6 5 4 3 2 1
GENERAL NOTES :
A ALL DIMENSION ARE IN mm. UNLESS SPECIFIED.
B NOISE LEVEL:- 75 dB(A) @ 1 m, 75% Load.
[FREE FIELD CONDITION]
C SOUND INSULATION:- 50 mm FOAM, DENSITY-50 kg/m3.
FRESH & HOT AIR SIDE LOUVERS:-50 mm FOAM, DENSITY-140 kg/m3.
D MATERIAL OF ACOUSTIC ENCLOSURE:- 1.6 mm THK CRCA.
E
D MATERIAL OF FUEL TANK:- 2 mm THK CRCA. D
F COLOR OF BASE FRAME =RAL 9005[JET BLACK][MIN.=60 micron]
COLOR OF ACOUSTIC ENCLOSURE =RAL 9003[SIGNAL WHITE]
E [MIN.=60 micron]
F COLOR OF FUEL TANK =RAL 9005[JET BLACK][MIN.=60 micron]
G REFER ENGINE , ALTERNATOR AND SGPL DG SET
TECHNICAL DATA SHEET FOR DETAIL SPECIFICATION.
C C
TOP VIEW
DYNAMIC WEIGHT OF DG SET [APPROX] ----- kg
STATIC WEIGHT OF DG SET [APPROX] ----- kg
13 UREA TANK BAUDOUIN 02 NOS.
12 ATS BAUDOUIN 02 NOS.
11 BATTERY SGPL STD. 01 SET.
10 SILENCER PEW 01 NO.
B B
09 BELLOW BAUDOUIN. 01 NO.
08 AVM CORI RUBBER 08 NOS.
07 DG CONTROL
PANEL SGPL 01 NO.
06 FUEL TANK SGPL [990 LITERS] 01 NO.
05 ACOUSTIC 01
ENCLOSURE SG-750IV-BD-AE-00-02 NO.
04 RADIATOR BAUDOUIN 01 NO.
03 ALTERNATOR Leroy Somer 01 NO.
02 ENGINE BAUDOUIN [6M33G4D4/5] 01 NO.
01 BASE FRAME SG-650-750IV-BD-BF-00-02 01 NO.
SR.NO. DESCRIPTION MAKE / MODEL QTY. UNIT
GENERAL TOLERANCES FOR LINEAR DIMENSION AS PER IS 2102[medium]
DIMENSION TOLE. DIMENSION TOLE. DIMENSION TOLE.
0.5 to 6 ± 0.1 400 to 1000 ± 0.8 6000 to 8000 ±3
6 to 30 ± 0.2 1000 to 2000 ± 1.2 8000 to 10000 ± 3.5
A RAD. SIDE VIEW FRONT VIEW ALT. SIDE VIEW 30 to 120 ± 0.3 2000 to 4000 ±2 10000 to 12000 ± 4.5
A
120 to 400 ± 0.5 4000 to 6000 ± 2.5 12000 to 14000 ±5
PROJECT ANGULAR TOLERANCES ± 0.5°
STERLING GENERATORS
CUSTOMER GA
PVT. LTD. DESCRIPTION SGB 750 PR-IV PROJECT NO.
CONSULTANT
R0 5-3-2024 ISSUED FOR INFORMATION. KHANVEL, SILVASSA CONTRACTOR ANGLE THIRD SCALE N.T.S.
PROJECTION ANGLE
REV. DATE DESCRIPTION DSN BY CHECKED BY APPROVED BY SHEET NO. 01 OF 01
This Drawing & information or descriptive matter set out here on are the confidential property of STERLING GENERATORS PVT. LTD. & must not be disclosed, loaned, copied or used for manufacturing tendering or for any other purpose without their written permission.
6 5 4 3 2 1