablation zone (TAZ) 8,51 mm

K1 42,43 D @ 169 ° Ablation depth MAX 118 µm


K-Reading Pre
K2 44,68 D @ 79 ° Ablation depth CENTRAL 117,73 µm
Ablation depth MIN 66,3 µm
Refraction @ VD = 12,0 mm ; RZ = 4,00 mm
Sphere Cylinder Axis Ablation volume 5315 nl
Manifest -2,00 D -1,50 D x 170 °
Target 0,00 D 0,00 D x 170 °
Lasersetting -2,00 D -1,50 D x 170 °

Treatment
Ablation Time 40 s Treatment Time 43 s
Ablation progress 100 % Eye - tracking status On: 100 % Off: 0 %
Temperature Begin/End 23,0 °C / 23,0 °C Pupil offset R:0,00 mm Angle:0 °
Humidity Begin/End 42 % / 42 % DCC MIN -0,70 °
SCC n.a. DCC MAX 0,10 °
Eye picture I Fixation I

T N T N

Systemdata S S
Fluence
High 645 nm Laser energy
High 4,48 mJ
Low 544 nm Low 4,17 mJ
High voltage 727 V
Temp/Humidity last fluence 19,7 °C 54,0 %
Time since last fluence test 2 h 8 min

Comment
CAM

AMARIS