FOREWORD
Delhi Schedule of Rates published by Central Public Works Department from time to time is
a comprehensive and useful technical document for execution of civil works. In addition to
CPWD, this Schedule of Rates is used by many Departments, Institutions, Public Sector
Undertakings, Architects and Builders.
Delhi Schedule of Rates was first published in the year 1931, followed by a number of
revisions/publications from time to time in order to bring it in line with the prevailing
materials, technologies, market rates and implementation of GST. It was revised in 1977,
1981, 1985, 1989, 1993, 1997, 2002, 2007,
2010 (Reprint), 2012, 2013, 2014, 2016 and 2019.
Last edition of Delhi Schedule of Rates was published in the year 2019. Revision of this
DSR has become necessary due to change in wages of labour and prices of materials,
adoption of new construction technologies & materials. These components have been
incorporated in the DSR 2021 by revising DSR 2019.
I wish to place on record the technical input and effective coordination on the part of Shri
D.C.Goel ADG (Tech.), Shri Vinayak Rai CE (CSQ) (Civil) and the sincere efforts put in by
Shri Divakar Agrawal SE (TAS), Shri S.N.Jaiswal EE(TAS), Shri Mukesh Varma Chief
Estimator, Shri Naveenkumar P JE (TAS), Shri Chalapaka Ramaraju JE (TAS) and team
of officers in CSQ unit in preparation and finalizing the DSR 2021 in a short time.
I am sure that Delhi Schedule of Rates 2021 will be useful to all the engineers and architects
in Building Construction Industry in general and CPWD in particular.
Place: New Delhi (Vinit Kumar Jayaswal)
Date: July 12, 2021 Director General
ENT OF INDIA
WORKS DEPARTMENT
DULE OF RATES
ol. 2)
021
dsUnzh; yksd fuekZ.k foHkkxfuekZ.k Hkou] ubZ fnYyh 110011 Central Public Works Department Nirman Bhawan, New Delh
ORD
ublic Works Department from time to time is
for execution of civil works. In addition to
Departments, Institutions, Public Sector
9.
lished in the year 2019. Revision of this
ages of labour and prices of materials,
terials. These components have been
2019.
effective coordination on the part of Shri
SQ) (Civil) and the sincere efforts put in by
al EE(TAS), Shri Mukesh Varma Chief
hri Chalapaka Ramaraju JE (TAS) and team
ng the DSR 2021 in a short time.
PREFACE
1. Delhi Schedule of Rates popularly called as DSR is updated as 2021 edition and includes existing
items of DSR 2019 with (a) deletion of few items which are not in use now, (b) merger of similar items, and (c)
addition of new items in line with emerging trends in construction Industry.
2. DSR 2021 is based on the prevailing market rates of materials in Delhi as on or just before 01.04.2021.
The labour rates adopted are as per minimum wages applicable with effect from 01.04.2021 issued by Govt. of
Delhi/ Govt. of India, whichever is higher.
3. The cost index for DSR 2021 is 105 with reference to CPWD Delhi Plinth Area Rates 2020, having base
100 as on 01.04.2020 and cost index as on 01.04.2020 is 101 over CPWD Delhi Plinth Area Rates 2019 having
base 100.
4. The technical sanctioning authority may decide rates of non-schedule items judiciously based on
market rates without adding cost index.
5. This DSR 2021 shall be read along with CPWD specifications 2019 Vol.-I & II with up-to-date correction
slips.
6. The salient Features of DSR 2021are as follows:
6.1 DSR 2021 is bilingual and in two volumes each, however, in case of any discrepancy between English and
Hindi versions, the English version shall prevail.
6.1.1 The rates of basic materials incorporated in this DSR 2021 are considered for the materials available in
the market conforming to BIS Standards/ CPWD Specifications.
6.1.2 The effect of GST on works contract has been incorporated in all the items.
6.2 Salient Modifications and Changes in Sub Heads:
6.2.1 Concrete Work: Many new items are included and amendments in existing items have been made with
reference to IS 386:2016 based on Recycled Concrete Aggregate (RCA) & Recycled Aggregate (RA). Some of
the items with excess/ less cement than specified in the items without limit are deleted and modified items with
excess cement upto 10% of the minimum specified cement content in design mix are incorporated.
6.2.2 Reinforced Cement Concrete: Many new items are included and amendments
in existing items have been made with reference to IS 386:2016 based on Recycled Concrete Aggregate (RCA) &
Recycled Aggregate (RA). Some of the items with excess/less cement than specified in the items without limit are
deleted and modified items with excess cement upto 10% of the minimum specified cement content in design mix
are incorporated.
6.2.3 Cladding Work: Amendment is made in item no. 8.2.2 and new item is made as item no. 8.2.3 based on
different colour of granite stones.
6.2.4 Wood & PVC Work: Items Nos. 9.166 to 9.174 for modular kitchen items are added.
6.2.5 Flooring: The items Nos. 11.41A.1.1 to 11.41A.3.5 for vitrified tiles of different sizes are added. The
amendment has been made in item no. 11.56.1 and new item is incorporated as item no. 11.53.2 based on different
colour of granite stones.
6.2.6 Roofing: The items Nos. 12.64, 12.65 & 12.66 for Aluminium profile sheets are added.
6.2.7 Finishing: The item No. 13.116 for high gloss / Matt finish melamine clear polish is added.
6.2.8 Repairs to Building: The amendment in existing items nos. 13.93 & 13.94 are made.
6.2.9 Road Work: The amendment has been made in item no. 16.87.1 and new item is incorporated as item no.
16.87.2 based on different colour of granite stones.
6.2.10 Water Supply: The items Nos. 18.85A, 18.86A, 18.87A, 18.88A, 18.89A,
18.90A, 18.92A, 18.93A, 18.95A, 18.96A, 18.97A, 18.99A, 18.100A,
18.101A, 18.102A, 18.103, 18.104 & 18.105 for stainless steel pipes and fittings of Grade 316L are added. The
amendments are made in nomenclature of item no.
18.8.1 to 18.9.10 as per IS 15778:2007. The amendments are made in nomenclature of item nos. 18.70.11 &
18.70.12 with respect to specification and basic rates.
6.2.11 New Technologies and Materials: With a view to give boost to make in India initiative of the
Government, new technology items have been added in New Technologies and Materials sub head. These new
items are included for a period of two years and then performance shall be reviewed. Following are the items added
under this sub head.
1. EPS (Cellular plastic material) block (item no. 26.82)
2. Stamping finish to freshly laid plain/reinforced cement concrete (item no. 26.83).
3. Uni-axial and Bi-Axial woven Polyester Geogrids (item no. 26.84 & 26.85).
4. WPC boards in paneling, Cabinets, Doors, Windows etc. (items no. 26.86 to 26.91).
1. EPS (Cellular plastic material) block (item no. 26.82)
2. Stamping finish to freshly laid plain/reinforced cement concrete (item no. 26.83).
3. Uni-axial and Bi-Axial woven Polyester Geogrids (item no. 26.84 & 26.85).
4. WPC boards in paneling, Cabinets, Doors, Windows etc. (items no. 26.86 to 26.91).
5. Extruded hollow clay/terracotta ventilated rain screen tiles (items no. 26.92 & 26.93).
6. Amendments in existing items nos. 26.1 & 26.3 for bamboowood, item no.
26.22 for densified calcium silicate false ceiling tiles, item no. 26.42, 26.43 &
26.45 for light gauge steel frame work, item no. 26.48 for aluminium formwork for monolithic construction on
RCC members are made.
7. Other corrections/modifications of minor nature such as typographical error, deletion of misleading content
etc. have been undertaken.
8. Wholehearted commitment and considerable efforts has gone into the preparation of this edition of Delhi
Schedule of Rates. I convey my deep appreciation and sincere thanks to Shri Vinayk Rai CE(CSQ), Shri Divakar
Agrawal SE (TAS), Shri S.N. Jaiswal EE (TAS), Shri. Mueksh Varma Chief Estimator (TAS), Shri Akhileshwar
Sah Chief Eastimator (TAS), Shri. D.S.Adikari AE, Ms. Anshu Shukla AE(TAS), Shri Chalapaka Ramaraju
JE(TAS), Shri Naveenkumar P JE(TAS), Shri A.K.Jha AD (OL) and his team for translation of DSR- 2021 in
Hindi and other officers and staff of CSQ unit whose names are not mentioned here for the sake of brevity for their
sincere efforts made in the preparation of this document in such a short time. Various individuals, Committees and
field units, have immensely contributed with substantial inputs; the CSQ unit is indebted for their support.
9. I convey my gratitude to field offices at Delhi who rose to the occasion and provided sufficient data base of
market rates to CSQ office and thus enabled them to come out with this edition of DSR in a short time.
10. Although due care has been taken in bringing out DSR-2021, there is possibility that some errors are still
there inadvertently. Error or omission may be brought to the notice of Superintending Engineer (TAS), CPWD,
Room No. 418A, A-wing, Nirman Bhawan, New Delhi -110011 (Tele fax. 011-23062339).
Suggestions for improvement are welcome.
Dharmesh Chandra Goel ADG(Tech) CPWD
dsUnzh; yksd fuekZ.k foHkkx fuekZ.k Hkou] ubZ fnYyh 110011 Central Public Works Department Nirman Bhawan, New Delhi-
E
pdated as 2021 edition and includes existing
ot in use now, (b) merger of similar items, and (c)
ction Industry.
materials in Delhi as on or just before 01.04.2021.
e with effect from 01.04.2021 issued by Govt. of
0.2 LABOUR 7
0.3 MATERIALS 9
1 Carriage of Materials 79
2 Earth Work 89
3 Mortar 99
11 Flooring 229
12 Roofing 247
13 Finishing 273
19 Drainage 431
75
79
89
99
103
115
135
145
153
165
219
229
247
273
291
307
317
345
373
431
447
455
465
477
485
491
501
547
591
ATES
BASIC RATES (SH: 13.0 FINISHING)
Code No. Description Unit
0803 Acrylic emulsion, having VOC content less than 50 grams/ litre litre
0804 Premium plastic acrylic emulsion of interior grade, having VOC content less
than 50 grams/ litre litre
0806 Ready mixed pink or grey primer on wood work (hard and soft wood) having
VOC content less than 50 grams/ litre litre
0808 Water thinnable cement primer for interior wall surface, having VOC content
less than 50 grams/ litre litre
250.00
714.00
714.00
645.00
645.00
714.00
784.00
784.00
714.00
714.00
749.00
749.00
30.00
5000.00
11200.00
75.00
50.00
15.00
600.00
370.00
290.00
120.00
40.00
94.00
200.00
105.00
50.00
200.00
13.00
150.00
225.00
100.00
90.00
175.00
165.00
270.00
100.00
170.00
38.00
230.00
100.00
115.00
115.00
130.00
6.00
5.00
1500.00
300.00
48.00
900.00
260.00
35.00
600.00
40.00
163.93
163.93
145.72
1200.00
120.00
120.00
300.00
35.00
300.00
210.00
22.00
215.00
240.00
300.00
190.00
300.00
200.00
210.00
280.00
90.00
160.00
105.00
410.00
2.12
2.12
2.12
13.0 FINISHING
Code No. Description Unit
Note :- Rates for external plastic are for height upto 10m from ground
level in less otherwise stated.
294.85
282.00
339.70
324.30
402.15
382.10
307.25
294.35
354.50
339.10
421.40
401.35
374.15
361.30
421.50
406.10
13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating
coat of neat cement.
13.9.1 12 mm cement plaster sqm
13.9.2 20 mm cement plaster sqm
13.10 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating
coat of neat cement on the rough side of single or half brick wall.
sqm
CEMENT PLASTER IN TWO COATS
13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5
(1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1
cement : 6 fine sand).
sqm
13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5
(1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3
coarse sand) finished rough with sponge.
sqm
13.13 12 mm cement plaster 1:2 (1 cement : 2 stone dust). sqm
13.14 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single
or half brick wall. sqm
sqm
13.21 Extra for providing and mixing water proofing material in cement per bag of
plaster work in proportion recommended by the manufacturers. 50kg cement
used in
the mix
13.22 Extra for plastering exterior walls of height more than 10 m from ground level
for every additional height of 3 m or part thereof. sqm
436.30
442.75
461.85
325.80
376.65
450.30
253.05
334.20
67.80
752.40
705.90
60.55
72.80
39.35
59.75
587.20
967.85
146.65
158.85
97.05
214.30
93.75
6.25
6.85
7.80
13.35
13.29 18 mm thick plain cement mortar band in cement mortar 1:4
(1 cement : 4 fine sand):
13.29.1 Flush Band cm per metre
13.29.2 Sunk Band cm per metre
13.29.3 Raised Band cm per metre
13.29.4 Moulded Band cm per metre
13.30 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1
cement : 5 coarse sand) top
layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). cm per metre 17.85
7.60
8.35
9.55
17.80
th cement mortar 1:5 (1
5
POINTING ON BRICK WORK
13.31 Pointing on brick work or brick flooring with cement mortar 1:3
(1 cement : 3 fine sand):
13.31.1 Flush / Ruled/ Struck or weathered pointing sqm
13.31.2 Raised and cut pointing sqm
POINTING ON TILE BRICK WORK
13.32 Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand):
13.35 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand):
INTERIOR FINISHING
13.37 White washing with lime to give an even shade :
13.37.1 New work (three or more coats) sqm
13.38 Satna lime wash on walls with one coat. sqm
13.39 Colour washing such as green, blue or buff to give an even shade :
13.39.1 New work (two or more coats) with a base coat of white washing
with lime sqm
13.39.2 New work (two or more coats) with a base coat of whiting sqm
13.40 DELETED
13.41 Distempering with oil bound washable distemper of approved brand and
manufacture to give an even shade :
13.41.1 New work (two or more coats) over and including water thinnable
priming coat with cement primer sqm
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC
content less than 50 gms/litre, of approved manufacturer, of required shade and colour
complete, as per manufacturer's specification.
292.05
319.35
580.25
597.60
177.85
7.60
32.45
13.10
44.25
43.80
162.55
92.75
13.43 Applying one coat of water thinnable cement primer of approved brand
and manufacture on wall surface :
13.43.1 Water thinnable cement primer sqm
EXTERIOR FINISHING
13.44 Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm
13.45 Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over
and including priming coat of exterior primer applied @ 2.20kg/10 sqm
sqm
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
sqm
13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade:
13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
sqm
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and
including one coat of Special primer applied @
0.75 ltr /10 sqm
sqm
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required
shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of
primer applied @0.75 ltr/10 sqm of approved brand and manufacture
sqm
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an
even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat
of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
sqm
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less
than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal
resistance, dirt resistance exterior paint of required shade (Company Depot
Tinted) with silicon additives.
13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over
and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
sqm
13.50 Applying priming coat:
13.50.1 With ready mixed pink or Grey primer of approved brand and
manufacture on wood work (hard and soft wood) sqm
97.60
245.00
166.85
162.35
158.95
144.90
140.05
154.45
61.45
62.95
13.50.3 With ready mixed red oxide zinc chromate primer of
approved brand and manufacture on steel galvanised iron/ steel works
sqm
13.50.4 With ready mixed red oxide zinc chromate primer of approved
brand and manufacture on steel work (second coat)
sqm
13.51 Painting with silicon & acrylic emulsion based water thinnable sealer of
approved brand and manufacture on wet or patchy portion of plastered surfaces :
sqm
13.59 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per
sqm in the first coat and second coat respectively. sqm
13.60 Wall painting with acrylic emulsion paint of approved brand and manufacture to
give an even shade :
13.60.1 Two or more coats on new work sqm
13.61 Painting with synthetic enamel paint of approved brand and manufacture
to give an even shade :
13.61.1 Two or more coats on new work sqm
13.62 Painting with synthetic enamel paint of approved brand and manufacture
of required colour to give an even shade :
13.62.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture
sqm
13.63 Painting with aluminium paint of approved brand and manufacture to give an
even shade .
13.63.1 Two or more coats on new work 121.45 sqm
55.50
29.75
83.50
132.65
201.70
198.40
150.20
52.70
52.50
63.15
94.15
69.00
102.75
47.10
285.80
55.55
137.85
131.45
191.40
sqm
13.64 Painting with acid proof paint of approved brand and manufacture of
required colour to give an even shade :
13.64.1 Two or more coats on new work sqm 139.25
13.67.2 Two or more coats glue sizing with spar varnish or an under coat of
flatting varnish sqm
13.69 Polishing on wood work with ready mixed wax polish of approved brand and
manufacture :
13.69.1 New work sqm
5
115.10
197.40
198.20
368.30
164.15
13.70 Floor polishing on masonry or concrete floors with wax polish of
approved brand and manufacture. sqm
13.71 Lettering with black Japan paint of approved brand and manufacture per letter per cm
height
13.72 Washed stone grit plaster on exterior walls height upto 10 metre above ground
level, in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ),
furrowing the under layer with scratching tool, applying cement slurry on the under layer @
2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2
coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as
per approved pattern, including scrubbing and washing the top layer with brushes and
water to expose the stone chippings ,complete as per specification and direction of
Engineer-in-charge (payment for providing grooves shall be made separately).
sqm
13.73 Forming groove of uniform size in the top layer of washed stone grit plaster as
per approved pattern using wooden battens, nailed to the under layer, including removal of
wooden battens, repair to the edges of panels and finishing the groove complete as per
specifications and direction of the Engineer-in-charge :
13.75 Extra for washed stone grit plaster on circular work not exceeding 6 m in radius
(in two coats). sqm
13.76 Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top
layer of washed stone grit plastered surface as per approved pattern, including providing
and fixing aluminum channels of appropriate size and thickness (not less than 2 mm),
nailed to the under layer with rust proof screws and nails and finishing the groove complete
as per specifications and direction of the Engineer-in- Charge.
metre
13.77 Extra for using white cement in place of ordinary cement in the top layer of the
item of washed stone grit plaster. sqm
13.78 Providing and applying 12 mm thick (average) premixed formulated one coat
gypsum lightweight plaster having additives and light weight aggregates as vermiculite/
perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven
background such as bare brick/ block/ RCC work on walls & ceiling at all floors and
locations, finished in smooth line and level etc. complete.
sqm
13.79 Extra for addition of synthetic Polyester triangular fibre of length
6 mm, effective diameter 10-40 microns and specific gravity of 1.34 to 1.40 in cement per bag
plaster/mortar by using 125 gms. of synthetic
Polyester triangular fibre for 50 Kgs. cement used in cement mortar of 50kg
as per directions of Engineer-in-Charge. of cement 68.55
13.80 Providing and applying white cement based putty of average thickness 1 mm,
of approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
sqm 123.85
13.81 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand and manufacture,
including applying additional coats wherever required, to achieve even shade and colour.
sqm 61.45
13.85.3 With water thinnable cement primer on wall surface having VOC
content less than 50 grams/litre sqm 64.45
sqm 16.35
13.89 DELETED
79.60
5.05
985.45
62.50
63.10
140.85
110.85
88.70
82.95
363.45
68.55
123.85
54.75
90.05
78.00
116.05
80.25
121.55
61.45
64.45
217.50
19.00
11.60
16.35
13.90 Distempering with 1st quality acrylic distember (Ready mix) having
VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
13.90.1 Old work (one or more coats) sqm 56.80
13.91 Removing dry or oil bound distemper, water proofing cement paint
and the like by scrapping, sand papering and preparing the surface smooth including sqm
necessary repairs to scratches etc. complete.
13.92 Painting on G.S. sheet with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade : sqm
20.85
77.20
77.20
47.35
22.25
29.40
42.35
48.95
67.70
100.85
23.50
30.20
43.45
35.80
90.85
13.99 Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade :
13.99.1 One or more coats on old work sqm 86.55
13.106 Painting (one or more coats) with black Japan paint of approved brand and
manufacture to give an even shade. sqm
13.107 Providing and fixing C.P. brass chain and rubber plug complete for sink or wash
basin:
13.107.1 32 mm dia each
13.107.2 40 mm dia each
13.108 Distempering with 1st quality acrylic distemper (ready made) having VOC
content less than 50 gm per ltr. of approved manufacturer and of required shade and
colour complete. as per manufacturer's specification.
13.110.2 Old work (One or more coats) applied @ 1.82 ltr/10 sqm. sqm
79.40
91.25
77.05
185.40
82.95
3.20
78.60
76.40
76.40
50.60
94.15
63.25
191.40
118.85
13.111 Finishing walls with Acrylic Smooth exterior paint of required shade :
13.111.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement
paint surface
sqm 111.60
13.111.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 74.75
13.112 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade
13.112.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over
existing cement paint surface sqm 108.60
13.112.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 74.10
13.113 Varnishing with varnish of approved brand and manufacture:
13.113.1 One or more coats with copal varnish sqm 79.45
13.113.2 One or more coats with spar varnish sqm 79.85
13.114 Melamine polishing on wood work (one or more coat). sqm 118.35
13.115 Varnishing with flatting varnish of approved brand and manufacture one or
more coats on old work. sqm 82.95
13.116 Polishing in high gloss/matt finish melamine clear polish on wood work in
required color/wooden shade texture with following process in the sequence as detailed
below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then
with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying
time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with
ample water to remove excess sealer layer and make the surface further
smooth after this wet rubbing, then surface is applied with special grade
melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be
allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this
surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using
melamine clear polish and melamine thinner in required proportion. This 1st
coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed
smooth, which is further allowed to dry for 12 hrs. The final melamine
polish is applied with compressor pressure spray gun using melamine clear
polish and melamine thinner mixed in required proportion complete as per
direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without
gap of time.)
sqm 1156.55
SUB HEAD : 14.0
REPAIRS TO BUILDING
291
111.60
74.75
108.60
74.10
79.45
79.85
118.35
82.95
1156.55
BASIC RATES (SH: 14.0 REPAIRS TO BUILDING)
Code No. Description Unit
0087 Hire Charges of Suction Jeting machine 2200 PSI machine i/c POL and
operator day
250.00
700.00
200.00
190.00
4000.00
40000.00
714.00
714.00
784.00
714.00
784.00
714.00
645.00
645.00
784.00
714.00
714.00
784.00
714.00
784.00
714.00
645.00
784.00
714.00
714.00
714.00
714.00
749.00
749.00
784.00
853.00
784.00
853.00
1400.00
1350.00
40.00
500.00
0313 Blown type petroleum bitumen of penetration 85/25 of
approved quality tonne
0597 Bright finished or black enameled mild steel butt hinges 50x37x 1.50 mm
10 Nos
0608 Nickel plated bright finished mild steel piano hinges 1 mm thick 25 mm wide
metre
0637 Bright finished or black enameled mild steel screws 40 mm 100 Nos
0639 Bright finished or black enameled mild steel screws 25 mm 100 Nos
0640 Bright finished or black enameled mild steel screws 20 mm 100 Nos
0761 Fuel wood quintal
0771 Kerosene oil litre
0772 White cement based polymer modified self curing compound
in powder form kg
47.00
5000.00
440.00
110.00
170.00
168.00
36.00
290.00
140.00
190.00
45.00
220.00
170.00
100.00
905.00
805.00
690.00
421.00
180.00
300.00
290.00
240.00
180.00
160.00
80.00
49.00
39.00
60.00
40.00
35.00
500.00
50.00
15.00
600.00
165.00
150.00
225.00
100.00
90.00
175.00
120.00
38.00
230.00
100.00
115.00
115.00
130.00
28.00
1500.00
300.00
48.00
4750.00
4950.00
4850.00
120.00
5200.00
260.00
1100.00
850.00
776.00
791.00
500.00
300.00
600.00
30.00
35.00
35.00
2.00
84.00
1800.00
1314 C.P.brass chain with 32 mm dia rubber plug each
2407 Float glass panes of nominal thickness 5 mm (weight not less than 12.50
kg/sqm) sqm
2602 Common burnt clay F.P.S. (non modular) bricks class designation 7.5
1000 Nos
8204 A.P.P. modified 3 mm thick membrane reinforced with glass fibre matt sqm
8205 A.P.P. modified 3 mm thick membrane reinforced with polyester matt sqm
8206 Bitumen primer for bitumen membrane litre
8207 Geotextile 120 grams per sqm membrane sqm
8500 Water for jetting / blowback 1000 litre
8505 Acrylic exterior paint litre
8506 Premium Acrylic exterior paint litre
8507 Textured exterior paint litre
8508 Primer for cement paint litre
9977 Carriage L.S.
9988 Carriage and sundries L.S.
9999 Sundries L.S.
40.00
40.00
25.00
325.00
475.00
1290.00
103.00
187.35
437.15
163.93
163.93
187.35
145.72
145.72
163.93
145.72
163.93
309.00
515.00
357.00
172.00
4590.00
60.00
120.00
300.00
12.50
300.00
46.00
40.00
145.00
765.00
48.00
62.00
810.00
80.00
120.00
130.00
190.00
210.00
85.00
45.00
1500.00
200.00
210.00
280.00
90.00
2.12
2.12
2.12
14.0 REPAIRS TO BUILDING
Code Description Unit Rate
No.
14.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area
2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and
preparing and plastering the surface of the walls complete, including disposal of rubbish to
the dumping ground, all complete as per direction of Engineer-in-Charge.
each
14.4 Making the opening in brick masonry including dismantling in floor or walls by
cutting masonry and making good the damages to walls, flooring and jambs complete, to
match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping
ground, all complete as per direction of Engineer-in-Charge.
14.5.2 Float glass panes of nominal thickness 5 mm (weight not less than
12.5kg/sqm) sqm
14.6.2 Float glass panes of nominal thickness 5 mm (weight not less than
12.5kg/sqm) sqm
Rate
462.30
478.00
1505.30
948.05
712.85
190.25
1046.95
941.95
1245.15
1351.15
1654.30
14.7 Renewing glass panes and refixing existing wooden fillets:
14.7.1 Float glass panes of nominal thickness 4 mm (weight not less
than 10kg/sqm) sqm
14.10 Refixing old glass panes with putty and nails sqm
14.11 Fixing old glass panes with wooden fillets (excluding cost of fillets) sqm
14.12 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in
existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar,
including cleaning, refilling, making good the chase with matching concrete, plastering and
painting the exposed portion of the clamps complete.
each
14.13 Regrading terracing of mud phaska covered with tiles or brick, in cement mortar
by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska
to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement
mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with
new ones and disposal of unserviceable material to the dumping ground (the cost of the
new tiles or brick excluded), all complete as per direction of Engineer-in-Charge.
sqm
14.14 Replacing sand stone slabs in roofing, laid in cement mortar 1:4 (1 cement : 4
coarse sand), including necessary repairs and cement pointing with same mortar
complete, including disposal of rubbish to dumping ground, all complete as per direction of
Engineer-in-Charge.
14.14.1 Red/ white sand stone slabs 30 to 50 mm thick
sqm
14.15 Renewing wooden battens in roofs, including making good the holes in wall
and painting with oil type wood preservative of approved brand and manufacture
complete, including removal of rubbish to the dumping ground, all complete as per
direction of Engineer-in-Charge.
1358.35
66.05
59.35
46.40
603.05
560.60
468.40
577.90
1099.15
92213.65
96739.70
63238.90
14.16.2 Above 4.00 metres and upto 5.00 metres length.
14.16.2.1 Sal wood beams cum
14.16.2.2 Hollock wood beams cum
14.17 Raking out joints in lime or cement mortar and preparing the surface for re-
pointing or replastering, including disposal of rubbish to the dumping ground, all complete
as per direction of Engineer-in-Charge.
sqm
14.18 Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of
integral water proofing compound by weight of cement for flat tile bricks on top of mud
phaska :
14.18.1 With F.P.S. brick tiles sqm
14.18.2 With modular brick tiles sqm
14.19 Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and
removing materials to any distance within compound and stacking.
kg
14.20 Fixing of old wind tie with new fittings including painting two or more coats with
anticorrosive bitumastic paint of approved brand & manufacturer over and including
priming coat of ready mixed zinc chromate yellow primer of approved brand.
metre
14.21 Renewing bottom rail and/or top runner of collapsible gate including making
good all damages and applying priming coat of zinc chromate yellow primer of approved
brand and manufacturer.
kg
14.22 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting
and fixing the same with necessary clamps, nuts and bolts/welding and erection etc.
complete.
14.22.1 Wheel 50 mm dia and below per wheel
14.22.2 Wheel above 50 mm dia per wheel
EARTH WORK
14.23 Pumping out water caused by springs, tidal or river seepage, broken water
mains or drains and the like. kilo litre
14.24 Mud mortar made with local clay good earth. cum
BRICK WORK
14.25 Brick work with common burnt clay bricks of class designation 7.5 in mud
mortar cum
WOOD WORK
14.26 Providing and fixing 25 mm thick shutters for cup board etc. :
14.26.1 Panelled or panelled & glazed shutters :
14.26.1.1 Superior class teak wood including nickel plated bright
finished M.S. piano hinges with necessary screws.
sqm
14.26.1.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with
necessary screws. sqm 3979.65
99011.80
65503.80
59.75
114.70
115.95
4.45
107.00
246.15
150.95
253.00
190.40
823.15
5700.55
4583.60
S. piano hinges with
14.26.2 Glazed shutters :
14.26.2.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges
with necessary screws. sqm 4555.30
14.26.2.2 Ist class teak wood including nickel plated
14.27 Providing and fixing plain jaffri door and window shutters including bright or/and
black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm
apart (frames to be paid separately), including fixing 50x12 mm beading complete with :
kg
14.30 Providing joists (karries) including hoisting, fixing in position and applying wood
preservative on unexposed surface etc. complete with :
3904.90
4155.75
295.20
362.10
99.70
91146.55
57984.40
652.40
465.10
412.95
726.00
618.95
600.25
230.75
200.55
147.05
14.34 Providing and fixing 150 mm bright finished floor brass door stopper
with rubber cushion, necessary brass screws etc. to suit shutter thickness complete each
14.35 Providing and fixing bright finished brass hard drawn hooks and eyes :
14.35.1 300 mm each
14.37 Providing and fixing 300 mm long bright finished brass chain with hook for fan
light including necessary brass screws etc. complete. each
14.38 Providing and fixing bright finished brass quadrant stay 300 mm long with
necessary brass screws etc. complete. each
14.39 Providing and fixing bright finished brass helical door spring (superior quality).
each
14.40 Providing and fixing chromium plated brass butt hinges with necessary
chromium plated brass screws etc. complete.
14.40.1 125x70x4 mm (ordinary type) each
14.40.2 100x70x4 mm (ordinary type) each
14.40.3 75x65x4 mm (heavy type) each
14.40.4 75x40x2.5 mm (ordinary type) each
14.40.5 50x40x2.5 mm (ordinary type) each
14.41 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with
necessary chromium plated brass screws, nuts, bolts and washers etc.
complete.
each
FINISHING
14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior
side, up to seven story height made with 40 mm dia
M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup &
lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for working platform etc. and maintaining it
in a serviceable condition for the required duration as approved and removing
it there after .The scaffolding system shall be stiffened with bracings,
runners, connection with the building etc wherever required for inspection of
work at required locations with essential safety features for the workmen etc.
complete as per directions and approval of Engineer- in-charge .The
elevational area of the scaffolding shall be measured for payment
purpose .The payment will be made once irrespective of duration of
scaffolding.
sqm
Note: - This item to be used for maintenance work judicially, necessary
deduction for scaffolding in the existing item to be done.
233.10
86.85
83.35
74.80
60.05
52.70
40.20
64.25
163.25
462.75
172.20
147.70
164.20
99.40
41.30
255.80
285.00
14.73 Providing and fixing bright finished brass casement window fasteners
or peg stays to windows/ ventilators with necessary welding and machine kg
screws etc. complete.
14.74 Providing and fixing 14 mm bright finished brass spring catch to steel centre
hung ventilators with necessary welding and machine screws etc. complete.
each
14.75 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and
under, including cutting the patch in proper shape, raking out joints and
preparing plastering the wall surface with white cement based polymer
modified self curing mortar, including disposal of rubbish, all complete as per
the direction of Engineer-In-Charge.
sqm
ROUTINE MAINTENANCE WORK
14.75A Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre
capacity at all heights with coconut brushes, duster etc., removal of silt,
rubbish from the tank and cleaning the tank with fresh water disinfecting with
bleaching powder @ 0.5gm per litre capacity of tank including marking the
date of cleaning on the side of tank body with the help of stencil and paint and
disposing of malba all complete as per direction of Engineer-in-Charge. (The
old date already written on tank should be removed with paint remover or
black paint and if date is not written with the stencil or old date is not removed
deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings
or ball cock is damaged that is to be repaired by contractor at his own cost
and nothing extra will be paid on this account)
litre
14.76 Cleaning and desilting of gully trap chamber, including removal of rubbish
mixed with earth etc. and disposal of same, all as per the direction of
Engineer-in-charge.
each
14.77 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic
operated high pressure suction cum jetting sewer cleaning machine fitted with
pump having 4000 litres suction capacity and 6000 litres water jetting tank
capacity including skilled operator, supervising engineer etc. for cleaning and
partial desilting of manholes and dechocking of sewer lines. Dechocking and
flushing of sewer line from one manhole to another by high pressure jetting
system of 2200 PSI for sewer line from 150mm dia upto 300mm
metre
14.78 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent
staging) including disposal of slit and rubbish, all as per direction of Engineer-
in-Charge. The cleaning shall consist following operations:-
(i) Tank shall be emptied of water by pumping & bottom shall be cleaned of
silt and other deposits.
(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire
brush etc. and pressure washed with water.
(iii) Chlorination of RCC internal surface by liquid chlorine.
(iv) The treated surface shall be dried using air jetting and all loose particles
shall be removal from the surface.
(v) Finally the surface shall be treated with ultraviolet radiation etc. as per
direction of Engineer-in-Charge. sqm
484.30
59.40
540.35
0.40
89.45
285.90
71.30
14.79 Disconnecting damaged overhead/terrace PVC water storage tank
of any size from water supply line and removing from the terrace including shifting at
ground level as per direction of Engineer-in-charge.
each
14.80 Providing & fixing White vitreous china water closet squatting pan (Indian type)
along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site
complete with all operations including all necessary materials, labour and disposal of
dismantled material i/c malba, all complete as per the direction of Engineer-in charge.
each
14.82 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c
malba all complete as per directions of Engineer-in- Charge.
each
14.83 Hacking of CC flooring including cleaning for surface etc. complete as per
direction of the Engineer-in-Charge. sqm
each
14.86 Providing and laying in situ seven course water proofing treatment with APP
(Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20
Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702,
3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick
of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron
HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is
protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be
finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement :
3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a
12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and
finished neat (item of laying brick tiles shall be paid for separately).
sqm
14.87 Providing and laying in situ five course water proofing treatment with
APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first
coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20
kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702,
3rd layer of roofing membrane APP modified Polymeric membrane
2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with
centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix
and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top
most layer shall be finished with brick tiles of class designation 10 grouted with cement
mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by
weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and
finished neat (item of laying brick tiles shall be paid for separately).
sqm
14.88 Providing and laying in situ seven course water proofing treatment with APP
(Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of
bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20
kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702,
3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm thick
of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100
micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix
is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be
finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement :
3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a
12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand) and finished neat (item of
laying brick tiles shall be paid for separately).
sqm
14.89 Providing and fixing APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 2 mm thick water proofing membrane, black finished reinforced with
glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40
litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre
and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using
Butane torch and sealing all joints etc., and preparing the surface complete. The vital
physical and chemical parameters of the membrane shall be as under : Joint strength in
longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in
longitudinal and transverse direction as 60/80N. Softening point of membrane not less than
150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147.
The laying of membrane shall be got done through the authorised applicator of the
manufacture of membrane.
2962.80
3850.65
243.10
110.70
2.85
2.85
325.95
615.00
454.80
732.75
445.80
14.90 Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a
coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at
25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using
butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical
parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300
N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C.
Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got
done through the authorised applicator of the manufacturer of membrane :
14.90.1 3 mm thick sqm 534.10
14.91 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water
proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for
bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and
viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints
etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :
Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and
transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -
2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
sqm 103.50
14.93 Providing round the clock security guard without gun for watch & ward of
Government premises and its all belongings by deploying neatly dressed security guards
in 8 hour's shift including necessary T&P like torch, lathi and uniform etc.complete,as per
the direction of Engineer-in-charge. (One job means 8 hour's duty).
307
bre matt consisting of a
actured of density at
all be laid using
nd chemical
on at 23°C as 350/300
ne not less than 150°C.
mbrane shall be got
563.50
103.50
1077.30
1169.65
BASIC RATES (SH:15.0 DISMANTLING AND DEMOLISHING)
Code No. Description Unit
1200.00
1200.00
1600.00
800.00
714.00
714.00
714.00
714.00
645.00
645.00
784.00
714.00
784.00
714.00
714.00
784.00
714.00
500.00
50.00
163.93
2.12
2.12
2.12
15.0 DISMANTLING AND DEMOLISHING
Code No. Description Unit
701.95
2007.10
1239.60
2928.10
2619.45
947.10
7.45
581.15
1470.00
701.95
1698.45
3839.15
4414.15
5522.25
954.80
2027.10
15.10 Dismantling dressed stone work ashlar face stone work, marble work
or precast concrete work manually/ by mechanical means including stacking of serviceable
and disposal of unserviceable material within 50 metres lead as per direction of Engineer-
in-charge :
15.10.1 In lime mortar cum
15.10.2 In cement mortar cum
15.11 Removing mortar from and cleaning stones and concrete articles (net quantity
of stacks of cleaned materials will be measured):
15.11.1 In lime mortar cum
15.11.2 In cement mortar cum
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter
including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
:
15.12.1 Of area 3 sq. metres and below each
15.12.2 Of area beyond 3 sq. metres each
15.13 Taking out doors, windows and clerestory window shutters (steel or wood)
including stacking within 50 metres lead :
15.13.1 Of area 3 sq. metres and below each
15.13.2 Of area beyond 3 sq. metres each
15.14 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres
span and 5 metres height including stacking the material within 50 metres lead :
15.15.1 Of sectional area 40 square centimetres and above cum per metre
span
15.16 Extra for dismantling trusses, rafters, purlins etc. of wood work for every
additional height of one metre or part thereof beyond 5 metres :
15.17 Dismantling steel work in single sections including dismembering and stacking
within 50 metres lead in:
15.17.1 R.S. Joists kg
15.17.2 Channels, angles, tees and flats kg
15.18 Dismantling steel work in built up sections in angles, tees, flats and
channels including all gusset plates, bolts, nuts, cutting rivets, welding
etc. including dismembering and stacking within 50 metres lead. kg 4.65
15.19 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking
within 50 metres lead
as per direction of Engineer-in-charge. kg 3.20
15.20 Extra for dismantling trusses, rafters, purlins etc. of steel work for kg per
every additional span of one metre or part thereof beyond 10 metres metre span 0.70
15.21 Extra for dismantling trusses, rafters, purlins etc. of steel work for kg per
every additional height of one metre or part thereof beyond 5 metres. metre height 0.70
15.22 Extra for marking of structural steel work required to be re-erected. kg 3.80
15.23 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm sqm 60.50
15.23.2 For thickness of tiles above 25 mm and up to 40 mm sqm 93.40
15.24 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of
unserviceable material within
50 metres lead : cum 1086.45
15.25 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal
of unserviceable material
within 50 metres lead. sqm 219.75
15.26 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of
unserviceable material within
50 metres lead. sqm 86.80
15.27 Demolishing mud phaska in terracing and disposal of material within
50 metres lead. cum 753.75
15.28 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres
lead of:
15.28.1 G.S. Sheet sqm 136.00
15.28.2 Asbestos Cement sheet sqm 63.75
15.29 Dismantling stone slab roofing over wooden karries or R.C.C. battens (dismantling karries and battens to be paid
for separately), including stacking of serviceable material and disposal of unserviceable material
within 50 metres lead. cum 2197.55
15.30 Dismantling jack arch roofing and floors including stacking of serviceable material and disposal of
unserviceable material within
50 metres lead. sqm 209.40
15.31 Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and
disposal of
unserviceable material within 50 metres lead. sqm 173.15
15.32 Demolishing thatch roofing including mats, bamboo, jaffari etc. complete including stacking of serviceable
material and disposal of
unserviceable material within 50 metres lead. sqm 47.65
1207.25
2372.30
394.45
568.15
302.70
414.55
118.30
155.75
3674.50
14.70
487.95
1.35
708.30
2.80
2.80
1.90
5
dismembering and stacking
70
70
3.80
aterial within 50 metres lead.
0
0
e material and disposal of
5
al and disposal of
5
e material within 50 metres
0
g of serviceable material and
5
ing stacking of serviceable
5
15.33 Dismantling wooden ballies in posts and struts including stacking
within 50metres lead. metre 17.30
15.42 Dismantling C.I. or asbestos rain water pipe with fittings and clamps
including stacking the material within 50 metres lead :
15.42.1 75 to 80 mm dia pipe metre 62.40
15.42.2 100 mm dia pipe metre 64.30
15.42.3 150 mm dia pipe metre 66.20
15.43 Dismantling manually/ by mechanical means including stacking of
serviceable material and disposal of unserviceable material within
50 metres lead as per direction of Engineer-in-charge :
15.43.1 Water bound macadam road sqm 179.65
15.43.2 bituminous road sqm 353.65
15.44 Dismantling G.I. pipes (external work) including excavation and refilling
trenches after taking out the pipes, manually/ by mechanical means including stacking of
pipes within 50 metres lead as per direction of Engineer-in-charge :
each 576.25
15.49 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of
various sizes including demolishing of R.C.C. work manually/ by mechanical means and
stacking of useful materials near the site and disposal of unserviceable materials within 50
metres lead as per direction of Engineer-in-charge.
each 336.25
15.50 Dismantling of R.C.C. spun vent shaft including excavating the cement
concrete pit completely, taking out the shaft, refilling the excavated gap, stacking the
useful materials near the site and
disposal of unserviceable materials within 50 metres lead.
each 3817.90
15.51 Dismantling of road gully chamber of various sizes including C.I.
grating with frame including stacking of useful materials near the
site and disposal of unserviceable materials within 50 metres lead including
refilling the excavated gap. each 791.65
317
17.30
192.95
204.80
11.80
30.35
53.50
62.50
50.35
64.15
74.70
238.65
357.60
46.50
62.40
64.30
66.20
179.65
353.65
124.10
134.25
340.70
448.15
583.30
574.85
1447.60
273.80
332.25
576.25
336.25
3817.90
791.65
744.60
264.65
976.60
598.05
910.15
1396.00
1976.05
45.05
46.50
2328.55
347.90
219.35
BASIC RATES (SH: 16.0 ROAD WORK)
Code No. Description Unit
0009 Pumping charges of concrete including Hire charges of pump, piping work &
accessories etc. cum
0083 Hire charges of TATA 407 or equivalent for local shifting. day
0100 Bandhani day
0101 Bhisti day
0102 Blacksmith 1st class day
0103 Blacksmith 2nd class day
0113 Chowkidar day
0114 Beldar day
0115 Coolie day
0116 Fitter (grade 1) day
0123 Mason (brick layer) 1st class day
0124 Mason (brick layer) 2nd class day
0125 Mason (for plain stone work) 2nd class day
0126 Mason (for ornamental stone work) 1st class day
0128 Mate day
0130 Mistry day
0131 Painter day
0138 Sprayer (for bitumen, tar etc.) day
0139 Skilled Beldar (for floor rubbing etc.) day
7296 Granite of colour black, cherry/ruby red 30 mm thick (slab area upto 0.50 sqm)
sqm
7297 Granite of all colour except black, cherry/ruby red 18 mm thick (slab area
upto 0.50 sqm) sqm
7298 Granite of colour black, cherry/ruby red 18 mm thick (slab area above 0.50
sqm) sqm
7299 Granite of all colour except black, cherry/ruby red 18 mm thick (slab area
above 0.50 sqm) sqm
7300 Granite of all colour except black, cherry/ruby red 30 mm thick (slab area
above 0.50 sqm) sqm
8577 Crates made of Mesh type 10x12 (D=100 mm) Zn+PVC coated. Mesh wire
diameter 2.70/3.70 mm (ID/OD). sqm
8578 Crates made of Mesh type 10x12 (D=100 mm) Zn+10% Al alloy + PVC
coated. Mesh wire diameter 2.70/3.70 mm (ID/OD). sqm
800.00
800.00
3000.00
400.00
350.00
7700.00
210.00
350.00
300.00
6000.00
750.00
3750.00
6000.00
250.00
300.00
3500.00
37.30
3000.00
800.00
1200.00
800.00
10000.00
550.00
13000.00
1200.00
600.00
925.00
1500.00
2400.00
800.00
1300.00
3.30
600.00
300.00
1200.00
200.00
200.00
950.00
450.00
700.00
15000.00
13000.00
1500.00
800.00
2400.00
3000.00
400.00
300.00
3.30
450.00
12000.00
1400.00
714.00
714.00
784.00
714.00
645.00
645.00
645.00
784.00
784.00
714.00
714.00
784.00
714.00
784.00
714.00
714.00
714.00
749.00
650.00
650.00
1000.00
1000.00
1300.00
1350.00
1400.00
1350.00
1350.00
1400.00
1000.00
25614.00
30800.00
32950.00
34790.00
29.00
47.00
360.00
12.00
38.00
20.00
20.00
5000.00
25.00
440.00
130.00
400.00
180.00
300.00
290.00
1130.00
500.00
40.00
1500.00
900.00
4750.00
4900.00
4950.00
4850.00
4850.00
430.00
80.00
5500.00
25.00
80.00
600.00
1100.00
900.00
2.00
80.87
84.00
11.00
187.35
437.15
163.93
163.93
145.72
178.19
163.93
145.72
163.93
192.86
145.72
204.92
178.19
163.93
163.93
163.93
163.93
145.72
163.93
145.72
163.93
16.39
4590.00
240.00
1360.00
1360.00
1400.00
1400.00
550.00
600.00
1200.00
1200.00
30.00
24500.00
318.00
1300.00
36.00
115.00
130.00
38100.00
1800.00
1900.00
1000.00
2000.00
1200.00
2100.00
38150.00
29.00
18250.00
80.00
3950.00
29150.00
27100.00
810.00
425.00
9.00
800.00
910.00
450.00
200.00
250.00
290.00
336.00
5600.00
66.00
72.00
440.00
1443.00
600.00
7.00
42.00
145.00
300.00
330.00
380.00
485.00
2.12
2.12
16.0 ROAD WORK
Code No. Description Unit
ROADS
16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12
tonne capacity after excavating earth to an average of 22.5 cm depth,
dressing to camber and consolidating with road roller including making good
the undulations etc. and re-rolling the sub grade and disposal of surplus
earthwith lead upto 50 metres.
sqm
16.2 Extra for compaction of earth work in embankment under optimum moisture
conditions to give at least 95% of the maximum dry density (proctor density). cum
cum
16.5 Laying water bound macadam sub-base with brick aggregate and binding
material, earth etc. including screening, sorting and spreading to template
and consolidation with light power road-roller etc. complete.(payment for
brick aggregate and moorum etc. to be made separately)
180.50
20.55
1937.60
1624.50
1837.25
974.25
1041.15
1865.00
2065.70
1557.25
624.55
888.30
865.80
725.60
725.60
21.80
16.7 Brick edging in full brick width and half brick depth including
excavation, refilling and disposal of surplus earth lead upto 50 metres.
16.7.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 metre 179.50
16.8 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead
upto 50 metres :
16.8.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 metre 49.90
sqm
16.11 Dry stone pitching 22.5 cm thick including supply of stones and preparing
surface complete. sqm
16.12 Dry brick pitching half brick thick in drains including supply of bricks and
preparing the surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 sqm
16.13 Cutting road and making good the same including supply of extra quantities of
materials i.e. aggregate, moorum screening, red bajri and labour required.
FENCING
16.15 Supplying at site :
16.15.1 R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement :
1.5 coarsesand : 3 graded stone aggregate
12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required
as per direction of Engineer-in- charge (cost of earth works in excavation,
concrete works in foundation to be paid separately).
cum
16.15.2 Welded steel wire fabric of required width having rectangular
mesh painted with two or more coats of enamel paint of approved shade over a
coat of primer (Priming & Painting to be paid for separately).
kg
16.16 Supplying and fixing turn buckles and straining bolts for barbed wire fencing.
each set
sposal of surplus earth lead
27.55
190.05
821.95
607.20
4157.85
2592.10
242.85
28603.00
74.45
243.75
16.17 Fencing with R.C.C. post placed at required distance, embedded in
cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post
one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum),
between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed
while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be
made per metre cost of total length of barbed wire used.
16.17.1 With G.I. barbed wire metre 12.45
16.18 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post,
last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with
horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m
(minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth
work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.
16.18.1 With G.I. barbed wire metre 19.60
16.19 Supplying at site Angle iron post & strut of required size including
bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling kg
holes upto 10 mm dia. etc. complete.
16.20 Welded steel wire fabric fencing with posts of specified material and of standard
design placed and embedded in cement concrete blocks 45x45x 60 cm of mix 1:5:10 (1
cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post,
last but one end post and corner post shall be strutted on both sides and end post on one
side only and struts embedded in cement concrete blocks 70x45x50 cm of the same
mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I.
staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts,
welded steel wire fabric, painting, earth work in excavation and concrete to be paid for
separately).
sqm
ROAD SIGNS
16.21 Engraving letters in hard stone per cm height
per letter
16.22 Providing and fixing 15x15x90 cm boundary stone of hard stone with top 30 cm
chisel dressed on all four sides including top (cost of excavation, refilling and concrete etc.
to be paid for separately).
each
16.23 Providing and fixing 15 cm dia at top, 20 cm at bottom and 90 cm high precast
reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size) boundary stone as per standard design, including
finishing smooth with cement mortar 1:3 (1 cement : 3 fine sand) (cost of excavation,
refilling and concreting to be paid for separately).
each
ed on both sides and end post
g per 100 metres (minimum),
ed to 6 mm bar nibs fixed
arately) :- Payment to be
5
crete blocks, every 15th post,
only and provided with
9.38 kg per 100 m
. (Cost of posts, struts, earth
length of barbed wire used.
0
99.95
55.00
8.70
222.40
726.90
16.24 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1
cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal
size) kilometre stone as per standard design, including finishing
smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding
the cost of earth work, concrete in foundation, painting and lettering
etc. which shall be paid for separately.
16.24.1 35x111x25 cm size each
16.24.2 50x152.5x25 cm size each
16.24.3 35x93.5x18 cm size each
SURFACE DRESSING
16.25 Surface dressing on new surface with paving bitumen of grade VG -
10 of approved quality using 2.25 kg of bitumen per sqm with 1.65
cum of stone chippings 13.2 mm nominal size per 100 sqm of
road surface, including consolidation with road roller of 6 to 8 tonne
capacity etc. complete: sqm
16.26 Surface dressing on new surface in two coats with bitumen of grade
VG -10 of approved quality using 1.8 kg of bitumen per sqm with 1.5
cum of stone chippings 13.2 mm nominal size per 100 sqm of road
surface for first coat and 1.1 kg. of bitumen per sqm with 1.00 cu.
metre of stone chippings 11.2 mm nominal size per 100 sqm of
road surface for second coat, including consolidation of each coat separately
with road roller of 6 to 8 tonne capacity etc. complete. sqm
PREMIX CARPET
16.30 Providing and applying tack coat using hot straight run bitumen of grade VG -
10, including heating the bitumen, spraying the bitumen with mechanically operated spray
unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per
specifications :
16.32.1 With paving Asphalt grade VG - 10 heated and then mixed with
solvent at the rate of 70 grams per kg of asphalt sqm
16.33 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings
of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot
bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a
tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9
tonne capacity etc. complete (tack coat to be paid for separately).
16.33.1 With paving Asphalt grade VG - 10 heated and then mixed with
solvent at the rate of 70 grams per kg of asphalt sqm
16.34 2 cm premix carpet surfacing with 2.4 cum of stone chippings 11.2
mm nominal size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen
content) complying with IS : 8887, using 96 kg per cum of chippings, including
consolidation with road roller of 6 to 9 tonne capacity etc. complete.
sqm
16.35 2.5 cm premix carpet surfacing with 3 cum of stone chippings 10 mm nominal
size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen contents)
complying with IS : 8887, using 96 kg per cum of chippings of road surface, including
consolidation with road roller etc complete.
sqm
16.36 Providing and laying Bitumen Penetration Macadam with hard stone aggregate
of quality, size and grading as specified, with bitumen of suitable penetration grade,
including required key aggregate as specified, spreading coarse aggregate with the help of
self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure
distributor and then spreading key aggregate with the help of aggregate spreader
complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to
achieve specified values of compaction and surface accuracy :
16.36.1 For 50mm compacted thickness using coarse aggregate of size 50-
20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm graded
@ 0.15 cum per 10 sqm. With paving asphalt grade VG - 10 @ 50 kg/ 10 sqm.
sqm
16.36.2 For 75 mm compacted thickness in two layers using stone
aggregate of size 63-41 mm graded @ 0.90 cum per 10 sqm key aggregate of
size 20.0 mm graded @ 0.18 cum per 10 sqm. With paving asphalt grade VG -
10 @ 68 kg/ 10 sqm.
sqm
16.37 Providing and laying bitumen mastic wearing course (as per specifications)
with industrial bitumen of grade 85/25 conforming to IS : 702, prepared by using mastic
cooker and laid to required level and slope, including providing antiskid surface with
bitumen precoated fine grained hard stone chipping of approved size at the rate of 0.005
cum per 10 sqm and at approximate spacing of 10 cm centre to centre in both directions,
pressed into surface protruding 1 mm to 4 mm over mastic surface, including cleaning the
surface, removal of debris etc. all complete. (Considering bitumen using 10.2% as per
MORTH specification).
16.39.1 With paving Asphalt grade VG - 10 heated and then mixed with
solvent at the rate of 70 grams per kg of asphalt sqm
SEAL COAT
16.40 Providing and laying seal coat of premixed fine aggregate ( passing
2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade
VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of
road surface, including rolling and finishing with road roller all complete.
sqm
16.41 Providing and laying seal coat over prepared surface of road with bitumen
heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade
VG - 10 and blinding surface with
0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36
mm sieve) per 100 sqm of road surface, including rolling and finishing with power road
roller all complete.
sqm
Note: Seal coat items to be operated only with the prior approval of chief
Engineer concerned.
CONCRETE PAVEMENTS
16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
40 mm nominal size) in pavements, laid to required slope and camber in panels as
required including consolidation finishing and tamping complete.
cum
16.43 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi
tracks/ runways, using cement content as per design mix, using coarse sand and graded
stone aggregate of 40 mm nominal size in appropriate proportions as per approved &
specified design criteria, providing dowel bars with sleeve/ tie bars wherever required,
laying at site, spreading and compacting mechanically by using needle and surface
vibrators, levelling to required slope/ camber,
2499.40
4547.15
1670.60
178.15
248.00
137.85
169.80
107.45
45.20
36.60
11.60
7.90
16.35
10.85
189.25
211.50
196.00
227.00
254.80
235.45
170.20
205.25
414.20
611.55
726.95
1163.10
285.00
331.75
299.15
427.75
501.70
450.20
79.85
106.10
7399.20
finishing with required texture, including steel form work with sturdy
M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10
mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and
sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with
sleeve/ tie bars to be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix
is payable/ recoverable separately.
cum
16.44 Extra for providing and mixing hardening compound of approved quality
as per manufacturer's specification in cement concrete. litre 48.15
16.45 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the
joints dust free with
high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. per cm
(Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated depth per cm width per metre
fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and length 4.70
IS: 1834 for hot sealing bitumen compound grade A.)
16.46 Providing and filling in position rubberized bitumen hot sealing compound
for sealing of expansion joints in roads / pavements all complete as per direction of the
Engineer-in-Charge.
16.46.1 Using grade 'A' sealing compound conforming to IS: 1834. per cm
depth per cm width per metre
length 7.50
9492.90
10006.65
5
pavements after making the
per cm
depth per cm width per metre
ength 4.70
158.50
101.60
h ready mixed road marking
95
0
MISCELLANEOUS
16.49 Making bell mouth opening/ entrance of size 100x50x50 cm for drainage pipe
under footpath, including providing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) for shape of bell mouth, including plastering
providing and fixing precast R.C.C./ S.F.R.C. slab including plastering with cement mortar
1:3 (1 cement : 3 fine sand) of 6 mm thickness on exposed surface of the slab & bell mouth
including centring, shuttering & neat cement punning inside the bell mouth etc. all
complete.
each
16.50 Providing and fixing Glow studs of size 100x20 mm made of heavy duty body
shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or
ABS having electronically welded micro- prismatic lens with abrasion resistant coating as
approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in
accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5)
degress to base .The reflective panels on both sides with at least 12 cm of reflective area
up each side. The luminance intensity should be as per the specification and shall be
tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs
shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure
recommended by the manufacturer complete and as per direction of Engineer-in-charge.
each
16.51 Preparation of sub-base road pavement with commercial dry lime (slaked), fly
ash stabilised soil with a mix of 3% lime, 12% fly ash and 85% local suitable soil by weight,
so as to achieve minimum field C.B.R. of 20, including mixing, rolling with road roller curing
etc. all complete.
cum
16.53 Providing and fixing concertina coil fencing with punched tape concertina
coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6
metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or
3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with
G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire
tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced
barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/
sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of
M.S. angle, C.C. blocks shall be paid separately)
metre
2712.20
175.50
1321.95
12038.85
303.65
16.54 Providing and laying Dense Graded Bituminous Macadam using
crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and
rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and
density, complete as per specificatons
and directions of Engineer-in-Charge.
cum
16.54.2 50 to 100 mm average compacted thickness with bitumen of grade
VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2%
(percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of
60-90 TPH
capacity.
cum
16.55 Providing and laying bituminous macadam using crushed stone aggregates of
specified grading premixed with bituminous binder, transported to site by tippers, laid over
a previously prepared surface with paver finisher equiped with electronic sensor to the
required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem
rollers as per specifications to achieve the desired compaction and density, complete as
per specificatons and directions of Engineer-in-Charge.
cum
16.55.2 50 to 100 mm average compacted thickness with bitumen of grade
VG-30 @ 3.50% (percentage by weight of total mix) prepared in Drum Type
Hot Mix Plant of 60-90 TPH capacity.
cum
16.56 Providing and laying semi- dense Bituminous concrete using crushed stone
aggregates of specified grading, premixed with bituminous binder and filler, transporting
the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor
to the required grade, level and alignment and rolling with smooth wheeled, vibratory and
tandem rollers to achieve the desired compaction and density as per specification,
complete and as per directions of Engineer-in- Charge.
10013.30
9930.95
7756.40
7678.10
249.40
16.56.2 25 mm compacted thickness with bitumen of grade VG-
30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared
in Drum Type Hot Mix Plant of 60-90 TPH capacity. sqm 247.35
16.57 Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with
electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers
to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
cum
16.57.2 40/50 mm compacted thickness with bitumen of grade VG-30 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) and waste plastic additive @ 8% (percentage by weight
of bitumen) prepared in Batch Type Hot Mix Plant of 100- 120 TPH capacity.
cum
16.57.3 40/50 mm compacted thickness with bitumen of grade PMB-40 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH
capacity.
cum
16.57.4 40/50 mm compacted thickness with bitumen of grade CRMB-60 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH
capacity.
cum
16.57.5 40/50 mm compacted thickness with bitumen of grade VG-30 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
16.57.6 40/50 mm compacted thickness with bitumen of grade VG-30 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) and waste plastic additive @ 8% (percentage by weight
of bitumen) prepared in drum Type Hot Mix Plant of 60-90 TPH capacity.
cum
16.57.7 40/50 mm compacted thickness with bitumen of grade PMB-40 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
gregate) prepared
10870.75
11399.20
9969.20
9310.40
10786.70
11315.15
9885.15
16.57.8 40/50 mm compacted thickness with bitumen of grade
CRMB-60 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate)
prepared in Drum Type Hot Mix Plant of 60-90 TPH
capacity. cum 9226.35
16.59 Manufacturing, supplying and fixing retro reflective sign boards made
up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated
type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in
blue and silver white or other colour combination including subject matter, message (bi-
lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an
adhesive backing which shall be activated by applying heat and pressure conforming to
class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets
@ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft
resistant measures, mounted and fixed with 2 Nos.
M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT
50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and
including making holes in pipes, angles flats, providing & fixing M.S. message plate of
required size, steel work to be painted with two or more coats of synthetic enamel paint of
required shade and of approved brand & manufacture over priming coat of zinc chromate
yellow primer (vertical MS-Tee support to be painted in black and white
colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint
over and including appropriate priming coat including all leads and lifts etc. complete as
per drawing , specification and direction of Engineer-in-charge.
each
16.60 Manufacturing, supplying and fixing retro reflective overhead signage boards
made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and
encapsulated lens type heat activated retro reflective sheeting conforming to type - III of
ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC
: 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted
on substrate by pressure sensitive adhesive backing which shall be activated by applying
pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of
structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @
300 mm centre to centre all along the periphery as well as in two vertical rows along with
theft resistant measures, including the cost of painting with two or more coats of epoxy
paint in grey colour on the back side of aluminium sheet including appropriate priming coat.
The rate includes the cost of rounding off the corners, lowering down the structural frame
work
from the gantry, fixing and erecting the same in position all complete
ntage by weight of Aggregate)
5745.95
4209.20
as per drawings, specification and direction of the engineer-in-
charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only
shall be measured for payment).
16.60.1 Overhead informatory road signage sqm 5609.55
each
16.62 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of
specified shade/ colour using hot thermoplastic material by fully/ semi automatic
thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,
propane tank heater and profile shoe heater, driven by experienced operator on road
surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals,
oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and
accordance with applicable specifications.
sqm
16.63 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with
cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm
nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed
and consolidated and grouted with fine sand, including finishing the top smooth etc.
complete and as per direction of Engineer-in-charge.
sqm
16.64 Providing and laying 75 mm thick compacted bed of dry brick aggregate
of 40 mm thick nominal size including spreading, well ramming, consolidating and
grouting with jamuna sand, including finishing smooth etc. complete as per direction of
Engineer- in- charge.
sqm
16.65 Providing and fixing post delineators made of ABS round body fitted with 2 nos
100 mm dia high reflective reflectors and mounted on MS pipe of 65 mm dia duly powder
coated anti-rust and anti theft steel to be installed as per direction of Engineer-in-charge.
each
16.66 Excavating holes upto 0.10 cum, including getting out the excavated soil, then
returning the soil as deported in layers not exceeding 20 cm in depth, including
consolidating and deposited layer by ramming watering etc., disposing of surplus
excavated soil as directed with in a lead of 50 mm and lift upto 1.5 m.
5609.55
6281.60
623.80
529.80
196.30
781.40
29.95
16.67 Providing and fixing at or near ground level factory made RCC
pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm
dia M.S. bars 4 nos on each side, including setting in position in footpath to the required
level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse
sand), having joint thickness not more than 5mm except on curve, including filling of joints
with same cement mortar and making grooves etc. complete as per direction of Engineer-
in-charge.
sqm 1371.20
16.68 Providing and laying 60mm thick faciory made cement concrete interlocking
paver block of M -30 grade made by block making machine with strong vibratory
compaction, of approved size, design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all
complete as per the direction of Engineer-in-charge.
sqm 951.00
16.69 Providing and laying at or near ground level factory made kerb stone of M-25
grade cement concrete in position to the required line, level and curvature, jointed with
cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to more than 5mm), including
making drainage opening wherever required complete etc. as per direction of Engineer-in-
charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb
stone shall be approved by Engineer-in-charge).
cum 8613.55
16.70 Providing and fixing G.I. chain link fabric fencing of required width in mesh size
50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as
required complete as per the direction of Engineer-in-charge.
16.71 Providing and fixing G.I. chain link fabric fencing of required width in mesh size
25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire
or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
sqm 971.90
16.72 Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.
cum 1060.80
16.73 Dry stone pitching 22.5 cm thick laid in courses and required profile with
hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm
including preparing the bedding surface etc. all complete. (Payment for Stone to be made
separately).
sqm 542.85
16.74 75 mm thick back filling for pitching including supplying of required materials
and consolidation etc. complete with :
16.74.1 Moorum sqm 82.00
16.74.2 Stone aggregate 20 mm nominal size sqm 175.85
16.74.3 Stone aggregate 40 mm nominal size sqm 167.25
16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete from batching plant. The ready mixed concrete shall be laid and finished with
screed board vibrator , vacuum dewatering process and finally finished by floating,
brooming with wire brush etc. complete as per specifications and directions of Engineer-in-
charge. (The panel shuttering work shall be paid for separately).
cum 8277.55
16.76 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in
C.C. pavement. cum 191.10
sqm 5.85
16.78 Construction of granular sub-base by providing close graded Material
conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed
material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified
thickness with motor grader on prepared surface and compacting with vibratory power
roller to achieve the desired density, complete as per specifications and directions of
Engineer-in-Charge.
16.79 Providing, laying, spreading and compacting graded stone aggregate (size
range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing
the material with water at OMC in for all leads & lifts, laying in uniform layers with
mechanical paverfinisher in sub- base / base course on well prepared surface and
compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density,
complete as per specifications and directions of Engineer-in-Charge.
cum 2803.65
16.80 Construction of dry lean cement concrete sub base over a prepared sub-grade
with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not
exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after
blending to be as per specifications, cement content not to be less than 150 Kg/cum,
optimum moisture content to be determined during trial length construction, concrete
strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to
site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory
roller, finishing and curing etc. complete as per direction of Engineer- in- charge.
cum 4130.55
16.81 Providing and erecting 2.00 metre high temporary barricading at site;
each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow
MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The
sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be
made so that gap of 50cm above the ground is available making overall height as 2.5m.
MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval
shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm
bracing. Suitable arrangement shall be made to fix the barricading to avoid from
overturning by providing 250mm long expansion fasteners at both ends. The work shall be
executed as per drawing/direction of Engineer-in-Charge which includes writing and
painting, arrangement for traffic diversion such as traffic signals during construction at site
for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by
the Engineer-in-Charge. The barricading provided shall be retained in position at site
continuously i/c shifting of barricading from one location to another location as many
times as required during the execution of the entire work till its completion. Rate include its
maintenance for damages, painting, all incidentals, labour materials, equipments and
works required to execute the job. The barricading shall not be removed without prior
approval of Engineer- in-Charge.
(Note :- One time payment shall be made for providing barricading from start of
work till completion of work i/c shifting. The barricading provided shall remain to
be the property of the contractor on completion of the work).
metre 2827.40
16.82 Taking out existing kerb stones of all types from footpath/ central verge,
including removal of mortar etc., disposal of unserviceable material to the dumping ground,
for which payment shall be made separately and stacking of serviceable material within 50
metre lead as per direction of Engineer-in-Charge.
metre 32.40
16.83 Taking out existing CC interlocking paver blocks from footpath/ central verge,
including removal of rubbish etc., disposal of unserviceable material to the dumping
ground, for which payment shall be made separately and stacking of serviceable material
within 50 metre lead as per direction of Engineer-in-Charge.
sqm 108.65
16.84 Laying old cement cocrete interlocking paver blocks of any design/ shape laid
in required line, level, curvature, colour and pattern over and including 50 mm thick
compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the
direction of Engineer- in-charge. (Old CC paver blocks shall be supplied by the department
free of cost).
sqm 362.30
16.85 Laying at or near ground level old kerb stones of all types in position
to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3
coarse sand), including making joints with or without grooves (thickness of joints, except at
sharp curve, shall not be more than 5 mm), including making drainage opening wherever
required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb
edging shall be measured for payment). (Old kerb stones shall be supplied by the
department free of cost)
metre 90.85
16.86 Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded
and pre polished machine cut granite stone of required size and shape of approved shade,
colour and texture in footpath, flooring cut granite stone of required size and shape of
approved shade, colour and texture in footpath, flooring in road side plazas and similar
locations, laid over 20mm thick base of cement mortar 1:4 (1cement
: 4 coarse sand) including grouting the joints with white cement mixed with matching
pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.
16.86.1 With granite stone of area less than 0.50 sqm. sqm 4115.80
16.87 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded
and pre polished machine cut granite stone of required size and shape of approved shade,
colour and texture in footpath, flooring in road side plazas and similar locations, laid over
20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the
joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as
per direction of Engineer-in-Charge.
16.87.1 With granite stone of colour black, cherry/ruby red of area less than
0.50 sqm. sqm 4256.30
16.87.2 With granite stone of all colour except black, cherry/ruby red of area
less than 0.50 sqm. sqm 4537.25
16.88 Providing and laying matt finished vitrified tile of size 100x100x16mm having
water absorption less than 0.5% and conforming to IS: 15622 of approved make in all
colours and shades in out door floors such as footpath, court yard multi models etc., laid
on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes &
patterns including grouting the joints with white cement mixed with matching pigments etc.
complete as direction of Engineer-in-Charge.
sqm 1866.20
16.89 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having
with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all
colours and shades in for outdoor floors such as footpath, court yard, multi modals location
etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all
shapes & patterns including grouting the joints with white cement mixed with matching
pigments etc. complete as per direction of Engineer-in-Charge.
sqm 1250.75
16.90 Providing and laying tactile tile (for vision impaired persons as per
standards) of size 300x300x9.8mm having with water absorption less than 0.5% and
conforming to IS:15622 of approved make in all colours and shades in for outdoor floors
such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement
mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints
with white cement mixed with matching pigments etc. complete as per direction of
Engineer-in-Charge.
sqm 1719.00
16.91 Providing and laying factory made chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,
thickness & size/ shape, made by table vibratory method using PU mould, laid in required
colour & pattern over 50mm thick compacted bed of sand, compacting and proper
embedding/laying of inter locking paver blocks into the sand bedding layer through
vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver
blocks as per required size and pattern, finishing and sweeping extra sand. complete all as
per direction of Engineer-in-Charge.
16.91.1 60mm thick cement concrete paver block of M-35 grade with
approved colour, design & pattern. sqm 932.35
16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color
design and pattern. sqm 1011.20
16.92 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel
dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1
cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled
pointing etc. complete as per direction of engineer-in-charge.
sqm 1871.80
16.93 Providing and placing in position 100 mm thick factory made machine batched
& machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes,
of M-25 grade cement concrete for RCC work, including cost of centering, shuttering,
reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both
ways , neat cement punning on finished surface, properly encased on all edges with
1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be
welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost
of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-
Charge.
sqm 2617.15
16.94 Providing & making Gabion structure with Mechanically Woven Double Twisted
Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500,
of required size, Mesh Type 10x12 (D=100 mm with tolerance of ± 2%) Zinc coated, Mesh
wire diameter
3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have
minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with
lacing wire of diameter 2.2mm, supplied @ 3% by weight of Gabion boxes, filled with
boulders with least dimension of 200 mm, as per drawing, all complete as per
direction of Engineer-in-charge.
cum 3727.70
16.95 Providing & making Gabion structure with Mechanically Woven Double
Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH
Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ± 2%)
Zinic+PVC coated, Mesh wire diameter2.7/3.7mm, mechanically edged/selvedged with
partitions at every 1m interval and shall have minimum 10 numbers of openings per meter
of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD),
supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200
mm, as per drawing, all complete as per directions of Engineer-in- charge.
cum 3857.20
16.96 Providing & making Gabion structure with Mechanically Woven Double Twisted
Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500,
of required size, Mesh Type 10x12(D=100 mm with tolerance of ±2%), Zinic+10% Al
alloy+PVC coated, Mesh wire diameter 2.7/3.7mm (ID/OD), mechanically edged/
selvedged with partitions at every 1m interval and shall have minimum 10 numbers of
openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter
2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with
least dimension of 200 mm, as per drawing, all complete as per directions of Engineer- in-
charge.
cum 4151.55
SUB HEAD : 17.0
SANITARY INSTALLATIONS
345
1371.20
951.00
8613.55
859.50
901.65
971.90
1060.80
542.85
82.00
175.85
167.25
8277.55
191.10
5.85
2658.10
2775.65
2612.95
2803.65
4130.55
2827.40
32.40
108.65
362.30
90.85
4115.80
4256.30
4537.25
1866.20
1250.75
1719.00
932.35
1011.20
1871.80
2617.15
3727.70
3857.20
4151.55
BASIC RATES (17.0 SANITARY INSTALLATIONS)
Code No. Description Unit
1533 Flush pipe with union spreaders and clamps all in C.P. brass for double stall
each
1534 Flush pipe with union spreaders and clamps all in C.P. brass for range of
three stall each
1535 Flush pipe with union spreaders and clamps all in C.P. brass for range of four
stall each
1540 Flush pipe and spreaders G.l. for single set of one squatting plate urinal
each
1541 Flush pipe and spreaders G.l. for range of two squatting plates urinal
each
1542 Flush pipe and spreaders G.l. for range of three squatting plates urinal
each
1543 Flush pipe and spreaders G.l. for range of four squatting plates urinal
each
1617 S.C.I. soil, waste and vent single socketed pipe 1.80 metres long:100 mm dia
each
1656 Sand cast iron S&S single unequal junctions: 100x100x75 mm dia with access
door each
1659 Sand cast iron S&S plain double unequal junctions: 100x100x75x 75 mm dia
each
1662 Sand cast iron S&S double unequal junctions: 100x100x75x75 mm dia with
access door each
1672 S.C.I. double equal invert branch of required degree 75x75x75x 75 mm dia
each
1673 S.C.I. double equal invert branch of required degree 100x100x100x 100 mm
dia each
1674 S.C.I. single unequal invert branch of required degree 100x100x 75 mm dia
each
1677 S.C.I. double unequal invert branch of required degree 100x100x 75x75 mm
dia each
1893 C.I. trap for standard urinal with vent arm with operating and other couplings
in C.P. brass: 80 mm dia each
3621 C.C.I. (spun) socketed soil, waste and vent pipe 1.80 metres long:75 mm dia
each
3624 S.C.I. S&S bends with access door 100 mm dia each
3625 S.C.I. S&S bends with access door 75 mm dia each
3628 S.C.I. S&S bend 100 mm dia each
3629 S.C.I. S&S bend 75 mm dia each
3634 S.C.I. S&S heel rest sanitary bend 100 mm dia each
3635 S.C.I. S&S heel rest sanitary bend 75 mm dia each
3640 S.C.I. S&S single equal junctions 100x100x100 mm each
3641 S.C.I. S&S single equal junctions 75x75x75 mm each
3644 S.C.I. S&S single equal junctions with access door 100x100x 100 mm
each
3645 S.C.I. S&S single equal junctions with access door 75x75x75 mm each
3650 S.C.I. S&S double equal junctions 100x100x100x100 mm each
3655 S.C.I. S&S double equal junctions with access door 75x75x75x
75 mm each
3681 S.C.I. S&S single equal invert branch of required degree 100x100x 100 mm
dia each
3682 S.C.I. S&S single equal invert branch of required degree 75x75x 75 mm dia
each
3685 S.C.I. S&S double equal invert branch of required degree 100x100x 100x100
mm dia each
3686 S.C.I. S&S double equal invert branch of required degree 75x75x 75x75 mm
dia each
3690 S.C.I. S&S single unequal invert branch of required degree 100x 100x75 mm
dia each
3695 S.C.I. S&S double unequal invert branch of required degree 100x 100x75x75
mm dia each
7095 Stainless steel kitchen sink - with drain board 510x1040 mm bowl depth 250
mm each
7096 Stainless steel kitchen sink - with drain board 510 x 1040 mm bowl depth 225
mm each
7097 Stainless steel kitchen sink - with drain board 510 x 1040 mm bowl depth 200
mm each
7098 Stainless steel kitchen sink - with drain board 510x1040 mm bowl depth 178
mm each
7101 Stainless steel kitchen sink - without drain board 610x510 mm bowl depth 200
mm each
7102 Stainless steel kitchen sink - without drain board 610x460 mm bowl depth 200
mm each
7103 Stainless steel kitchen sink - without drain board 470x420 mm bowl depth 178
mm each
7115 Rectangular shape 1500x450 mm Mirror with Plastic moulded frame each
7116 Hard board 6 mm thick sqm
7117 Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not
less than 700 mm i/c PVC waste fittings each
7118 Semi Rigid PVC waste pipe for sink and wash basin 40 mm dia with length not
less than 700 mm i/c PVC waste fittings each
Rate
714.00
714.00
714.00
714.00
645.00
645.00
784.00
714.00
784.00
714.00
714.00
714.00
1400.00
1350.00
5000.00
290.00
180.00
100.00
165.00
1500.00
4950.00
88.00
200.00
40.00
67.50
30.00
27.00
35.00
37.00
30.00
100.00
25.00
16.00
18.00
450.00
950.00
210.00
310.00
425.00
525.00
610.00
190.00
275.00
310.00
450.00
70.00
1050.00
1135.00
210.00
280.00
290.00
350.00
315.00
405.00
390.00
455.00
410.00
615.00
525.00
730.00
215.00
265.00
525.00
575.00
625.00
725.00
300.00
355.00
350.00
435.00
425.00
550.00
500.00
600.00
285.00
485.00
180.00
270.00
1300.00
1500.00
2500.00
410.00
325.00
55.00
270.00
280.00
190.00
225.00
315.00
325.00
300.00
220.00
470.00
1053.00
725.00
725.00
425.00
85.00
100.00
475.00
1290.00
1025.00
2500.00
9800.00
103.00
163.93
163.93
145.72
145.72
1100.00
300.00
550.00
210.00
1170.00
1150.00
400.00
300.00
300.00
200.00
300.00
280.00
500.00
350.00
500.00
390.00
630.00
470.00
630.00
500.00
600.00
650.00
800.00
900.00
430.00
330.00
540.00
450.00
550.00
730.00
230.00
300.00
400.00
310.00
390.00
360.00
460.00
410.00
300.00
300.00
210.00
300.00
180.00
220.00
360.00
110.00
120.00
280.00
700.00
1200.00
22.00
5500.00
1600.00
9000.00
2200.00
4500.00
3000.00
3500.00
3200.00
3000.00
2200.00
1500.00
1200.00
1600.00
850.00
1000.00
350.00
400.00
290.00
290.00
670.00
115.00
25.00
33.00
7119 Flexible (coil shaped) PVC waste pipe for sink and wash basin
32mm dia with length not less than 700 mm i/c PVC waste fittings each
7120 Flexible (coil shaped) PVC waste pipe for sink and wash basin
40 mm dia with length not less than 700 mm i/c PVC waste fittings each
7126 White Vitreous china 10 litre (full flush) capacity controlled low level flushing
cistern with all fittings each
7127 Coloured Vitreous china 10 litre (full flush) capacity controlled low level flushing
cistern with all fittings each
7358 Flushing Cistern P.V.C. 10 litre capacity (low level) (White) (with fittings,
accessories and flush pipe) each
7375 G.I. flush pipe and C.P. brass spreader including C.P. connecting pipe Single
lipped urinal each
7376 G.I. flush pipe and C.P. brass spreader including C.P. connecting pipe Range of
two lipped urinals each
7377 G.i. flush pipe and C.P. brass spreader including C.P. connecting pipe Range of
three lipped urinals each
7378 G.I. flush pipe and C.P. brass spreader including C.P. connecting pipe Range of
four lipped urinals each
7379 White vitreous china clay half stall urinal flat back 580x380x350 mm or angle
back 450x375x350 mm with waste fittings as per IS:2556 each
7623 Hubless centrifugally cast (spun) iron plain bend as per IS 15905 - 100mm
dia each
7624 Hubless centrifugally cast (spun) iron plain bend as per IS 15905 - 75 mm dia
each
7625 Hubless centrifugally cast (spun) iron double equal plain junction as per IS
15905 - 100x100x100x100 mm dia each
7626 Hubless centrifugally cast (spun) iron double equal plain junction as per IS
15905 - 75x75x75x75 mm dia each
7627 Hubless centrifugally cast (spun) iron single equal plain junction as per IS
15905 - 100x100x100 mm dia each
7628 Hubless centrifugally cast (spun) iron single equal plain junction as per IS
15905 - 75x75x75 mm dia each
7629 Hubless centrifugally cast (spun) iron double unequal plain junction as per IS
15905 - 100x100x75x75 mm dia each
7630 Hubless centrifugally cast (spun) iron single unequal plain junction as per IS
15905 -100x100x75 mm dia each
7631 Hubless centrifugally cast (spun) iron double equal plain invert branch as per
IS 15905 - 100x100x100x100 mm dia each
7632 Hubless centrifugally cast (spun) iron single equal plain invert branch as per
IS 15905 - 100x100x100 mm dia each
7633 Hubless centrifugally cast (spun) iron single equal plain invert branch as per
IS 15905 - 75x75x75 mm dia each
7634 Hubless centrifugally cast (spun) iron single unequal plain invert branch 45
degree as per IS 15905 - 100x100x75 mm dia each
7635 Hubless centrifugally cast (spun) iron 65 mm offset with 100 mm dia pipe as
per IS 15905 each
7636 Hubless centrifugally cast (spun) iron 65 mm offset with 75 mm dia pipe as
per IS 15905 each
7637 Hubless centrifugally cast (spun) iron 130 mm offset with 100 mm dia pipe as
per IS 15905 each
7638 Hubless centrifugally cast (spun) iron 130 mm offset with 75 mm dia pipe as
per IS 15905 each
7639 Hubless centrifugally cast (spun) iron bend with access door - 100mm dia as
per IS 15905 each
7640 Hubless centrifugally cast (spun) iron bend with access door - 75mm dia as
per IS 15905 each
7641 Hubless centrifugally cast (spun) iron terminal guard (slotted cowl) - 100 mm
dia as per IS 15905 each
7642 Hubless centrifugally cast (spun) iron trap with 100 mm inlet and 100 mm
outlet as per IS 15905 each
7643 Hubless centrifugally cast (spun) iron trap with 100 mm inlet and
75 mm outlet as per IS 15905 each
7644 SS 304 grade shielded coupling with EPDM rubber gasket for 100mm dia
Hubless centrifugally cast (spun) iron each
7645 SS 304 grade shielded coupling with EPDM rubber gasket for 75 mm dia
Hubless centrifugally cast (spun) iron each
7805 Salem Stainless steel AISI - 304 (18/8) Orrisa pattern W.C. pan 724mm X
578 mm each
7806 Salem Stainless steel AISI - 304 (18/8) Round basin 405mm X 355 mm
each
7807 Salem Stainless steel AISI - 304 (18/8) Wash basin 530mm X 345 mm
each
7808 Centrifugally cast (spun) iron S&S 100 mm inlet and 100 mm outlet each
7809 Centrifugally cast (spun) iron S&S 100 mm inlet and 75 mm outlet each
7858 P.T.M.T. Urinal cock 15 mm dia each
9001 C.P. Brass Centre Hole Basin Mixer With Cast Spout each
9977 Carriage L.S.
9988 Carriage and sundries L.S.
9999 Sundries L.S.
35.00
35.00
620.00
4500.00
550.00
700.00
1150.00
575.00
450.00
500.00
430.00
500.00
240.00
445.00
765.00
1050.00
1430.00
865.00
115.00
34.00
39.00
200.00
200.00
95.00
110.00
125.00
145.00
150.00
55.00
700.00
570.00
230.00
160.00
510.00
275.00
400.00
215.00
400.00
375.00
625.00
390.00
260.00
430.00
360.00
295.00
440.00
310.00
365.00
290.00
270.00
540.00
385.00
275.00
250.00
4500.00
1500.00
2000.00
450.00
500.00
95.00
1600.00
2.12
2.12
2.12
17.0 SANITARY INSTALLATIONS
Code No. Description Unit
17.1 Providing and fixing water closet squatting pan (Indian type W.C.
pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm
with integral type foot rests each
each
17.2 Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid each
17.2.2 W.C. pan with ISI marked black solid plastic seat and lid each
17.3 Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous
china flushing cistern & C.P. flush bend with fittings & C.I. brackets,
40 mm flush bend, overflow arrangement with specials of standard
make and mosquito proof coupling of approved municipal design
complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid each
17.3.2 W.C. pan with ISI marked black solid plastic seat and lid each
17.4 Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps
complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :
17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern
each
17.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic
flushing cistern each
17.4.3 Range of three urinal basins with 10litre white P.V.C. automatic
flushing cistern each
17.4.4 Range of four urinal basins with 10 litre white P.V.C. automatic
flushing cistern each
Rate
5781.35
10076.15
5540.55
5426.80
6941.30
6827.55
5268.85
8115.55
11256.40
15564.35
17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC
automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P.
brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of
fittings and cutting and making good the walls and floors wherever required :
17.5.2 Range of two half stall urinals with 5 litre P.V.C. automatic flushing
cistern each
17.5.3 Range of three half stall urinals with 10 litre P.V.C. automatic
flushing cistern each
17.5.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing
cistern each
17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal
flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front
flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings
and cutting and making good the walls and floors etc. wherever required :
17.6.2 Range of two squatting plates with 5 litre P.V.C. automatic flushing
cistern each
17.6.4 Range of four squatting plates with 10 litre P.V.C. automatic flushing
cistern each
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of
standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15
mm C.P. brass pillar tap each
17.7.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15
mm C.P. brass pillar taps each
17.7.4 White Vitreous China Flat back wash basin size 550x 400 mm with
single 15 mm C.P. brass pillar tap each
17.7.5 White Vitreous China Angle back wash basin size 600 x 480 mm
with single 15mm C.P. brass pillar tap each
350 mm with white PVC
ons and clamps (all in C.P.
P. brass, including painting of
10128.30
15115.40
18546.45
21880.95
h an integral longitudinal
sh pipe for back and front
, including painting of fittings
7752.60
11281.10
14817.35
17784.35
3392.85
2965.60
3158.70
2731.45
2965.60
17.7.6 White Vitreous China Angle back wash basin size 400 x
400 mm with single 15 mm C.P. brass pillar tap each
17.7.7 White Vitreous China Flat back wash basin size 450x 300 mm with
single 15mm C.P. brass pillar tap each
17.7.8 White Vitreous China Surgeon type wash basin of size 660x460 mm
with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
each
17.7.9 White Vitreous China Surgeon type wash basin of size 660x460 mm
with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked
each
17.7.10 Stainless Steel AISI-304(18/8) Round basin 405x355 mm with
single 15 mm C.P. brass pillar tap each
17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP
Brass single hole basin mixer of approved quality and make, including
painting of fittings and brackets, cutting and making good the walls
wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP
Brass single hole basin mixer each
17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT
pillar cock, 32 mm PTMT waste coupling of standard pattern, including
painting of fittings and brackets, cutting and making good the walls
wherever required. White Vitreous China Flat back wash basin size 550x400
mm with single 15 mm PTMT pillar cock. each
17.8 Providing and fixing white vitreous china pedestal for wash basin completely
recessed at the back for the reception of pipes and fittings.
each
17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain
with rubber plug, 40 mm C.P. brass waste complete, including painting
the fittings and brackets, cutting and making good the walls wherever
required:
17.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm each
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as
per IS:13983 with C.I. brackets and stainless steel plug 40 mm,
including painting of fittings and brackets, cutting and making good
the walls wherever required :
17.10.1 Kitchen sink with drain board
17.10.1.1 510x1040 mm bowl depth 250 mm each
17.10.1.2 510x1040 mm bowl depth 225 mm each
17.10.1.3 510x1040 mm bowl depth 200 mm each
17.10.1.4 510x1040 mm bowl depth 178 mm each
2564.20
2370.20
4322.70
3681.40
4002.50
4671.45
4542.40
2521.85
1500.05
3302.95
6008.45
6677.40
6276.00
6008.45
17.10.2 Kitchen sink without drain board
17.10.2.1 610x510 mm bowl depth 200 mm each
17.10.2.2 610x460 mm bowl depth 200 mm each
17.10.2.3 470x420 mm bowl depth 178 mm each
17.11 Providing and fixing white vitreous china laboratory sink with C.I.
brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste
and 40mm C.P. brass trap with necessary C.P. brass unions complete,
including painting of fittings and brackets, cutting and making good
the wall wherever required :
17.11.1 Size 450x300x150 mm each
17.11.2 Size 600x450x200 mm each
17.12 Providing and fixing draining board with C.I. brackets including painting
of brackets, cutting and making good the walls wherever required :
17.12.1 White glazed fire clay draining board of size 600x450x 25 mm
each
17.13 Providing and fixing white vitreous china water closet squatting pan
(Indian type) :
17.13.1 Long pattern W.C. pan of size 580 mm each
17.13.2 Orissa pattern W.C. pan of size 580x440 mm each
17.14 Extra for using coloured W.C. pan instead of white W.C. pan :
17.14.1 Orissa pattern W.C. pan 580x440 mm each
17.15 Providing and fixing white vitreous china pedestal type (European type/ wash
down type) water closet pan. each
17.16 Extra for using coloured pedestal type W.C pan (European type)
with low level cistern of same colour instead of white vitreous china
W.C pan and cistern. each
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto
1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and
make as approved by Engineer - in - charge. each
17.17 Providing and fixing a pair of white vitreous china foot rests of standard
pattern for squatting pan water closet :
17.17.1 250x130x30 mm pair
17.17.2 250x125x25 mm pair
17.18 Providing and fixing P.V.C. low level flushing cistern with manually
controlled device (handle lever) conforming to IS : 7231, with all fittings
and fixtures complete.
17.18.1 10 litre capacity - White each
17.18.2 10 litre capacity - coloured each
4274.40
3337.85
2936.45
4272.95
5610.85
1351.65
1667.80
2758.20
414.75
2403.65
167.25
299.35
219.60
223.60
1023.05
989.60
17.19 Providing and fixing controlled flush, low level cistern made of vitreous
china with all fittings complete.
17.19.1 10 litre (full flush) capacity-white each
17.19.2 10 litre (full flush) capacity-coloured each
17.20 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan
complete :
17.20.1 White solid plastic seat with lid each
17.20.2 Black solid plastic seat with lid each
17.20.3 Coloured (other than black & white) solid plastic seat with lid
each
17.22 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C.
pan. each
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality &
make and as per the direction of Engineer-in-charge. each
17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality &
make as approved by Engineer in charge.
(a) 15 mm nominal dia each
17.23 Providing and fixing white vitreous china flat back or wall corner type lipped
front urinal basin of 430x260x350 mm or 340x410x265 mm sizes
respectively.
each
17.24 Providing and fixing white vitreous china squatting plate urinal with integral
rim longitudinal flush pipe. each
17.25 Providing and fixing white vitreous china wash basin including making all
connections but excluding the cost of fittings :
17.25.1 Flat back wash basin of size 630x450 mm each
17.25.2 Flat back wash basin of size 550x400 mm each
17.25.3 Angle back wash basin of size 600x480 mm each
17.25.4 Angle back wash basin of size 400x400 mm each
17.25.5 Flat back wash basin of size 450x300 mm each
17.25.6 Surgeon type wash basin of size 660x460 mm each
17.26 Providing and fixing kitchen sink including making all connections excluding
cost of fittings.
17.26.1 White glazed fire clay sink of size 600x450x250 mm each
17.27 Providing and fixing white vitreous china laboratory sink including making all
connections excluding cost of fittings :
17.27.1 Size 450x300x150 mm each
17.27.2 Size 600x450x200 mm each
1930.85
2532.95
586.55
472.80
506.25
131.65
886.25
6119.15
1382.30
3389.35
1149.60
915.45
1149.60
748.20
554.20
1651.30
1884.60
2152.20
3490.15
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
17.32 Providing and fixing mirror of superior glass (of approved quality) and
of required shape and size with plastic moulded frame of approved
make and shade with 6 mm thick hard board backing :
17.32.1 Circular shape 450 mm dia each
17.32.2 Rectangular shape 453x357 mm each
17.32.3 Oval shape 450x350 mm (outer dimensions) each
17.32.4 Rectangular shape 1500x450 mm each
17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off,
supported on anodised aluminium angle frame with C.P. brass
brackets and guard rail complete fixed with 40 mm long screws, rawl plugs
etc., complete. each
metre
90.95
101.65
104.35
104.35
45.25
45.30
1411.15
1248.60
1158.95
1157.40
1817.20
942.15
680.80
463.00
1018.05
1077.40
1061.25
17.35.2 75 mm diameter :
17.35.2.1 Sand cast iron S&S pipe as per IS: 1729 metre
17.35.2.2 Centrifugally cast (spun) iron socketed pipe as per IS:
3989 metre
each
17.38.2 75 mm dia
17.38.2.1 Sand cast iron S&S as per IS - 1729 each
17.38.2.2 Sand cast iron S&S as per IS- 3989 each
17.38.2.3 Hubless centrifugally cast (spun) iron epoxy coated
inside & outside as per IS:15905
each
17.39 Providing and fixing plain bend of required degree.
17.39.1 100 mm dia
17.39.1.1 Sand cast iron S&S as per IS - 1729 each
17.39.1.2 Sand cast iron S&S as per IS : 3989 each
17.39.1.3 Hubless centrifugally cast (spun) iron pipes epoxy
coated inside & outside IS:15905
each
931.55
1042.10
867.55
138.70
163.45
308.45
304.45
530.70
597.60
550.80
440.00
453.40
440.00
412.95
439.75
346.05
17.39.2 75 mm dia
17.39.2.1 Sand cast iron S&S as per IS -1729 each
17.39.2.2 Sand cast iron S&S as per IS - 3989 each
17.39.2.3 Hubless centrifugally cast (spun) iron pipes
epoxy coated inside & outside
IS:15905
each
Providing and fixing heel rest sanitary bend
17.40.1 100 mm dia
each
75x75x75x75 mm
17.42.2.1 Sand cast iron S&S as per IS - 1729 each
each
17.42.2
311.55
298.20
244.70
513.30
439.75
432.00
405.25
1038.75
904.95
754.45
721.00
861.20
881.25
720.70
579.15
659.45
398.55
17.43 Providing and fixing single equal plain junction of required degree
with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
17.43.1 100x100x100 mm
17.43.1.1 Sand cast iron S&S as per IS - 1729 each
17.43.1.2 Sand cast iron S&S as per IS - 3989 each
17.43.2 75x75x75 mm
17.43.2.1 Sand cast iron S&S as per IS - 1729 each
17.43.2.2 Sand cast iron S&S as per IS - 3989 each
17.44 Providing and fixing single equal plain junction of required degree :
17.44.1 100x100x100 mm
17.44.1.1 Sand cast iron S&S as per IS - 1729 each
17.44.1.2 Sand cast iron S&S as per IS - 3989 each
17.44.1.3 Hubless centrifugally cast (spun) iron epoxy coated
inside & outside as per IS:15905
each
17.44.2 75x75x75 mm
17.44.2.1 Sand cast iron S&S as per IS - 1729 each
17.44.2.2 Sand cast iron S&S as per IS - 3989 each
17.44.2.3 Hubless centrifugally cast (spun) iron epoxy coated
inside & outside as per IS:15905
each
17.45 Providing and fixing double unequal junction of required degree with access
door, insertion rubber washer 3 mm thick, bolts and nuts complete:
17.45.1 100x100x75x75 mm
17.45.1.1 Sand cast iron S&S as per IS - 1729 each
17.45.1.2 Sand cast iron S&S as per IS - 3989 each
17.46 Providing and fixing double unequal plain junction of required degree :
17.46.1 100x100x75x75 mm
17.46.1.1 Sand cast iron S&S as per IS - 1729 each
17.46.1.2 Sand cast iron S&S as per IS - 3989 each
17.46.1.3 Hubless centrifugally cast (spun) iron epoxy coated
inside & outside as per IS:15905
each
17.47 Providing and fixing single unequal junction of required degree with access
door, insertion rubber washer 3 mm thick, bolts and nuts complete :
17.47.1 100x100x75 mm
17.47.1.1 Sand cast iron S&S as per IS - 1729 each
17.47.1.2 Sand cast iron S&S as per IS - 3989 each
671.20
731.40
573.80
573.80
580.20
707.30
573.50
452.05
498.90
318.25
1032.45
1266.60
874.55
1108.70
573.50
831.75
932.10
17.48 Providing and fixing single unequal plain junction of required degree :
17.48.1 100x100x75 mm
17.48.1.1 Sand cast iron S&S as per IS - 1729 each
17.48.1.2 Sand cast iron S&S as per IS - 3989 each
17.48.1.3 Hubless centrifugally cast (spun) iron
epoxy coated inside & outside as per IS:15905
each
17.49 Providing and fixing double equal plain invert branch of required degree:
17.49.1 100x100x100x100 mm
17.49.1.1 Sand cast iron S&S as per IS - 1729 each
17.49.1.2 Sand cast iron S&S as per IS 3989 each
17.49.1.3 Hubless centrifugally cast (spun) iron epoxy coated
inside & outside as per
IS:15905
each
75x75x75x75 mm
17.49.2.1 Sand cast iron S&S as per IS - 1729 each
540.10
774.20
760.85
874.55
599.25
632.70
620.35
613.65
560.15
498.90
472.10
378.45
841.10
1015.05
17.52 Providing and fixing single unequal plain invert branch of required
degree :
17.52.1 100x100x75 mm
each
17.53 Providing and fixing sand cast iron S&S off sets as per IS: 1729
613.65
324.95
512.25
453.10
560.15
532.55
666.35
512.25
425.30
338.35
447.10
580.90
627.05
445.35
711.35
611.00
17.55.2 75 mm
17.55.2.1 Sand cast iron S&S as per IS - 1729 each 433.30
17.55.2.2 Sand cast iron S&S as per IS - 3989 each 453.40
17.56 Providing and fixing terminal guard :
17.56.1 100 mm
17.56.1.1 Sand cast iron S&S as per IS - 1729 each
17.56.1.2 Sand cast iron S&S as per IS - 3989 each
17.56.1.3 Hubless centrifugally cast (spun) iron epoxy
coated inside & outside as per IS:15905
each
17.56.2 75 mm
17.56.2.1 Sand cast iron S&S as per IS - 1729 each
17.56.2.2 Sand cast iron S&S as per IS - 3989 each
Providing and fixing collar :
17.57.1 100 mm
17.57A.2 75 mm dia
17.57A.2.1 SS 304 grade coupling with EPDM rubber
gasket each 365.10
17.58 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :
17.58.1 100 mm each 549.65
17.58.2 75 mm each 466.40
17.58.3 50 mm each 376.85
17.59 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of
diameter :
399.60
318.25
311.55
399.60
439.75
271.45
271.45
128.65
80.10
73.75
17.60 Providing and fixing trap of self cleansing design with screwed down
or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
17.60.1 100 mm inlet and 100 mm outlet
each
17.60.2 100 mm inlet and 75 mm outlet
17.60.2.1 Sand cast iron S&S as per IS - 3989 each
17.60.2.2 Sand Cast Iron S&S as per IS- 1729 each
17.60.2.3 Hubless centrifugally cast (spun) iron epoxy
coated inside & outside as per IS:15905
each
17.61 Cutting chases in brick masonry walls for following diameter sand
cast iron/centrifugally cast (spun) iron pipes and making good the
same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6
graded stone aggregate 12.5 mm nominal size), including necessary
plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse
sand) :
17.61.1 100 mm dia metre
17.61.2 75 mm dia metre
17.61.3 50 mm dia metre
17.62 Painting C.I. cistern with bitumastic or any other anti-corrosive paint
inside and white paint over a coat of zinc chromate yellow primer (of
approved quality ) on the outside surface of the cistern, flush pipe, other
fittings, etc. complete for new work. each
17.64 Repainting C.I. cistern with synthetic enamel paint of approved colour,
brand and manufacture on the outside surface of cistern, flush pipe, other
fittings etc. complete. each
17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste
vent pipes and fittings with two coats of synthetic enamel paint of
any colour such as chocolate grey, or buff etc. over a coat of primer
(of approved quality) for new work :
17.65.1 100 mm diameter pipe metre
17.65.2 75 mm diameter pipe metre
d the walls and floors :
1604.10
1403.45
760.85
1671.00
1296.40
553.45
615.70
442.20
287.50
844.70
560.65
244.00
69.55
52.90
17.66 Repainting sand cast iron/ centrifugally cast iron (spun) iron, soil,
waste, vent pipes and fittings with one coat of synthetic enamel paint of any colour such as
chocolate, grey or buff etc :
17.66.1 100 mm diameter pipe metre
17.66.2 75 mm diameter pipe metre
17.67 Repainting bath tub of size 1700x730x430 mm with enamel paint. each
17.68 Providing and fixing vitreous china dual purpose closet suitable for use as
squatting pan or European type water closet (Anglo Indian
W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level
flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with
specials of standard make and mosquito proof coupling of approved municipal design
complete, including painting of fittings and brackets, cutting and making good the walls and
floors wherever required:
17.68.1 White vitreous china dual purpose WC pan with white solid plastic
seat and lid with white vitreous china flushing cistern and C.P. flush bend. each
17.69 Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour.
17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste coupling, 77
mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
each
17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste coupling, 77
mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
each
17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high
and 112 mm distance from wall of standard shape with bracket of the same materials with
snap fittings of approved quality and colour, weighing not less than 105 gms.
each
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm
wide with minimum distances of 37 mm from wall face with concealed fittings arrangement
of approved quality and colour,
weighing not less than 88 gms.
each
33.40
25.00
684.45
10326.65
103.00
109.70
325.10
325.10
146.30
204.70
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
17.73.1 450 mm long towel rail with total length of 495 mm,
78 mm wide and effective height of 88 mm, weighing not less than 170 gms each
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 gms.
each
17.74 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36
mm height of approved quality and colour, weighing not less than 300 gms.
each
17.76 Providing and fixing PTMT urinal cock of approved quality and colour.
17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with
BSP female threads weighing not less than 48 gms
each
17.77 Providing and fixing M.S. holder bat clamp of approved design to
sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets
made of 50x5 mm flat of specified shape, projecting 75 mm outside
the wall surface and fixed on wall with 4nos, 6mm dia expansion
hold fasteners, including drilling necessary holes in brick wall/ CC/
RCC surface and the cost of bolts etc. The pipes shall be fixed to the
already fixed brackets with the help of 30 mm x1.6 mm galvanised
M.S. flats of specified shape and of total length 420 mm and shall be
fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts
on each side of the pipe.
17.77.1 Total bracket length 580 mm of approved shape and design (for single
100 mm dia pipe) each
17.77.2 Total bracket length 810 mm of approved shape and design (for two
100 mm dia pipes) each
17.77.3 Total bracket length 1040 mm of approved shape and design (for three
100 mm dia pipes) each
17.78 Providing and fixing white vitreous china extended wall mounting
water closet of size 780x370x690 mm of approved shape including
providing & fixing white vitreous china cistern with dual flush fitting,
of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),
including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
each
17.79 Providing & fixing white vitreous china water less urinal of size 600 x
330 x 315 mm having antibacterial /germs free ceramic surface,
fixed with cartridge having debris catcher and hygiene seal. each
ality and colour.
573.60
600.35
607.05
92.75
149.95
247.95
306.90
365.65
13036.55
15968.65
17.80 Providing and fixing white vitreous china battery based infrared sensor
operated urinal of approx. size 610 x 390 x 370 mm having pre &
post flushing with water (250 ml & 500 ml consumption), having
water inlet from back side, including fixing to wall with suitable
brackets all as per manufacturers specification and direction of Engineer-in-
charge. each 7004.45
17.81 Providing and fixing floor mounted, white vitreous china single piece,
double traps syphonic water closet of approved brand/make, shape,
size and pattern including integrated white vitreous china cistern of
capacity 10 litres with dual flushing system, including all fittings and
fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc
including making connection with the existing P/S trap, complete in
all respect as per directions of Engineer-in-Charge. each 16100.40
SUB HEAD : 18.0
WATER SUPPLY
373
7004.45
16100.40
BASIC RATES (SH: 18.0 WATER SUPPLY)
Code No. Description Unit
2319 Carriage of Spun iron S & S pipes 100 mm dia 100 metre
2320 Carriage of Spun iron S & S pipes 125 mm dia 100 metre
2321 Carriage of Spun iron S & S pipes 150 mm dia 100 metre
2322 Carriage of Spun iron S & S pipes 200 mm dia 100 metre
2323 Carriage of Spun iron S & S pipes 250 mm dia 100 metre
2324 Carriage of Spun iron S & S pipes 300 mm dia 100 metre
2325 Carriage of Spun iron S & S pipes 350 mm dia 100 metre
2326 Carriage of Spun iron S & S pipes 400 mm dia 100 metre
2327 Carriage of Spun iron S & S pipes 450 mm dia 100 metre
2328 Carriage of Spun iron S & S pipes 500 mm dia 100 metre
2329 Carriage of Spun iron S & S pipes 600mm dia 100 metre
2330 Carriage of C.I. pipes 500 mm dia 100 metre
2331 Carriage of R.C.C. pipes 900 mm dia 100 metre
2332 Carriage of R.C.C. pipes 1000 mm dia 100 metre
2333 Carriage of R.C.C. pipes 1100 mm dia 100 metre
2334 Carriage of R.C.C. pipes 1200 mm dia 100 metre
2335 Carriage of sand cum
2341 Carriage of Pig lead tonne
2343 Carriage of Ductile Iron pipes (k7) 100 mm dia 100 metre
2344 Carriage of Cast iron pipes 150 mm dia 100 metre
2345 Carriage of Cast iron pipes 200 mm dia 100 metre
2346 Carriage of Cast iron pipes 250 mm dia 100 metre
2347 Carriage of Cast iron pipes 300 mm dia 100 metre
2348 Carriage of Cast iron pipes 350 mm dia 100 metre
2349 Carriage of Cast iron pipes 400 mm dia 100 metre
2350 Carriage of Cast iron pipes 450 mm dia 100 metre
2351 Carriage of Cast iron pipes 500 mm dia 100 metre
2352 Carriage of Cast iron pipes 600 mm dia 100 metre
2353 Carriage of Cast iron pipes 700 mm dia 100 metre
2355 Carriage of Cast iron pipes 800 mm dia 100 metre
2356 Carriage of Cast iron pipes 900 mm dia 100 metre
2357 Carriage of Cast iron pipes 1000 mm dia 100 metre
3080 Gunmetal non-return valve - vertical (screwed end) 25 mm dia each
3084 Gunmetal non-return valve - vertical (screwed end) 32 mm dia each
3088 Gunmetal non-return valve - vertical (screwed end) 40 mm dia each
3092 Gunmetal non-return valve - vertical (screwed end) 50 mm dia each
3863 SS pipe 316L grade as per IS 6911:2017 with press fit technology and
conforming to EN-10312 standard 22 mm outer dia metre
3864 SS pipe 316L grade as per IS 6911:2017 with press fit technology and
conforming to EN-10312 standard 28 mm outer dia metre
3865 SS pipe 316L grade as per IS 6911:2017 with press fit technology and
conforming to EN-10312 standard 35 mm outer dia metre
3866 SS pipe 316L grade as per IS 6911:2017 with press fit technology and
conforming to EN-10312 standard 42 mm outer dia metre
3867 SS pipe 316L grade as per IS 6911:2017 with press fit technology and
conforming to EN-10312 standard 54 mm outer dia metre
3868 Coupling/Socket fittings for 15 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3869 Coupling/Socket fittings for 22 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3870 Coupling/Socket fittings for 28 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3871 Coupling/Socket fittings for 35 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3872 Coupling/Socket fittings for 42 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3873 Coupling/Socket fittings for 54 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
800.00
750.00
645.00
645.00
784.00
714.00
784.00
714.00
40.00
500.00
50.00
1800.00
125.00
210.00
250.00
210.00
225.00
210.00
225.00
140.00
160.00
220.00
16.00
18.00
20.00
20.00
25.00
40.00
45.00
50.00
73.00
92.00
110.00
125.00
210.00
3800.00
3800.00
5700.00
5250.00
340.00
95.00
130.00
196.00
225.00
290.00
360.00
415.00
525.00
18.00
25.00
65.00
452.00
35.00
55.00
115.00
145.00
230.00
310.00
525.00
575.00
6.10
30.00
35.00
35.00
48.00
700.00
110.00
125.00
55.00
625.00
215.00
240.00
230.00
325.00
375.00
415.00
500.00
625.00
1080.00
1625.00
350.00
475.00
575.00
840.00
1525.00
2300.00
2450.00
2610.00
3650.00
7600.00
10980.00
15500.00
11.50
13.00
15.00
17.50
17.00
17.00
27.00
31.00
37.00
145.72
145.72
145.72
358.32
478.64
597.20
971.45
1380.48
1706.30
2388.82
3257.48
3981.36
3981.36
5972.04
3981.36
8958.06
11944.08
11944.08
11944.08
163.93
145.72
358.32
597.20
971.45
1380.48
1706.30
2388.82
3257.48
3981.36
3981.36
5972.04
5972.04
5972.04
8958.06
11944.08
400.00
550.00
750.00
950.00
1550.00
2600.00
2700.00
3300.00
4100.00
8900.00
15000.00
18500.00
6000.00
310.00
500.00
650.00
945.00
1160.00
1500.00
215.00
270.00
315.00
395.00
535.00
640.00
255.00
375.00
310.00
3877 Reducer for 35 mm X 22 mm outer Dia SS pipe of grade 316L
as per IS 6911:2017 and conforming to EN-10312 standard each
3885 Sleeve/Slip Coupling / Socket 15 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3886 Sleeve/Slip Coupling / Socket 22 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3887 Sleeve/Slip Coupling / Socket 28 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3888 Sleeve/Slip Coupling / Socket 35 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3889 Sleeve/Slip Coupling / Socket 42 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3890 Sleeve/Slip Coupling / Socket 54 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3891 Elbow 90° for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3892 Elbow 90° for 22 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3893 Elbow 90° for 28 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3894 Elbow 90° for 35 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3895 Elbow 90° for 42 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3896 Elbow 90° for 54 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3897 Equal Tee for 15 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3898 Equal Tee for 22 mm outer dia SS pipe of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3899 Equal Tee for 28 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3900 Equal Tee for 35 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3901 Equal Tee for 42 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3902 Equal Tee for 54 mm outer dia SS pipe of grade 316L as per IS 6911:2017
and conforming to EN-10312 standard each
3903 Reducing Tee for 22 mm X 15 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3904 Reducing Tee for 28 mm X 15 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3905 Reducing Tee for 28 mm X 22 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3906 Reducing Tee for 35 mm X 15 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3907 Reducing Tee for 35 mm X 22 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3908 Reducing Tee for 35 mm X 28 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3909 Reducing Tee for 42 mm X 22 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3910 Reducing Tee for 42 mm X 28 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3911 Reducing Tee for 42 mm X 35 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3912 Reducing Tee for 54 mm X 22 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3913 Reducing Tee for 54 mm X 28 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3914 Reducing Tee for 54 mm X 35 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3915 Reducing Tee for 54 mm X 42 mm outer dia SS pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3916 Stainless steel Female thread Tee for 15 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3917 Stainless steel Female thread Tee for 22 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3918 Stainless steel Female thread Tee for 22 mm outer dia X 3/4"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to
EN-10312 standard
each
3919 Stainless steel Female thread Tee for 28 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3920 Stainless steel Female thread Tee for 28 mm outer dia X 3/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3921 Stainless steel Female thread Tee for 28 mm outer dia X 1" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3922 Stainless steel Female thread Tee for 35 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3923 Stainless steel Female thread Tee for 35 mm outer dia X 1-1/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3924 Stainless steel Female thread Tee for 42 mm outer dia X 1-1/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3925 Stainless steel Female thread Tee for 54 mm outer dia X 1-1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3926 Stainless steel Female thread Tee for 54 mm outer dia X 2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3927 Stainless steel Female threaded Connector/Adapter for 15 mm outer dia X
1/2" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3928 Stainless steel Female threaded Connector/Adapter for 22 mm outer dia X
1/2" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3929 Stainless steel Female threaded Connector/Adapter for 22 mm outer dia X
3/4" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3930 Stainless steel Female threaded Connector/Adapter for 28 mm outer dia X 1"
nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3931 Stainless steel Female threaded Connector/Adapter for 35 mm outer dia X 1-
1/4" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3932 Stainless steel Female threaded Connector/Adapter for 42 mm outer dia X 1-
1/2" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3933 Stainless steel Female threaded Connector/Adapter for 54 mm
outer dia X 2" nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard each
3934 Stainless steel Male threaded Connector/ Adapter for 15 mm outer dia X 1/2"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3935 Stainless steel Male threaded Connector/ Adapter for 22 mm outer dia X 1/2"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3936 Stainless steel Male threaded Connector/ Adapter for 22 mm outer dia X 3/4"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3937 Stainless steel Male threaded Connector/ Adapter for 28 mm outer dia X 1"
nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
3938 Stainless steel Male threaded Connector/ Adapter for 35 mm outer dia X 1-1/4"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3939 Stainless steel Male threaded Connector/ Adapter for 42 mm outer dia X 1-1/2"
nominal dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3940 Stainless steel Male threaded Connector/ Adapter for 54 mm outer dia X 2"
nominal dia threaded of grade 316L as per
IS 6911:2017 and conforming to EN-10312 standard
each
Female Threaded Elbow 90°
3941 SS Female Threaded Elbow 90° for 15 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3942 SS Female Threaded Elbow 90° for 22 mm outer dia X 3/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3943 SS Female Threaded Elbow 90° for 28 mm outer dia X 1" nominal dia threaded
of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3944 SS Female Threaded Elbow 90° for 35 mm outer dia X 1-1/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3945 SS Female Threaded Elbow 90° for 42 mm outer dia X 1-1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3946 SS Female Threaded Elbow 90° for 54 mm outer dia X 2" nominal dia threaded
of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3947 SS Male Threaded Elbow 90° for 15 mm outer dia X 1/2" nominal
dia threaded of grade 316L as per IS 6911:2017 and conforming to EN-
10312 standard
each
3948 SS Male Threaded Elbow 90° for 22 mm outer dia X 3/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3949 SS Male Threaded Elbow 90° for 28 mm outer dia X 1" nominal dia threaded
of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3950 SS Male Threaded Elbow 90° for 35 mm outer dia X 1-1/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3951 SS Male Threaded Elbow 90° for 42 mm outer dia X 1-1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3952 SS Male Threaded Elbow 90° for 54 mm outer dia X 2" nominal dia threaded
of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3953 Stainless steel Cap for 15 mm outer dia pipe of grade 316L as per S
I 6911:2017 and conforming to EN-10312 standard each
3954 Stainless steel Cap for 22 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3955 Stainless steel Cap for 28 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3956 Stainless steel Cap for 35 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3957 Stainless steel Cap for 42 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3958 Stainless steel Cap for 54 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3959 Stainless steel Pipe Bridge for 15 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3960 Stainless steel Pipe Bridge for 22 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3961 Stainless steel Pipe Bridge for 28 mm outer dia pipe of grade 316L as per IS
6911:2017 and conforming to EN-10312 standard each
3962 SS Male Union for 15 mm outer dia X 1/2" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3963 SS Male Union for 22 mm outer dia X 1/2" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3964 SS Male Union for 22 mm outer dia X 3/4" nominal dia threaded of
grade 316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3965 SS Male Union for 28 mm outer dia X 1" nominal dia threaded of grade 316L
as per IS 6911:2017 and conforming to EN-10312 standard
each
3966 SS Male Union for 35 mm outer dia X 1-1/4" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3967 SS Male Union for 42 mm outer dia X 1-1/2" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3968 SS Male Union for 54 mm outer dia X 2" nominal dia threaded of grade 316L
as per IS 6911:2017 and conforming to EN-10312 standard
each
3969 SS Female Union for 22 mm outer dia X 3/4" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3970 SS Female Union for 28 mm outer dia X 1" nominal dia threaded of grade
316L as per IS 6911:2017 and conforming to EN-10312 standard
each
3971 SS Female Transition Elbow/ FTE for 15 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3972 SS Female Transition Elbow/ FTE for 22 mm outer dia X 1/2" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
3973 SS Female Transition Elbow/ FTE for 22 mm outer dia X 3/4" nominal dia
threaded of grade 316L as per IS 6911:2017 and conforming to EN-10312
standard
each
6501 Sand zone V (Jamuna) cum
7257 C.P. Brass bibcock 15 mm each
7258 C.P. Brass long nose bibcock 15 mm each
7259 C.P. Brass long body bibcock 15 mm each
7260 C.P. Brass stop cock (concealed) 15 mm each
7261 C.P. Brass angle valve 15 mm each
7400 15 mm PTMT bib cock each
7401 15 mm PTMT bib cock with flange (fancy) each
7402 15 mm PTMT bib cock long body with flange each
7403 15 mm dia PTMT stop cock (male thread) each
7405 20 mm dia PTMT stop cock each
380.00
470.00
690.00
720.00
605.00
990.00
1030.00
835.00
375.00
450.00
520.00
580.00
670.00
955.00
305.00
430.00
575.00
940.00
1520.00
2010.00
500.00
585.00
720.00
895.00
1250.00
1500.00
575.00
715.00
710.00
900.00
905.00
915.00
1280.00
1265.00
1290.00
1570.00
1540.00
1550.00
1500.00
560.00
615.00
690.00
730.00
755.00
840.00
845.00
1159.00
1346.00
1920.00
2307.00
440.00
495.00
580.00
955.00
1020.00
1565.00
2400.00
405.00
480.00
505.00
665.00
970.00
1415.00
1895.00
640.00
860.00
1180.00
1917.00
2088.00
3227.00
525.00
790.00
1045.00
1440.00
2635.00
2998.00
320.00
415.00
515.00
720.00
1565.00
1720.00
415.00
1110.00
1526.00
885.00
895.00
1025.00
1805.00
1885.00
2130.00
3680.00
950.00
1280.00
649.00
900.00
870.00
1300.00
300.00
500.00
500.00
420.00
350.00
65.00
90.00
100.00
60.00
68.00
7406 PTMT pillar cock each
7496 PTMT Ball Cock 20mm complete with Epoxy Coated Aluminium Rod & H.D.
Ball each
7497 PTMT Ball Cock 25mm complete with Epoxy Coated Aluminium Rod & H.D.
Ball each
7498 PTMT Ball Cock 40mm complete with Epoxy Coated Aluminium Rod & H.D.
Ball each
7499 PTMT Ball Cock 50mm complete with Epoxy Coated Aluminium Rod & H.D.
Ball each
7657 Ductile Iron class K - 9 pipe Conforming to 1.S. 8329 - 400 mm dia metre
7658 Ductile Iron class K - 9 pipe Conforming to 1.S. 8329 - 450 mm dia metre
7659 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 500 mm dia metre
7660 Ductile Iron class K -9 pipe Conforming to I.S. 8329 - 600 mm dia metre
7661 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 700 mm dia metre
7662 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 750 mm dia metre
7663 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 800 mm dia metre
7664 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 900 mm dia metre
7665 Ductile Iron class K - 9 pipe Conforming to I.S. 8329 - 1000 mm dia metre
7666 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 100 mm dia each
7668 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 150 mm dia each
7669 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 200 mm dia each
7670 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 250 mm dia each
7671 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 300 mm dia each
7672 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 350 mm dia each
7673 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 400 mm dia each
7674 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 450 mm dia each
7675 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 500 mm dia each
7676 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 600 mm dia each
7677 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 700 mm dia each
7678 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 750 mm dia each
7679 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 800 mm dia each
7680 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 900 mm dia each
7681 Rubber Gaskets Conforming to I.S 5382 of S.B.R quality 1000 mm dia each
7682 Ductile Iron K - 12 specials suitable for push on jointing up to 600 mm dia
quintal
7683 Ductile Iron K - 12 specials suitable for push on jointing over 600 mm dia
quintal
7686 Ductile Iron Pipe Class K-9 flanges and welding 100 mm dia metre
7687 Ductile Iron Pipe Class K-9 flanges and welding 150 mm dia metre
7688 Ductile Iron Pipe Class K-9 flanges and welding 200 mm dia metre
7689 Ductile Iron Pipe Class K-9 flanges and welding 250 mm dia metre
7690 Ductile Iron Pipe Class K-9 flanges and welding 300 mm dia metre
7691 Ductile Iron Pipe Class K-9 flanges and welding 350 mm dia metre
7692 Ductile Iron Pipe Class K-9 flanges and welding 400 mm dia metre
7693 Ductile Iron Pipe Class K-9 flanges and welding 450 mm dia metre
7694 Ductile Iron Pipe Class K-9 flanges and welding 500 mm dia metre
7695 Ductile Iron Pipe Class K-9 flanges and welding 600 mm dia metre
7696 Ductile Iron Pipe Class K-9 flanges and welding 700 mm dia metre
7697 S&S Centrifugally (Spun) C.I. Pipe class LA 100 mm dia metre
7698 S&S Centrifugally (Spun) C.I. Pipe class LA 125 mm dia metre
7699 S&S Centrifugally (Spun) C.I. Pipe class LA 150 mm dia metre
7700 S&S Centrifugally (Spun) C.I. Pipe class LA 200 mm dia metre
7701 S&S Centrifugally (Spun) C.I. Pipe class LA 250 mm dia metre
7702 S&S Centrifugally (Spun) C.I. Pipe class LA 300 mm dia metre
7703 S&S Centrifugally (Spun) C.I. Pipe class LA 350 mm dia metre
7704 S&S Centrifugally (Spun) C.I. Pipe class LA 400 mm dia metre
7705 S&S Centrifugally (Spun) C.I. Pipe class LA 450 mm dia metre
7706 S&S Centrifugally (Spun) C.I. Pipe class LA 500 mm dia metre
7707 S&S Centrifugally (Spun) C.I. Pipe class LA 600 mm dia metre
7708 S&S Centrifugally (Spun) C.I. Pipe Specials as per IS 1538 suitable for lead
jointing up to 300 mm dia quintal
7709 S&S Centrifugally (Spun) C.I. Pipe Specials as per IS 1538 suitable for lead
jointing over 300 mm dia quintal
7710 S&S Centrifugally (Spun) C.I. Pipe specials suitable for mechanical joint as
per I.S. 13382 up to 300 mm dia quintal
7711 S&S Centrifugally (Spun) C.I. Pipe Specials suitable for mechanical joint as
per I.S. 13382 over 300 mm dia quintal
7712 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 100 mm dia metre
7713 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 150 mm dia metre
7714 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 200 mm dia metre
7715 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 250 mm dia metre
7716 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 300 mm dia metre
7717 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 350 mm dia metre
7718 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 400 mm dia metre
7719 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 450 mm dia metre
7720 Screwed double flanged centrifugally cast (spun) C./. Pipe of Class B
conforming to I.S. 1536, - 500 mm dia metre
7721 Screwed double flanged centrifugally cast (spun) C.I. Pipe of Class B
conforming to I.S. 1536, - 600 mm dia metre
7722 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 100 mm dia metre
7723 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 150 mm dia metre
7724 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 200 mm dia metre
7725 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 250 mm dia metre
7726 Ductile Iron Class K- 7 pipe conforming to i.S. 8329 - 300 mm dia metre
7727 Ductile Iron Class K- 7 pipe conforming to i.S. 8329 - 350 mm dia metre
7728 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 400 mm dia metre
7729 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 450 mm dia metre
7730 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 500 mm dia metre
7731 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 600 mm dia metre
7732 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 700 mm dia metre
7733 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 800 mm dia metre
7734 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 900 mm dia metre
7735 Ductile Iron Class K- 7 pipe conforming to I.S. 8329 - 1000 mm dia metre
7859 P.T.M.T. Bib cock with nozzle 15 mm each
7861 P.T.M.T. Stop cock (concealed) 15 mm each
7862 15 mm nominal bore and 30 cm length PVC connection pipe with
P.T.M.T. Nuts each
8627 Poly propylene- Random - Co - Polymer (PPR) pipes PN-16 (SDR 7.4) - 25
mm Outer dia metre
8628 Poly propylene- Random - Co - Polymer (PPR) pipes PN-16 (SDR 7.4) - 32
mm Outer dia metre
8629 Poly propylene- Random - Co - Polymer (PPR) pipes PN-16 (SDR 7.4) - 40
mm Outer dia metre
8630 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 50
mm Outer dia metre
8631 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 63
mm Outer dia metre
8632 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 75
mm Outer dia metre
8633 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 90
mm Outer dia metre
8634 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 110
mm Outer dia metre
8635 Poly propylene- Random - Co - Polymer (PPR) pipes PN-10 (SDR 11) - 160
mm Outer dia metre
8779 SS pipe 304 grades with press fit technology as per JIS 3448 standard 15.88
mm outer dia metre
8780 SS pipe 304 grades with press fit technology as per JIS 3448 standard 22.22
mm outer dia metre
8781 SS pipe 304 grades with press fit technology as per JIS 3448 standard 28.58
mm outer dia metre
8782 SS pipe 304 grades with press fit technology as per JIS 3448 standard 34.00
mm outer dia metre
8783 SS pipe 304 grades with press fit technology as per JIS 3448 standard 42.70
mm outer dia metre
55.00
45.00
16.00
125.00
25.00
118.00
3715.00
4525.00
5910.00
2030.00
3143.00
4765.00
5145.00
2680.00
4370.00
5540.00
7860.00
75.00
110.00
275.00
420.00
820.00
85.00
65.00
58.00
765.00
1150.00
1575.00
2200.00
2750.00
3350.00
4300.00
5000.00
6270.00
7560.00
10500.00
11350.00
11450.00
13900.00
15550.00
29.00
33.00
60.00
70.00
100.00
116.00
210.00
250.00
270.00
356.00
510.00
600.00
705.00
910.00
1080.00
12400.00
17200.00
13050.00
18750.00
1100.00
1650.00
2075.00
2950.00
3790.00
4780.00
6150.00
6453.00
9180.00
12150.00
14370.00
857.00
1067.00
1286.00
2190.00
2857.00
3857.00
4619.00
6095.00
7381.00
8571.00
11995.00
5190.00
6200.00
8571.00
9048.00
1310.00
2048.00
3238.00
3905.00
4990.00
6286.00
8143.00
10381.00
12914.00
17905.00
800.00
1140.00
1400.00
1800.00
2250.00
2650.00
3175.00
3852.00
4350.00
5600.00
7300.00
9100.00
11800.00
12300.00
110.00
120.00
38.00
52.00
25.00
50.00
68.00
80.00
90.00
140.00
180.00
280.00
360.00
60.00
110.00
150.00
220.00
410.00
550.00
1100.00
48.46
74.82
107.47
162.00
255.00
285.00
425.00
600.00
890.00
2575.00
49.00
80.00
127.97
165.00
230.00
375.25
793.30
1031.05
1466.75
3145.15
620.00
60.00
140.00
250.00
310.00
439.50
450.00
70.00
96.25
135.00
160.00
180.00
108.50
152.50
161.50
200.00
210.00
210.00
375.00
375.00
390.00
390.00
425.00
425.00
425.00
425.00
425.00
55.00
70.00
95.00
135.00
160.00
175.00
65.00
70.00
105.00
120.00
130.00
160.00
150.00
210.00
250.00
295.00
350.00
190.00
175.00
250.00
295.00
440.00
695.00
915.00
185.00
290.00
290.00
440.00
440.00
440.00
690.00
690.00
690.00
690.00
895.00
895.00
895.00
895.00
895.00
185.00
8846 Stainless steel Male thread Tee for 22.22 mm outer dia X 15 mm
nomina dia threaded each
8847 Stainless steel Male thread Tee for 22.22 mm outer dia X 20 mm nominal dia
threaded each
8848 Stainless steel Male thread Tee for 28.58 mm outer dia X 15 mm nomina dia
threaded each
8849 Stainless steel Male thread Tee for 28.58 mm outer dia X 20 mm nominal dia
threaded each
8850 Stainless steel Male thread Tee for 28.58 mm outer dia X 25 mm nominal dia
threaded each
8851 Stainless steel Male thread Tee for 34.00 mm outer dia X 15 mm nominal dia
threaded each
8852 Stainless steel Male thread Tee for 34.00 mm outer dia X 20 mm nominal dia
threaded each
8853 Stainless steel Male thread Tee for 34.00 mm outer dia X 25 mm nominal dia
threaded each
8854 Stainless steel Male thread Tee for 34.00 mm outer dia X 32 mm nominal dia
threaded each
8855 Stainless steel Male thread Tee for 42.70 mm outer dia X 15 mm nominal dia
threaded each
8856 Stainless steel Male thread Tee for 42.70 mm outer dia X 20 mm nominal dia
threaded each
8857 Stainless steel Male thread Tee for 42.70 mm outer dia X 25 mm nominal dia
threaded each
8858 Stainless steel Male thread Tee for 42.70 mm outer dia X 32 mm nominal dia
threaded each
8859 Stainless steel Male thread Tee for 42.70 mm outer dia X 40 mm nominal dia
threaded each
8860 Stainless steel Male thread Tee for 48.60 mm outer dia X 15 mm nominal dia
threaded each
8861 Stainless steel Male thread Tee for 48.60 mm outer dia X 20 mm nominal dia
threaded each
8862 Stainless steel Male thread Tee for 48.60 mm outer dia X 25 mm nominal dia
threaded each
8863 Stainless steel Male thread Tee for 48.60 mm outer dia X 32 mm nominal dia
threaded each
8864 Stainless steel Male thread Tee for 48.60 mm outer dia X 40 mm nominal dia
threaded each
8865 Stainless steel Male thread Tee for 48.60 mm outer dia X 50 mm nominal dia
threaded each
8866 Stainless steel Female thread Tee for 15.88 mm outer dia X 15 mm nominal
dia threaded each
8867 Stainless steel Female thread Tee for 22.22 mm outer dia X 15 mm
nominal dia threaded each
8868 Stainless steel Female thread Tee for 22.22 mm outer dia X 20 mm nominal
dia threaded each
8869 Stainless steel Female thread Tee for 28.58 mm outer dia X 15 mm nominal
dia threaded each
8870 Stainless steel Female thread Tee for 28.58 mm outer dia X 20 mm nominal
dia threaded each
8871 Stainless steel Female thread Tee for 28.58 mm outer dia X 25 mm nominal
dia threaded each
8872 Stainless steel Female thread Tee for 34.00 mm outer dia X 15 mm nominal
dia threaded each
8873 Stainless steel Female thread Tee for 34.00 mm outer dia X 20 mm nominal
dia threaded each
8874 Stainless steel Female thread Tee for 34.00 mm outer dia X 25 mm nominal
dia threaded each
8875 Stainless steel Female thread Tee for 34.00 mm outer dia X 32 mm nominal
dia threaded each
8876 Stainless steel Female thread Tee for 42.70 mm outer dia X 15 mm nominal
dia threaded each
8877 Stainless steel Female thread Tee for 42.70 mm outer dia X 20 mm nominal
dia threaded each
8878 Stainless steel Female thread Tee for 42.70 mm outer dia X 25 mm nominal
dia threaded each
8879 Stainless steel Female thread Tee for 42.70 mm outer dia X 32 mm nominal
dia threaded each
8880 Stainless steel Female thread Tee for 42.70 mm outer dia X 40 mm nominal
dia threaded each
8881 Stainless steel Female thread Tee for 48.60 mm outer dia X 15 mm nominal
dia threaded each
8882 Stainless steel Female thread Tee for 48.60 mm outer dia X 20 mm nominal
dia threaded each
8883 Stainless steel Female thread Tee for 48.60 mm outer dia X 25 mm nominal
dia threaded each
8884 Stainless steel Female thread Tee for 48.60 mm outer dia X 32 mm nominal
dia threaded each
8885 Stainless steel Female thread Tee for 48.60 mm outer dia X 40 mm nominal
dia threaded each
8886 Stainless steel Female thread Tee for 48.60 mm outer dia X 50 mm nominal
dia threaded each
8887 Stainless steel Female threaded Connector/Adapter for 15.88 mm outer dia X
15 mm nominal threaded each
8888 Stainless steel Female threaded Connector/Adapter for 22.22 mm
outer dia X 15 mm nominal threaded each
8889 Stainless steel Female threaded Connector/Adapter for 22.22 mm outer dia X
20 mm nominal threaded each
8890 Stainless steel Female threaded Connector/Adapter for 28.58 mm outer dia X
15 mm nominal threaded each
8891 Stainless steel Female threaded Connector/Adapter for 28.58 mm outer dia X
20 mm nominal threaded each
8892 Stainless steel Female threaded Connector/Adapter for 28.58 mm outer dia X
25 mm nominal threaded each
8893 Stainless steel Female threaded Connector/Adapter for 34.00 mm outer dia X
25 mm nominal threaded each
8894 Stainless steel Female threaded Connector/Adapter for 34.00 mm outer dia X
32 mm nominal threaded each
8895 Stainless steel Female threaded Connector/Adapter for 42.70 mm outer dia
X 32 mm nominal threaded each
8896 Stainless steel Female threaded Connector/Adapter for 42.70 mm outer dia
X 40 mm nominal threaded each
8897 Stainless steel Female threaded Connector/Adapter for 48.60 mm outer dia
X 40 mm nominal threaded each
8898 Stainless steel Female threaded Connector/Adapter for 48.60 mm outer dia X
50 mm nominal threaded each
8899 Stainless steel Male threaded Connector/Adapter for 15.88 mm outer dia X
15 mm nominal threaded each
8900 Stainless steel Male threaded Connector/Adapter for 22.22 mm outer dia X
15 mm nominal threaded each
8901 Stainless steel Male threaded Connector/Adapter for 22.22 mm outer dia X
20 mm nominal threaded each
8902 Stainless steel Male threaded Connector/Adapter for 28.58 mm outer dia X
20 mm nominal threaded each
8903 Stainless steel Male threaded Connector/Adapter for 28.58 mm outer dia X
25 mm nominal threaded each
8904 Stainless steel Male threaded Connector/Adapter for 34.00 mm outer dia X
25 mm nominal threaded each
8905 Stainless steel Male threaded Connector/Adapter for 34.00 mm outer dia X
32 mm nominal threaded each
8906 Stainless steel Male threaded Connector/Adapter for 42.70 mm outer dia X
32 mm nominal threaded each
8907 Stainless steel Male threaded Connector/Adapter for 42.70 mm outer dia X
40 mm nominal threaded each
8908 Stainless steel Male threaded Connector/Adapter for 48.60 mm outer dia X
40 mm nominal threaded each
8909 Stainless steel Male threaded Connector/Adapter for 48.60 mm
outer dia X 50 mm nominal threaded each
8910 Stainless steel Valve Connector for 15.88 mm outer dia X 15 mm nominal dia
threaded each
8911 Stainless steel Valve Connector for 22.22 mm outer dia X 15 mm nominal dia
threaded each
8912 Stainless steel Valve Connector for 22.22 mm outer dia X 20 mm nominal dia
threaded each
8913 Stainless steel Valve Connector for 28.58 mm outer dia X 25 mm nominal dia
threaded each
8914 Stainless steel Valve Connector for 34.00 mm outer dia X 32 mm nominal dia
threaded each
8915 Stainless steel Valve Connector for 42.70 mm outer dia X 40 mm nominal dia
threaded each
8916 Stainless steel Valve Connector for 48.60 mm outer dia X 50 mm nominal dia
threaded each
8917 SS Female Threaded Elbow 90o for 15.88 mm outer dia X 15 mm nominal
dia threaded each
8918 Stainless steel Female Threaded Elbow 90o for 22.22 mm outer dia X 15 mm
nominal dia threaded each
8919 Stainless steel Female Threaded Elbow 90o for 22.22 mm outer dia X 20 mm
nominal dia threaded each
8920 Stainless steel Female Threaded Elbow 90o for 28.58 mm outer dia X 25 mm
nominal dia threaded each
8921 Stainless steel Female Threaded Elbow 90o for 34.00 mm outer dia X 32 mm
nominal dia threaded each
8922 Stainless steel Female Threaded Elbow 90o for 42.70 mm outer dia X 32 mm
nominal dia threaded each
8923 Stainless steel Female Threaded Elbow 90o for 42.70 mm outer dia X40 mm
nominal dia threaded each
8924 Stainless steel Female Threaded Elbow 90o for 48.60 mm outer dia X 40 mm
nominal dia threaded each
8925 Stainless steel Female Threaded Elbow 90o for 48.60 mm outer dia X 50 mm
nominal dia threaded each
8926 Stainless steel Male Threaded Elbow 90o for 15.88 mm outer dia X15 mm
nominal dia threaded each
8927 Stainless steel Male Threaded Elbow 90o for 22.22 mm outer dia X15 mm
nominal dia threaded each
8928 Stainless steel Male Threaded Elbow 900 for 22.22 mm outer dia X20 mm
nominal dia threaded each
8929 Stainless steel Male Threaded Elbow 900 for 28.58 mm outer dia X25 mm
nominal dia threaded each
8930 Stainless steel MaleThreaded Elbow 900 for 34.00 mm outer dia X
25 mm nominal dia threaded each
8931 Stainless steel Male Threaded Elbow 900 for 34.00 mm outer dia X 32 mm
nominal dia threaded each
8932 Stainless steel Male Threaded Elbow 900 for 42.70 mm outer dia X 32 mm
nominal dia threaded each
8933 Stainless steel Male Threaded Elbow 900 for 42.70 mm outer dia X 40 mm
nominal dia threaded each
8934 Stainless steel Male Threaded Elbow 900 for 48.60 mm outer dia X 40 mm
nominal dia threaded each
8935 Stainless steel Male Threaded Elbow 900 for 48.60 mm outer dia X 50 mm
nominal dia threaded each
8936 Stainless steel Cap for 15.88 mm outer dia pipe each
8937 Stainless steel Cap for 22.22 mm outer dia pipe each
8938 Stainless steel Cap for 28.58 mm outer dia pipe each
8939 Stainless steel Cap for 34.00 mm outer dia pipe each
8940 Stainless steel Cap for 42.70 mm outer dia pipe each
8941 Stainless steel Cap for 48.60 mm outer dia pipe each
8942 Stainless steel Pipe Bridge for 15.88 mm outer dia pipe each
8943 Stainless steel Pipe Bridge for 22.22 mm outer dia pipe each
8944 Stainless steel Pipe Bridge for 28.58 mm outer dia pipe each
9977 Carriage L.S.
9988 Carriage and sundries L.S.
9999 Sundries L.S.
215.00
215.00
295.00
295.00
295.00
465.00
465.00
465.00
465.00
710.00
710.00
710.00
710.00
710.00
895.00
895.00
895.00
895.00
895.00
895.00
185.00
205.00
205.00
275.00
275.00
275.00
445.00
445.00
445.00
445.00
700.00
700.00
700.00
700.00
700.00
905.00
905.00
905.00
905.00
905.00
905.00
195.00
230.00
240.00
277.00
290.00
355.00
410.00
540.00
595.00
695.00
845.00
975.00
195.00
230.00
255.00
325.00
325.00
475.00
565.00
649.00
730.00
850.00
1140.00
235.00
280.00
310.00
425.00
645.00
880.00
1210.00
160.00
215.00
215.00
215.00
295.00
480.00
480.00
710.00
710.00
195.00
225.00
225.00
225.00
290.00
290.00
480.00
480.00
695.00
695.00
48.00
70.00
90.00
175.00
250.00
325.00
220.00
290.00
415.00
2.12
2.12
2.12
18.0 WATER SUPPLY
Code No. Description Unit
Concealed work, including cutting chases and making good the wall etc.
External work
18.3.1 1216 (16 mm OD) pipe metre
Rate
294.55
327.20
429.45
527.05
761.35
900.45
513.75
537.15
654.20
747.85
275.25
18.3.2 1620 (20 mm OD ) pipe metre
18.4 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes
confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal
stability for hot & cold water supply, including all PP - R plain & brass threaded
polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This
includes testing of joints complete as per direction of Engineer-in-Charge.
Concealed work,including cutting chases and making good the wall etc.
External work
18.6.1 PN - 16 Pipe, 20mm OD (SDR-7.4) metre
18.6.2 PN - 16 Pipe, 25 mm OD (SDR-7.4) metre
18.6.3 PN - 16 Pipe, 32 mm OD (SDR-7.4) metre
18.6.4 PN - 16 Pipe, 40 mm OD (SDR-7.4) metre
292.65
379.60
449.20
646.20
785.35
254.95
316.10
358.90
523.60
666.65
439.90
501.60
542.10
213.90
268.20
320.60
419.25
18.6.5 PN - 10 Pipe, 50 mm OD (SDR-11) metre
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply, including all CPVC plain & brass threaded
fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
654.65
879.45
1223.90
1689.50
4535.10
295.75
362.65
416.15
509.80
764.05
951.35
1687.20
255.90
325.10
408.55
500.95
674.35
927.00
441.15
513.75
626.05
712.75
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water
supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC
solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
External work
221.35
275.25
370.65
435.05
559.20
811.85
1576.90
1990.40
2811.75
5871.25
d making good the walls etc.
304.15
373.35
491.20
563.60
725.15
893.20
od the walls etc. concealed
e wall :
0
0
illing etc.
0
5
5
0
5
18.12.6 50 mm dia nominal bore metre
768.60
919.10
757.10
1513.70
670.15
303.85
327.95
303.85
327.95
532.35
461.75
589.90
707.30
878.25
1490.70
2227.60
348.85
397.45
399.15
18.19.2 32 mm nominal bore
18.19.2.1 Horizontal each
18.19.2.2 Vertical each
40 mm nominal bore
18.19.3.1 Horizontal each
18.21.1 30 cm length
18.21.1.1 15 mm nominal bore each
18.21.1.2 20 mm nominal bore each
18.21.2 45 cm length
18.21.2.1 15 mm nominal bore each
18.21.2.2 20 mm nominal bore each
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
18.22.1 100 mm diameter each
18.22.2 150 mm diameter each
C.I./DUCTILE IRON PIPES & SPECIALS
18.23 Laying in position centrifugally cast (spun) iron S&S or flanged pipes (excluding
cost of pipe). quintal
18.24 Laying in position S&S or flanged C.I. special such as tees, bends, collars,
tapers and caps etc.(excluding cost of specials). quintal
677.55
777.90
815.05
1049.20
1173.65
1320.80
2093.80
2127.25
3134.80
3536.15
g the main :
301.60
347.90
447.00
74.80
81.50
85.20
102.55
166.35
190.10
298.50
546.00
18.25 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class):
18.25.1 Up to 300 mm dia quintal 5649.65
18.25.2 Over 300 mm dia quintal 5649.65
18.26 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for
flanged jointing as per IS : 1538 :
18.26.1 Up to 300 mm dia quintal 8191.75
18.26.2 Over 300 mm dia quintal 7589.65
18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 :
5
5
g to IS - 1536 :
1210.50
1511.00
1824.70
3083.65
4030.50
5427.45
6519.65
8572.95
10380.20
12049.40
16832.90
410.25
609.45
615.75
818.35
1023.05
1230.65
1252.00
1648.10
1850.45
1956.30
2653.90
28116.20
18.30 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints :
182.85
284.75
303.50
343.55
377.00
520.30
527.00
662.00
907.60
1114.80
1264.60
1482.90
16.40
19.65
25.60
30.70
36.05
43.05
8.10
9.60
12.25
14.65
17.00
20.25
18.40 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
18.44 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for
tube well including cleaning and priming the tube well. metre
18.45 Providing and placing in position hand pump of approved quality for 40 mm
diameter G.I. pipe complete with all accessories. each
18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the
pipe and making long screws etc. complete (New work) :
10.05
12.00
15.25
18.40
20.95
25.25
31.30
36.40
s in external work :
157.70
159.85
164.10
168.35
170.50
176.90
279.20
287.70
304.75
453.95
618.00
730.95
847.35
813.25
499.80
1178.65
262.30
18.46.2 20 mm nominal bore each
369.35
409.45
523.20
706.70
994.35
1061.25
682.90
709.70
789.95
830.10
943.80
1280.30
1567.95
1634.85
9.70
9.70
434.20
715.05
708.40
594.75
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to
IS:8931
18.53.1 15mm nominal bore each 500.35
18.53A Providing and fixing C.P. Brass extension nipple (size 15mmx50mm)
of approved make and quality as per direction of Engineer-in-charge. each 61.70
PTMT FITTINGS
18.54 Providing and fixing PTMT bib cock of approved quality and colour.
18.54.2 15 mm nominal bore, 122mm long, weighing not less than 99 gms
each
18.54.3 15 mm nominal bore, 165 mm long, weighing not less than 110
gms each
18.55 Providing and fixing PTMT stop cock of approved quality and colour.
18.55.1 15 mm nominal bore, 86 mm long, weighing not less
than 88 gms each
Providing and fixing PTMT pillar cock of approved quality and colour.
18.56.1 15 mm nominal bore, 107 mm long, weighing not less than 110
gms each
18.56.2 15 mm nominal bore, 125 mm long foam flow, weighing not less
than 120 gms each
Providing and fixing PTMT, push cock of approved quality and colour.
18.57.1 15 mm nominal bore, 98 mm long, weighing not less than 75 gms
each
18.56
18.57
18.58 Providing and fixing PTMT grating of approved quality and colour.
18.58.1 Circular type
18.58.1.1 100 mm nominal dia each 33.20
18.58.1.2 125 mm nominal dia with 25 mm waste hole each 45.25
18.58.2 Rectangular type with openable circular lid
18.58.2.1 150 mm nominal size square 100 mm
diameter of the inner hinged round grating each 169.70
proved quality conforming to
70
109.85
143.30
156.65
170.05
103.15
113.85
183.40
180.80
194.15
96.45
83.05
AIR VALVE & WATER METER (BULK TYPE)
18.59 Providing and fixing C.I. double acting air valve of approved quality with bolts,
nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid
separately) :
18.62.1 15 mm nominal bore, 105 mm long, weighing not less than 138
gms each
18.62.2 20 mm nominal bore, 120 mm long, weighing not less than 198
gms each
18.62.3 25 mm nominal bore, 152mm long, weighing not less than 440 gms
each
18.62.4 40 mm nominal bore, 206mm long, weighing not less than 690 gms
each
18.62.5 50 mm nominal bore, 242mm long, weighing not less than 1240
gms each
18.63 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not
less than 85 gms each
18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing
not less than 40 gms each
18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm,
breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less
than 106 gms.
each
18.66 Providing and laying S&S C.I. Standard specials such as tees, bends, collars
tapers and caps etc, suitable for flanged jointing as per IS : 1538 :
3266.10
4995.90
7357.35
8080.15
4135.75
6637.55
8394.25
11712.65
161.55
223.50
459.40
653.40
1188.55
136.60
106.15
96.75
7509.40
8860.70
12032.95
12671.15
17155.90
23578.00
18025.60
25651.85
96.15
156.05
229.50
280.15
357.60
416.30
579.40
670.20
715.60
961.25
1256.80
1377.20
1577.35
1963.55
2265.60
18.71 Providing and laying Double Flanged (screwed / welded) Centrifugally
(Spun) Cast Iron, Class B (IS : 1536) :
18.71.1 100 mm dia C.I. Double Flanged Pipe metre
2880.00
4535.10
5498.05
7027.50
8847.60
11436.30
14544.15
18032.25
24977.15
o IS : 8329 :
1121.10
1601.30
1975.95
2544.05
3177.65
3774.50
4525.25
5479.85
6191.50
7986.05
10410.70
12982.00
16751.40
17655.80
1081.35
1625.05
2228.15
3105.20
3882.70
4752.05
6079.70
7074.20
8828.65
10698.20
18.72.25 700 mm dia Ductile Iron Class K-9 pipes metre
18.76.1 With common burnt clay F.P.S. (non modular) bricks each
18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe
etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including
finishing complete so as to make it leak proof.
each
18.78 Making chases up to 7.5x7.5 cm in walls including making good and finishing
with matching surface after housing G.I. pipe etc. metre
14750.95
16029.60
16276.50
19716.20
22099.60
e Iron Pipes of Class K - 9
1541.60
2312.90
2921.15
4142.70
5321.65
6700.15
8594.30
9068.45
12777.30
16929.85
20040.60
85.50
107.90
43.05
76.50
100.55
362.40
377.10
171.80
18.79 Making hole up to 20x20 cm and embedding pipes up to 150 mm
diameter in masonry and filling with cement concrete 1:3:6 (1 cement
: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of
malba.
metre
18.80 Disinfecting C.I. water mains by flushing with water containing bleaching
powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to
be repeated three times including getting the sample of water from the disinfected main
tested in the
municipal laboratory.
1523.95
1996.50
2486.60
2974.90
3954.45
4960.30
5501.75
6056.95
6635.25
7220.85
7834.30
9071.95
558.00
681.90
830.25
963.75
1451.60
1669.45
1873.85
2190.05
2508.80
2835.00
3163.20
3829.45
18.82 Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead
caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre:
327.30
340.80
353.40
366.20
407.80
448.10
484.50
519.10
550.80
583.30
611.90
662.15
119.90
160.70
222.85
301.90
402.65
500.85
601.60
699.75
800.15
898.70
999.10
1192.85
cock, having foam flow
8050.50
590.95
857.95
1069.10
1483.60
1786.05
2263.75
523.15
677.75
762.00
1028.95
18.87 Providing and fixing required Stainless Steel Fitting of press fit design
of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM
material of required dia as per direction of Engineer-in-charge.
Coupling/Socket
Coupling/Socket
18.87A.1 For 15 mm outer dia pipe each
18.87A.2 For 22 mm outer dia pipe each
18.87A.3 For 28 mm outer dia pipe each
18.87A.4 For 35 mm outer dia pipe each
18.87A.5 For 42 mm outer dia pipe each
18.87A.6 For 54 mm outer dia pipe each
18.88 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of providing and
fixing required Stainless Steel Fitting of press fit design of grade AISI 304
conforming to JWWA G116 standard with V-profile or M-profile and with O-
ring sealing gasket of EPDM material of required dia as per dirction of
Engineer-in-charge.
Reducer
18.88.1 For 22.22 mm x 15.88 mm outer dia pipe each
18.88.2 For 28.58 mm x 15.88 mm outer dia pipe each
18.88.3 For 28.58 mm x 22.22 mm outer dia pipe each
18.88.4 For 34.00 mm x 15.88 mm outer dia pipe each
18.88.5 For 34.00 mm x 22.22 mm outer dia pipe each
18.88.6 For 34.00 mm x 28.58 mm outer dia pipe each
18.88.7 For 42.70 mm x 15.88 mm outer dia pipe each
18.88.8 For 42.70 mm x 22.22 mm outer dia pipe each
18.88.9 For 42.70 mm x 28.58 mm outer dia pipe each
18.88.10 For 42.70 mm x 34.00 mm outer dia pipe each
ing sealing gasket of EPDM
80.30
93.65
128.80
180.60
214.05
240.85
287.65
361.25
421.45
528.50
715.80
856.30
145.15
204.05
216.10
267.60
280.95
280.95
501.75
501.75
521.80
521.80
18.88.11 For 48.60 mm x 15.88 mm outer dia pipe each
Reducer
18.88A.1 For 22mm x 15 mm outer dia pipe each
18.88A.2 For 28 mm x 15 mm outer dia pipe each
18.88A.3 For 28 mm x 22 mm outer dia pipe each
18.88A.4 For 35 mm x 22 mm outer dia pipe each
18.88A.5 For 35 mm x 28 mm outer dia pipe each
18.88A.6 For 42 mm x 22 mm outer dia pipe each
18.88A.7 For 42 mm x 28 mm outer dia pipe each
18.88A.8 For 42 mm x 35 mm outer dia pipe each
18.88A.9 For 54 mm x 28 mm outer dia pipe each
18.88A.10 For 54 mm x 35 mm outer dia pipe each
18.88A.11 For 54 mm x 42 mm outer dia pipe each
18.89 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
Slip Coupling/ Socket
18.89.1 For 15.88 mm outer dia pipe each
18.89.2 For 22.22 mm outer dia pipe each
18.89.3 For 28.58 mm outer dia pipe each
18.89.4 For 34.00 mm outer dia pipe each
18.89.5 For 42.70 mm outer dia pipe each
18.89.6 For 48.60 mm outer dia pipe each
18.89A Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with
V-profile and with O-ring sealing gasket of EPDM material of required dia as
per direction of Engineer-in-charge.
Sleeve/Slip Coupling/ Socket
18.89A.1 For 15 mm outer dia pipe each
18.89A.2 For 22 mm outer dia pipe each
568.60
568.60
568.60
568.60
568.60
341.15
501.75
414.75
508.40
628.85
923.20
963.30
809.45
1324.55
1378.10
1117.20
73.60
93.65
127.10
180.60
214.05
234.15
501.75
602.05
18.89A.3 For 28 mm outer dia pipe each
Elbow 90°
18.90A.1 For 15 mm outer dia pipe each
18.90A.2 For 22 mm outer dia pipe each
18.90A.3 For 28 mm outer dia pipe each
18.90A.4 For 35 mm outer dia pipe each
18.90A.5 For 42 mm outer dia pipe each
18.90A.6 For 54 mm outer dia pipe each
18.91 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
776.00
896.40
1277.75
86.95
93.65
140.50
160.55
173.95
214.05
408.05
575.30
769.30
1257.65
2033.65
2689.25
200.70
280.95
334.50
394.70
468.30
254.20
18.92 Providing and fixing required Stainless Steel Fitting of press fit design
of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM
material of required dia as per direction of Engineer-in-charge.
Equal Tee
Equal Tee
18.92A.1 For 15 mm outer dia pipe each
18.92A.2 For 22 mm outer dia pipe each
18.92A.3 For 28 mm outer dia pipe each
18.92A.4 For 35 mm outer dia pipe each
18.92A.5 For 42 mm outer dia pipe each
18.92A.6 For 54 mm outer dia pipe each
18.93 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
Reducing Tee
18.93.1 For 22.22 mm x 15.88 mm outer dia pipe each
18.93.2 For 28.58 mm x 15.88 mm outer dia pipe each
18.93.3 For 28.58 mm x 22.22 mm outer dia pipe each
18.93.4 For 34.00 mm x 15.88 mm outer dia pipe each
18.93.5 For 34.00 mm x 22.22 mm outer dia pipe each
18.93.6 For 34.00 mm x 28.58 mm outer dia pipe each
18.93.7 For 42.70 mm x 15.88 mm outer dia pipe each
18.93.8 For 42.70 mm x 22.22 mm outer dia pipe each
18.93.9 For 42.70 mm x 28.58 mm outer dia pipe each
18.93.10 For 42.70 mm x 34.00 mm outer dia pipe each
18.93.11 For 48.60 mm x 15.88 mm outer dia pipe each
ing sealing gasket of EPDM
234.15
334.50
394.70
588.70
929.85
1224.20
668.95
782.70
963.30
1197.45
1672.40
2006.90
247.50
388.00
388.00
588.70
588.70
588.70
923.20
923.20
923.20
923.20
1186.75
18.93.12 For 48.60 mm x 22.22 mm outer dia pipe each
Reducing Tee
18.93A.1 For 22 mm x 15 mm outer dia pipe each
18.93A.2 For 28 mm x 15 mm outer dia pipe each
18.93A.3 For 28 mm x 22 mm outer dia pipe each
18.93A.4 For 35 mm x 15 mm outer dia pipe each
18.93A.5 For 35 mm x 22 mm outer dia pipe each
18.93A.6 For 35 mm x 28 mm outer dia pipe each
18.93A.7 For 42 mm x 22 mm outer dia pipe each
18.93A.8 For 42 mm x 28 mm outer dia pipe each
18.93A.9 For 42 mm x 35 mm outer dia pipe each
18.93A.10 For 54 mm x 22 mm outer dia pipe each
18.93A.11 For 54 mm x 28 mm outer dia pipe each
18.93A.12 For 54 mm x 35 mm outer dia pipe each
18.93A.13 For 54 mm x 42 mm outer dia pipe each
18.94 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
Male Thread Tee
18.94.1 For 15.88 mm outer dia x 15 mm nominal dia threaded each
18.94.2 For 22.22 mm outer dia x 15 mm nominal dia threaded each
18.94.3 For 22.22 mm outer dia x 20 mm nominal dia threaded each
18.94.4 For 28.58 mm outer dia x 15 mm nominal dia threaded each
18.94.5 For 28.58 mm outer dia x 20 mm nominal dia threaded each
18.94.6 For 28.58 mm outer dia x 25 mm nominal dia threaded each
18.94.7 For 34.00 mm outer dia x 15 mm nominal dia threaded each
18.94.8 For 34.00 mm outer dia x 20 mm nominal dia threaded each
18.94.9 For 34.00 mm outer dia x 25 mm nominal dia threaded each
18.94.10 For 34.00 mm outer dia x 32 mm nominal dia threaded each
18.94.11 For 42.70 mm outer dia x 15 mm nominal dia threaded each
18.94.12 For 42.70 mm outer dia x 20 mm nominal dia threaded each
1197.45
1197.45
1197.45
1197.45
769.30
956.65
949.95
1204.15
1210.85
1224.20
1712.55
1692.50
1725.95
2100.55
2060.40
2073.80
2006.90
247.50
287.65
287.65
394.70
394.70
394.70
622.15
622.15
622.15
622.15
949.95
949.95
18.94.13 For 42.70 mm outer dia x 25 mm nominal dia threaded each 949.95
18.94.14 For 42.70 mm outer dia x 32 mm nominal dia threaded each 949.95
18.94.15 For 42.70 mm outer dia x 40 mm nominal dia threaded each 949.95
18.94.16 For 48.60 mm outer dia x 15 mm nominal dia threaded each 1197.45
18.94.17 For 48.60 mm outer dia x 20 mm nominal dia threaded each 1197.45
18.94.18 For 48.60 mm outer dia x 25 mm nominal dia threaded each 1197.45
18.94.19 For 48.60 mm outer dia x 32 mm nominal dia threaded each 1197.45
18.94.20 For 48.60 mm outer dia x 40 mm nominal dia threaded each 1197.45
18.94.21 For 48.60 mm outer dia x 50 mm nominal dia threaded each 1197.45
18.95 Providing and fixing required Stainless Steel Fitting of press fit design
of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM
material of required dia as per direction of Engineer-in-charge.
Female Thread Tee
18.95.1 For 15.88 mm outer dia x15 mm nominal dia threaded each
18.95.2 For 22.22 mm outer dia x 15 mm nominal dia threaded each
18.95.3 For 22.22 mm outer dia x 20 mm nominal dia threaded each
18.95.4 For 28.58 mm outer dia x 15 mm nominal dia threaded each
18.95.5 For 28.58 mm outer dia x 20 mm nominal dia threaded each
18.95.6 For 28.58 mm outer dia x 25 mm nominal dia threaded each
18.95.7 For 34.00 mm outer dia x 15 mm nominal dia threaded each
18.95.8 For 34.00 mm outer dia x 20 mm nominal dia threaded each
18.95.9 For 34.00 mm outer dia x 25 mm nominal dia threaded each
18.95.10 For 34.00 mm outer dia x 32 mm nominal dia threaded each
18.95.11 For 42.70 mm outer dia x 15 mm nominal dia threaded each
18.95.12 For 42.70 mm outer dia x 20 mm nominal dia threaded each
18.95.13 For 42.70 mm outer dia x 25 mm nominal dia threaded each
18.95.14 For 42.70 mm outer dia x 32 mm nominal dia threaded each
18.95.15 For 42.70 mm outer dia x 40 mm nominal dia threaded each
18.95.16 For 48.60 mm outer dia x 15 mm nominal dia threaded each
18.95.17 For 48.60 mm outer dia x 20 mm nominal dia threaded each
18.95.18 For 48.60 mm outer dia x 25 mm nominal dia threaded each
18.95.19 For 48.60 mm outer dia x 32 mm nominal dia threaded each
18.95.20 For 48.60 mm outer dia x 40 mm nominal dia threaded each
18.95.21 For 48.60 mm outer dia x 50 mm nominal dia threaded each
949.95
949.95
949.95
1197.45
1197.45
1197.45
1197.45
1197.45
1197.45
247.50
274.30
274.30
367.95
367.95
367.95
595.40
595.40
595.40
595.40
936.55
936.55
936.55
936.55
936.55
1210.85
1210.85
1210.85
1210.85
1210.85
1210.85
18.95A Providing and fixing required Stainless Steel Fitting of press fit design of grade
316L as per IS 6911:2017 and conforming to EN-10312 standards with V-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
260.90
307.75
321.10
370.60
388.00
474.95
548.55
722.50
796.05
929.85
1130.55
1304.50
588.70
18.96A.2 For 22 mm outer dia x 1/2" mm nominal dia threaded each
776.00
1277.75
1364.70
2093.85
3211.05
260.90
307.75
341.15
434.85
434.85
635.50
755.95
868.30
976.70
1137.25
1525.25
541.85
642.20
675.65
889.75
1297.80
1893.20
2535.40
Valve Connector
18.98.1 For 15.88 mm outer dia x 15 mm nominal dia threaded each
18.98.2 For 22.22 mm outer dia x 15 mm nominal dia threaded each
18.98.3 For 22.22 mm outer dia x 20 mm nominal dia threaded each
18.98.4 For 28.58 mm outer dia x 25 mm nominal dia threaded each
18.98.5 For 34.00 mm outer dia x 32 mm nominal dia threaded each
18.98.6 For 42.70 mm outer dia x 40 mm nominal dia threaded each
18.98.7 For 48.60 mm outer dia x 50 mm nominal dia threaded each
18.99 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction
of Engineer-in-charge.
Female Threaded Elbow 90°
214.05
287.65
287.65
287.65
394.70
642.20
642.20
949.95
949.95
856.30
1150.65
1578.75
2564.85
2793.60
4317.50
260.90
18.100.2 For 22.22 mm outer dia x 15 mm nominal dia threaded each
301.05
301.05
388.00
388.00
642.20
642.20
929.85
929.85
702.40
1056.95
1398.15
1926.65
3525.45
4011.15
64.20
93.65
120.40
234.15
334.50
434.85
428.15
555.25
18.101A.3 For 28 mm outer dia pipe each 689.05
18.101A.4 For 35 mm outer dia pipe each 963.30
18.101A.5 For 42 mm outer dia pipe each 2093.85
18.101A.6 For 54 mm outer dia pipe each 2301.25
18.102 Providing and fixing required Stainless Steel Fitting of press fit design of
grade AISI 304 conforming to JWWA G116 standard with V-profile or M-
profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.
Pipe Bridge
18.102.1 For 15.88 mm outer dia pipe each 294.35
18.102.2 For 22.22 mm outer dia pipe each 388.00
18.102.3 For 28.58 mm outer dia pipe each 555.25
18.102A Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS 6911:2017 and conforming to EN-10312 standard with
V-profile and with O-ring sealing gasket of EPDM material of required dia as
per direction of Engineer-in-charge.
Pipe Bridge
18.102A.1 For 15 mm outer dia pipe each 555.25
18.102A.2 For 22 mm outer dia pipe each 1485.10
18.102A.3 For 28 mm outer dia pipe each 2041.70
18.103 Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS 6911:2017 and conforming to EN-10312 standard with
V-profile and with O-ring sealing gasket of EPDM material of required dia as
per direction of Engineer-in-charge.
Male Union
18.103.1 For 15mm outer dia X 1/2" nominal dia threaded each 1184.05
18.103.2 For 22mm outer dia X 1/2" nominal dia threaded each 1197.45
18.103.3 For 22mm outer dia X 3/4" nominal dia threaded each 1371.40
18.103.4 For 28mm outer dia X 1" nominal dia threaded each 2415.00
18.103.5 For 35mm outer dia X 1-1/4" nominal dia threaded each 2522.00
18.103.6 For 42mm outer dia X 1-1/2" nominal dia threaded each 2849.80
18.103.7 For 54mm outer dia X 2" nominal dia threaded each 4923.60
18.104 Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS 6911:2017 and conforming to EN-10312 standard with
V-profile and with O-ring sealing gasket of EPDM material of required dia as
per direction of Engineer-in-charge.
Female Union
18.104.1 For 22 mm outer dia X 3/4" nominal dia threaded each 1271.05
18.104.2 For 28mm outer dia X 1" nominal dia threaded each 1712.55
18.105 Providing and fixing required Stainless Steel Fitting of press fit design
of grade 316L as per IS 6911:2017 and conforming to EN-10312 standard with V-profile and with O-ring sealing gasket of
EPDM material of required dia as per direction of Engineer-in-charge.
Female Transition Elbow / FTE
18.105.1 For 15mm outer dia X 1/2" nominal dia threaded each 868.30
18.105.2 For 22mm outer dia X 1/2" nominal dia threaded each 1204.15
18.105.3 For 22mm outer dia X 3/4" nominal dia threaded each 1164.00
SUB HEAD : 19.0
DRAINAGE
431
689.05
963.30
2093.85
2301.25
294.35
388.00
555.25
555.25
1485.10
2041.70
1184.05
1197.45
1371.40
2415.00
2522.00
2849.80
4923.60
1271.05
1712.55
ring sealing gasket of
BASIC RATES (SH: 19.0 DRAINAGE)
Code No. Description Unit
1354 C.I. Rectangular cover 455x610 mm with frame (low duty) each
1355 C.I. Rectangular cover 455x610 mm without frame (low duty) each
1356 C.I. 500 mm dia cover with frame (medium duty) each
1357 C.I. 500 mm dia cover without frame (medium duty) each
1364 C.I. grating 100x100 mm each
1366 C.I. grating 150x150 mm each
1367 C.I. grating 180x180 mm each
1617 S.C.I. soil, waste and vent single socketed pipe 1.80 metres long:100 mm dia
each
1618 S.C.I. soil, waste and vent single socketed pipe 1.80 metres long:150 mm dia
each
2602 Common burnt clay F.P.S. (non modular) bricks class designation 7.5
1000 Nos
7131 Square shape 450x450 mm precast R.C.C. manhole cover with frame - L.D. -
2.5 each
7132 Circular shape 450 mm dia precast R.C.C. manhole cover with frame - L.D. -
2.5 each
7133 Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame -
M.D. - 10 each
7134 Circular shape 500 mm dia precast R.C.C. manhole cover with frame- M.D.-10
each
7135 Circular shape 560 mm dia precast R.C.C. manhole cover with frame - H.D. -
20 each
7136 Circular shape 560 mm dia precast R.C.C. manhole cover with frame - E.H.D.
- 35 each
714.00
714.00
645.00
645.00
784.00
714.00
650.00
650.00
450.00
5000.00
900.00
4750.00
4850.00
44.00
50.00
480.00
477.00
1400.00
910.00
4400.00
2300.00
40.00
55.00
65.00
1135.00
1750.00
280.00
475.00
405.00
210.00
220.00
365.00
450.00
775.00
950.00
1150.00
1500.00
1825.00
2550.00
2950.00
3250.00
3575.00
35.00
37.00
55.00
56.00
110.00
120.00
145.00
160.00
225.00
240.00
295.00
315.00
375.00
1500.00
2000.00
3175.00
3915.00
5200.00
9450.00
1750.00
2350.00
4500.00
5570.00
6510.00
13650.00
70.00
125.00
200.00
350.00
525.00
55.00
115.00
155.00
230.00
437.15
145.72
218.58
437.15
728.59
1249.01
1561.26
178.19
163.93
145.72
358.32
597.20
1380.48
1706.30
3981.36
5972.04
8958.06
11944.08
11944.08
11944.08
11944.08
4590.00
9100.00
5100.00
570.00
185.00
240.00
675.00
575.00
575.00
670.00
575.00
880.00
1170.00
110.00
620.00
235.00
620.00
2.12
2.12
2.12
19.0 DRAINAGE
Code No. Description Unit
NOTE : - The rates given for all the items under sub-head ‘Drainage’ are
applicable to work executed in soils above sub- soil water level. Extra
allowance has to be made for work under sub- soil water level.
375.75
591.40
830.40
1293.90
1774.50
895.50
1095.15
1276.70
1476.35
425.60
689.75
810.80
943.90
1089.10
2453.55
2407.65
19.4.2 150 x 100 mm size P type
19.4.2.1 With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 each
2428.45
2534.00
2488.10
g of useful materials near the
73.35
81.10
86.30
91.45
96.65
111.30
121.70
126.85
ointed with stiff mixture of
omplete :
447.25
493.10
811.15
902.05
1481.55
1745.20
2098.10
2629.35
3144.45
4260.35
5007.00
5625.95
6334.40
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1
cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone
aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement
: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with
a floating coat of neat cement complete as per standard design :
11687.10
11567.00
24405.90
24077.30
30197.95
29915.30
8127.45
7777.70
9744.25
9327.40
19.9 Constructing brick masonry circular type manhole 0.91 m internal
dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement
: 4 coarse sand), inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat
of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size), and making
necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) finished
with a floating coat of neat cement, all complete as per standard
design :
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20
grade designation) 560 mm internal diameter con- forming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg., fixed in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) including centering, shuttering all complete. (Excavation, foot rests and
12mm thick cement plaster at the external surface shall be paid for
separately) :
19.13.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade
designation) 560 mm internal diameter conform- ing to I.S. 12592, total weight
of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4
(1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
including centering, shuttering all complete. (Excavation, foot rests and 12 mm
thick cement plaster at the external surface shall be paid for separately) :
19.18.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to
be not less than 58 kg each
19.18.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to
be not less than 108 kg each
19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of
required shape and approved quality
19.19.1 L D- 2.5
19.19.1.1 Rectangular shape 600x450 mm internal dimensions
each
19.21 Making connection of drain or sewer line with existing manhole including
breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both
sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of
neat cement and making necessary channels for the drain etc. complete :
19.23.1 For 100 mm dia sand cast iron drop connection metre
19.23.2 For 150 mm dia sand cast iron drop connection metre
19.24 Dismantling of manhole including R.C.C. top slab, C.I. cover with frame,
including stacking of useful materials near the site and disposal of unserviceable
materials within 50 m lead as per direction of Engineer-in-charge:
19.25.4 Circular manhole 122 cm diameter and beyond 1.68 m depth (up to
2.29 m depth) metre
19.26 Raising manhole cover and frame slab to required level including dismantling
existing slab and making good the damage as required (Raising depth of manhole to be
paid separately) :
19.26.4 Circular manhole 140 cm dia with circular cover 600 mm dia of grade
EHD - 35 each
19.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in
cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C.
horizontal grating with frame complete as per standard design :
19.27.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 each
19.28 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in
cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating
complete as per standard design :
19.28.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 each
19.29 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in
cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C.
horizontal grating with frame and vertical grating complete as per standard design :
19.29.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 each
19.30 Constructing brick masonry chamber for underground C.I. inspection chamber
and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with
frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be
not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with
1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size),
foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm
nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement
: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed
concrete etc. complete as per standard design:
11666.90
6986.80
6693.95
22951.95
22463.90
9068.35
8686.10
49193.00
47828.25
21103.40
20114.90
461.35
420.00
487.10
564.60
523.25
1341.35
3219.00
6972.75
1255.25
1047.80
1047.80
1257.40
1056.65
1494.20
1882.20
671.75
683.70
785.90
1134.65
10137.65
13789.75
2792.70
3608.00
2096.10
3691.10
6982.55
5338.95
1686.65
2009.35
1628.95
1837.85
2723.65
4290.35
3989.40
326.45
5589.45
6258.20
10596.95
two inlets :
19.30.3 Inside dimensions 600x 850 mm and 45 cm deep for pipe
line with three or more inlets :
19.30.3.1 With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 each 8613.20
19.31 Extra for depth beyond 45 cm of brick masonry chamber :
19.31.1 For 455x610 mm size
19.31.1.1 With common burnt clay F.P.S. (non modular)
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey
comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per
standard design.
19.32.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 each
each
19.34 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of
cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
6158.05
7177.15
28029.15
2940.20
378.45
513.15
2385.50
3051.55
4821.65
5980.10
8118.55
14292.75
19.36 Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C.
pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand)
including testing of joints etc. complete
2720.00
3519.85
6594.40
8194.40
9871.25
19912.10
BASIC RATES (SH: 20.0 PILE WORK)
Code No. Description Unit
0015 Hire and running charges of Tripod and Mechanical Winch machine complete
with power unit and accessories day
per test
7247 Vertical load testing (initial) of piles in accordance with IS : 2911 (Part-IV)
including installation of loading platform and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete
as per specification & above 50 tonne and up to 100 tonne
per test
7248 Vertical load testing (initial) of piles in accordance with IS : 2911 (Part-IV)
including installation of loading platform and preparation of pile head or
construction of test cap and dismantling of test cap after test etc. complete as
per specification & group of two
or more up to 50 tonne
per test
7249 Cyclic vertical load testing of piles in accordance with IS : 2911 (Part-IV)
including preparation of pile head etc. for Single pile up to 50 tonne capacity
per test
7250 Cyclic vertical load testing of piles in accordance with IS : 2911 (Part-IV)
including preparation of pile head etc. for Single pile above 50 tonne capacity
pile and up to 100 tonne capacity pile
per test
7251 Cyclic vertical load testing of piles in accordance with IS : 2911 (Part-IV)
including preparation of pile head etc. for Group of two piles up to 50 tonne
capacity each
per test
7252 Lateral load testing of single pile in accordance with IS : 2911 part -IV for
determining safe allowable lateral load on pile up to 50 tonne capacity
per test
7253 Lateral load testing of single pile in accordance with IS : 2911 part -IV for
determining safe allowable lateral load on pile above 50 tonne capacity
per test
9977 Carriage L.S.
9999 Sundries L.S.
Rate
3000.00
3750.00
6000.00
35000.00
3500.00
3000.00
30000.00
7000.00
7500.00
3000.00
645.00
784.00
853.00
645.00
48.00
43.00
2800.00
38500.00
43000.00
49500.00
13800.00
22800.00
28500.00
13800.00
23100.00
2.12
2.12
20.0 PILE WORK
Code No. Description Unit
20.1 Providing, driving with hydraulic piling rigs with power units and installing
driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified
diameter and length below the pile cap, to carry safe working load not less
than specified, excluding the cost of steel reinforcement but including the cost
of shoe and the length of pile to be embedded in the pile cap etc. all complete.
(Length of pile for payment shall be measured from top of shoe to the bottom
of pile cap) :
2333.50
2889.45
3475.40
3813.10
6508.40
10723.35
14025.05
19835.70
1916.40
2274.25
3060.10
4695.05
Note: Truck Mounted rotary/TMR/Tube well boring machine shall
not be used.
20.2A.1 600 mm dia piles metre
20.2A.2 750 mm dia piles metre
20.2A.3 1000 mm dia piles metre
20.2A.4 1200 mm dia piles metre
20.2A.5 1500 mm dia piles metre
20.3 Boring with hydraulic piling rigs with power units, providing and installing cast in
situ single under reamed piles of specified diameter and length below pile cap in M-25
cement concrete, to carry a safe working load not less than specified, excluding the cost of
steel reinforcement but including the cost of boring with bentonite solution and the length
of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall
be measured upto to the bottom of pile cap) :
2560.90
3178.00
3545.20
3956.75
2182.60
2433.80
2585.20
2800.80
3143.80
4007.00
4151.55
4739.10
9104.75
12537.45
20.6 Vertical load testing of piles in accordance with IS 2911 (Part IV)
including installation of loading platform by Kentledge/Anchor piles method and
preparation of pile head or construction of test cap and dismantling of test cap after test
etc. complete as per specification & the direction of Engineer in-charge.
Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic
method of testing.
Note: 2. Testing agency shall submit the design of loading platform for the
approval of Engineer-in-charge.
20.6.1.2 Routine test (Test Load 1.5 times the Safe capacity)
per test 18463.55
20.6.2 Single pile above 50 tonne and upto 100 tonne Safe
capacity
20.6.2.1 Initial test (Test Load 2.5 times the Safe
capacity) per test 57531.30
20.7 Cyclic vertical load testing of pile in accordance with IS Code of practice
IS:2911 (part IV) by Kentledge method including preparation of pile head etc for.
18463.55
57531.30
30505.00
66227.90
38131.20
18463.55
30505.00
38131.20
18463.55
30906.35
g soil, mud, dust &
al for conducting the
echnical sanctioning
BASIC RATES (SH: 21.0 ALUMINIUM WORK)
Code No. Description Unit
2407 Float glass panes of nominal thickness 5 mm (weight not less than 12.50
kg/sqm) sqm
2408 Float glass panes of nominal thickness 8 mm (weight not less than 20.00
kg/sqm) sqm
2604 Weather/structural non sag elastomeric PU sealant (600ml Sausage) for joints
in RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum/ Alluminium work complying to
ASTM C920, DIN 18540-F & ISO 11600 incl all taxes
each
2704 Aluminium Strip 40 mm wide and 2 mm thick kg
7001 Brass 100mm mortice latch and lock with 6 levers without pair of handles
each
7347 Cadmium plated full threaded steel screws (30x4 mm dia) 100 Nos
7348 Aluminium washer 2 mm thick 15 mm dia 100 Nos
7388 Dash hold fastener 12.5 mm dia, 50 mm long with 6 mm dia bolt each
7389 Anodising 15 microns on aluminium sections kg
7390 EPDM Gasket for uPVC window/door metre
7391 Anodising 25 microns on aluminium sections kg
7392 Powder coating 50 microns on aluminium sections kg
7393 Polyester powder coating 50 microns on aluminium sections kg
7394 Double action hydraulic floor spring with stainless steel cover plate each
7395 6 mm dia G.I. adjustable hangers including clips (up to 1.2 m length) each
7396 Double action hydraulic floor spring with brass cover plate each
7477 Prelaminated particle board with one side decorative and other side balancing
lamination, flat pressed 3 layer & graded (medium density) Grade i, Type II
conforming to IS : 12823 (exterior grade) 12 mm thick
sqm
7480 Prelaminated particle board with both sides decorative lamination, flat pressed 3
layer & graded (medium density) Grade I, Type II conforming to IS : 12823
(exterior grade) 12 mm thick
sqm
8646 Weather Silicon sealant cartridge
8647 Stainless steel screws 30 mm x4 mm 100 Nos
8648 Hermetically sealed double glazed unit made with 6 mm thick clear float glass
both side having 12 mm air gap sqm
8649 Stainless steel (SS 304 grade) adjustable friction window stay 205 x 19 mm
each
8650 Stainless steel (SS 304 grade) adjustable friction window stay 255 x 19 mm
each
8651 Stainless steel (SS 304 grade) adjustable friction window stay 355 x 19 mm
each
8652 Stainless steel (SS 304 grade) adjustable friction window stay 510 x 19 mm
each
8653 Stainless steel (SS 304 grade) adjustable friction window stay 710 x 19 mm
each
714.00
784.00
714.00
645.00
784.00
714.00
784.00
714.00
714.00
160.00
393.00
5000.00
309.00
515.00
628.00
543.00
240.00
195.00
12.50
22.00
190.00
10.00
27.00
10.00
10.00
38.00
15.00
48.00
61.00
67.00
1500.00
20.00
1620.00
500.00
490.00
112.00
35.84
2200.00
197.80
225.00
195.00
535.00
925.00
2.18
48.00
52.64
51.52
59.36
60.00
62.00
41.80
440.00
230.00
47.04
279.00
17.00
1750.00
2.12
2.12
2.12
21.0 ALUMINIUM WORK
Code No. Description Unit
21.1 Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733 and
IS: 1285, fixing with dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for glazing / paneling, C.P.
brass / stainless steel screws, all complete as per architectural drawings and
the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to
be paid for separately) :
kg
21.1.1.2 Powder coated aluminium (minimum thickness of
powder coating 50 micron) kg
kg
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket
required (Fittings shall be paid for separately)
kg
21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three
layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling
fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless
steel screws etc. complete as per architectural drawings and directions of engineer- in-
charge.
433.95
466.30
474.70
xing hinges/ pivots and
M rubber / neoprene gasket
531.80
564.80
573.40
965.10
951.05
21.3 Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the
directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5 mm thickness (weight not less than
12.50 kg/sqm) sqm
21.3.3 With float glass panes of 8 mm thickness (weight not less than 20
kg/sqm) sqm
21.4 Providing and fixing double action hydraulic floor spring of approved brand and
manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with
double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting
floors, embedding in floors as required and making good the same matching to the existing
floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with
slide plate etc. complete as per the direction of Engineer-in-charge.
kg
21.6 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm
length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60
mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long,
complete as per direction of Engineer-in-charge.
each
21.7 Providing and fixing machine moulded aluminium covering of approved pattern
& design, made out of machine cut aluminium sheet and machine holed for receiving dash
fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one
row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia
and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a
staggered pitch of 200mm centre to centre including drilling holes in the receiving surface
and providing expandable plastic sleeves in holes etc. complete as per direction of
Engineer-in-charge.
itectural drawings and the
:
1019.80
1325.55
1496.15
2448.85
2609.40
674.60
70.95
21.7.1 Anodised aluminium sheet 2.5mm thick (anodised trans-
parent or dyed to required shade according to IS: 1868, Minimum anodic
coating of grade AC 15)
kg
21.7.2 Powder coated aluminium sheet 2.5mm thick (minimum thickness
of powder coating 50 micron) kg
21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/
Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge complete.
sqm
21.11 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows
stays of approved quality with necessary stainless steel screws etc. to the side hung
windows as per direction of Engineer- in-charge complete.
21.13 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without
pair of handles (best make of approved quality) for aluminium doors including necessary
cutting and making good etc.
complete.
each
603.30
635.60
85.25
13.40
13.40
4013.35
292.80
329.20
289.05
743.95
1265.75
513.20
563.50
576.60
449.55
21.14 Providing and fixing anodised aluminium (anodised transparent or
dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15)
sub frame work for windows and ventilators with extruded built up standard tubular
sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of
required dia and size (Dash fastener to be paid for separately).
kg 357.90
21.15 Providing and fixing aluminium casement windows fastener of required length
for aluminium windows with necessary screws etc. complete.
21.15.1 Anodized (AC 15) aluminium each 73.55
21.15.2 Powder coated minimum thickness 50 micron aluminium each 79.75
21.15.3 Polyester powder coated minimum thickness 50 micron aluminium
each 78.25
21.16 Providing and fixing aluminium round shape handle of outer dia 100 mm with
SS screws etc. complete as per direction of Engineer-in- charge
21.17 Providing and fixing anodised aluminium grill (anodised transparent or dyed to
required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of
approved design/pattern, with approved standard section and fixed to the existing window
frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting
the grill to proper opening size for fixing and operation of handles and fixing approved
anodised aluminium standard section around the opening, all complete as per requirement
and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
kg 560.85
21.18 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without
pair of handles (best make of approved quality) for aluminium doors including necessary
cutting and making good etc. complete.
sqm 4540.70
21.19 Filling the gap in between aluminium/ stone/ wood frame and adjacent
RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non
sag elastomeric PU sealant over backer rod of approved quality as per architectural
drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN
18540- F & ISO 11600
465
357.90
73.55
79.75
78.25
88.75
89.60
92.25
560.85
4540.70
130.20
177.00
320.25
BASIC RATES (SH : 22.0 WATER PROOFING)
Code No. Description Unit
0002 Hire charges of Concrete Mixer 0.25 to 0.40 cum with Hopper day
800.00
350.00
714.00
645.00
645.00
784.00
714.00
714.00
714.00
784.00
714.00
749.00
784.00
650.00
1400.00
1350.00
1350.00
34790.00
47.00
70.00
80.00
70.00
195.00
230.00
190.00
280.00
325.00
1300.00
5000.00
440.00
1500.00
250.00
800.00
35.00
84.00
187.35
163.93
163.93
145.72
163.93
145.72
178.19
45.00
75.00
200.00
160.00
160.00
80.00
120.00
130.00
190.00
210.00
85.00
45.00
160.00
32.00
230.00
225.00
42.00
2.12
2.12
22.0 WATER PROOFING
Code No. Description Unit
22.1 Providing and laying integral cement based treatment for water proofing on
horizontal surface at all depth below ground level for under ground structures
as directed by Engineer-in-Charge and consisting of :
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand)
mixed with water proofing compound in recommended proportions.
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water
proofing compound conforming to IS 2645 in recommended proportions
including rounding off junction of vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg.
per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC
sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7
kg/sqm).
sqm
Rate
1362.95
1780.30
774.25
22.4 Providing and Placing in position suitable PVC water stops conforming
to IS:12200 for construction/ expansion joints between two RCC members and fixed to the
reinforcement with binding wire before pouring concrete etc. complete :
22.4.1 Serrated with central bulb (225 mm wide, 8-11 mm thick) metre
22.4.2 Dumb bell with central bulb (180 mm wide, 8 mm thick) metre
22.4.3 Kickers (320 mm wide, 5 mm thick) metre
22.5 Providing and laying water proofing treatment in sunken portion of WCs,
bathroom etc., by applying cement slurry mixed with water proofing cement compound
consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air
cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water
proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air
cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints,
corners, junctions of pipes and masonry with polymer mixed slurry.
sqm
22.6 Providing and laying water proofing treatment on roofs of slabs by applying
cement slurry mixed with water proofing cement compound consisting of applying:
(b) laying second layer of Fibre glass cloth when the first layer is still green.
Overlaps of joints of fibre cloth should not be less than 10 cm.
(d) fourth and final layer of brick tiling with cement mortar (which will be paid
for separately.
For the purpose of measurement the entire treated surface will be measured.
sqm
22.7 Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining walls
upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand)
admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer- in-charge over 20 mm thick layer of cement mortar of
mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer- in-charge to required slope
and treating similarly the adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including laying
glass fibre cloth of approved quality in top layer of plaster and finally finishing
the surface with trowel with neat cement slurry and making pattern of 300x300
mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum
period of two weeks for curing and for final test.“All above operations to be
done in order and as directed and specified by the Engineer-in-Charge :
22.8 Providing and laying four courses water proofing treatment with bitumen felt
over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming
to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course
of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final
course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter
per square metre, including preparation of surface but excluding grading complete with :
22.9 Providing and laying six courses water proofing treatment with
bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or
90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of
area respectively, second and fourth courses of roofing felt type 3 grade I conforming to
IS : 1322 (Hessian based self finished bitumen felt) , sixth and final course of stone grit 6
mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including
preparation of surface but excluding grading, complete.
sqm
22.10 Providing and laying six courses water proofing treatment with bitumen felt
over roofs consisting of first, third and fifth courses of blown or / and residual bitumen
applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and
fourth courses of roofing felt type 2 grade I (fibre base self finished bitumen felt) six and
final courses of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic
decimeter per sqm including preparation of surface, excluding grading, compete.
sqm
22.11 Providing and laying six courses water proofing treatment with bitumen felt
over roofs consisting of first, third and fifth courses of blown or / and residual bitumen
applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and
fourth courses of roofing felt type 2 grade II (glass fibre base self finished bitumen felt) and
sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6
cubic decimeter per sqm including preparation of surface but excluding grading, complete.
sqm
22.12 Supplying and applying bituminous solution primer on roof and / or wall surface
at 0.24 litre per sqm. sqm
22.13 Deduct for omitting in water proofing treatment final course of spreading
stone grit 6 mm down size or pea sized gravel :
22.13.1 at 6 cudm per sqm sqm
22.13.2 at 8 cudm per sqm sqm
22.14 Grading roof for water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) cum
516.60
585.55
1522.95
432.10
675.00
773.50
773.95
50.25
15.80
19.85
7510.75
14275.75
13378.15
compared with control concrete as per DIN 1048 and resistant to 16
bar hydrostatic pressure. The crystalline admixture shall be capable of self-
healing of cracks up to a width of 0.50mm. The work shall be carried out all
complete as per specification and the direction of the Engineer-in-charge. The
product performance shall carry guarantee for 10 years against any leakage.
kg 332.40
22.22A Providing and applying fibre reinforced elastomeric liquid water proofing
membrane with resilient acrylic polymers having Sun Reflectivity Index
(SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm.
One coat of self-priming of elastomeric waterproofing liquid (dilution with
water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing
liquid (dry film thickness of complete application/system not less than 500
microns). The operation shall be carried out after scrapping and properly
cleaning the surface to remove loose particles with wire brushes, complete in
all respect as per the direction of Engineer-in-Charge.
sqm 474.15
22.23 Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the
basement, water tanks, roof slabs, podiums, reservior, sewage & water
treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in
the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical
surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for
horizontal surfaces and applying the same from negative (internal) side with
the help of synthetic fiber brush. The material shall meet the requirements as
specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by
more than 90% compared with control concrete as per DIN 1048 and
resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The
work shall be carried out all complete as per specification and the direction of
the engineer-in-charge. The product performance shall carry guarantee for 10
years against any leakage.
22.23.1 For vertical surface two coats @ 0.70 kg per sqm sqm 406.25
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 311.50
22.23A Providing & Applying polymer modified, flexible cementatious negative side
waterproofing coating with elastic waterproofing polymers on interior wall
plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of
cementatious waterproofing polymer(dilution with water in the ratio of 1:1)
and two coats of cementatious waterproofing polymer (dilution with water
in the ratio of 3:1 ) after scrapping and properly cleaning the surface to
remove pre-existing paint film & loose particles till plaster is visible, complete
in all respect as per the direction of Engineer-in-Charge.
sqm 522.20
22.24 Providing and applying integral crystalline (dry shake) of hydrophilic in nature
for waterproofing treatment to the RCC structures like
basement raft, foundation slab, sewage & water treatment plant slab,
warehouses floor, parking structures and water tank base slab etc. sprinkled
@0.60kg per sqm or higher as recommended by the manufacturer's
specification over the lean concrete of above cited structures. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing
permeability of concrete by more than 85%, compared control concrete as
per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.
The crystalline dry- shake shall be capable of self-healing of cracks up to a
width of 0.50mm. The work shall be carried out all complete as per
specification and the direction of the Engineer-in-charge. The product
performance shall carry guarantee for 10 years against any leakage.
sqm 265.75
22.24A Providing & Applying high quality acrylic modified resin based texture of
Dholpur/Red sand stone Pattern with anti algae and UV resistance properties
to be applied as intermediate finish in desired pattern @
43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and
properly cleaning the surface to remove loose particles from the plaster
surface, followed by top coating with Premium Acrylic Smooth exterior paint
with Silicone additives of required shade by two or more coats @ 1.43
litres/10 sqm, complete as the direction of Engineer -in-Charge.
sqm 482.05
22.25 Providing and applying crystalline mortar by mixing in the ratio of 4.5
: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty
construction joints, cracks, tie rod holes and spalled & honeycombed
surface of RCC underground structures like basement, water tanks, bridge
deck etc. to ensure water tightness. The crystallie mortar shall conform to the
EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive
bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete
as per specification and the direction of the engineer-in-charge. The product
performance shall carry guarantee for 10 years against any leakage.
metre 469.65
22.25.2 For patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry
474.15
406.25
311.50
522.20
265.75
482.05
469.65
19.95
3940.00
7000.00
1600.00
714.00
645.00
645.00
645.00
784.00
714.00
784.00
645.00
80.87
358.32
597.20
971.45
358.32
597.20
971.45
1126.00
1400.00
490.00
700.00
150.00
200.00
200.00
220.00
500.00
810.00
810.00
815.00
815.00
815.00
780.00
405.00
425.00
135.00
160.00
875.00
1500.00
125.00
205.00
265.00
910.00
2.12
2.12
23.0 RAIN WATER HARVESTING & TUBEWELLS
Code No. Description Unit
23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable
method prescribed in IS: 2800 (part I), including collecting samples from
different strata, preparing and submitting strata chart/ bore log, including hire
& running charges of all equipments, tools, plants & machineries required for
the job, all complete as per direction of Engineer-in-charge, upto 90 metre
depth below ground level.
592.05
647.55
828.85
1416.30
1497.25
1777.90
690.70
767.45
1036.10
1561.70
1632.15
2082.35
553.20
668.50
971.30
23.4 Supplying, assembling, lowering and fixing in vertical position in bore
well unplasticized PVC medium well screen (RMS) pipes with ribs,
conforming to IS: 12818, including hire & labour charges, fittings &
accessories etc. all complete, for all depths, as per direction of
Engineer-in-charge.
23.4.1 100 mm nominal size dia metre 579.95
23.4.2 150 mm nominal size dia metre 681.90
23.4.3 200 mm nominal size dia metre 1099.25
23.5 Supplying, filling, spreading & leveling stone boulders of size range
5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all
complete as per direction of Engineer-in-charge. cum 1302.30
23.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5
mm to 2 mm in recharge pit, in required thickness over gravel layer,
for all leads & lifts, all complete as per direction of Engineer -in- charge.
cum 1309.00
23.9 Providing and fixing factory made precast RCC perforated drain covers,
having concrete of strength not less than M-25, of size 1000 x 450x50
mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross
sectional T.M.T. hoop bars, including providing 50 mm dia perforations
@ 100 to 125 mm c/c, including providing edge binding with M.S.
flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer- in-
charge. each 1213.25
23.13 Providing and fixing suitable size threaded mild steel cap or spot
welded plate to the top of bore well housing/ casing pipe, removable
as per requirement, all complete for borewell of:
23.13.1 100 mm dia each 189.65
23.13.2 150 mm dia each 210.75
23.13.3 200 mm dia each 280.95
23.14 Providing and fixing M.S. clamp of required dia to the top of casing/
housing pipe of tubewell as per IS: 2800 (part I), including necessary
bolts & nuts of required size complete.
23.14.1 100 mm clamp each 1522.50
23.14.2 150 mm clamp each 1609.25
23.14.3 200 mm clamp each 1827.00
23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the
bottom of pipe assembly of tubewell as per IS:2800 (part I).
23.15.1 100 mm dia each 228.25
23.15.2 150 mm dia each 281.75
23.15.3 200 mm dia each 308.55
SUB HEAD : 24.0
CONSERVATION OF
HERITAGE BUILDINGS
579.95
681.90
1099.25
1302.30
1309.00
1309.00
1479.25
1213.25
1172.30
1675.80
2082.10
1258.00
1790.00
2194.85
916.80
189.65
210.75
280.95
1522.50
1609.25
1827.00
228.25
281.75
308.55
BASIC RATES (SH: 24.0 CONSERVATION OF HERITAGE BUILDINGS)
Code No. Description Unit
714.00
714.00
645.00
645.00
784.00
714.00
714.00
714.00
749.00
784.00
300.00
5200.00
700.00
145.72
60.00
1300.00
46.00
40.00
145.00
765.00
48.00
270.00
1100.00
835.00
50.00
145.00
500.00
2.12
24.0 CONSERVATION OF HERITAGE BUILDINGS
Code No. Description Unit Rate
24.1 Raking out joints of stone masonry surface to the required width and depth,
with due care and precaution, by mechanical / manual means, including
preparing and cleaning the surface for re-pointing/ refilling of joints, including
disposal of rubbish to the dumping ground within 50 metre lead.
sqm 59.75
24.2 Providing and fixing double scaffolding system (cup lock type) on the exterior
side of building/structure, upto 25 metre height, above ground level, including
additional rows of scaffolding in stepped manner as per requirement of site,
made with 40mm dia M.S. tube, placed
1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock
system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system
in the scaffolding for working platform etc. and maintaining it in a serviceable
condition for execution of work of cleaning and/ or pointing and/ or applying
chemical and removing it thereafter. The scaffolding system shall be stiffened
with bracings, runners, connecting with the building etc, wherever required, if
feasible, for inspection of work at required locations with essential safety
features for the workmen etc., complete as per directions and approval of
Engineer-in-charge.
Note:- (1) The elevational area of the scaffolding shall be measured for
payment purpose. (2) The payment will be made once only for execution of all
items for such works.
sqm 285.00
24.3 Cleaning the sand stone surface and removing dirt, dust, bird dropping,
grease, oil, algae, fungus, monkey beats, vegetable growth etc., including
providing, applying and washing the surface with liquid Ammonia Chemical of
5% solution and other chemical cleaning agent as approved by Archaeological
Survey of India/ Engineer-in-charge, of approved brand and manufacturer,
with the help of required scrubbers and also cleaning with machine
operated water jet mixed with desired quantity of fine silica where ever
required, without causing any scratching/ damage to the stone surface and
finally washing the surface with clean water with the help of pressure jet
machine, complete in all respect, including taking all precautions to safeguard
ventilators, windows, doors etc. by suitable covering so as to avoid any
damage to the building/structure, all as per direction of Engineer- in-charge
(The rate is inclusive of all materials & labours involved except scaffolding).
sqm 174.85
24.4 Providing and applying antifungal wash treatment using 3% solution of sodium
pentachlorophenate, of reputed brand and manufacturer, on cleaned sand
stone surface at desired locations as per direction of Engineer-in-charge (The
rate is inclusive of all materials & labours involved except scaffolding).
sqm 64.10
24.5 Ruled / Flush pointing on Red sand stone masonry surface with lime, surkhi
and marble dust mortar in the ratio of 1:1.5:1/2 {One lime: 1.5 surkhi (50% red
and 50% light yellow surkhi ) : 1/2 marble dust}. (The rate is inclusive of all
materials & labours involved except scaffolding).
sqm 310.05
24.6 Ruled/ Flush pointing on White sand stone masonry surface with lime, surkhi
and marble dust mortar in the ratio of 1:1.5:1/2 {One lime : 1.5 surkhi (15%
dark red and 85% light yellow surkhi) : 1/2 marble dust}. (The rate is inclusive
of all materials & labours involved except scaffolding).
sqm 310.05
24.7 Applying two or more coat of Ethyl Silicate chemical as approved by
Archaeological Survey of India/ Engineer-in-charge, of approved brand and
manufacturer, with brush or spray on the existing stone masonry surface till
there is no further absorption of chemical by stone surface, including
protecting the applied surface from direct sunlight by suitable means during
application, all complete as per direction of the Engineer-in-Charge (The
rate is inclusive of all materials & labours involved except scaffolding).
sqm 281.40
24.8 Applying breathable, non-reactive, antifungal, and water repellant
Silane/Siloxane chemical as approved by Archaeological Survey of India/
Engineer-in-charge, of approved brand and manufacture, diluted with solvent
mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12
Part of Turpentine oil), on the existing sand stone masonry surface with two
or more coats to give uniform application of chemical on the surface, all
complete as per direction of Engineer-In-charge (The rate is inclusive of all
materials & labours involved except scaffolding).
sqm 91.35
SUB HEAD : 25.0
STRUCTURAL GLAZING ALUMINIUM
COMPOSITE PANEL
Rate
59.75
285.00
174.85
64.10
310.05
310.05
281.40
91.35
BASIC RATES (SH: 25.0 STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
Code No. Description Unit
2415 21mm thick clear toughened Laminated glass for fins with holes sqm
6120.00
31.00
21.00
332.00
102.00
104.00
484.00
156.00
11.00
37.00
4.00
22.00
61.00
1030.00
670.00
132.00
1390.00
36.00
87.00
36.00
260.00
122.00
255.00
7.00
125.00
245.00
6.00
1100.00
480.00
55.00
190.00
61.00
160.00
70.00
2.18
47.04
3318.00
1659.00
1300.00
651.00
5931.00
2.12
5
d) unitized system of structural
and all levels, including:
oads conforming to IS 875 part
ure), including functional
cleats, sleeves and splice
sealants, flashings, fire stop
ualisation & drainage and
metically-sealed 6-12- 6 mm
, comprising of an outer heat
on surface # 2 of approved
wide, dessicants, including
performances, as per the
e Engineer-in-Charge. The
sqm 3377.50
25.4 Extra for openable side / top hung vision glass panels (IGUs) including
providing and supplying at site all accessories and hardwares for the openable panels as
specified and of the approved make such as heavy duty stainless steel friction hinges, min
4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including
necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per
the Architectural drawings, as per the approved shop drawings, as specified and as
directed by the Engineer- in- Charge.
sqm 3309.05
25.5 Providing, fabricating and supplying shadow box of required size and shape, for
fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear
portions of the building by providing semi
-rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS:
8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on
surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of
nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly
oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm
thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets,
nuts, bolts, washers etc complete.
sqm 1954.30
25.6 Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat
strengthened monolithic float glass of approved colour and shade with reflective soft
coating on surface # 2 of approved colour and shade so as to match the colour and shade
of the IGUs in the vision panels etc. ,all complete for the required performances as
specified, as per the Architectural drawings, as per the approved shop drawings, as
specified, and as directed by the Engineer- in- Charge.
For payment, only the actual area of glass on face # 1 of the glass panels (but
excluding the area of grooves and weather silicone sealant) provided and fixed
in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass
Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured
tinted float glass 6mm thick substrate with reflective soft coating on face # 2,
having properties as visible Light transmittance (VLT) of 25 to 35 %, Light
reflection internal 10 to 15%, light reflection external 10 to 20 %, shading
coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties
of performance glass shall be decided by technical sanctioning authority as per
the site requirement.
sqm 2213.50
25.8 Design supply & installation of suspended Spider Glazing system
designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-
316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with
SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass
panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and
at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved
make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and
approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc.
The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non
staining weather sealant, so as to make the entire system fully water proof & dust proof.
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P,
scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer,
Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual
elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS
channel shall be measured. sqm 8230.05
SUB HEAD : 26.0
NEW TECHNOLOGIES AND
MATERIALS
3377.50
3309.05
1954.30
2213.50
0002 Hire charges of Concrete Mixer 0.25 to 0.40 cum with Hopper day
0009 Pumping charges of concrete including Hire charges of pump, piping work &
accessories etc. cum
800.00
210.00
700.00
350.00
6000.00
7000.00
3000.00
500.00
11500.00
1350.00
3500.00
3000.00
4500.00
8000.00
15000.00
300.00
8500.00
4000.00
400.00
500.00
5.00
200.00
714.00
714.00
784.00
714.00
784.00
714.00
645.00
645.00
645.00
784.00
0117 Assistant Fitter or 2nd class Fitter day
0119 Glazier day
0122 Mason (for plaster of paris work) 1st class day
0123 Mason (brick layer) 1st class day
0124 Mason (brick layer) 2nd class day
0125 Mason (for plain stone work) 2nd class day
0126 Mason (for ornamental stone work) 1st class day
0127 Driver for (Road roller, concrete mixer, Trucks etc.) day
0128 Mate day
0129 Sewer man day
0130 Mistry day
0131 Painter day
0132 Rock Excavator day
0133 Rock Breaker day
0134 Rock Hole Driller day
0135 Stone Chiseller day
0138 Sprayer (for bitumen, tar etc.) day
0139 Skilled Beldar (for floor rubbing etc.) day
0141 White Washer day
0154 Nozzel man/ gun man day
0155* Mason (average) day
0156* Carpenter (average) day
0157 Operator (Pile/ Special machine) day
0159 Skilled torch operator for laying tack day
0160 Technician day
0161 Helper (Technician) day
0164 Security guard without gun (8 hours shift duty per day) day
0165 Security guard with gun (8 hours shift duty per day) day
0166 Installation charges for fixing of façade at all heights with extruded hollow
clay/terracotta ventillated rain screen tiles sqm
14862:2000 sqm
0245 Factory made light weight non asbestos fibre reinforced aerated cement
sandwitched wall/roof panel (75mm thick). The outer face on both sides of the
panels will be non asbestos fibre cement board (minimum 5mm thick)
confirming to IS 14862:2000
sqm
0246 2mm thick sim pad each
0247 5mm thick sim pad each
0248 10mm thick sim pad each
0249 10 mm thick Cement Bonded particle board confirming to IS 14276 sqm
0367 Portland Cement (OPC-43 Grade) tonne
0637 Bright finished or black enameled mild steel screws 40 mm 100 Nos
0764 Calcium silicate base compound for jointing calcium silicate tiles kg
0982 Coarse sand (zone III) cum
0983 Fine sand (zone IV) cum
0993 FY-1860 grade wire strands quintal
1012 Pregalvanized high tensile steel confirming to IS:277-199 kg
1021 Hard drawn steel wire fabric 75 x 25 mm mesh of weight not less than 7.75
kg/sqm sqm
645.00
784.00
714.00
470.00
300.00
625.00
170.00
195.00
634.00
789.00
10.00
15.00
25.00
475.00
5000.00
60.00
26.00
1500.00
900.00
5700.00
90.00
430.00
120.00
25.00
1100.00
791.00
30.00
35.00
75.00
50.00
150.00
80.87
160.00
223.00
1248 Epoxy based sealing Compound kg
1253 Polypropylene mechanical fastener with plastic pin confirming to EOTA ETAG
014 (European Technical Approval) having dia 10mm & L=200mm
each
1254 Moisture cure Polyurethane Foam 750 ml
1255 PVC Corner Bead of size 25mmx25mm fixed with glass fibre mesh (100mm x
100mm) metre
1256 Cementitious polymer base coat confirming to EOTA ETAG 004 (European
Technical Approval) kg
1257 Fiberglass mesh with alkali-resistant coating having mass per unit area ?145
g/m2, mesh size: 3.9x4.0 mm ±10% sqm
2636 GI Screws of gauge 10, length 45 mm for fixing cement fibre board to C
section each
500.00
0.14
28.00
34.00
30.00
600.00
90.00
40.00
75.00
50.00
437.15
163.93
187.35
145.72
145.72
163.93
17700.00
134.00
2153.00
32.00
6.00
3.15
3.10
180.00
150.00
60.00
180.00
5747 Factory made single extruded WPC (Wood Polymer Composite)
solid door/window, clerestory windows & other Frames/Chowkhat of frame
size 45 x 70 mm
metre
5748 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 45
x 85 mm
metre
5749 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 50
x 100 mm
metre
5750 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 50
x 125 mm
metre
5751 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 65
x 100 mm
metre
5752 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 65
x 125 mm
metre
5753 Factory made single extruded WPC (Wood Polymer Compos- ite) solid
door/window, clerestory windows & other Frames/ Chowkhat of frame size 65
x 150 mm
metre
5754 Factory made single extruded WPC (Wood Polymer Composite) solid plain
flush door shutter 30mm thick sqm
5755 Factory made single extruded WPC (Wood Polymer Composite) solid plain
flush door shutter 35 mm thick sqm
5756 Factory made single extruded WPC (Wood Polymer Composite) solid plain
white colored board of 18 mm thick sqm
5757 Factory made single extruded WPC (Wood Polymer Composite) solid plain
white colored board of 25 mm thick sqm
5758 Factory made single extruded WPC (Wood Polymer Composite) solid plain
white colored board of 6 mm thick sqm
5759 Factory made single extruded WPC (Wood Polymer Composite) solid plain
white colored board of 12 mm thick sqm
5760 Factory made 18 mm thick single extruded WPC (Wood Polymer Composite)
solid plain white colour board Jali sqm
5762 16mm thick extruded terracotta tiles of grey colour of size 300 x 595mm
sqm
5763 16mm thick extruded terracotta tiles of other than grey colour of size 300 x
595mm sqm
5764 24mm thick extruded terracotta tiles of grey color of size 309x
1190 mm and length 1190mm sqm
5765 24mm thick extruded terracotta tiles of grey color of size 309x 1190 mm and
length 1190mm sqm
7025 Self tapping pan head nickel coated mild steel screws of size 13 x 3.2 mm
1000 Nos
7026 Fibre joint tape 50 mm wide (90 metre) roll each roll
7216 Self-Drilling/Self-Tapping Screws M-6 25mm long each
7217 SS anchor Fasteners (RCC / Brick) – M-8x75mm/M-10x100mm each
7218 MS Polymer Sealant Adhesive litre
7219 SS Double Clip at intermediate each
7220 SS Single clip at top and bottom each
7221 Self-Drilling/Self-Tapping Screws 5.5x25 mm long each
7222 SS Anchor Fasteners (RCC / Brick) – M-8x100 mm each
7224 Concrete hardener kg
7225 Release agent litre
7226 Sealer kg
7227 PU resin top coat kg
375.00
525.00
540.00
630.00
650.00
835.00
1010.00
2800.00
3250.00
1750.00
2360.00
600.00
1020.00
2260.00
125.00
2152.80
1991.30
2475.00
2260.00
190.00
120.00
60.00
22.00
120.00
25.00
180.00
90.00
20.00
15.00
35.00
12.00
830.00
250.00
140.00
480.00
150.00
3.00
70.00
1200.00
7.00
4.00
3.00
70.00
20.00
200.00
260.00
225.00
7274 Glass wool 50 mm thick sqm
7383 12 mm dia 50 mm long wedge type expanded zinc alloy dash fastener
each
7388 Dash hold fastener 12.5 mm dia, 50 mm long with 6 mm dia bolt each
7776 Concrete paver block of grade M-30 made of C&D waste (60mm thickness)
sqm
7930 dowel tubes (Corrugated GI pipes 50 to 80mm dia) (For horizontal joints)
metre
7931 Hooks for lifting (Alloy steel) having 2.5 tonne capacity each
7996 Factory made EPS light weight composite sandwitched wall/ roof panel
(50mm thick) having core material of EPS granule balls/beads (conforming to
IS 4671:1984 and shall have density not less than 15kg per cum). The outer
face on both sides of the panels will be non asbestos fiber cement board
confirming to IS 14862:2000 or Calcium silicate board confirming to EN
14306:2009 of 5mm thick each.
sqm
200.00
29.00
76.00
60.00
845.00
70.00
7.00
10.00
295.00
245.00
160.00
585.00
175.00
25.00
450.00
650.00
110.00
2.00
500.00
45.00
10.00
80.00
31.00
210.00
144.00
270.00
735.25
7997 Factory made EPS light weight composite sandwitched wall/
roof panel (60mm thick) having core material of EPS granule balls/beads
(conforming to IS 4671:1984 and shall have density not less than 15kg per
cum). The outer face on both sides of the panels will be non asbestos fiber
cement board confirming to IS 14862:2000 or Calcium silicate board
confirming to EN 14306:2009 of 5mm thick each
sqm
7998 Factory made EPS light weight composite sandwitched wall/ roof panel
(75mm thick) having core material of EPS granule balls/beads (conforming to
IS 4671:1984 and shall have density not less than 15kg per cum). The outer
face on both sides of the panels will be non asbestos fiber cement board
confirming to IS 14862:2000 or Calcium silicate board confirming to EN
14306:2009 of 5mm thick each
sqm
7999 Factory made EPS light weight composite sandwitched wall/ roof panel
(90mm thick) having core material of EPS granule balls/beads (conforming to
IS 4671:1984 and shall have density not less than 15kg per cum). The outer
face on both sides of the panels will be non asbestos fiber cement board
confirming to IS 14862:2000 or Calcium silicate board confirming to EN
14306:2009 of 5mm thick each
sqm
8000 Factory made EPS light weight composite sandwitched wall/ roof panel
(100mm thick) having core material of EPS granule balls/beads (conforming
to IS 4671:1984 and shall have density not less than 15kg per cum). The
outer face on both sides of the panels will be non asbestos fiber cement
board confirming to IS 14862:2000 or Calcium silicate board confirming to EN
14306:2009 of 5mm thick each
sqm
8013 Factory made EPS Core wallpanel /roof panel sandwiched be- tween two
Engineered welded wire fabric mesh of 3 mm dia G.I. wire mesh,with 50 mm
pitch in both the directions, kept at 120- 135 mm gap and interconnected by
the zig zag G.I. wire of 3 mm dia at alternate row by welding.
sqm
8015 Expanded poly ethylene Foam sheet 4mm thick of Density 40kg/m3 sqm
8016 High Density expanded poly ethylene (EPE) Foam 1mm thick sqm
8019 GI sheet 0.8 mm thick confirming to IS 277:1992 kg
8020 Factory made EPS Core wall panel /roof panel sandwiched be- tween two
Engineered welded wire fabric mesh of 3 mm dia G.I. wire mesh, with 50 mm
pitch in both the directions, connected by G.I. wire of 3mm dia at alternate
row by welding
sqm
8021 Bamboo wood Tile Flooring 14mm thick, minimum 1800 mm length and
minimum 100 mm wide sqm
8022 Bamboo wood Quarter Round 18mm thick of size 1900mm x 18mm metre
8023 Bamboo wood door reducer 14mm thick of size 1900mm x 44mm metre
8024 Bamboo wood Skirting 14mm thick of Size 1900mm x 85mm metre
8025 Bamboo wood Tile Wall Cladding 10mm thick, minimum 1800 mm length and
minimum 100 mm wide sqm
8026 Bamboo wood T-mold 14mm thick of size 1900mm x 44mm metre
8027 Bamboo wood Threshold 14mm thick of size 1900mm x 44mm metre
8028 Bamboo wood shutter of doors 10 cudm
8029 Bamboo wood panelling (10mm thick) 10 cudm
8030 Superior class Bamboo wood door frame 65 mm thick, 10 cudm
8031 Aluminium sheets Grade 5052, 4 mm thick for wall panel/deck panel/WRB
panel/Kicker Panels/door closing panels ( for form work) sqm
8032 Aluminium sheets Grade 5052, 4 mm thick for Internal Corner/ Column
Corners/ ( for form work) sqm
8033 Aluminium sheets Grade 5052, 4 mm thick for Mid Soldier/ End soldier (for
form work) sqm
1074.46
1268.00
1512.37
1650.00
20.00
10.00
90.00
600.00
3470.00
115.00
255.00
300.00
3400.00
250.00
255.00
1700.00
1680.00
1675.00
8500.00
11500.00
32000.00
1400.00
590.00
290.00
1200.00
15.00
55.00
14.00
45.00
3.00
6.00
370.00
990.00
1000.00
480.00
120.00
65.00
60.00
5.00
5.00
30.00
5.00
18.00
8056 Door spacer 45x45x5-1135mm Long each
8145 Bamboo Mat Ridge cap 3.5 to 4mm thick conforming to IS 15476:2004
metre
8553 Mineral fibre beveled tegular edged ceiling tiles 595 x595mm, 16 mm thick
with bio-block conforming to ISO 5 (class 100) specifications.
sqm
8554 Mineral fiber beveled tegular edged ceiling tiles 595 x595mm, 20 mm thick.
sqm
8555 G.I main runner 15 x32 mm of 3000 mm length, 0.33 mm thick each
8556 G.I cross-T 15 x32 mm of 1200 mm length, 0.33 mm thick each
8557 G.I cross-T 15 x32 mm of 600 mm length, 0.33 mm thick each
365.00
320.00
2648.00
2570.00
1508.00
1738.00
2098.00
2688.00
3115.00
300.00
250.00
230.00
150.00
310.00
280.00
180.00
150.00
460.00
42.00
42.00
110.00
220.00
230.00
1800.00
300.00
835.00
925.00
1045.00
190.00
78.00
35.00
8558 G.I hanger rod 6mm dia fully threaded upto 1000 mm length each
8559 Stainless steel U Channel of size (50x25x2mm) metre
8560 Non staining water resistant clear silicon metre
8561 Extruded polystyrene rigid insulation board 50 mm thick sqm
8562 Expanded Polystyrene insulation board 120 mm thick confirm- ing to IS 4671-
1984, Fire retardant property self-extinguishing type as per EN 13501-1
sqm
8563 15 mm thick, light weight, integral densified micro look edged,false ceiling
tiles of size 595x595 mm. sqm
8567 Galvanized mild steel perimeter wall angle 22x19x0.40 mm (3000mm long)
each
8582 12 mm thick micro tegular edged fully perforated GRG (Glass Fibre
Reinforced Gypsum) false celing tiles of Size 595x595 mm sqm
8588 Galavanised MS hanger rod 6mm dia MS fully threaded up to 1000mm length
each
8590 Galvanised Steel main Tee ceiling section Size 24x38x0.33 mm (3 metre
long) each
8591 Galvanised Steel perimeter wall Angle Size 24 x 24 x 0.40 mm (3.00 metre
long) each
8598 GI Metal Tile Clip in Perforated Beveled edge global white colour tiles of size
600x600 mm and 0.5 mm thick sqm
8960 Geosynthetic Drainage with two filtering nonwoven geotextiles having a “W”
configuration as longitudinal parallel channels. Mini- mum thickness to be
7.2mm, with two filtering UV stabilized polypropylene nonwoven geotextile of
minimum thickness of 0.75mm having pores of 150 micron and tensile
strength of 8.0 kN/m and having plane flow capacity of 2.1 L / (m.s) at
hydraulic gradient of 1.0 & 20 kPa pressure,tensile strength of 18 kN/m , with
mass per unit area of 740 gsm.
sqm
8961 Geosynthetic Drainage Composite having thermobonding a drain- ing core -
HDPE geonet comprises of two sets of parallel overlayed ribs integrally
connected to have a rhomboidal shape with a polyethylene film and a
nonwoven geotextile having mass per unit area 130 g/m2 and tensile
strength of 8.0 kN/m having in plane flow capacity of 0.7 L / (m.s) at hydraulic
gradient of 1.0 & 20 kPa pressure and tensile strength of 13.5 kN/m , with
mass per unit area of 830 gsm,
sqm
8962 Synthetic Geogrid having Ultimate tensile strength- 100 kN/m sqm
8963 Synthetic Geogrid Ultimate tensile strength- 150 kN/m sqm
8964 Synthetic Geogrid Ultimate tensile strength- 200 kN/m sqm
8965 Synthetic Geogrid Ultimate tensile strength- 250 kN/m sqm
8966 Synthetic Geogrid Ultimate tensile strength- 300kN/m sqm
8967 Synthetic Geogrid Ultimate tensile strength- 350kN/m sqm
8968 Synthetic Geogrid Ultimate tensile strength- 400kN/m sqm
8969 Synthetic Geogrid Ultimate tensile strength- 500kN/m sqm
8970 Synthetic Geogrid Ultimate tensile strength- 600kN/m sqm
8971 Synthetic Geogrid Ultimate tensile strength- 700kN/m sqm
8972 Synthetic Geogrid Ultimate tensile strength- 800kN/m sqm
8973 Synthetic Geogrid Ultimate tensile strength- 900kN/m sqm
8974 Synthetic Geogrid Ultimate tensile strength- 1000kN/m sqm
8975 Synthetic Geogrid Ultimate tensile strength- 1100kN/m sqm
8976 Synthetic Geogrid Ultimate tensile strength- 1200kN/m sqm
8977 Aluminium profile industrial troughed sheet of Alloy 31500/31000/ 40800,
conforming to IS 1254, IS 737, IS 2676, 0.71 mm thick, the profile detail width
1044/920 mm, cover width 1000/875 mm.
sqm
8978 Aluminium profile industrial troughed sheet of Alloy 31500/31000/ 40800,
conforming to IS 1254, IS 737, IS 2676, 0.91 mm thick, the profile detail width
1044/920 mm, cover width 1000/875 mm.
sqm
8979 Uni Axial Woven polyster geogrid of minimum tensile strength 40KN/m in the
Longitudinal direction and 20 KN/m in the Trans verse direction.
sqm
8980 Uni Axial Woven polyster geogrid of minimum tensile strength 60KN/m in the
Longitudinal direction and 20 KN/m in the Trans verse direction
sqm
8981 Uni Axial Woven polyster geogrid of minimum tensile strength 80 KN/m in the
Longitudinal direction and 30 KN/m in the Trans verse direction.
sqm
8982 Uni Axial Woven polyster geogrid of minimum tensile strength 100KN/m in the
Longitudinal direction and 30KN/m in the Trans verse direction.
sqm
8983 Uni Axial Woven polyster geogrid of minimum tensile strength 120KN/m in the
Longitudinal direction and 30KN/m in the Trans verse direction.
sqm
8984 Uni Axial Woven polyster geogrid of minimum tensile strength 150KN/m in the
Longitudinal direction and 30 KN/m in the Trans verse direction.
sqm
8985 Uni Axial Woven polyster geogrid of minimum tensile strength 200KN/m in the
Longitudinal direction and 30 KN/m in the Trans verse direction.
sqm
8986 Uni Axial Woven polyster geogrid of minimum tensile strength 250KN/m in the
Longitudinal direction and 30KN/m in the Trans verse direction.
sqm
8987 Uni Axial Woven polyster geogrid of minimum tensile strength 300KN/m in the
Longitudinal direction and 30KN/m in the Trans verse direction.
sqm
8988 Bi Axial Woven polyster geogrid of minimum tensile strength 20KN/m in both
Longitudinal and Transverse direction. sqm
8989 Bi Axial Woven polyster geogrid of minimume tensile strength 40KN/m in both
Longitudinal and Transverse direction. sqm
8990 Bi Axial Woven polyster geogrid of minimum tensile strength 60KN/m in both
Longitudinal and Transverse direction. sqm
825.00
725.00
900.00
27.00
260.00
125.00
105.00
50.00
210.00
170.00
80.00
35.00
140.00
18.00
550.00
600.00
750.00
37.00
28.00
685.00
140.00
90.00
45.00
22.00
4.50
1.00
35.00
710.00
800.00
220.00
110.00
130.00
5.00
12.00
10.00
10.00
130.00
80.00
40.00
20.00
10.00
6.00
5.00
10.00
15.00
25150.00
525.00
560.00
22.00
120.00
135.00
205.00
290.00
530.00
630.00
200.00
210.00
340.00
350.00
360.00
370.00
450.00
500.00
550.00
650.00
725.00
850.00
950.00
1000.00
1050.00
600.00
785.00
139.00
161.00
205.00
237.00
254.00
319.00
375.00
458.00
529.00
114.00
173.00
223.00
2.12
2.12
2.12
26.0 NEW TECHNOLOGIES AND MATERIALS
Code No. Description Unit
26.1 Providing & fixing in position Phenol bonded Bamboowood flooring with
planks of sizes 14mm thick, minimum 1800mm length and minimum 100 mm
wide, in approved colour, texture and finish, having Performance Appraisal
Certificate (PAC) issued by Building Materials & Technology Promotion
Council (BMTPC). The flooring shall be fixed with tongue and groove
interlocking system, with underlayment of 4mm thick expanded polyethylene
foam sheets having density 40kg/cum, over prepared surface with necessary
quarter round planks of size 1900mm x 18mm and door reducer of size
1900mm x 44mm, wherever required. The bamboowood planks shall have
minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco
friendly UV coating, all complete as per direction of the Engineer in-charge.
sqm
26.2 Providing & fixing in position Phenol bonded Bamboo wood in wall skirting
with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm
wide(minimum), in approved colour, texture and finish, having Performance
Appraisal Certificate (PAC) issued by Building Materials & Technology
Promotion Council (BMTPC). The skirting shall be fixed with SS screws & rawl
plugs, over underlayment of 4mm thick, expanded polyethylene foam sheets
having 40kg/cum density over prepared surface. The bamboowood planks
shall have minimum density of 1000Kg/cum & minimum Hardness 1000 Kgf.
with Eco friendly UV coating, all complete as per direction of the Engineer
in-charge.
sqm
26.3 Providing & fixing in position Phenol bonded Bamboowood wall cladding at
all height with planks of sizes 10mm thick, minimum 1800mm length and
minimum 100 mm wide, in approved colour, texture and finish, having
Performance Appraisal Certificate (PAC) issued by Building Materials &
Technology Promotion Council (BMTPC), with necesasary profiled edges
fixed with 40mm SS screws 5 nos in each tile to frame work made of second
class teak wood of size 20x15 mm in centre of each tile and bottom and top
of work height, 40x15mm placed at ends of each tile. The cladding shall be
laid over backlayment of 1.00 mm thick expanded polyethylene foam of
density 40kg/cum in two layers, first layer on wall surface before fixing
wooden frame and second layer on frame under cladding. The bamboowood
planks shall have minimum density of 1000 Kg/cum & minimum Hardness
1000 Kgf. with Eco friendly UV coating, all complete as per direction of the
Engineer in-charge.
sqm
26.4 Providing & fixing in position Phenol bonded Bamboowood panelled or
panelled and glazed shutters for doors windows, clerestorey windows with
pre-molded minimum 30mm thick planks, in approved colours, texture & finish.
It shall have 10mm wide, 25mm deep grove to fit in panels.The bamboo wood
shall have minimum density of 1000 Kg/cum, minimum Hardness 1000 Kgf. All
styles and rails shall have profiled interlocking system locked in place by
bamboo pins, all complete as per direction of Engineer in charge. (The
panelling will be paid for separately).
sqm
Rate
5289.05
5191.10
5609.20
5504.70
26.5 Providing & fixing in position Phenol bonded Bamboo wood panelling of
10mm thick, in 25 to 40 mm thick panelled or panelled & glazed shutters for
doors, windows, clerestorey windows, in approved colour, texture & finish.
The bamboowood planks shall have minimum density of 1000 Kg/cum &
minimum Hardness 1000 Kgf. The panels shall have profiled interlocking
system locked in place with bamboo pins all complete as per direction of the
Engineer in-charge. (area of opening for panel inserts excluding portion
inside grooves or rebates to be measured)
sqm
26.6 Providing & fixing in position 65 mm thick factory made door frame of Phenol
bonded Bamboo wood (superior class, interior use), in approved colour,
texture and finish.The bamboo wood shall have minimum density of 1000
Kg/cum, minimum hardness 1000 Kgf. The door frame shall have tenon &
mortise interlocking system, to be fixed to the wall with 100 mm size G.I
screws all a complete as per direction of Engineer-in charge.
cudm
26.6A Providing, erecting, laying and fixing in position in 3.5 to 4 mm thick bamboo
mat corrugated sheet (BMCS) as per IS: 15476-2004 in roofing with self
drilling screws along with EPDM washers complete or with galvanized iron J
or L hooks 8mm dia G.I. plain and bitumen washers etc, all complete as per
direction of Engineer-in-Charge.
sqm
26.6B Providing and fixing in position ridges of 3.5 to 4 mm thick bamboo mat ridge
cap (BMRC) as per IS: 15476-2004 in roofing with self drilling screws along
with EPDM washers complete or with galvanized iron J or L hooks 8mm dia
G.I. plain and bitumen washers etc, all complete as per direction of Engineer-
in-Charge.
metre
26.6C Providing and fixing at all height false ceiling of 4mm thick phenol bonded
Bamboo Mat board (595x595mm) conforming to IS:13958- 1994 including
providing and fixing of frame work made of GI angle 25x25x0.4 mm thick all
around suitably fixed to wall with the help of dash fastener and hanger frame
(600x600 c/c) made GI slotted Tee having powder coating on bottom side
(30x25x0.3 mm thick for main member & 25x25x0.3 mm for cross member)
connected to ceiling with 2.64mm GI wire and anchor fastener at every
junction and also including cost of making openings for light fittings, grills,
diffusers, cut outs made with frame of perimeter channels suitably fixed all
complete as per direction of Engineer-in-charge.
sqm
26.6D Providing and fixing at Bamboo Mat board conforming to IS:13958- 1994 for
partition to frame by bucking or studding with screws etc. complete (Frames,
backing or studding to be paid separately)
26.6D.1 3mm thickness sqm
26.6D.2 4mm thickness sqm
26.6D.3 6mm thickness sqm
26.6D.4 9mm thickness sqm
26.6D.5 12mm thickness sqm
3609.00
255.60
5188.65
4152.45
3375.50
2443.15
2800.10
3339.65
4236.20
4869.90
26.6E Providing and fixing at all height wall panelling with phenol bonded Bamboo
Mat board conforming to IS:13958-1994 including providing and fixing to frame work made
of 50mm x 50mm hardwood plugs including cutting brick work and fixing in cement mortar
and making good the wall etc. and also providing and fixing wooden moulded corner
beading of triangular shape to the junction of panelling etc. with iron screws all complete as
per direction of Engineer-in-Charge.
sqm
26.8 Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of
required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C
578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578
(measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D
1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ? 1% by
volume as per ASTM D 2842, oxygen index of
24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D
3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84
class A, fixed with suitable water based adhesive and fastener, complete in all respect as
per the direction of Engineer-in-Charge.
sqm
26.9 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet
frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated
on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum
and the exposed edges sealed with PVC edge beading of same shade and colour. The
frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed
to wall using Expendable Fastner with necesary stainless steel screws, all complete as per
direction of Engineer-in-charge.
metre
26.10 Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm
nominal thickness of approved shade, quality and make, made from rigid foam sheets
(Single extruded) having density 600 Kg/cum and laminated on both side by laminate
Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of
same shade and colour. The shutter shall be fire retardent
having necessary screw holding capacity. Shutter shall be fixed to frame using
approved hinges with necessary stainless steel screws, all complete as per
direction of Engineer-in-charge.
sqm
26.11 Providing and fixing concealed hinge of approved quality for 19-20mm thick
door with stainless steel screws complete : each
26.12 Supplying & laying of bi-axial extruded high modulus polypropylene geogrid
coforming to MORTH SPECIFICATION for base/sub-base reinforcement having minimum
tensile strength 15kN/m in the longitudinal and transverse direction, with 5kN/m and
7kN/m tensile strength at 2% and 5% strain respectively in the longitudinal and transverse
direction, junction efficiency not less than 95% and with 38mm X 38mm mesh opening.
sqm
26.13 Supplying & laying of bi-axial extruded high modulus polypropylene geogrid
coforming to MORTH SPECIFICATION for base/sub-base reinforcement having minimum
tensile strength 20kN/m in the longitudinal and transverse direction, with 7kN/m and
14kN/m tensile strength at 2% and 5% strain respectively in the longitudinal and transverse
direction, junction efficiency not less than 95% and with 38mm X 38mm mesh opening.
sqm
26.14 Supplying & laying of bi-axial extruded high modulus polypropylene geogrid
coforming to MORTH SPECIFICATION for base/sub-base reinforcement having minimum
tensile strength 30kN/m in the longitudinal and transverse direction, with 10.5kN/m and
21kN/m tensile strength at 2% and 5% strain respectively in the longitudinal and transverse
direction, junction efficiency not less than 95% and with 38mm X 38mm mesh opening.
sqm
26.15 Supplying & laying of bi-axial extruded high modulus polypropylene geogrid
coforming to MORTH SPECIFICATION for base/sub-base reinforcement having minimum
tensile strength 40kN/m in the longitudinal and transverse direction, with 14kN/m and
28kN/m tensile strength at 2% and 5% strain respectively in the longitudinal and transverse
direction, junction efficiency not less than 95% and with 38mm X 38mm mesh opening.
sqm
26.16 Supplying & laying of drainage composite for use behind walls, between two
different fills, alongside drains of road, below concrete lining of canals etc. Geocomposite
for planar drainage, realized by thermobonding a draining core in extruded monofilaments
with two filtering nonwoven geotextiles that may also be working as separation or
protecting layers. The draining three dimensional core will have a “W” configuration as
longitudinal parallel channels. Minimum thickness to be 7.2mm, with two filtering UV
stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75mm
charecteristic opening size (O90) of 110 micron and tensile strength of 8.0 kN/m that will
be working as separation or protecting layer, geocomposite having in plane flow capacity of
2.1 L / (m.s) at hydraulic gradient of
1.0 & 20 kPa pressure and tensile strength of 18 kN/m , with mass per unit area of 740
gsm, supplied in the form of roll for easy transportation to site of work as per detailed
specification all complete as per directions of Engineer in charge.
sqm
26.17 Supplying & laying of drainage composite for use behind walls, between two
different fills, alongside drains of road, below concrete lining of canals etc. having
thermobonding a draining core - HDPE geonet comprises of two sets of parallel overlayed
ribs integrally connected to have a rhomboidal shape with a polyethylene film and a
nonwoven geotextile having mass per unit area 130 gsm and tensile strength of 8.0 kN/m
that will be working as separation or protecting layer, geocomposite having in plane flow
capacity of 0.7 L
/ (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure and tensile strength of 13.5 kN/m ,
with mass per unit area of 830 gsm, at easily accessible location including top and
bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete
and as directed by Engineer - In - Charge.
sqm
26.18 Supplying and laying high strength flexible geogrids (HSFG) as soil
reinforcement / basal reinforcement as per MORTH 3100 and IRC 113, made of high
tenacity polyester core with polyethylene coating with Minimum Long Term Design
Strength (LTDS) of more than 50% of ultimate tensile strength at 30 degree Celcius
corresponding to 12
% strain .
850.65
922.30
399.90
4767.80
115.55
204.55
226.65
329.65
454.75
808.00
955.15
322.30
337.00
528.35
543.05
557.80
572.50
690.25
763.80
837.40
984.60
1094.95
1278.95
1426.10
1499.70
1573.30
26.19.1 0.71 mm thick, the profile detail width 1044/920 mm, cover
width 1000/875 mm. sqm
26.19.2 0.91 mm thick, the profile detail width 1044/920 mm, cover
width 1000/875 mm. sqm
26.22 Providing and fixing false ceiling at all heights with integral densified calcium
silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of
approved texture, design and patterns as per CPWD Specification 2019, to be laid in true
horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron
section of 0.33mmthick (galvanized @ 120 grams per sqm including both
sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of
size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32
mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from
ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm
long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-
shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size
25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or
even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or
size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the
help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S
screws. The workshall be carried out as per specifications, drawing and as per
directionsof the Engineer-in- Charge.
26.22.1 With 15 mm thick Tegular edged light weight calcium sliciate false
ceiling tiles sqm
sqm
26.23 Providing and fixing false ceiling at all heights with integral densified calcium
silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of
approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50
(minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as
per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of
100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level
suspended on inter- locking metal powder coated T-Grid of hot dipped galvanised iron
section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with
6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length
3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate
cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm,
suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per
sqm) i.e. 50 mm long, 8 mm
outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of
size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery
wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work
shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
26.23.1 With 15 mm thick integral densified micro edge light
weight calcium silicate false ceiling tiles sqm 2055.65
26.24 Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of
size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of
85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance
of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially
fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both
sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section
of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy
dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as
to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium
silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size
13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be
duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide
(90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of
Engineer-in-Charge all complete.
26.24.1 With 15 mm thick fully perforated square/butt edge
light weight calcium silicate panels/ tiles sqm 2748.85
26.25 Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate
reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns
having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum).
Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal
conductivity
< 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and
Lsections suitably
fixed according to tile size as per direction of Engineer-in-charge. sqm 1419.00
26.26 Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of
Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of
99%, NRC0.50 to 0.75 as per IS 8225:1987,
983.90
1247.40
1693.65
1820.05
and L-shape level adjuster of
0 mm to be fixed on periphery
y wall S.S screws. The work
arge.
00
psum) false ceiling tiles of
2%, humidity resistance of
Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true
horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick
(galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of
length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size
15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using
galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash
fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2
mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery
wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood
screws. The work shall be carried out as per
specifications, drawing and as per directions of the Engineer-in-Charge.
26.26.1 With semi perforated 12 mm thick micro tegular edged GRG false
ceiling tiles. sqm
26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size
595X595mm of approved texture, design and pattern. The tiles should have Humidity
Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057
w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on
interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick
(galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm,
cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size
15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from
ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer
diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm
length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to
centre along main ‘T’. The system should rest on periphery walls /partitions with the help of
GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed
to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall
S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support
system shall be pre-painted with polyester baked paint, for all heights. The work shall be
carried out as per specifications, drawings and as per directions of the engineer-in-charge.
26.27.1 With 16 mm thick beveled tegular mineral fibre false ceiling tile
(NRC 0.55 to 0.6 sqm
26.27.2 With 20 mm thick beveled tegular mineral fibre false ceiling tile
(NRC 0.7) sqm
sqm
um) to be laid in true
iron section of 0.33mm thick
runners of size 15x32 mm of
ntermediate cross-T of size
from ceiling using
mm outer diameter M-6 dash
evel adjuster of size 85x25x2
mm to be fixed on periphery
0 mm long dry wall wood
1690.45
1760.70
2069.90
2362.10
2189.55
REPAIR AND REHABILITATION ITEMS
26.28 Chipping of unsound/weak concrete material from slabs, beams, columns etc.
with manual Chisel and/ or by standard power driven percussion type or of approved make
including tapering of all edges, making square shoulders of cavities including cleaning the
exposed concrete surface and reinforcement with wire brushes etc. and disposal of
debris for all lead and lifts all complete as per direction of Engineer-In-Charge
sqm
26.31.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg of
approved make sqm
26.32 Providing, mixing and applying SBR polymer (of approved make) modified
Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer
minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-
charge.
Note: Measurement and payment: The pre-measurement of thickness shall be
done just after the surface preparation is completed and Payment under this
item shall be made only after proper wet curing has been done and surface
has been satisfactorily evaluated by sounding / tapping with a blunt metal
instrument and/or the 75mm size cube crushing strength at the end of 28 days
to be not less than 30 N/Sqmm2).
311.95
211.55
104.60
6.65
13.35
121.95
117.75
390.45
26.32.1 12 mm average thickness. sqm
Note: Rates shall be for finished surface area of concrete and shall include the
cost of labour, concrete and appropriate approved Super- Plasticiser for
rendering concrete as flowable and SBR polymer but shall exclude cost of
reinforcement, bond coat, Shear Keys, centering and shuttering, strutting,
propping etc (Payment under this item shall be made only after proper wet
curing has been done and surface has been satisfactorily evaluated by
sounding/tapping with a blunt metal instrument)
26.33.1 50mm thick in Grade M 25 with cement content not less than 330
kg per cum sqm
26.33.2 75mm thick in Grade M 25 with cement content not less than 330
kg per cum sqm
26.34 Providing and laying SBR Polymer modified (of approved make @ minimum 2%
by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g.
columns, pillars, piers, beams etc with concrete having the specified minimum
characteristic compressive strength [with ordinary portland cement, coarse sand and
graded stone aggregate of 10mm maximum size in proportion as per design criteria] with
specified average thickness all-round existing core of RCC member.
Note: Rates shall be for finished surface area of concrete and shall include the
cost of making holes in existing RCC slab, if required, for pouring concrete in
shuttering mould of jacket and appropriate approved Super-Plasticiser for
rendering concrete as flowable self compacting and SBR polymer but shall
exclude cost of reinforcement, bond coat, Shear Keys, centering and
shuttering, strutting, propping etc (Payment under this item shall be made only
after proper wet curing has been done and surface has been
satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
26.34.1 50mm thick in Grade M 25 with cement content not less than 330
kg per cum sqm
26.34.2 75mm thick in Grade M 25 with cement content not less than 330
kg per cum sqm
26.34.3 100mm thick in Grade M 25 with cement content not less than 330
kg per cum sqm
333.00
510.50
1020.95
567.25
850.85
567.25
850.85
1134.45
26.35 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-
comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc.
complete as per directions of Engineer-in- Charge.
(The payment shall be made on the basis of actual weight of approved grout injected.)
kg
26.35.3 Epoxy injection grout in concrete/RCC work of approved make
kg
26.36 Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with
all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-
charge.
26.36.1 Wooven PVC cloth sqm 45.70
26.37 Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting
with coarse sand followed by and including cleaning with oil free air blast as per direction of
Engineer in charge. sqm 370.15
26.38 Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the
specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone
aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at
edges and corners etc. as directed by Engineer- in-Charge
Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for
separately. Payment under this item shall be made only after proper wet curing has been done and surface has been
satisfactorily evaluated by sounding/ tapping with a blunt metal instrument.
26.38.1 25mm thick in Grade M 25 with cement content not
less than 330 kg per cum sqm 678.15
26.38.2 50mm thick in Grade M 25 with cement content not
less than 330 kg per cum sqm 1073.45
26.38.3 75mm thick in Grade M 25 with cement content not
less than 330 kg per cum sqm 1530.30
cturer into cracks/honey-
of nipples after curing etc.
102.85
106.70
793.25
0
gn material by sand blasting
5
mix concrete having the
sand and graded stone
ntering and shuttering at
each
26.40 Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or
other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by
means of "L" shaped mild steel shear key welded with existing reinforcement including the
cost of materials, labour, tool & plants as approved by Engineer-in-charge.
sqm
NEW TECHNOLOGY ITEMS
26.41 Designing, providing, installing and fixing factory finished custom designed
cold form Light Gauge Steel Framed super structure comprising of steel wall panel,
trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design
requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy
coated steel having minimum yield strength 300-550 Mpa) conforming to AISI
specifications and IBC 2009 for cold formed steel framing and construction and also as per
IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of
IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially
available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit
architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty
Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong
Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability.
The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm
flange x 11mm lip in required length as per structural design requirement duly punched
with dimple/ slot at required locations as per approved drawings. The slots will be along
centre line of webs and shall be spaced minimum 250mm away from both ends of the
member. The frame can be supplied in panelized or knock down condition in specific
dimensions and fastened with screws extending through the steel beyond by minimum of
three exposed threads. All self drilling tapping screws for joining the members shall have a
Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of
gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie
beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per
approved drawings. design subject to minimum 12mm diameter and 121mm length
conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in
RCC (RCC to be paid separately) and located not more than 300mm from corners or
termination of bottom tracks complete in all respects. The item also includes the
submission of stability reports duly examined and issued by any NIT/IIT. The rate includes
the concept design, detailed design, fabrication of sections, transportation, installation and
all required fixing arrangement at site as described above.
kg
202.70
820.80
235.70
26.42 Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as
per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to
3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered
pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45
mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self-
drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh
tape and epoxy and acrylic based jointing compound for seamless finish.(cost
of frame work to be paid for separately)
26.42.1 Outer face: Outer face having 6mm thick fiber cement board fixed
on 9mm thick fiber cement board, Type A, as per IS:14862:2000 (high
pressure steam cured) Inner Face :- 12.5 mm thick gypsum plaster board
conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board confirming
to IS:14862:2000 of type B (High pressure steam cured)
sqm
26.42.2 Outer face: Outer face having 8 mm thick cement bonded particle
Board fixed on 10 mm thick cement bonded particle board. (Termite, Fire and
Moisture Resistance) as per IS 14276:1995. Inner face:-12.5 mm thick gypsum
plaster board conforming to IS 2095:2011 fixed on 8 mm thick cement bonded
particle board (Termite, fire and moisture resistance) confirming to
IS:14276:1995)
sqm
26.43 Providing and fixing internal wall panels on Light gauge steel frame work with
12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board
as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of
approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to
10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using
fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost
of frame work to be paid for separately
26.44 Providing and fixing in all exterior face panels breathable vapour barrier
underneath the cement fiber board as per National Building Code 2009 complete as per
direction of Engineer-in-charge.
sqm
26.45 Supplying and installation of moisture resistant/fire resistant cement board as
per standard sizes fixed with self-drilling / taping screws. Screws shall be of counter sunk
rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm.
uter face cement boards as
make. A groove of 2 mm to
hall be fixed in a staggered
length varying from 25 to 45
dard sizes fixed with self-
be done using fiber mesh
3485.20
2764.05
2170.40
1920.20
304.90
26.45.1 Cement Fiber Board 6 mm thick as per IS 14862:2000 of type B
(High pressure Steam Cured) sqm
26.46 Providing and fixing in position, 200 mm thick factory made Expanded
Polystyrene Core (EPS Core) wall panels consisting of EPS core sandwiched between two
Engineered sheets of welded wire fabric mesh duly finished with shortcrete materials on
outer faces. The fabric mesh shall be made of 3 mm dia G.I. wire mesh with 50 mm pitch
in both the directions and on both faces of the wall, kept at 120-135 mm gap and
connected by the zig zag G.I. wire of 3 mm dia at alternate row by welding (at an angle
ranging from 50-70 degree) . The EPS core shall consist of 100 mm thick EPS of density
not less than 20 kg/ per cum. Both the outer faces of the panel shall be finished by
applying the layer of 50 mm thick cement mortar 1:3 {1 cement: 3 coarse sand (not having
more than 40% stone chips of size upto 6 mm)} À with the help of shotcreting/guniting
equipment etc at a pressure not less than 1 bar (100Kn/m2) and both surfaces finished
with trowel. Fixing operations of wall panels shall be completed in all respect as per
drawings and specifications and under the overall direction of the Engineer-in-charge.
sqm
26.47 Providing and fixing in position, 230mm thick factory made Expanded
Polystyrene Core (EPS Core) roof/floor panels made of 3 mm dia
G.I. wire mesh with 50 mm pitch in both the directions and on both faces of panel, kept at
120-135 mm gap and connected by the zig zag G.I. wire of 3 mm dia at alternate row by
welding (at an angle ranging from 50-70 degree). The EPS core shall consist of 100 mm
thick EPS of density not less than 20kg/ per cum. The bottom side of the panel shall be
finished by applying a layer of 60-65 mm thick cement mortar 1: 3 {1 cement: 3 coarse
sand (not having more than 40% stone chips of size upto 6 mm)} À with the help of
shotcreting equipment etc at a pressure of not less than 1 bar (100Kn/m2) and surface
finished with trowel. The top face of the panel shall be provided and finished by applying
70-75 mm thick layer of cement concrete 1:1.5: 3 (1 cement :1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size). Fixing operations of roof/floor panels shall be
completed in all respect as per drawings and specifications and under the overall direction
of the Engineer-in-charge.
sqm
26.48 Providing and fixing of customized Aluminium form work for monolithic
construction on RCC members with repetitive usage made up of aluninium sheets/plates of
minimum 4mm thickness and grade 6061 (Type-6). The formwork comprises of (a) wall
panel, roccker, kickerand internal soffit corner, external soffit corner, external corner,
internal corner etc., (b) beam components i.e, beam side panel prop head for soffit beam,
beams soffit panel, beam soffit bulk head and (c) deck components i.e. deck panel, deck
prop, prop length, deck mid, soffit length, deck beam bar. The panels are held in position
by a simple pin and wedge system that passes thorugh holes in the out
side rib of each panel. The tolerance of finished panel shall not be less than (-1
mm) and shall conform to IS 14987-1999. Pins and wedges to be made of high
grade hot dipped galvansied mild steel. This form work also comprises of M.S.
angle iron, "Z" shaped brackets braced diagonally at 0.90 to 1.00 mtr. centre to
centre on extrenal wall face just the level below on which to lay M.S. square
tube panels (Challis) and guard railing supports to form working platform and
40 mm dia G.I. telescopic adjustable props to support deck formwork and
beam soffit panels including de-shuttering the formwork from odd/even level to
be shifted/lifted to next alterante odd/even level before which the points and
shuttering surface to be thoroughly cleaned, pins greasing and shuttering
surface oiling propoerly before fixing all complete including sealing of gap
between kicker plates of wall panel and floors (if any) as per design of
formwork as provided by shuttering supplier and as per direction of the
Engineer-in-charge including filling and finishing the holes of varied sizes and
shapes (left by keys/pins of aluminium form work shuttering while de-
shuttering) with GP-2 cementeous polymer compound mixed with water in ratio
prescribed by manufacturer to form consistent workable dough for pushing it in
the holes upto full depth of wall using appropriate tools and finishing smooth all
complete as per directions of the Engineer-in-charge.
sqm
26.49 Providing and fixing in position factory made EPS cement sandwich
wall/roof/floor light weight solid core panels made of core material of EPS granule
balls/beads (conforming to IS 4671:1984 and shall have density not less than 15kg per
cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed
to form in a preset mould. The outer face on both sides of the panels will be non asbestos
fiber cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN
14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement:
2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall be
preferably fixed into 'C' channel made of 1.2mm thick MS plate screwed/fastenened to the
slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and
horizontally locked with steel bar between each other and floors and filled with cement
mortar and adhesive. Panels should be used as floor & roofing with additional structural
support, steel or RCC depending upon the design. All the operation shall be completed in
all respect as per drawings, Manufacturers specifications and under the overall
direction of Engineer-in-Charge (Cost of all the material is included except "C channel"
which will be paid seperately).
26.49.1 Non load bearing panels 50mm thick of required size sqm
26.49.2 Non load bearing panels 60mm thick of required size sqm
26.49.3 Non load bearing panels 75mm thick of required size sqm
26.49.4 Non load bearing panels 90mm thick of required size sqm
26.49.5 Non load bearing panels 100mm thick of required size sqm
26.50 Providing and fixing in position factory made non asbestos fibre reinforced
aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight
cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp
& Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on
both sides of the panels will be non asbestos fibre cement board confirming to IS
14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C
channel of 1mm thick of required sizes as recommended by manufacturer's and fixed to
floor and RCC soffit in plumb to each other with steel screw/ fasteners. The panel shall be
fixed vertically with tongue & groove joint with cement based polymer modified jointing
compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer
based jointing compound having superior flexibility. Panels should be used as floor &
roofing with additional structural support, steel or RCC depending upon the design. All the
operation shall be completed in all respect as per drawings, Manufacturers specifications
and under the overall direction of Engineer-in-Charge (Cost of all the material is included
except "tracks/C channel" which will be paid separately).
26.50.1 Non load bearing panels 50mm thick of required size (minimum
4mm thick fibre cement board) sqm
26.50.2 Non load bearing panels 75mm thick of required size (minimum
5mm thick fibre cement board) sqm
26.51 Supplying of standard quality GFRG panel of 124 mm thickness with modular
cavities purchased from GFRG panel manufacturing plant in the country, cut to required
wall sizes and floor/ roof slab sizes in correct length and height, including cutting of door,
window and ventilator opening as per the cutting drawing prepared by architects
/design engineers for the construction of GFRG building and loaded in stillages for
transportation to the construction site. Cost of panel includes security deposits, hire
charges of stillages & jaws, cost of transportation in trucks/ lorries without any damages
upto 300kms including all leads and lifts from GFRG manufacturing plant to construction
site and unloading at site using suitable fork lift/ crane. (Payment shall be made on the
basis of area of one side of panel without reduction of opening of door/ window /
ventilator). For transportation above 300kms, additional charges to be paid.
sqm
26.52 Erection of GFRG Panels in walls in all floors using suitable crane as per
instructions of Engineer-in-Charge, as per cutting drawings and structural drawings, in
perfect line and plumb, above RCC plinth beam/GFRG panel below and provide necessary
lateral/ slanting support to keep the wall panel in safe position, providing & tieing of
Reinforcement as per structural drawings and applying a coat of water repellant coating
Zycosil/equivalent or equivalent product (1 Zycosil/equivalent compound :10 water ) to
saturation level over RCC plinth beam to provide water proofing treatment to joint between
wall panel & plinth beam as per the guide lines / instruction by the engineer in charge.
(Cost of reinforcement, water proofing of walls and plinth beam/GFRG panel below joints
and installation of door/ window frames
before filling of concrete shall be paid separately). The rate quoted shall
include making provision for laying of lintels, beams, sunshades, staircase
beams, lofts, plumbing work, electrical conduits and any structural insertion
etc., as per the drawing and direction of the engineer in charge. The payment
shall be made based on the actual exposed area (one side only) of the
panel.The work shall be carried out as per the Special Conditions For Glass
Fibre Reinforced Gypsum (GFRG) Structures mentioned in NIT.Note: i) When
cutting panel, “A” side is to be for outside or external surface of respective
external wall and B side is to be for internal surface of wall ii)Erection of panel
is to be with reference to both building plan & cutting drawing by following
notational mark indicated in the cutting drawing as well as notional mark written
on each panel cut as per cutting drawing
sqm
26.53 Filling of empty cavities (as shown in the structural design drawing) with quarry
dust mixed with 5% cement (by volume). After initial infill of 50 mm thick with M25 concrete
at base/bottom of cavities to seal off, infill wall panel cavities in 3 stages as detailed below,
(i) 1st pour
/ infill to be limited to 0.3 to 0.50 m height from bottom of the panel.(ii) 2nd Pour/ infill:
infilling shall be done only after 90 minutes interval between successive pours. The
maximum height of infill shall be restricted to 1.5m height or up to the top level of door /
window.(iii) 3rd pour/infill: After an interval of 90 minutes of second pour, infill or pour the
balance height up to the bottom of embedded RCC tie beam. Pour enough water just
required to dampen the dry mix enough to form cake form after each stage.(cost of laying
M25 concrete shall be paid separately)(If any rain falls in between any stages of concrete
pour, make sure to cover the panel top to prevent ingress of water or water falling into the
cavities. In case of water collection over the concrete inside the panel, drill 10mm hole in
GFRG panel immediately above concrete filled level to drain out water before pour/in-fill of
balance concreting)
cum
26.54 Laying of GFRG panel as roof / floor slab panel and staircase panel using
suitable crane as per instructions of Engineer-in-Charge, including providing support
system with 25mm x 300mm-400 mm wide plywood, as runner with proper prop below
proposed micro beams including(a) Cutting of top flange of panel to 180 mm wide (leaving
25mm projection on either side) to provide RCC embedded micro beam as per cutting
drawings and structural drawings. (b) Reinforcement for micro beams and tie beams to be
provided in position with proper anchorage as per structural drawings. (c) Provision
for Electrical cabling, fan hooks and laying of pipes for plumbing work. (d) Concreting of Tie
beam, micro beam and top of GFRG panels (50 mm thick) with M-25 cement concrete mix
using coarse aggregate of size less than 20 mm including laying of 10 gauge 100x100 size
weld mesh with 25 mm effective cover from the panel top.
sqm
26.55 Supplying and fixing 10 Gauge weld mesh of size 100mm x 100 mm for
floor/roof slab concrete screed over the micro beams as reinforcement. The weld mesh
shall be fixed as per drawing.
sqm
1226.20
850.90
3957.45
4286.85
924.60
1182.15
1336.30
1658.70
1930.55
2273.85
1357.75
1575.50
1309.05
234.80
2375.90
238.45
236.00
26.56 Application of ZMB 60/equivalent solution (100 Kg ZMB 60/equivalent, 1 litre
ZMB Nano Thinner, 20 litre water & 1 Litre Zycoprime/equivalent
= 122 litre/kg) over already applied coat of Zycosil/equivalent &
Zycoprime/equivalent solution on the top of all the RCC plinth beams by
brush/spray coat before erection of GFRG over RCC plinth beams in GF. In
the case of upper floors 150 mm wide on floor slab for all the external walls,
bath/toilet/wet areas (3 hrs drying time) before erection of wall panel on upper
floors including erection of parapet wall.
sqm
26.57 After erection of GFRG wall panels, seal all GFRG wall joints with paper tape
temporarily. Water proofing treatment of vertical joints with Zycosil/equivalent
water proofing Solution (1 litre of Zycosil/ equivalent & 20 litres of water
stirred first & 2 litres of Zycoprime/ equivalent added and stirred (total 23
litres)) with 50 ml syringe till the gap and in filled concrete is completely
saturated. After removing the paper seal, seal off the vertical joints with water
proofing material "Grout RW/equivalent " (Sealing cost excluded.)
metre
26.58 Filling of joints between RCC plinth beam / floor slab and wall panel of
external walls, toilet / bath room / wet areas walls on all floor and parapet wall
over roof slab, stair case head room at the time of erection of GFRG panels
with Grout RW/equivalent sealant compound after the erection of panel
before the infill of concrete in panel cavities and fine finish. This applies for all
horizontal and vertical joints between GFRG wall and slab panels.
metre
26.59 Water proofing treatment of Vertical joints (of external side and internal side)
between door frame, window & ventilator frames (on all four sides) of outer
wall over the Zycosil/equivalent & Zycoprime/equivalent solution already
applied (before the installation of door / window / ventilator frames in position)
and fine finish with Grout RW/equivalent.
metre
26.60 Water proofing treatment of RCC sunshade with Zycosil/equivalent water
proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first &
2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets
the saturation level and testing as per RILEM or by water drops test in which
water drops do not absorb but drops remain or rolls.
sqm
26.61 In-filling / sealing of joint between RCC lintel cum sunshade and wall (on
external side) in all floors by pushing in Grout RW/equivalent in paste form
and coving 20 mm x 20 mm after applying a coat of Zycosil/equivalent &
zycoprime/equivalent solution before cement plastering of top, bottom and
sides of RCC sunshade.
metre
26.61 In-filling / sealing of joint between RCC lintel cum sunshade and wall (on
external side) in all floors by pushing in Grout RW/equivalent in paste form
and coving 20 mm x 20 mm after applying a coat of Zycosil/equivalent &
zycoprime/equivalent solution before cement
plastering of top, bottom and sides of RCC sunshade.
metre
302.20
85.15
41.55
42.35
135.80
42.35
42.35
26.62 Designing, Providing, installing and fixing factory finished customed design
pregalvanized high tensile steel joists manufactured from G350 Z275 confirming to IS:277-
1992, minimum coating of galvanizing 275 gm/sqm, minimum yield stress 35 MPa &
minimum tensile strength of 380 MPa placed 1.23 metre apart to support the load of slab
etc as per the design & directions of Engineer-in-Charge.
kg
26.63 Providing and fixing special adjustable lockbars of mild steel E-250 to support
the temporary plywood for work between joists during construction as per design &
directions of the Engineer-in-charge.
kg
26.64 Centering and shuttering with 12mm thick shuttering plywood confirming to
IS 4990:2011 and removal of form at all heights. Plywood will be supported on lock bars.
26.65 Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet
confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm
laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be
supported on structural steel beam with shear studs. (Structural steel like Beam, column,
joists etc. & concrete of different grade as per design will be paid separately).
sqm
26.66 Providing and fixing in position, 130 mm thick factory made Expanded
Polystyrene Core (EPS Core) wall panels consisting of EPS core sandwiched between two
Engineered sheets of welded wire fabric mesh duly finished with shortcrete materials on
outer faces. The fabric mesh shall be made of 3 mm dia zinc coated G.I. wire mesh with 50
mm pitch in both the directions and on both faces of the wall and connected by GI wire of
3mm dia at alternate row by welding. The EPS core shall consist of 60 mm thick EPS of
density not less than 16 kg/ per cum. Both the outer faces of the panel shall be finished by
applying the layer of 35 mm thick cement mortar 1:3 {1 cement: 3 coarse sand (not having
more than 40% stone chips of size upto 6 mm)} with the help of shotcreting/guniting
equipment etc at a pressure not less than 1 bar (100KN/m2) and both surfaces finished
with trowel. Fixing operations of wall panels shall be completed in all respect as per
drawings and specifications and under the overall direction of the Engineer-in-charge.
sqm
26.67 Providing and fixing of external thermal insulation and composite system with
First layer of self-extinguishing type Expanded Polystyrene (EPS) insulation boards of
120 mm thick ( max 1mX0.5m section), confirming to IS 4671:1984, having thermal
conductivity of
0.034 W/mK, (measured as per IS 3346-1980), density of 20-24 kg/ m³ measured as per IS
5688-1982, Fire retardant property self- extinguishing type as per EN 13501-1, bonded
with special polymer modified cementitious adhesive confirming to EOTA ETAG 004
(European Technical Approval) formulated to bond polystyrene insulation boards to
typical mineral substrate (according to ETAG
004) and Polypropylene mechanical fasteners with plastic pin
confirming to EOTA ETAG 014 (European Technical Approval) having dia
10mm & L=200mm on finished level wall and the junction between two
adjacent EPS boards to be sealed with low expansion moisture cure
Polyurethane Foam. Second layer consists of Fiberglass mesh covered with
alkali-resistant coating, mass per unit area ?145 gm/ m², mesh size: 3.9x4.0
mm ±10% embedded in special polymer modified cementitious Base Coat with
hydrophobes and the corners will be protected with Corner-beads with alkali-
resistant mesh wings at least 10 cm wide, mesh mass per unit area min 145
gm/m². The surface will be levelled, finished, made smooth complete in all
respect as per manufactures specification and as per directions of Engineer-
in-Charge.
sqm
26.68 Providing and laying factory made Precast concrete solid blocks of 200 mm
thickness of grade M10 made of C&D waste from approved manufacturer in foundation
and plinth in:
26.68.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum
26.69 Providing and laying factory made Precast concrete solid blocks of 200 mm
thickness of grade M10 made of C&D waste from approved manufacturer in superstructure
above plinth level up to floor V level
26.69.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum
26.70 Providing and laying half block masonry with factory made Precast concrete
solid blocks of 100 mm thickness of grade M10 made of C&D waste from approved
manufacturer in foundation and plinth in:
26.70.1 Cement mortar 1:4(1 cement : 4 coarse sand) sqm
26.71 Providing and laying half block masonry with factory made Precast concrete
solid blocks of 100 mm thickness of grade M10 made of C&D waste from approved
manufacturer in superstructure above plinth level up to floor V level:
sqm
PREFAB/PRECAST TECHNOLOGY
26.73 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25
to 30%) of different thickness & modular width 1200 mm in Controlled Factory
Environment with approved methodology confirming to IS 10297:1982 by using long line
casting method having arrangement of proper steel bed. Concreting should be done by
batch mixing plant capable of producing zero slump concrete, transported through
automatic shuttels of standard make & layed on bed with the help of extruder/Slipformer,
finishing, curing and also provision of steam curing. Cutting, making necessary
cutout/holes of required
141.45
22.35
90.60
1630.40
2415.85
3493.05
6057.95
8086.60
733.35
913.60
757.00
sizes for services in slab element after achieving required strength, yard handling & stacking all complete as per
approved shop drawings & design mix as per the direction of the Engineer-in-charge. (Cost of strands should be
paid separately).
Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable
separately)
26.73.1
mix is payable/recoverable
1252.95
1449.35
1767.40
2157.65
2652.75
3147.85
3642.95
4138.05
17.25
20.70
25.85
32.15
40.20
48.25
56.30
64.35
27.60
33.05
41.35
51.45
64.35
77.25
89.75
102.95
26.74 Fabrication and manufacturing of solid precast concrete element with provisions
of shear keys, connecting loops, dowel tubes and proper lifting accessories for walls,
beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete
grades manufactured in controlled factory environment with approved methodology
including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical
moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing,
transporting and placing of concrete, vibrating, curing, finishing, making necessary
cutout/holes of required sizes for services, yard handling & stacking all complete as per IS
11447:1985 and as per approved shop drawings and design mix as per the direction of
Engineer-in-Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing inserts
will be paid separately).
26.74.3 Extra for using M-50 (Cement content 425 kg) instead of M-35
cum
26.74.4 Extra for using M-60 (Cement content 440 kg) instead of M-35
cum
26.75 Providing & laying in position Prestressing steel strands (low relaxation)
on hollow core bed by using mechanical pulling arrangement like Rabbit/ Bed master
including all accessories for Stressing & destressing operations as per approved make
conforming to IS1343 & grade FY-1860 etc, complete as per drawings and direction of
Engineer -in-charge.
kg
26.76 Transportation of Precast Elements by flat bed Trailor (Double / Triple axle 40ft
Length with proper accessories like A frame etc) from factory, including the cost of
loading , unloading & stacking at site with the help of required capacity cranes.
229.80
421.35
536.25
147.05
464.80
103.00
169.65
288.05
2284.75
26.78 Providing & Applying weather proof sealant on outer joints of approved
make confirming to IS & directed by Engineer-in-charge.
26.78.1 Sealant 25mmx10mm at joints metre
26.79 Providing & Laying of levelling sim pads required sizes (5x5cm to 10x10cm) of
PVC / Rubber to adjust level of bearing surface of supporting members as per the direction
of Engineer in charge.
kg
26.81 Providing and fixing Scaffolding net of required width made of high density
Polyethylene UV stabilized knitted on warp knitting machines having density
100grams/sqm and shading coefficient minimum 75% around the construction site/ for
vertical extension as per requirement including fastening/tying with building/scaffolding
pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One
time payment shall be made for providing Scaffolding net from start of work till completion
of work including shifting if any. The Scaffolding net shall be the property of the contractor
on completion of the work)
sqm
26.82 Providing and laying rigid EPS (cellular plastic material) blocks conforming
to ASTM standards/specifications of minimum density
21.60 Kg/cum on floors, steps, stage etc. of required size and shape as per direction of the
Engineer-in-Charge. This shall include the following operation. “The EPS blocks shall be
cut to required shape and sizes including cuttings for passing of services, joined together
with synthetic resin adhesives as per relevant specifications and packed/placed in position
for stepped floor or platform formation. The top and sides surfaces to be provided with GI
woven wire mesh of aperture 5.45 mm (with wire dia 0.90 mm) secured to EPS blocks with
wire pins/clips. Horizontal top surface to be provided with 20 mm thick cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate upto 6mm chippings) and
vertical surface to be provided with 12mm cement plaster 1:4 (1 cement : 4 coarse sand).
The concrete/plastered surfaces so prepared shall be scratched with wire brushes to form
burrs, so as to act as base for flooring or veneering/panelling to be done later as per
approved design (which shall be paid for separately complete as per direction of the
Engineer-
in-Charge.
sqm
152.50
24.30
31.00
44.35
76.70
25.10
2027.65
26.83 Applying stamping finish to the top surface of freshly laid plain/ reinforced
cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open
yards as per direction of the Engineer- in-Charge. The process shall include the following:-
• The concrete shall be placed and screeded to the finished grade, and
floated to a uniform surface by using standard finishing techniques. The
approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface
of the fresh concrete by the dry shake method by sprinkling in two or more
shakes, floated after each shake and trowelled only after the final floating. The
approved release agent @ 0.113 kg/sqm shall be applied evenly to the
trowelled surface before stamping or the said release agent can be applied to
the flexible polyurethane stamp moulds of approved design and in required
sizes to achieve final stamped pattern. These stampings shall be placed on the
surface of concrete in three to four pieces at a time and tapped gently with
rammers of sufficient size & weight to leave proper stamp marks and the
process repeated for the remaining concrete surface till the whole surface to be
stamped is completed within the time while concrete is in plastic stage of
setting.
sqm
26.84 Supplying and laying of Uni-Axial Woven Polyster Geogrid conforming to
MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement including
accessories like tie-strips, nuts & bolts and loops/lugs for joining reinforcing elements with
the facia pannels, overlaps and other protective elements for synthetic geo-grids and all
other activities required for reinforced soil walls, slopes etc complete as per design
requirements, manufacturer specifications and as per direction of engineer-in- charge.
sqm
26.84.2 Uni Axial Woven polyster geogrid of minimum tensile strength
60KN/m in the Longitudinal direction and 20 KN/m in the Transverse direction.
sqm
26.84.3 Uni Axial Woven polyster geogrid of minimum tensile strength 80
KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.4 Uni Axial Woven polyster geogrid of minimum tensile strength
100KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.5 Uni Axial Woven polyster geogrid of minimum tensile strength
120KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.6 Uni Axial Woven polyster geogrid of minimum tensile strength
150KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.7 Uni Axial Woven polyster geogrid of minimum tensile strength
200KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.8 Uni Axial Woven polyster geogrid of minimum tensile strength
250KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.84.9 Uni Axial Woven polyster geogrid of minimum tensile strength
300KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
sqm
26.85 Supplying and laying of Bi-Axial Woven Polyster Geogrid conforming to
MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement of granular road
base and sub base, area stalilization, track bed stabilization, load transfer platforms
Including accessories like tie- strips, nuts & bolts and loops/lugs for joining reinforcing
elements with the facia pannels, overlaps and other protective elements for synthetic geo-
grids and all other activities required etc. complete as per design requirements,
manufacturer specifications and as per direction of engineer-in- charge.
sqm
26.85.2 Bi Axial Woven polyster geogrid of minimum tensile strength
40KN/m in both Longitudinal and Transverse direction.
sqm
26.85.3 Bi Axial Woven polyster geogrid of minimum tensile strength
60KN/m in both Longitudinal and Transverse direction.
sqm
26.86 Providing and fixing factory made single extruded WPC (Wood Polymer
Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising
of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum
toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent
cement and screwed with full body threaded
640.20
223.25
254.15
315.95
360.90
384.80
476.10
554.75
671.35
771.10
188.10
271.00
341.25
star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N
(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and
resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture
proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and
length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid
for separately).
Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile
shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on
this account shall be made.
644.70
832.95
853.00
973.40
1000.15
1247.70
1481.85
3954.00
4556.05
fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick
of approved design pasted with hot melt adhesive on both faces of shutter and
fixing with stainless steel butt hinges of required size with necessary full body
threaded star headed counter sunk S.S screws, all as per direction of
Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S
screws shall be paid separately)
2714.15
3530.30
982.00
1543.95
er Composite) solid plain
of virgin polymer of K
usk/wheat husk) and non
um and screw withdrawal
0 N/mm2 and resistance to
e proof and fire retardant and
ing applying a priming coat
necessary stainless steel
(mild steel) framework with
5
ventilated rainscreen tiles of
Flexural Strength/ Modulus of
(E) and ISO 10545-3:1995
ng of vertical 'T' (for
40x60x2mm/ 40x40x2mm
horizontal aluminium 'C'-
at wall ends/ corners fixed on
id with two numbers of self-
ular' sections shall be fixed to
0 microns)of size 110x80x6
nd stainless steel grade
expansion anchor fasteners
tion. The brackets shall be of
te points of vertical profiles
ng/ self-tapping SS screws of
cal profiles. The tiles shall be
he tiles shall be additionally
rted and pressed into position
horizontal ‘C’ clamps by using MS Polymer sealant adhesive. The vertical joint open groove between two
adjacent tiles shall be 5mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3)
according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision
for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out
as per specification, drawing and as per direction of the Engineer-in-Charge. Note : Scaffolding wherever
required to be paid separately.
26.92.1 With 16mm thickness (+/- 10%) terracotta tiles of grey colour
sqm
26.92.2 With 16mm thickness (+/- 10%) terracotta tiles of other than grey
colors sqm
26.93 Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of
height 259/ 309/ 409mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus
of Rupture of ? 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995
respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for
intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm
respectively, spaced at maximum spacing of 1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-
clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed
on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of
self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be
fixed to the wall using HDG (hot-dip-galvanized) steel L- brackets (galvanizing thickness of minimum 80 microns) of size
110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer corners and stainless steel
grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor
fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets
shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical
profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS
screws of size 5.5x25 mm with EPDM washers.“EPDM gaskets to be fixed in between brackets and vertical profiles. The
tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be
mounted on the C- clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both
ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and system shall be designed to
resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the
n groove between two
oad as per IS 875 (Part 3)
reen principle with provision
The work shall be carried out
: Scaffolding wherever
5475.30
5248.40
26.93.1 With 24mm thickness (+/- 10%) terracotta tiles of grey colour
sqm
26.93.2 With 24mm thickness (+/- 10%) terracotta tiles of other than grey
colors sqm
COEFFICIENTS
FOR CEMENT CONSUMPTION
tween the façade tiles and
as per direction of the
5585.15
5283.15
ON
3.0 MORTAR
Code Description Unit Quantity of cement
No.
3.15 White cement mortar 1:2 (1 white cement : 2 marble dust). cum
3.16 White cement mortar 1:3 (1 white cement : 3 marble dust). cum
3.17 White cement mortar 1:5 (1 white cement : 5 marble dust) cum
* white cement
COEFFICIENTS FOR CEMENT CONSUMPTION S.H. : 3.0 MORTAR
10.20
6.80
5.10
3.80
3.10
2.50
6.80
5.10
3.80
3.10
2.50
6.80
6.80
3.10
6.80*
5.10*
3.10*
20
ggregate (RCA)) : 6 graded stone
20
stone aggregate 40 mm
20
ggregate (RCA)) : 6 graded stone
20
4.1.8 1:4:8 (1 Cement : 4 coarse sand derived from
natural sources : 8 graded stone aggregate 40 mm nominal size
derived from natural sources)
cum
4.1.8A 1:4:8 (1 Cement : 4 manufactured sand derived from Recycled
Concrete Aggregate (RCA)) : 8 graded stone aggregate 40 mm
nominal size derived from Recycled Aggregate (RA))
cum
4.1.10 1:5:10 (1 cement : 5 coarse sand derived from natural sources :
10 graded stone aggregate 40 mm nominal size derived from
natural sources)
cum
4.1.10A 1:5:10 (1 Cement : 5 manufactured sand derived from Recycled
Concrete Aggregate (RCA)) : 10 graded stone aggregate 40 mm
nominal size derived from Recycled Aggregate (RA))
cum
4.1.11 1:5:10 (1 cement : 5 fine sand derived from natural sources: 10
graded stone aggregate 40 mm nominal size derived from natural
sources)
cum
4.1.12 1:2:3½:9 (1 ordinary portland cement : 2 Fly ash : 3½ coarse
sand derived from natural sources : 9 graded stone aggregate 40
mm nominal size derived from natural sources)
cum
4.1.12A 1:2:3½:9 (1 ordinary portland cement : 2 Fly ash : 3½
manufactured sand Recycled Concrete Aggregate (RCA) : 9
graded stone aggregate 40 mm nominal size derived from
Recycled Aggregate (RA))
cum
4.1.13 1:2½:4:11 (1 ordinary portland cement : 2½ fly ash
: 4 coarse sand derived from natural sources: 11 graded stone
aggregate 40 mm nominal size derived from derived from natural
sources
cum
4.1.13A 1:2½:4:11 (1 ordinary portland cement : 2½ fly ash
: 4 manufactured sand Recycled Concrete Aggregate (RCA):
11 graded stone aggregate 40 mm nominal size derived from
Recycled Aggregate (RA))
cum
4.2 P/L cement concrete - all works upto plinth level :
4.2.2 1:1½:3 (1 cement:1½ coarse sand derived from natural sources :3 graded stone aggregate 20 mm
nominal size derived from natural sources) cum 4.00
1.70
1.70
1.30
1.30
1.30
1.70
1.70
1.30
1.30
regate 20 mm
4.2.2A 1:1½:3 (1 cement:1½ coarse sand inlcuding
manufactured sand derived from Recycled Concrete Aggregate
(RCA) upto 25%: 3 graded stone aggregate 20 mm nominal
size Recycled Concrete Aggregate (RCA) upto 25%)
cum
4.2.3 1:2:4 (1 Cement : 2 coarse sand derived from natural sources: 4
graded stone aggregate 20 mm nominal size derived from natural
sources)
cum
4.2.3A 1:2:4 (1 Cement : 2 inlcuding manuvactured sand derived from
Recycled Concrete Aggregate (RCA) upto 25%: 4 graded stone
aggregate 20 mm nominal size Recycled Concrete Aggregate
(RCA) upto 25%)
cum
4.2.5 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6
graded stone aggregate 20 mm nominal size derived from natural cum
sources)
cum
4.2.5B 1:3:6 (1 cement : 3 manufactured sand derived from Recycled
Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm
nominal size derived from Recycled Aggregate (RA))
cum
4.2.8 1:5:10 (1 cement : 5 coarse sand derived from natural sources:
10 graded stone aggregate 40 mm nominal size derived from
natural sources)
cum
4.2.8A 1:5:10 (1 cement : 5 manufactured sand derived from Recycled
Concrete Aggregate (RCA) : 10 graded stone aggregate 40
mm nominal size derived from Recycled Aggregate (RA))
cum
4.4 P/L cement concrete in kerbs, steps etc.:
4.4.1 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate 20 mm
nominal size derived from natural sources) cum 4.00
4.4.1A 1:1.5:3 (1 cement : 1.5 inlcuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled Concrete
Aggregate (RCA) upto 25% cum 4.00
4.00
3.20
3.20
2.20
2.20
2.20
1.30
1.30
ggregate 20 mm
cum
4.5.1A 1:1½:3 (1 cement:1½ inlcuding manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 25% : 3 graded stone
aggregate 20 mm nominal size derived from Recycled Concrete Aggregate
(RCA) upto 25%)
cum
4.6 P/L precast cement concrete in kerbs, edgings etc.:
4.6.1 1:1.5:3 ( 1 cement : 1.5 coarse sand derived from natural sources :
3 graded stone aggregate 20 mm nominal size derived from natural sources) cum
cum
4.7 P/L precast cement concrete solid blocks:
4.7.1 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
cum
4.7.1A 1:1.5:3 (1 cement : 1.5 inlcuding manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 25% : 3 graded stone
aggregate 20 mm nominal size derived from Recycled Concrete Aggregate
(RCA) upto 25% )
cum
4.8 P/L precast cement concrete hollow blocks:
4.8.1 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources :
3 graded stone aggregate 20 mm nominal size derived from natural sources ) cum
cum
4.05
4.05
4.05
4.05
4.56
4.56
2.899
2.899
4.9 Precasting and placing in position 125 mm dia Bollards 600
mm high…. . cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III)
derived from natural sources : 6 graded stone aggregate 20 mm nominal
size derived from natural sources)…..
each
4.9A Precasting and placing in position 125 mm dia Bollards 600 mm high…. .
cement concrete 1:3:6 (1 Cement : 3 manufactured sand derived from
Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA))…..
each
4.9B Precasting and placing in position 125 mm dia Bollards 600 mm high…. .
cement concrete 1:3:6 (1 Cement : 3 manufactured sand derived from
Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20 mm
nominal size derived from Recycled Aggregate (RA))…..
each
DAMP- PROOF COURSE
4.10 P/L D.P.C. 40 mm thick with C.C. (1 cement :2 coarse sand derived from
natural sources :4 graded stone aggregate 12.5mm nominal size derived
from natural sources).
sqm
4.10A P/L D.P.C. 40 mm thick with C.C. (1 cement :2 inlcuding manufactured
sand derived from Recycled Concrete Aggregate (RCA) upto 25% :4
graded stone aggregate 12.5mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 25%).
sqm
4.11 P/L D.P.C. 50 mm thick with C.C. (1 cement :2 coarse sand derived from
natural sources :4 graded stone aggregate 12.5mm nominal size derived
from natural sources).
sqm
4.11A P/L D.P.C. 50 mm thick with C.C. (1 cement :2 inlcuding manufactured
sand derived from Recycled Concrete Aggregate (RCA) upto 25% :4
graded stone aggregate 12.5mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 25%).
sqm
MISCELLANEOUS
4.17 Making plinth protection 50 mm thick of cement concrete 1:3 coarse sand
(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm
nominal size derived from natural sources)
sqm
4.17A Making plinth protection 50 mm thick of cement concrete 1:3 manufactured
sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone
aggregate 20 mm nominal size derived from Recycled Concrete Aggregate
(RCA))
sqm
0.097
0.097
0.097
0.13
0.13
0.16
0.16
0.11
0.11
4.17B Making plinth protection 50 mm thick of cement concrete
1:3 manufactured sand derived from Recycled Concrete Aggregate
(RCA) : 6 graded stone aggregate 20 mm nominal size derived from
Recycled Aggregate (RA))
sqm
4.19 DELETED
0.11
4.19.1 DELETED
4.19.1.1 DELETED
4.19.1.2 DELETED
4.19.2 DELETED
4.19.2.1 DELETED
4.19.2.2 DELETED
4.20 P/L ready mix plain cement concrete derived from natural sources
4.20A P/L ready mix plain cement concrete derived from natural
sources & Recycled Concrete Aggregate (RCA) 4.20A.1 All works upto plinth level
4.20A.1.1 Concrete of M10 grade with minimum
cement content of 220 kg /cum cum 2.20
4.20A.1.2 Concrete of M15 grade with minimum
cement content of 240 kg /cum cum 2.40
m
0.11
2.20
2.40
2.70
3.00
2.20
2.40
2.70
3.00
4.20A.1.3 Concrete of M20 grade with minimum
cement content of 270 kg /cum cum
3.00
2.20
2.40
2.70
3.00
1.0 COEFFICIENTS FOR CEMENT CONSUMPTION
5.0 REINFORCED CEMENT CONCRETE
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
CAST-IN-SITU
5.1 P/L R.C.C. upto plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources: 3
graded stone aggregate 20 mm nominal size derived from natural sources)
cum
5.1.2A 1:1.5:3 (1 cement : 1.5 coarse sand including manufactured
sand derived from Recycled Concrete Aggregate (RCA) upto 20%: 3
graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%)
cum
5.1.3 1:2:4 (1 cement : 2 coarse sand derived from natural sources: 4
graded stone aggregate 20 mm nominal size derived from natural sources)
cum
5.1.3A 1:2:4 (1 cement : 2 coarse sand including manufactured sand
derived from Recycled Concrete Aggregate (RCA) upto 20%: 4 graded
stone aggregate 20 mm nominal size derived from Recycled Concrete
Aggregate (RCA) upto 20%)
cum
5.2 R.C.C work in walls etc.:
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources: 3
graded stone aggregate 20 mm
nominal size derived from natural sources)
cum
5.2.2A 1:1.5:3 (1 cement : 1.5 coarse sand including
manufactured sand derived from Recycled Concrete Aggregate
(RCA) upto 20%: 3 graded stone aggregate 20 mm nominal
size derived from Recycled Concrete Aggregate (RCA) upto 20%)
cum
5.3 R.C.C. (1:1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in beams etc.
cum
5.3A R.C.C. (1:1.5 including manufactured sand derived from Recycled
Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%)
work in beams etc.
cum
5.4 R.C.C. (1:1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in kerbs, steps etc.
cum
Unit Quantity of cement
per unit quantity of
work (Quintals)
4.00
4.00
3.2
3.2
4.00
4.00
4.00
4.00
4.00
5.4A R.C.C. (1:1.5 including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate
20 mm nominal size derived from Recycled Concrete Aggregate (RCA) upto
20%) work in kerbs, steps etc.
cum
5.5 R.C.C. (1:1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in arches,domes etc.
cum
5.A R.C.C. (1:1.5 including manufactured sand derived from Recycled
Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%)
work in arches,domes etc.
cum
5.6 R.C.C. (1:1.5 coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in chimneys & shafts.
cum
5.6A R.C.C. (1:1.5 including manufactured sand derived from Recycled
Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%)
work in chimneys & shafts.
cum
5.7 R.C.C. (1:1.5coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in well-steining.
cum
5.7A R.C.C. (1:1.5 including manufactured sand derived from Recycled
Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%)
work in well-steining.
cum
5.8 R.C.C. (1:1.5coarse sand(zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources)
work in vertical and horizontal fins individually or forming box louvers, facias
and eaves boards.
cum
5.8A R.C.C. (1:1.5 including manufactured sand derived from Recycled
Concrete Aggregate (RCA) upto 20%: 3 graded stone aggregate 20 mm
nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%)
work in vertical and horizontal fins individually or forming box louvers, facias
and eaves boards.
cum
PRE - CAST R.C.C.
5.12 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) work in string courses, bands, copings, bed plates, anchor
blocks, plain window sills etc.
cum
5.12A P/F precast R.C.C. (1:1.5 including manufactured sand
derived from Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%) work in string courses, bands,
copings, bed plates, anchor blocks, plain window sills etc.
cum
5.13 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) in small lintels not exceeding 1.5m clear span.
cum
5.13A P/F precast R.C.C. (1:1.5 including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%) in small lintels not exceeding 1.5m
clear span.
cum
5.14 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) in mouldings as in cornices, windows sills etc.
cum
5.14A P/F precast R.C.C. (1:1.5 including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%) in mouldings as in cornices, windows
sills etc.
cum
5.15 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) in lintels, beams and bressumers etc.
cum
5.15A P/F precast R.C.C. (1:1.5 including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%) in lintels, beams and bressumers
etc.
cum
5.16 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) in shelves.
cum
5.16A P/F precast R.C.C. (1:1.5 including manufactured sand derived from
Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled
Concrete Aggregate (RCA) upto 20%) in shelves.
cum
5.17 P/F precast R.C.C. (1:1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from
natural sources) in vertical & horizontal fins individually or forming box
louvers.
cum
5.17A P/F precast R.C.C. (1:1.5 including manufactured sand
derived from Recycled Concrete Aggregate (RCA) upto 20%
: 3 graded stone aggregate 20 mm nominal size derived from Recycled Concrete Aggregate (RCA) upto 20%) in vertical &
horizontal fins individually or forming box louvers. cum 4.00
5.18 Fixing precast cement concrete Jali (1:2:4).
5.18.1 50 mm thick 100 sqm 1.64*
5.18.2 40 mm thick 100 sqm 1.64*
5.18.3 25 mm thick 100 sqm 1.64*
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.05
4.05
4.00
CA) upto 20%) in vertical &
0
1.0 COEFFICIENTS FOR CEMENT CONSUMPTION
6.0 MASONRY WORK
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
6.1 Brick work in foundation & plinth with non modular bricks.
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum
6.20 & Tile brick masonry with tile bricks in plain/gauged arches
6.21 work in in cement mortar (1:4). cum
6.22 Tile brick masonry work 5 cm thick in cement mortar (1:3). 100 sqm
Unit Quantity of cement
per unit quantity of
work (Quintals)
0.95
0.625
0.836
0.55
0.625
0.55
0.95
0.625
3.86
9.23
1.28
14.28
10.64
1.52
1.00
1.00
1.33
7.65
Code Description Unit
No.
6.27 Brick work with modular bricks in cement mortar (1:6). cum
6.28 Brick work with machine moulded modular bricks in cement mortar (1:6).
cum
6.29 Brick work with m/c moulded F.P.S. bricks in cement mortar (1:6).
cum
6.30 Brick work with machine moulded perforated F.P.S. bricks in cement
mortar (1:6). cum
6.31 Brick work with machine moulded perforated modular bricks in cement
mortar (1:6). cum
6.38 Autoclaved aerated cement blocks masonry with 100mm thick AAC
blocks in cement mortar (1:4). cum
6.56
0.625
0.55
0.55
0.625
0.625
0.55
0.95
0.625
0.95
0.625
0.836
0.55
0.836
1.275
0.57
0.137
14.28
10.64
RANDOM RUBBLE MASONRY
7.1 & 7.2 Random rubble masonry with cement mortar (1:6). cum
COURSED RUBBLE MASONRY
7.6 Coursed rubble masonry (first sort) with :
7.6.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum
7.7 Coursed rubble masonry (second sort) with :
7.7.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum
ASHLAR MASONRY
7.12 Stone work in plain ashlar in cement mortar (1:6) including pointing with
white cement mortar (1:2). cum
7.13 & 7.14 Stone work plain ashlar in arches/domes in cement mortar (1:3) including
pointing with white cement mortar (1:2). cum
7.15 Stone work ashlar punched in cement mortar 1:6) including pointing with
white cement mortar (1:2). cum
100 sqm
7.29 P/F horizontal chajja of stone 40 mm thick and upto 80 cm projection in
cement mortar (1:4) i/c pointing in white cement mortar (1:2).
100 sqm
7.30 P/F 30 mm red sand stone sun-shade with cement mortar 1:4 including
finishing complete. 100 sqm
7.31 Providing and fixing red sand stone brackets 55x22.5x45cm. 100nos
7.32 Stone work, plain in copings, cornices, string courses etc. in Cement
mortar 1:6 including pointing with white cement mortar (1:2).
cum
7.38 Stone tile work for wall lining with 12 mm thick bed in cement mortar
(1:3). sqm
* White cement
8.1 Marble work 18 mm thick for wall lining in cement mortar 1:3
including pointing with white cement mortar 1:2. 100 sqm
8.2 P/F 18mm thick gang saw cut mirror polished premoulded and
prepolished) machine cut for kitchen platforms, vanity counters etc. laid
over 20mm thick base cement mortar 1:4.
100 sqm
8.4 Extra for fixing marble /granite stone over and above corresponding
basic item, in facia and drops of width upto 150 mm with epoxy resin
based adhesive including cleaning etc. complete.
100 metre
8.7 P/F cramps in RCC/ CC backing with cement mortar 1:2 .
8.7.1 Gunmetal cramps kg
8.7.2 Stainless steel cramps kg
8.9 Stone tile work for wall lining over 12mm thick bed of cement mortar (1:3)
and cement slurry @ 3.3 kg/sqm including pointing in white cement
complete.
100 sqm
8.11 P/F machine cut mirror/edge polished 100 sqm.
8.14 Stone work (machine cut edges) for wall lining etc. (veneer work) in
cement mortar (1:3) including pointing in white cement mortar (1:2).
100 sqm
8.15 P/F stainless steel cramps in stone wall lining in cement mortar (1:2).
kg
8.16 P/F copper pins 7.5 cm long 6 mm diameter in stone wall lining in cement
mortar (1:2). each
8.17 Wall lining butch work with Dholpur stone 40 mm thick, in cement mortar
(1:3) including ruled pointing in cement mortar (1:2).
100 sqm
8.18 Stone work ( machine cut edges) for wall lining with grout of 12 mm thick
in cement mortar (1:3) and jointed with Cement mortar (1:2).
100 sqm
8.21 P/F structural steel frame (for dry stone cladding) embedded in brick wall
with cement concrete block (1:2:4) 100kg
8.23 P/F 50x50x50 mm 2nd class teak wood plugs in cement mortar 1:3.
100 nos.
8.25 P/F 2nd class teak wood plain lining with wooden plugs. 100 sqm
8.31 P/F 1st quality ceramic glazed wall tiles over 12 mm thick bed of cement
Mortar (1:3) with grey cement slurry @ 3.3kg/ sqm
sqm
* White cement
0.825
0.750
0.750
0.54
1.07
0.54
0.54
0.007
5.59
4.94 + 0.03*
2.19
3.02
0.54
10.44 + 1.70*
8.67 + 1.70*
9.12
1.27
0.0635
0.0701
10.44 + 1.90*
8.16 + 3.30*
9.18 + 1.56*
0.07
0.007
15.50 +1.70*
13.744
1.05
0.01
0.055
0.1044
MISCELLANEOUS - WOOD WORK
9.46 P/F curtain rods of 1.25 mm thick chromium plated brass brackets with
wooden plugs, etc. 100 metre
9.47 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated
brackets. 100 metre
9.53 Providing 40x5 mm flat iron hold fast 40 cm long with cement concrete
block 30x10x15cm 1:3:6 mix. 100 nos 1.10 100 nos
0.01
0.01
1.10
10.4 P/F 1 mm thick M.S. sheet sliding-shutters with frame. 100 sqm
10.5 P/F 1 mm thick M.S. sheet door with frame. 100 sqm
10.6 Supplying and fixing rolling shutters. 100 sqm
10.10.1 & Fixing standard steel glaze door windows etc. 100 kg
10.11.1
10.13.1 P/F ‘T’ iron froms for doors windows & ventilators 100 kg
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators
and cupboard with 15x3 mm lugs 10 cm long embedded in cement
concrete blocks 15x10x10 cm of 1:3:6 mix.
100 kg
0.35
0.35
0.35
0.13
0.11
0.28
11.1 Brick on edge flooring.
11.1.1 1:4 (1 cement : 4 coarse sand) sqm
0.1285
17
0.231
0.263
0.14
3.20
0.1695
0.129+0.0405*
0.1492+0.0202*
0.129+0.0202*
0.1695
0.1695
0.1783
0.1205+0.0578*
0.1494+0.0289*
0.1205+0.0578*
0.1783
0.1783
0.1907
0.1097+0.081*
0.1502+0.0405*
11.11.4 White cement without any pigment sqm 0.1097+0.081*
11.11.5 Light shade pigment with ordinary cement sqm 0.1097
11.11.6 Ordinary cement without any pigment sqm 0.1097
11.12 Marble chips skirting :
11.12.1 18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement : 3 coarse sand)
sqm
11.12.1.4 White cement without any pigment sqm
11.12.1.5 Light shade pigment with ordinary cement
sqm
* White Cement
TILE FLOORING
11.16 Precast terrazo tiles 22mm thick in floors, and landings on 20mm thick bed of
cement mortar (1:4).
11.16.1 Light shade using white cement sqm
11.16.2 Medium shade using 50%white cement and 50% ordinary cement
sqm
e sand)
0.1292
0.0887+0.0405*
0.109+0.0203*
0.109+0.0405*
0.1292
0.1292
0.1200+0.0405*
0.0895+0.044*
0.0917+0.0220*
0.0939
0.0939
0.0734+0.066*
0.1064+0.033*
0.1394
0.1394
0.0895+0.044*
11.19.2 Medium shade using 50% white cement, 50%
ordinary cement sqm
11.19.3 Dark shade using ordinary cement sqm
11.19.4 Ordinary cement without any pigment sqm
11.20 Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4).
STONE FLOORING
11.23 Marble stone flooring with 18 mm thick marble stone over 20 mm thick
cement mortar (1:4). sqm
11.27 Kota stone slabs 20 mm thick in risers of steps, skirting etc. laid on 12 mm
(average) thick cement mortar 1:3. sqm
11.29 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of
cement mortar 1:5 including pointing with cement mortar 1:2.
sqm
11.30 40 mm thick rubbed stone flooring over 20 mm (average) thick base of
cement mortar 1:5 with joints 3mm thick, side buttered with cement mortar
1:2.
sqm
0.0917+0.024*
0.0939
0.0939
bed of cement mortar (1:4).
0.1291+0.066*
0.1621+0.033*
0.1951
0.1951
0.1044
0.13512
0.1491
0.1374
0.0775
0.0931
0.0931
CERAMIC GLAZED TILES
11.37 P/L ceramic glazed floor tiles laid on 20 mm thick Cement Mortar (1:4)
with grey cement @ 3.3kg/sqm sqm
11.38 P/L ceramic glazed floor tiles laid on 20mm thick bed of Cement Mortar
(1:4) with grey cement @ 3.3kg/sqm sqm
11.39 & P/L rectified Glazed Ceramic floor tiles laid on 20mm thick cement mortar
11.40 (1:4). sqm
0.1242
0.1242
0.1242
0.0646
0.088
0.085 + 0.05*
0.085 + 0.05*
13.50
13.50
12.16 10 cm thick mud phaska with flat tile bricks grouted with
cement mortar (1:3). 100 sqm
12.17 10cm thick mud phaska with machine moulded tile bricks grouted with
cement mortar (1:3). 100 sqm
12.19 Providing and laying brick tiles over mumty roofs grouted with cement
mortar (1:3). 100 sqm
12.20 Providing and laying pressed clay tiles on roofs jointed with cement
mortar (1:4). 100 sqm
12.23 Providing sand stone slab for roofing and laying cement mortar (1 : 4).
100 sqm
12.38 Providing and fixing M.S. holder bat clamps in cement concrete blocks
10x10x10cm of 1:2:4 mix. each
12.55 P/F heat resistant tile on roof with cement mortar (1:4) and filling joints
with white cement marble mix. sqm
3.11
3.11
9.13
9.92
0.031
0.06
0.74
0.005
0.1367
CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster:
13.1.1 1:4 (1 cement : 4 fine sand) 100 sqm
13.1.2 1:6 (1 cement : 6 fine sand) 100 sqm
13.2 15 mm cement plaster:
13.2.1 1:4 (1 cement : 4 fine sand) 100 sqm
13.2.2 1:6 (1 cement : 6 fine sand) 100 sqm
13.3 20 mm cement plaster :
13.3.1 1:4 (1 cement : 4 fine sand) 100 sqm
13.3.2 1:6 (1 cement : 6 fine sand) 100 sqm
CEMENT PLASTER (IN COARSE SAND)
13.4 12 mm cement plaster :
13.4.1 1:4 (1 cement : 4 coarse sand) 100 sqm
13.4.2 1:6 (1 cement : 6 coarse sand) 100 sqm
13.5 15 mm cement plaster :
13.5.1 1:4 (1 cement : 4 coarse sand) 100 sqm
13.5.2 1:6 (1 cement : 6 coarse sand) 100 sqm
13.6 20 mm cement plaster :
13.6.1 1:4 (1 cement : 4 coarse sand) 100 sqm
13.6.2 1:6 (1 cement : 6 coarse sand) 100 sqm
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT
6.54
4.30
8.51
5.60
5.47
3.60
6.54
4.30
8.51
5.60
9.54
7.67
10.97
8.74
9.54
13.62
13.10 15 mm cement plaster (1:3) finished with a floating coat
of neat cement. 100 sqm
100 sqm
13.12 18 mm cement plaster in two coats under layer 12 mm thick cement
plaster 1:5 and a top layer 6mm thick cement plaster (1:3).
100 sqm
13.13 12 mm cement plaster 1:2 (1 cement : 2 stone dust). 100 sqm
13.14 15 mm cement plaster 1:2 (1 cement : 2 stone dust). 100 sqm
13.15 20 mm cement plaster 1:2 (1 cement : 2 stone dust). 100 sqm
6 MM CEMENT PLASTER
13.16 6 mm cement plaster of mix :
13.16.1 1:3 (1 cement : 3 fine sand) 100 sqm
13.17 6 mm cement plaster (1:3) finished with a floating coat of neat cement.
100 sqm
100 sqm
PLAIN CEMENT MORTAR BANDS
13.28 12 mm thick plain cement mortar bands in cement mortar (1:4) : 100 metre 1cm
(Flush /Sunk / Raised / Moulded Band). wide
13.29 18 mm thick plain cement mortar band in cement mortar (1:4) 100 metre 1cm
wide
13.30 18 mm thick moulded cement mortar band in two coats under layer
12mm thick with cement mortar 1:5, top layer 100 metre
13.35 Pointing on stone slab ceiling with cement mortar (1:2). 100 sqm
13.72 Washed stone grit plaster on exterior walls in two layers under layer
12mm cement plaster (1:4), top layer 15mm cement plaster 1:1/2:2.
100 sqm
Note: - cement consumption for pointing is same for modular & non
modular bricks.
* White cement
10.97
6.26
8.13
9.79
11.70
15.23
3.67
5.87
2.20
11.59
11.59
0.053
0.076
0.07
1.53
2.04
2.35
1.17
2.35
2.35*
1.02
17.472
14.0 REPAIRS TO BUILDING
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
14.2 Fixing chowkhats in existing opening with hold fasts in cement concrete
blocks with cement concrete 1:3:6.
14.2.1 Door chowkhats each
14.2.2 Window chowkhats each
14.2.3 Clerestory window chowkhats each
14.12 Providing and fixing 16 mm M.S. Fan clamps in existing
R.C.C. slab. each
14.16 Renewing wooden beams in roofs & making good the holes in walls.
cum
14.18 Flush pointing with cement mortar 1:3 for flat tile bricks on top of mud
phaska. 100 sqm
Unit Quantity of cement
per unit quantity of
work (Quintals)
6.95
0.12
0.06
0.03
0.016
3.11
0.78
0.36
0.13
0.76
16.0 ROAD WORK
Code Description Unit Quantity of cement
No.
FENCING
16.23 P/F boundary stone including finishing smooth with cement mortar (1:3).
each
16.24 P/F precast R.C.C. kilometre stone including finishing smooth in cement
mortar (1:3).
16.24.1 35x111x25 cm size each
16.24.2 50x152.5x25 cm size each
16.24.3 35x93.5x18 cm size each
CONCRETE PAVEMENT
16.42 Cement concrete (1:2:4) in pavements. cum
16.43 Providing and laying design mix cement concrete of M-30 grade, in
roads/ taxi tracks/ runways, using cement content as per design mix.
cum
MISCELLANEOUS
16.49 Making bell mouth opening including providing cement concrete (1:3:6) &
plastering with cement mortar (1:3). 10 Nos.
16.52 Providing and fixing precast lime fly ash concrete blocks including
finishing with 10mm thick cement mortar (1:3), in foot paths.
sqm
16.63 16.63 P/L kerb channel 30cm wide and 50mm thick of cement concrete
(1:3:6). metre
16.67 Providing and fixing factory made RCC pavement slab of M-30 grade in
footpath over a bed of 20mm average thick cement mortar (1:5).
100 sqm
16.69 Providing and laying factory made kerb stone of M-25 grade jointed with
cement mortar (1:3). cum
16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete. cum
0.082
0.37
0.698
0.23
3.20
3.40
6.60
0.05
0.11
7.75
0.05
3.30
1.50
0.3723
0.09
0.09
0.12
0.12
0.12
1.85
0.352
17.0 SANITARY INSTALLATIONS
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
17.4.2 Range of two urinal basins with 5 litre white P.V.C. automatic
flushing cistern each
17.4.3 Range of three urinal basins with 10litre white P.V.C. automatic
flushing cistern each
17.4.4 Range of four urinal basins with 10 litre white P.V.C. automatic
flushing cistern each
17.5 Fixing white vitreous china flat back half stall urinal :
17.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing
cistern each
17.5.2 Range of two half stall urinals with 5 litre P.V.C. automatic
flushing cistern each
17.5.3 Range of three half stall urinals with 10 litre P.V.C. automatic
flushing cistern each
17.5.4 Range of four half stall urinals with 10 litre P.V.C. automatic
flushing cistern each
0.05
0.025
0.04
0.067
0.095
0.051
0.102
0.153
0.203
0.051
0.102
0.153
0.203
0.025
0.016*
0.025
0.025
0.025
0.014
Code Description Unit
No.
17.13 Fixing White vitreous china water closet squatting pan. each
0.025
0.025
0.01
0.02
0.015
0.015
0.015
0.005
0.005
0.025
5.40
3.70
1.87
1.0 COEFFICIENTS FOR CEMENT CONSUMPTION
18.0 WATER SUPPLY
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
18.76 Cutting holes up to 30x30 cm in walls including making good the same.
100 Nos.
18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs and repairing
the hole after insertion of drain pipes etc. with cement concrete (1:2:4).
100 Nos.
18.78 Making chases up to 7.5x7.5 cm in walls i/c finishing. 100 metre
18.79 Making hole up to 20x20 cm and embedding pipes up to 150 mm
diameter in masonry and filling with cement concrete (1:3:6).
100 metre
Unit Quantity of cement
per unit quantity of
work (Quintals)
0.05
0.06
0.07
0.075
0.08
0.08
0.88
0.26
1.44
2.48
3.50
1.30
1.34
2.92
0.70
0.88
4.90
1.0 COEFFICIENTS FOR CEMENT CONSUMPTION
19.0 DRAINAGE
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
19.1 Jointing glazed stoneware pipes with stiff mixture of cement mortar in the proportion of (1:1).
n of (1:1).
2.17
3.23
4.33
5.40
6.47
19.24
23.53
27.43
31.72
9.14
14.82
17.42
20.28
23.40
27
6
25
n the proportion of (1:2):
0.50
0.60
0.90
1.10
2.40
2.60
3.20
3.70
19.6.9 800 mm dia. R.C.C. pipe 100 metre
19.6.10 900 mm dia. R.C.C. pipe 100 metre
19.6.11 1000 mm dia. R.C.C. pipe 100 metre
19.6.12 1100 mm dia. R.C.C. pipe 100 metre
19.6.13 1200 mm dia. R.C.C. pipe 100 metre
19.7 Constructing brick masonry manhole in cement mortar (1:4).
19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom
and 0.56m dia at top in cement mortar (1:4).
19.13 Constructing brick masonry circular manhole 1.52 m internal dia at bottom
and 0.56 m dia at top in cement mortar (1:4).
19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm
cement concrete blocks (1:3:6). 100 nos.
2.92
4.73
1.26
1.52
2.75
1.40
5.39
1.43
10.86
3.11
0.88
1.98
0.88
19.19 Providing and fixing in position precast R.C.C. manhole cover and frame.
19.23.1 For 100 mm dia. sand cast iron drop connection metre
19.23.2 For 150 mm dia. sand cast iron drop connection metre
19.27 Constructing brick masonry road gully chamber 50x45x 60cm in cement
mortar (1:4). each
0.096
0.096
0.128
0.096
0.096
0.096
he walls, floors with C.C.
0.056
0.095
0.153
0.34
0.46
0.21
0.26
0.93
0.82
1.66
0.90
19.30.2 Inside dimensions 500x700 mm and 45 cm deep
for pipe line with one or two inlets each 1.02
19.30.3 Inside dimensions 600x 850 mm and 45 cm deep
19.34 Providing and fixing S.W. intercepting trap in manholes with stiff mixture of
cement mortar (1:1).
19.34.1 100 mm dia each
19.34.2 150 mm dia each
19.35 P/L Non pressure Np-3 class
19.35.1 450 mm dia RCC pipe 100 metre
19.35.2 600 mm dia RCC pipe 100 metre
19.35.3 900 mm dia RCC pipe 100 metre
19.35.4 1000 mm dia RCC pipe 100 metre
19.35.5 1200 mm dia RCC pipe 100 metre
19.35.6 1800 mm dia RCC pipe 100 metre
19.36 P/L Non pressure Np-4 class 100 metre
19.36.1 450 mm dia RCC pipe 100 metre
19.36.2 600 mm dia RCC pipe 100 metre
19.36.3 900 mm dia RCC pipe 100 metre
19.36.4 1000 mm dia RCC pipe 100 metre
19.36.5 1200 mm dia RCC pipe 100 metre
19.36.6 1800 mm dia RCC pipe 100 metre
.02
1.27
0.87
0.95
1.12
0.072
0.013
0.019
1.20
1.60
2.50
2.80
3.40
4.90
1.20
1.60
2.50
2.80
3.40
4.90
1.0 COEFFICIENTS FOR CEMENT CONSUMPTION
20.0 PILE WORK
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
20.1 Providing, driving and installing driven cast-in-situ reinforced cement concrete piles of grade M -25.
of grade M -25.
0.414
0.525
0.648
0.784
1.456
2.590
3.729
5.83
s of grade M -25 by tripod
0.525
0.648
0.932
1.456
0.932
1.456
2.590
3.729
5.830
M -25.
0.257
0.488
0.629
0.792
0.109
Code Description Unit Quantity of cement
No. per unit quantity of
work (Quintals)
20.4.2 400 mm dia piles metre 0.208
0.267
0.396
0.414
0.525
0.648
0.784
1.795
2.590
22.0 WATER PROOFING
Code Description Unit
No.
0.342
0.443
0.158
0.0123
0.0195
0.387
3.20
5.10
3.80
26.0 NEW TECHNOLOGIES AND MATERIALS
Code Description Unit
No.
26.31.1 SBR Polymer (@10% of cement weight) modified cementitious bond coat
@2.2 kg cement per sqm.
100 sqm
26.32 Providing, mixing and applying SBR polymer (of approved make)
modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse
sand with polymer minimum 2% by wt. of cement used) .
26.33.2 75mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
26.34 Providing and laying SBR Polymer modified (of approved make @
minimum 2% by wt. of cement used) plain/reinforced concrete jacket
for the structural members e.g. columns, pillars, piers, beams etc with
concrete.
26.34.1 50mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
26.34.2 75mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
26.34.3 100mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
100 kg
26.35.2 Stirrer mixed SBR Polymer (of approved make)
modified Cement slurry made with Shrinkage Compensating
Cement in concrete/RCC work. 100 kg
Quantity of cement
per unit quantity of
work (Quintals)
2.2
5.47
11.40
22.80
16.50
24.75
16.5
24.75
33.00
1.00
1.00
26.38 Shotcreting R.C.C. columns, beams and slabs etc. in layers
with approved design mix concrete having.
26.38.1 25mm thick in Grade M 25 with cement content
not less than 330 kg per cum 100 sqm
26.38.2 50mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
26.38.3 75mm thick in Grade M 25 with cement content not less than
330 kg per cum 100 sqm
26.46 Providing and fixing in position, 200 mm thick factory made Expanded
olystyrene Core (EPS Core) wall panels consisting of EPS core
sandwiched between two Engineered sheets of welded wire fabric mesh.
applying the layer of
50 mm thick cement mortar 1:3 (1 cement: 3 coarse sand)
100 sqm
26.47 Providing and fixing in position, 230mm thick factory made Expanded
Polystyrene Core (EPS Core) roof/floor panels. applying a layer
of 60-65 mm thick cement
mortar 1: 3 {1 cement: 3 coarse sand. applying 70-
75 mm thick layer of cement concrete 1:1.5: 3 (1 cement
:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
100 sqm
26.53 Filling of empty cavities with quarry dust mixed with cement cum
26.58 Filling of joints between RCC plinth beam/floor slab and wall panel of
external walls 100 metre
26.59 Waterproofing treatment of vertical joints between door frame, window &
ventilator frames 100 metre
26.61 In filling/ sealing of joint between RCC lintel cum sunsdhade and wall
100 metre
26.66 P/F factory made EPS wall panels consisting EPS core sandwhiched
between two Enginered sheets sqm
26.68 P/F Factory made Precast Concrete solid blocks in foundation and plinth
sqm
26.69 P/F Factory made Precast Concrete solid blocks in superstructure above
plinth level up to floor V level cum
26.70 Providing and laying half block masonry with factory made Precast
concrete solid blocks in foundation and plinth 100 sqm
26.71 Providing and laying half block masonry with factory made Precast
concrete solid blocks insuperstructure above plinth level up to floor V
level
100 sqm
26.73.1 Fabrication & Manufacturing of prestressed Hollow Core slab of concrete
grade M-40 (cement conetent 400kg)
26.73.1.1 100 mm thick hollow core slab metre
10.31
20.63
30.94
51.00
58.60
0.72
0.03125
0.03125
0.03125
0.357
0.2825
0.2825
2.6904
2.6904
0.36
26.73.1.2 120 mm thick hollow core slab metre 0.432
26.73.1.3 150 mm thick hollow core slab metre 0.54
26.73.1.4 200 mm thick hollow core slab metre 0.672
26.73.1.5 250 mm thick hollow core slab metre 0.84
26.73.1.6 300 mm thick hollow core slab metre 1.008
26.73.1.7 350 mm thick hollow core slab metre 1.176
26.73.1.8 400mm thick hollow core slab metre 1.344
26.73.2 Extra for using M-50 (Cement content 425kg) instead of M-40
26.74.1 Concrete grade M-35 (Cement content 370 kgs) cum 3.70
26.74.2 Extra for using M-40 (Cement content 400 kg) instaed of M-
35 cum 0.30
26.74.3 Extra for using M-50 (Cement content 425 kg) instaed of M-
35 cum 0.55
26.74.4 Extra for using M-60 (Cement content 440 kg) instaed of M-
35 cum 0.70
26.82 Providing and laying rigid EPS (cellular plastic material) blocks 100 sqm 8.38
COEFFICIENTS FOR
BITUMEN CONSUMPTION
0.432
0.54
0.672
0.84
1.008
1.176
1.344
0.0225
0.027
0.03375
0.042
0.0525
0.063
0.0735
0.084
0.036
0.0432
0.054
0.0672
0.084
0.1008
0.1176
0.1344
.,
3.70
0.30
0.55
0.70
8.38
2.0 COEFFICIENTS FOR BITUMEN CONSUMPTION
16.0 ROAD WORK
Code Description Unit
No.
SURFACE DRESSING
16.25 Surface dressing on new surface with paving bitumen of grade VG -10.
sqm
16.26 Surface dressing on new surface in two coats with bitumen of grade VG -10.
sqm
16.27 Surface dressing on old surface with hot bitumen of grade VG -10.
sqm
16.33 2.5 cm premix carpet surfacing with paving asphalt VG-10/ VG-30/modified
bitumen CRMB 55. sqm
Quantity of bitumen
per unit quantity of
work (Quintals)
0.0225
0.029
0.0195
0.0195
0.0122
0.0075
0.0050
0.0040
0.0025
0.0144
0.018
0.0255*
0.0313*
0.050
68
0.0588
0.0941
16.38 2.5 cm thick bitumastic sheet with hot bitumen, paving asphalt
VG-10/VG-30/modified bitumen CRMB 55. sqm
16.39 4 cm thick bitumastic sheet with hot bitumen, paving asphalt VG-10/VG-
30/modified bitumen CRMB 55. sqm
SEAL COAT
16.40 P/L seal coat using 128 kg of bitumen of grade VG-10. sqm
16.41 P/L seal coat using 98 kg of bitumen of grade VG-10. sqm
16.54 P/L Dense Bituminous macadam :
16.54.1 50 to 100 mm average compacted thickness with bitumen of grade
VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2%
(percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of
100-120 TPH capacity.
cum
16.54.2 50 to 100 mm average compacted thickness with bitumen of grade
VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2%
(percentage by weight of Aggregate) prepared in Drum Type Hot Mix Plant of
60-90 TPH capacity.
cum
16.55 Providing and laying Bituminous Macadam.
cum
16.55.2 50 to 100 mm average compacted thickness with
bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Drum Type Hot Mix
Plant of 60-90 TPH capacity. cum 0.7683
100 sqm
16.56.2 25 mm compacted thickness with bitumen of grade VG-30 @
5% (percentage by weight of total mix) and lime filler @ 2%
(percentage by weight of Aggregate) prepared in Drum Type Hot Mix
Plant
of 60-90 TPH capacity.
100 sqm
0.0303
0.0479
0.0077
0.0098
1.1538
1.1538
0.7683
2.8846
2.8846
16.57 P/L Bituminous Concrete :
16.57.1 40/50 mm compacted thickness with bitumen of
grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3%
(percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant
cum
16.57.3 40/50 mm compacted thickness with bitumen of grade PMB-40 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH
capacity.
cum
16.57.4 40/50 mm compacted thickness with bitumen of grade CRMB-60 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH
capacity.
cum
16.57.5 40/50 mm compacted thickness with bitumen of grade VG-30 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
16.57.6 40/50 mm compacted thickness with bitumen of grade VG-30 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) and waste plastic additive @ 8% (percentage by
weight of bitumen) prepared in drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
16.57.7 40/50 mm compacted thickness with bitumen of grade PMB-40 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
16.57.8 40/50 mm compacted thickness with bitumen of grade CRMB-60 @
5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by
weight of Aggregate) prepared in Drum Type Hot Mix Plant of 60-90 TPH
capacity.
cum
* Including tack coat
2.0 COEFFICIENTS FOR BITUMEN CONSUMPTION
22.0 WATER PROOFING
1.2958
1.2958
1.2958
1.2958
1.2958
1.2958
1.2958
1.2958
Code Description Unit
No.
SURFACE DRESSING
22.6 P/L water proofing treatment on roofs with cement slurry & fibre glass
cloth. sqm 0.0097
22.8 P/L four courses water proofing treatment with bitumen felt over roofs:
sqm
22.10 & P/L six courses water proofing treatment with bitumen felt over roofs
22.11 applied hot @ 1.45, 120 & 1.70 for 1st, 3rd and 5th course.
sqm
22.15 P/L in situ seven course water proofing treatment with APP (1.5 mm thick
@ 2.25 kg./sqm). sqm
22.16 P/L in situ five course water proofing treatment with APP (2.00 mm thick
@ 3.00 kg./sqm). sqm
22.17 P/L in situ seven course water proofing treatment with APP (2.00 mm
thick @ 3.00 kg./sqm). sqm
0.0170
0.0290
0.041
0.0435
0.036
0.024
0.0360
0.0035
0.0035
0.0035