0% found this document useful (0 votes)
23 views5 pages

Schneider Electric - TeSys-Deca-contactors - LC1D38N7

The document provides a datasheet for the TeSys D contactor (LC1D38N7), detailing its specifications, including operational voltage, current ratings, and motor power capabilities. It highlights the product's compliance with various standards and certifications, as well as its environmental impact and sustainability initiatives. Additionally, it outlines installation requirements, dimensions, and warranty information.

Uploaded by

albarrifateh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views5 pages

Schneider Electric - TeSys-Deca-contactors - LC1D38N7

The document provides a datasheet for the TeSys D contactor (LC1D38N7), detailing its specifications, including operational voltage, current ratings, and motor power capabilities. It highlights the product's compliance with various standards and certifications, as well as its environmental impact and sustainability initiatives. Additionally, it outlines installation requirements, dimensions, and warranty information.

Uploaded by

albarrifateh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Product datasheet

Specifications

TeSys D contactor - 3P(3 NO) -


AC-3 - <= 440 V 38 A - 415 V AC
50/60 Hz coil
LC1D38N7

Main
Range TeSys
TeSys Deca

Range of product TeSys Deca

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Contactor

Device short name LC1D

Contactor application Resistive load


Motor control

Utilisation category AC-4


AC-1
AC-3
AC-3e

Poles description 3P

[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz


Power circuit: <= 300 V DC

[Ie] rated operational current 50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
38 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

[Uc] control circuit voltage 415 V AC 50/60 Hz

Complementary
Motor power kW 18.5 kW at 500 V AC 50/60 Hz (AC-3)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3)
7.5 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
9 kW at 220...230 V AC 50/60 Hz (AC-3)
18.5 kW at 415...440 V AC 50/60 Hz (AC-3)
18.5 kW at 500 V AC 50/60 Hz (AC-3e)
18.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
9 kW at 220...230 V AC 50/60 Hz (AC-3e)
18.5 kW at 415...440 V AC 50/60 Hz (AC-3e)

Motor power hp 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors


10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
5 hp at 240 V AC 50/60 Hz for 1 phase motors
20 hp at 480 V AC 50/60 Hz for 3 phases motors
25 hp at 600 V AC 50/60 Hz for 3 phases motors

Compatibility code LC1D

Pole contact composition 3 NO

Protective cover With

[Ith] conventional free air thermal 10 A (at 60 °C) for signalling circuit
current 50 A (at 60 °C) for power circuit

Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
550 A at 440 V for power circuit conforming to IEC 60947

Excluding VAT, FCA Jabal Ali & are subject to change – check with your local distributor.

4 Apr 2025 1
Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand 60 A 40 °C - 10 min for power circuit


current 430 A 40 °C - 1 s for power circuit
150 A 40 °C - 1 min for power circuit
310 A 40 °C - 10 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1


63 A gG at <= 690 V coordination type 1 for power circuit
63 A gG at <= 690 V coordination type 2 for power circuit

Average impedance 2 mOhm - Ith 50 A 50 Hz for power circuit

Power dissipation per pole 5 W AC-1


3 W AC-3
3 W AC-3e

[Ui] rated insulation voltage Power circuit: 600 V CSA certified


Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1

Overvoltage category III

pollution degree 3

[Uimp] rated impulse withstand 6 kV conforming to IEC 60947


voltage
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO
13849-1

Mechanical durability 15 Mcycles

Electrical durability 1.4 Mcycles 50 A AC-1 at Ue <= 440 V


1.4 Mcycles 38 A AC-3 at Ue <= 440 V
1.4 Mcycles 38 A AC-3e at Ue <= 440 V

Control circuit type AC at 50/60 Hz

Coil technology Without built-in suppressor module

Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz


0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)


70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)


7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W at 50/60 Hz

Operating time 4...19 ms opening


12...22 ms closing

Maximum operating rate 3600 cyc/h at 60 °C

2 4 Apr 2025
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable
end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without
cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 1 1…10 mm² - cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 1 1.5…10 mm² - cable stiffness: solid without
cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: solid without
cable end

Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Auxiliary contact composition 1 NO + 1 NC

Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1


type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz

Minimum switching voltage 17 V for signalling circuit

Minimum switching current 5 mA for signalling circuit

Insulation resistance > 10 MOhm for signalling circuit

Non-overlap time 1.5 ms on de-energisation between NC and NO contact


1.5 ms on energisation between NC and NO contact

Mounting support Rail


Plate

Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1

Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme

IP degree of protection IP20 front face conforming to IEC 60529

Protective treatment TH conforming to IEC 60068-2-30

Climatic withstand conforming to IACS E10 exposure to damp heat


conforming to IEC 60947-1 Annex Q category D exposure to damp heat

4 Apr 2025 3
Permissible ambient air -40…60 °C
temperature around the device 60…70 °C with derating

Operating altitude 0...3000 m

Fire resistance 850 °C conforming to IEC 60695-2-1

Flame retardance V1 conforming to UL 94

Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)


Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)

Height 85 mm

Width 45 mm

Depth 92 mm

Net weight 0.38 kg

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 4.9 cm

Package 1 Width 11.1 cm

Package 1 Length 8.9 cm

Package 1 Weight 414.0 g

Contractual warranty
Warranty 18 months

4 4 Apr 2025
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Carbon footprint (kg.eq.CO2 per CR, Total Life cycle) 174

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard Yes

Packaging without single use plastic Yes

EU RoHS Directive Compliant

REACh Regulation REACh Declaration

PVC free Yes

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

Take-back No

The product must be disposed on European Union


WEEE markets following specific waste collection and never end
up in rubbish bins