0% found this document useful (0 votes)
109 views7 pages

BATT CABLES Swa LSZH Power Cable 061kv Bs6724

The document provides specifications for SWA LSZH power cables rated at 0.6/1kV, suitable for various applications including power networks and underground installations. It details the cable's construction, including conductor type, insulation, and armor, along with core identification and bending radius. Additionally, it lists various part numbers with corresponding core counts, cross-sectional areas, and dimensions.

Uploaded by

muratgul333
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views7 pages

BATT CABLES Swa LSZH Power Cable 061kv Bs6724

The document provides specifications for SWA LSZH power cables rated at 0.6/1kV, suitable for various applications including power networks and underground installations. It details the cable's construction, including conductor type, insulation, and armor, along with core identification and bending radius. Additionally, it lists various part numbers with corresponding core counts, cross-sectional areas, and dimensions.

Uploaded by

muratgul333
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

01322 441165 sales@battcables.

com
www.batt.co.uk

SWA LSZH POWER CABLE 0.6/1KV BS6724

Multi-core LSZH cables with steel wire armour (SWA) are versatile power and auxiliary control cables suitable for use in various applications, including
power networks, underground installations, and indoor or outdoor use.

They provide excellent mechanical protection against damage, thanks to heavy galvanized steel wire armour, making them ideal for use inside and outside
buildings or for direct burial in the ground.

These cables are designed for fixed wiring applications, offering reliability and durability in power networks, both indoors and outdoors, and within cable
ducting systems.

CONDUCTOR Plain Copper

STRANDING Class 2

INSULATION XLPE

BEDDING LSZH

ARMOUR AWA (single core) or SWA (multi core)

OUTERSHEATH LSZH

OUTERSHEATH COLOUR Black

RATED VOLTAGE 0.6/1kV

CORE IDENTIFICATION 1 Core - Brown


2 Core - Brown, Blue
3 Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
4Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
5 Core - Numbered Cores (Optional: Brown, Black, Grey, Blue + Green/Yellow)
6 Core+ - Numbered Cores (Optional: Numbered + Green/Yellow)

MINIMUM BENDING RADIUS 1.5sqmm to 16sqmm - 6 x overall diameter (circular cond.) 25sqmm and above - 8 x
overall diameter (shaped cond.)

OPERATING TEMPERATURE Maximum 90°C. Mininum operating -25°C

STANDARDS BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of
600/1000V and 1900/3300V, having low emission of smoke and corrosive gases
when affected by fire BSEN50267-1Common test methods for cables under fire
conditions. Tests on gases evolved during combustion of materials from cables.
Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions.
Tests on gases evolved during combustion of materials from cables. Procedures.
Determination of the amount of halogen acid gas BSEN50266-1Common test
methods for cables under fire conditions. Test for vertical flame spread of
vertically-mounted bunched wires or cables IEC60502: Power cables with extruded
insulation and their accessories for rated voltages from 1kV to 30kV
BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions
Part 1: test for vertical flame propagation for a single insulated wire or cable Section
2: procedure for 1kW pre-mixed flame BSEN61034-2:2005 Measurement of smoke
density of cables burned under defined conditions. Test procedure and requirements
Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN
60332- 3-24:2009 (Cat C) for multiple cables
APPROVALS
SPECIFICATION DATA

BATT Part No Number of cores Nominal cross sectional area of Nominal thickness of insulation Nominal diameter under armour Nominal O/D (mm) Weight
conductor (mm) (mm)

55131 2 1.5 0.6 7.1 11 245

55132 2 2.5 0.7 8.3 12.4 309

55134 2 4 0.7 9.3 13.45 367

55145 2 6 0.7 10.5 14.65 446

55147 2 10 0.7 11.8 16 575

55149 2 16 0.7 13.8 18.7 865

56428 2 25 0.9 17.2 22.9 1280

56429 2 35 0.9 19.4 26.1 1715

56430 2 50 1 19.9 26 1770

56431 2 70 1.1 23 28.75 2250

56432 2 95 1.1 26 32.95 3038

56433 2 120 1.2 29 36.25 3638

56434 2 150 1.4 31.9 39.15 4328

56435 2 185 1.6 35.7 44.7 5803

55151 3 1.5 0.6 7.5 11.45 268

55154 3 2.5 0.7 8.9 12.95 342

55155 3 4 0.7 10 14.05 416

55159 3 6 0.7 11.2 15.35 513

55160 3 10 0.7 12.7 17.55 769

55161 3 16 0.7 14.8 19.75 1025

56474 3 25 0.9 18.6 25.5 1746

56475 3 35 0.9 20.7 27.85 2137

56476 3 50 1 22.5 28.15 2338

56477 3 70 1.1 26 31.75 3083

56478 3 95 1.1 29.7 36.3 4143

56479 3 120 1.2 33 39.75 5003

56480 3 150 1.4 37.1 44.45 6413

56481 3 185 1.6 41 48.45 7710

56482 3 240 1.7 46 53.7 9605

56483 3 300 1.8 51.2 58.85 11698

55162 4 1.5 0.6 8.3 12.15 301

55175 4 2.5 0.7 9.8 13.85 389

55193 4 4 0.7 11 15.1 493

55194 4 6 0.7 12.5 17.4 698

55195 4 10 0.7 14.1 18.9 909

55196 4 16 0.7 16.4 21.35 1235

56496 4 25 0.9 20.6 27.5 2104

56497 4 35 0.9 23 29 2511

56498 4 50 1 25.8 32.55 3105

56499 4 70 1.1 30.1 38.3 4468

56500 4 95 1.1 34.1 42.25 5665

56501 4 120 1.2 38.3 47.7 7278

56502 4 150 1.4 42.6 52.25 8653

56503 4 185 1.6 47.1 57.1 10480

56504 4 240 1.7 53.3 63.4 13090

56505 4 300 1.8 58.9 69.2 15808


56506 4 400 2 67.7 78.05 20245

55163 (Numbered Cores) 2 1.5 0.6 7.1 11 245

55021 (Numbered Cores) 2 2.5 0.7 8.3 12.4 309

55102 (Numbered Cores) 3 1.5 0.6 7.5 11.45 268

55022 (Numbered Cores) 3 2.5 0.7 8.9 12.95 342

55054 (Numbered Cores) 4 1.5 0.6 8.3 12.15 301

55050 (Numbered Cores) 4 2.5 0.7 9.8 13.85 389

55158 (Numbered Cores) 5 1.5 0.6 9 13.1 350

55507 (Numbered Cores) 5 2.5 0.7 10.7 14.8 458

55509 (Numbered Cores) 5 4 0.7 12.1 16.35 578

55512 (Numbered Cores) 5 6 0.7 13.7 18.65 815

55478 (Numbered Cores) 5 10 0.7 15.5 20.28 1071

55203 (Numbered Cores) 5 16 0.7 18.5 24.35 1632

55157 (Numbered Cores) 7 1.5 0.6 9.9 14.05 402

55364 (Numbered Cores) 7 2.5 0.7 11.7 15.95 522

55510 (Numbered Cores) 7 4 0.7 13.4 18.35 761

55052 (Numbered Cores) 7 6 0.7 19.9 941

55137 (Numbered Cores) 7 10 0.7 22.2 1331

55167 (Numbered Cores) 7 16 0.7 26.9 2038

55166 (Numbered Cores) 12 1.5 0.6 13.2 18.2 674

55352 (Numbered Cores) 12 2.5 0.7 15.8 20.95 885

55511 (Numbered Cores) 12 4 0.7 18.2 24.05 1275

55451 (Numbered Cores) 19 1.5 0.6 15.6 20.6 870

55363 (Numbered Cores) 19 2.5 0.7 18.9 24.9 1343

55051 (Numbered Cores) 19 4 0.7 21.5 27.5 1708

55504 (Numbered Cores) 27 1.5 0.6 25 1229

55353 (Numbered Cores) 27 2.5 0.7 29.2 1685

55505 (Numbered Cores) 37 1.5 0.6 27.4 1493

55355 (Numbered Cores) 37 2.5 0.7 32.1 2079

55506 (Numbered Cores) 48 1.5

55264 (G/Y Core) 3 1.5 0.6 7.5 11.45 268

55170 (G/Y Core) 3 2.5 0.7 8.9 12.95 342

55179 (G/Y Core) 3 4 0.7 10 14.05 416

55171 (G/Y Core) 3 6 0.7 11.2 15.35 513

55291 (G/Y Core) 3 10 0.7 12.7 17.55 769

55372 (G/Y Core) 3 16 0.7 14.8 19.75 1025

56802 (G/Y Core) 3 25 0.9 18.6 25.5 1746

56747 (G/Y Core) 3 35 0.9 20.7 27.85 2137

55321 (G/Y Core) 4 1.5 0.6 8.3 12.15 301

55322 (G/Y Core) 4 2.5 0.7 9.8 13.85 389

55324 (G/Y Core) 4 4 0.7 11 15.1 493

55333 (G/Y Core) 4 6 0.7 12.5 17.4 698

55334 (G/Y Core) 4 10 0.7 14.1 18.9 909

55277 (G/Y Core) 4 16 0.7 16.4 21.35 1235

56755 (G/Y Core) 4 25 0.9 20.6 27.5 2104

56774 (G/Y Core) 4 35 0.9 23 29 2511

56801 (G/Y Core) 4 50 1 25.8 32.55 3105

56823 (G/Y Core) 4 70 1.1 30.1 38.3 4468

56830 (G/Y Core) 4 95 1.1 34.1 42.25 5665

56775 (G/Y Core) 4 120 1.2 38.3 47.4 7278

56027 (G/Y Core) 4 185 1.6 47.1 57.1 10480


55274 (G/Y Core) 5 1.5 0.6 9 13.1 350

55278 (G/Y Core) 5 2.5 0.7 10.7 14.8 458

55275 (G/Y Core) 5 4 0.7 12.1 16.35 578

55318 (G/Y Core) 5 6 0.7 13.7 18.65 815

55319 (G/Y Core) 5 10 0.7 15.5 20.28 1071

55339 (G/Y Core) 5 16 0.7 18.5 24.35 1632

56694 (G/Y Core) 5 25 0.9 22.7 28.6 2408

56695 (G/Y Core) 5 35 0.9 25.4 31.5 3047

56696 (G/Y Core) 5 50 1 29.9 37.2 4200

56697 (G/Y Core) 5 70 1.1 34.5 42.2 5600

56791 (G/Y Core) 5 95

56752 (G/Y Core) 5 120

56811 (G/Y Core) 5 150

56870 (G/Y Core) 5 185

56017 (G/Y Core) 5 240

55418 (Numbered + G/Y) 7 1.5 0.6 9.9 14.05 402

55419 (Numbered + G/Y) 7 2.5 0.7 11.7 15.95 522

55356 (Numbered + G/Y) 12 1.5 0.6 13.2 18.2 674

55420 (Numbered + G/Y) 12 2.5 0.7 15.8 20.95 885

55019 (Numbered + G/Y) 19 1.5 0.6 15.6 20.6 870

55020 (Numbered + G/Y) 27 1.5 0.6 25 1229

RATING TABLES
The information in this datasheet is for guidance only and subject to change without liability. Images provided are representations; actual cable dimensions may vary due to manufacturing tolerances.

[email protected] | www.batt.co.uk | 01322 441165


©2024 Batt Cables Limited

You might also like