0% found this document useful (0 votes)
49 views84 pages

KDK Company Profile

KDK, founded in 1909, aims to improve indoor air quality through innovative ventilation and air-related products, establishing a strong global presence. The company emphasizes its commitment to sustainability and customer satisfaction by developing energy-efficient technologies and solutions. Key milestones highlight KDK's growth and expansion into various international markets, enhancing its reputation as a leader in indoor air quality solutions.

Uploaded by

aadil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views84 pages

KDK Company Profile

KDK, founded in 1909, aims to improve indoor air quality through innovative ventilation and air-related products, establishing a strong global presence. The company emphasizes its commitment to sustainability and customer satisfaction by developing energy-efficient technologies and solutions. Key milestones highlight KDK's growth and expansion into various international markets, enhancing its reputation as a leader in indoor air quality solutions.

Uploaded by

aadil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 84

Marketing

Profile
TABLE OF
CONTENTS

1.3.....................Company Mission

1.4.....................Marketing Map

1.5.....................IAQ (Indoor Air Quality) Solutions

1.6.....................Important Milestones

1.8.....................Ventilation Equipment

1.10....................Home Appliance & Business Solution

1.12....................Event Highlights

1.13....................Corporate Social Responsibilities

1.14....................Our Supports

1.2
COMPANY MISSION

To contribute to the society by


improving Indoor Air Quality in
homes with our premium products
and professional industry expertise.

Kawakita Denki Kigyosha


Founder, KDK Company

1.3
MARKETING MAP

KDK is the short form for Kawakita Denki Kigyosha which was founded since 1909 in Japan. Started
from "Typhoon Type Electric Fan", the Company has been manufacturing a wide range of air-related
products, including ventilating fans, ceiling fans, etc. that contributes indoor air quailty (IAQ) solutions to
its customers. For a century, KDK has established its business in various countries, building its
reputation and brand value in the minds of its customers.

For a century, KDK has established its business in various countries, building its reputation and brand
value in the minds of its customers. Moving forward, in addition to continuous development in existing
markets, we will explore new business in potential markets throughout other fast-growing regions.

PESESGD PESESGD-BJ PESES

UAE

Hong Kong (Marketing Headquarter)

PMMA

KDKM (Sales Co.)


Representative Office
KDK Market
KDKI (Sales Co.)
Manufacturing Base
PMI PESESTH PTW

Market Prospect
Hong Kong
Hong Kong is a global business city and located in the heart of Asia, operation office of oversea marketing
is set up there to play a vital role between markets and factories.
South East Asia
South East Asia is one of the most important regions for KDK, the businesses have started in some
markets for more than 60 years. The region continues its steady growth in upcoming decades with
expected rising demand. In response to the expanding markets, KDK established its sales company in
Indonesia and Malaysia in 2001 and 2002 respectively.
Middle East
Having over 56 years of history in the Middle East, we have set up our respresentative office in Dubai 19
years ago, that allowed us to work closely together with our business partners to provide high level of
service to customers.
Latin America
Latin America is one of the regions in which KDK’s overseas business has been running for more than 58
years. In order to further expand the scale of business and to provide well-quality services to our
customers, a representative office was set up in Mexico in 2013.
Africa
As one of the potential markets, we collaborate power from the leading customers in Africa for generating
business opportunity.
1.4
IAQ SOLUTIONS

Air is the substance which human being take the most into the body as compared with food and water.
Moreover, we spend more than 70% of our time indoors that IAQ (indoor air quality) is essential to our
daily life.
KDK recognizies the importance of IAQ, we has been developing the technologies, solutions and
products that can contribute the benefits to our living environment.

IAQ (Indoor Air Quality) Solutions of KDK for Whole House

Covering up Intake Exhaust Circulation with Energy Saving

Field of IAQ that KDK concerns to cover up

exhaust
gas
NOx SOx
SPM

animals,
plant
pollen Bacteria
natural (mold, virus)
phenomena insects
sand dust,
particle dust
moisture,
dry heat

Circulation
(Purification)

human combustion gas

Intake life act furniture •


instrument
Exhaust
(Purification)

Intake Circulation Exhaust


Not To Take In Healthy / Comfortable Airflow Reduce / Eliminate
Protect unnecessary Inhibit bacteria Exhaust unnecessary
material from the • Celling fan material to the outside
outside • Ventilating fan
• Air purifier
• Energy recovery ventilator • Humidifier • Range hood
• Supply filter unit • Dehumidifier • Bath dryer
• Pipe fan • Electric fan • Pipe fan
• Energy recovery ventilator 1.5
IMPORTANT MILESTONES

Business History
1909 1919 1933 1956 1960
• KDK (Kawakita Denki • Kawakita Denki Co. was • Chuou Denki Co., Ltd. • Osaka Denki Seiki Co., • Registration of new
Kigyousha) was established in Shanghai was established in Ltd was established KDK Trademark
founded Osaka

1946
• Restarted electric fan
production after World
War II

1962
• Renamed the company
1918 to Matsushita Seiko
• Registration of KDK Co., Ltd
Trademark

• Starting of export
business

1909 1919 1929/1939 1949 1959


1913 1919 1931 1953 1960
• Mass production of • Uzumaki Guard & • Special Fan • Orbital Fan • Revesible Ventilating Fan
Typhoon Type Electric Double Oscillation
Fan Electric Fan

1962
• Ventilating Fan with
• Stand Fan Electric al Shutter

1917 1921
• Single Oscillation (GE • Development of Ceiling
Type) Electric Fan Fan
1935 1963
• Ceiling Fan with Light • Automobile Fan

1964
1927 1958 • Wall (Bracket) Fan
• Wall Fan for Train • Slide Fan (Living Fan)

• Windor Mount
Ventilating Fan

1928
• Ventilating Fan 1959
• Portable Fan (Box Fan)

• Industrial Electric Fan

• Ventilating Fan with


shutter
• Range Hood

1967
• High Pressure
Ventilating Fan

1.6
Product History
1969 1979 1989 1999 2009 2019
• The 60th Anniversary • Established KDK • IFCO was renamed as • Established Oversea • The 100th Anniversary • The 110th Anniversary
Ceremony (the event International Matsushita Seiko Hong Marketing Headquarter of KDK of KDK
was being held every 5 Philippines Corporation Kong International in HIMCO
years since then) [KIPCO] in Philippines Manufacturing Co., Ltd
[HIMCO]
2001
1993 • Set up sales company
1978 1981 • Set up Shunde PT.KDK Indonesia
• Established first KDK • Set up International Matsushita Seiko Co., [KDKI] in Indonesia
distributor KDK Fan Manufacturing Co., Ltd [SHUMCO] in
Products(HK) Co., Ltd Ltd [IFCO] in Hong Kong China. It was renamed
in Hong Kong as Guangdong
• Established KDK 2002
International Matsushita Seiko Co., • Set up sales company
corporation of America Ltd. [GDMESC] in 2003 KDK Fan (M) Sdn. Bhd.
[KINCA] in America and and further changed [KDKM] in Malaysia
TORCAN-KDK to PESGD in 2006
International Co., Ltd.
[TORCAN-KDK] in 1995 2003
Canada • Established Beijing Great • Matsushita Seiko Co.
Wall Matsushita Seiko Ltd was renamed as
Air Conditioning Marsushita Ecology
Equipment Co., Ltd. Systems Co., Ltd. and
1988 [BGMAC] which was further changed to KDK
• Shun Hing Electric Works renamed as PESGD-BJ Company, Division of
and Engineering Co., Ltd in 2005 PES in 2008
was appointed as sales
representative of KDK in
Hong Kong 1996
• PESTH was set up in
Thailand

1969 1979 1989 1999 2009 2019


1969 1979 1994 1999 2009 2019
• Ceiling Mount • Antique Ceiling Fan • Air Purifier • Axial Flow Fan • DC Ceiling Mount • Wide Range Electric
Ventilating Fan Ventilating Fan Fan

2013
1980 • Centrifugal Fan • Mist Sauna
• Desk Fan with Cassette
1971 Player • Mini Sirocco Fan
• Pipe Fan (Room to
Room Fan)

2014
• DC Electric Fan
2002
• Hand Dryer
1981
• Air Curtain • Compact Axial Flow Fan
1972
• Intermediate Duct Fan

2003 • Wall Mount Thermo


• Micro Control Fan • Wireless Remote Ventilator
Control Ceiling Fan
• Roof Ventilator
1976
• Energy Saving Ventilator
2015
• DC Ceiling Fan

1984
• Evaporative Air • Dehumidifier
Refresher

1978 • Ball Fan


• Room Fan (Box Fan)

• Cool Fan 2005


• Thermo Ventilator 2016
• Energy Recovery
Ventilator

• Water Pump
1986
• Cabinet Fan

2017
• Mist Air Cooler

1.7
VENTILATION EQUIPMENT

To provide more pleasant and comfortable living spaces for people around the world, we will continue to
develop a complete portfolio of ventilation products and systems for various application.
By combining our knowledge and experience, a diverse range of innovative ventilation products have been
introduced to create high quality living environment, while offering value-added benefits to our customers.

Technology Highlight
DC (Direct Current) Motor
DC Ceiling Mount Ventilating Fan
With customers becoming more environmentally aware than before, the demand for energy efficient
product is rising. KDK has developed an AC (Alternative Current) direct-input DC ( Direct Current) motor
with unprecedented performance characteristics.
In conventional DC ventilating fan motors, the power and drive circuits are separated from the motor. The
newly designed KDK motor encloses all electronic circuits in a molded casing that enhances energy
efficiency and offers a longer operational life. Its energy efficiency is increased up to 96% as compared
with conventional AC motor.

DC Motor AC Motor

Stator uses electrical magnet while rotor Stator & rotor both uses electrical magnet
uses permanent magnet

Constant Airflow
Ceiling Mount Ventilating Fan
Currently, various models would be selected to fit different locations in your house to overcome static
pressure induced by duct length and elbows. By using new technology, our latest product can fulfill airflow
requirements regardless of the factors that may increase static pressure. When the fan encounters static
pressure, its speed is automatically increased to ensure the rated airflow is achieved.

With Constant Air Volume Without Constant Air Volume

Same air Air volume


volume reduced

Air volume from same model with different duct length are same Air volume from same model with different duct length are different

1.8
Low Noise Design
Ceiling Mount Ventilating Fan
These fans adopt distinctive design of “Resonance-Noise-Absorption
Structure”. It can minimize the transmission of noise from the blower to
exterior, reducing the operation noise to incredibly low levels and create a
tranquil and silent environment for you.
With the “Double Orifice” Structure, noise is effectively absorbed and
reduced between the double orifice and casing.

Advanced Blade Design


Wall / Window Mount Ventilating Fan
The blade design applies advanced aerodynamic principle that minimizes any obstacles against the
airflow. Air Foil Chip is to reduce turbulence at rear edge, and curvature of front edge was improved for
smooth airflow that minimizes fan noise as well.

Leading Edge

Air Foil Chip

Heat Exchange Technology


Energy Recovery Ventilator
Temperature differences between exhaust and intake air during balanced ventilation will increase the
cooling load during hot seasons and the heating load during cold seasons. With our heat exchange
mechanism, heat and moist are exchanged between the exhaust and supply’s air stream. In summer,
outside air supplied into the room is cooled down to a temperature close to that of indoors and vice versa
in winter. It ensures energy saving by this exchange process.

Indoor Return Air Outdoor Fresh Air

Indoor Outdoor
Energy Recovery Ventilator
Indoor Return Air Outside Fresh Air

Filter

Supply Air Exhaust Air

Supply Air Exhaust Air Heat Exchange Element

1.9
VENTILATION EQUIPMENT

In response to the rapid growing demand for indoor air quality (IAQ), KDK, as a leading provider, has
developed a full spectrum of products to satisfy the various needs and requirements of customers.
By applying our cutting edge technologies, we are able to enrich people’s lives with improved indoor air
quality through developing a variety o products.

Technology Highlight

Auto Speed Adjustment by Temperature Sensor


Ceiling Fan / Electric Fan
Equipped with thermal sensor, auto mode can
detect temperature changes and control the fan,
generating the most comfortable air flow.
Changing the wind
velocity according to
measured data

Temperature difference
around the ceiling fan is
adjusted by actual
measured data.

Depending on the room temperature, Auto Mode controls the fans

1/f Yuragi to generate the most comfortable air velocity to human body.

Ceiling Fan / Electric Fan


Our sophisticated technology, the 1/f Yuragi on the Electric Fan, varies air velocity and simulates the
pattern of natural breeze, bringing people a sense of refreshment and comfort. Incorporated with
human-centered technology, the rhythm also maintains your external body temperature and keeps you
in a relaxing physical condition.

Air Speed

Notch Change Pattern


Time (s)
Pattern Period 128 sec

Speed notch toggles based on 1/f Yuragi pattern

Super alleru-buster
Electric Fan / Air Cooler / Air Purifier / Dehumidifier
Some of our Indoor Air Quality Appliances, such as Electric Fans and air
purifier, are equipped with anti-bacteria filters which consist of three
features, Super alleru-buster, Anti-Bacteria Emzyme and Green Tea
Catechin. These three features can inhibit 99% of allergens and
eliminate bacteria, keeping your room fresh and clean. Absorb and inhibit allergens

1.10
nanoeTM
Air Purifier / Electric Fan
nanoeTM is long-life micro particies created from water, it can penetrate into fabrics thoroughly and reach
in far corners to inhibit pollutants. As the ions are wrapped in water moiecules that the effect is
long-lasting. Furthermore, nanoeTM is generated from condensed moisture in the air that water
replenishment is not required.

Mist
Air Cooler
Differing from typical evaporation, KDK mist technology lower room temperature more efficiently. Small
amount of water is pumped up inside the vessel by the rotation of the rotor and silky mist is generated by the
crashing ring. The mist is evaporated and blown out of the vessel by airflow for absorbing warm air energy.
Size of mist particles generated by KDK mist technology is 6 times smaller than steam particles and 1000
times smaller than the cooling particles from typical evaporation.

W-HEXS (Dual Dehumidifier System)


Dehumidifier
The multi-layer dehumidification membranes of W-HEXS enable additional air inlet direction, by which
cool and hot air flow across for condensation. This process significantly improves power efficiency of
dehumidification as compared with single air flow of conventional dehumidification system.
Multi-layer Dehumidification Membrane

Dry Air
Indoor
Humid Air
Condenser
Evaporator

Condenser Indoor
Humid Air

Indoor Dry Air


Humid Air
Multi-layer
Compressor

Cooled Air Dehumidification


(from Evaporator) Membrane

Evaporator
Condensed Water W-HEXS Dual Dehumidifier System
1.11
EVENT HIGHLIGHTS

To introduce KDK products and listen to the voices of customer, we have participated different exhibition
and conventions all over the markets.

1) WORLDBEX Exhibition, Philippines (2019) 2) Arechtict EXPO, Sri Lanka (2019) 3) BIG 5 Expo, UAE (2018)

4) Construction Expo, Sri Lanka (2018) 5) KDK Partnership Celebration, Sudan (2017) 6) Mega Expo, Mynamar (2017)

7) BIG 5 Expo, UAE (2017) 8) KDK Showroom Opening Ceremony, Mynamar (2016) 9) Build-4-Asia Building Exhibition,
Hong Kong (2016)

10) Pekan Raya, Indonesia (2016) 11) AHR Expo, Mexico (2016) 12) VIET BUILD, Vietnam (2016)
1.12
CORPORATE SOCIAL RESPONSIBILITIES

As a company with Corporate Special Responsibility at the core, we will never forget to set the
environmental protection as our priority goal to achieve besides product innovation and customers
satisfaction.

Under normal circumstances, KDK’s products are not mandatory to comply with the Restriction of
Hazardous Substances (RoHS) regulation for their markets. Nevertheless, we recognize our responsibility
to the society and therefore, commit ourselves to conforming to the RoHS requirements. We have invested
a lot of resources and implement such pro-environmental policy. In 2006, we were proud to announce that
all our products follow the RoHS requirement.

In addition, KDK has demonstrated its commitment to providing


quality air to the environment, and was finally certified under the
standards of ISO14001 Environmental Management and
ISO9001 Quality Management.

Our care for the Earth has been proven by the newly-launched
products or parts, such as DC motor, Auto Mode for ceiling fan,
HP motor, etc. They are characterized by functions that help
enhance energy conservation. ISO9001 Certificate ISO14001 Certificate

In the age of information, we understand the importance of


information security. We have acquired ISO27001, the
Information Security Management in 2009. It further shows our
commitment to protecting the right of our customers.

In response to our commitment to contributing the society, KDK


also involves in a wide scale of CSR-related activities that builds
close relationship with local communities around the world.

Clarity Event, Vietnam (2017)

1.13
OUR SUPPORTS

Web Communication
To cope with the rapid development of worldwide network, KDK web site
has been launched to provide a platform for us to communicate with our
customers worldwide, and in an effective manner.

Product Selection Program


This program provides a tool for customers to select applicable
models of ventilation products by simply inputting the required
criteria.
The program can be accessed via KDK homepage
or DVD.

Product Selection DVD

Home Ventilation
With this animated program, the customers can understand the
likely sources of air problems and the solutions in a house.

Product Seminar / Training


To further enhance our value as a leading provider of indoor air
quality products, we continuously provide various types of seminar
and training to our business partners so the highest standard of
the services can be maintained.

1.14
PRODUCT INDEX

Product Index
Page Number Content

2.1 - 2.3 Product Overview

2.4 - 2.11 Air Moving Equipment


2.4 Compact Axial Fan
2.7 Mini Sirocco Fan
2.9 Accessories (Vent Cap & Pipe Hood)
2.10 Roof Ventilator
2.11 General Information

2.12 - 2.16 Energy Recovery Ventilator


2.12 Standard Series
2.15 ERV Accessory & Filter Box
2.16 Specification Summary

2.17 - 2.25 Ceiling Mount Ventilation Fan


2.17 Super Quite Series
2.21 Standard Series
2.22 DC Motor Series
2.24 Metal Series

2.26 - 2.31 Cabinet Fan


2.26 Single Phase Series
2.30 Three Phase Series

2.32 - 2.37 Industrial Ventilation Fan


2.32 High Pressure Series
2.36 Shutter Series

2.38 - 2.48 Wall Mount Ventilation Fan


2.38 Filter Series
2.39 Automatic Shutter Series
2.42 Automatic Shutter Louver Series
2.44 Reversible Series
2.46 Reversible Louver Series
2.48 Metallic Series

2.49 - 2.52 Window Mount Ventilation Fan


2.49 High Pressure Deluxe Series
2.50 Electric Shutter Series
2.51 Automatic Shutter Series
2.52 Cord-operated Shutter Series

2.53 - 2.58 Specification Summary

2.59 - 2.60 Air Curtain


2.59 Cross Flow Type
2.60 Sirocco Type
PRODUCT OVERVIEW

IEC standard compliance, GSO certified, ESMA, KUCAS, SASO, SONCAP


Models licensed to bear the AMCA certified seal: 15AAQ1, 20AUHT, 25AUHT, 30AUHT,
20AUH, 25AUH, 30AUH 11, 20ALHT, 25ALHT, 30ALFT, 20ALH, 25ALH, 30ALF 11,
20ASB, 25ASB, 30ASB, 20ASB 05, 25ASB 05, 30ASB 05

IEC standard compliance, GSO certified, ESMA, KUCAS, SASO, SONCAP


Models licensed to bear the AMCA certified seal: 15WHCT, 20WHCT, 15WAA,
20WAA, 15WAAMN, 20WAAMN,15WUD, 20WUD

IEC standard compliance, GSO certified, ESMA, KUCAS, SASO, SONCAP


Models licensed to bear the AMCA certified seal: 25GSE, 30GSE, 35GSE, 40GSE,
45GSC, 50GSC, 60GSC

2.1
PRODUCT OVERVIEW

Models licensed to bear the AMCA certified seal: 12NSB, 15NSB, 18NSB, 18NFB,
20NSB, 23NLB, 25NSB, 25NFB

2.2
PRODUCT OVERVIEW

2.3
Compact Axial Flow Fan

Construction Main components and materials

Specifications

2.4
Compact Axial Flow Fan
Performance Data

2.5
Compact Axial Flow Fan
Dimensions

2.6
Mini Sirocco Fan

Specifications

2.7
Mini Sirocco Fan
Performance Data

Wiring Diagram

2.8
ACCESSORIES
Vent Cap & Pipe Hood

2.9
Roof Ventilator

Specifications

Specifications

2.10
General Information

Compact axial flow fan

Mini sorocco fan

2.11
ENERGY RECOVERY VENTILATOR
Standard Series

Product Dimension
Maintenance Dimension
E25DZUA
It must be set the maintenance door, and clean the filter
and heat exchange core as specified in instruction.

220 695 220


2
151

151
ø160
ø144

ø144
ø160

129 (Exhaust Air) (Supply Air) 91


70
402

418
693
750

(Outside Air) 129

• Counter-flow heat-exchange element adopted


(Room Air)
ø210
ø194

ø144
ø160

90
96
for compact size
• All maintenance can be performed through a single
1
96

26 8 5 4 3

inspection hole
R6.5
13

ø160
ø144

70 7 6
• Equipped with Extra-High setting
Ceiling
suspension parts
Internal structure after
opening the maintenance cover • Bypass ventilation available for speedy exhaust
• Interlock with air conditioning available
Installation method for case 1

427 695 KDK Company, Division of PES and Panasonic


2 2
Ecology Systems Guangdong Co., Ltd. certify that
9
the industrial series models shown herein are
licensed to bear the AMCA Seal. The ratings
693

shown are based on the tests and procedures


2

performed in accordance with AMCA Publication


535
2

211 and comply with the requirements of the


AMCA Certified Rating Program.
500

450
1

450 100

No. Part name Qty Material


615
600

1
3
450

649
853
1

450 The area within double point chain


1
line is reserved for maintenance,
600 it’s prohibited to place other devices.
3 1110 1 Frame 1 Galvanized Steel Sheet

Installation method for case 2 2 Adapter 4 ABS

3 Impeller 2 PP
695 427
2 2

4 Fan Motor 1 /
693
2

5 Heat Exchange Core 1 Special Paper and Resin


535
2

6 Indoor Filter 1 /
500
450
1

100 450
7 Ceiling Suspension 4 Galvanized Steel Sheet
615

600

1
3

450

649
865

450
8 Switch Box 1 Galvanized Steel Sheet
The area within double point chain 1
line is reserved for maintenance,
it’s prohibited to place other devices. 600
1110 3

9 Filter Box Unit - /

Specification
CFM AT Static Pressure (ps-inches of H2O) Watts* Watts**
Model No. Voltage Frequency
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.75 1 1.25 1.5 1.75 For AMCA For IEC

CFM (OA-SA) 183 172 168 155 143 131 108 77 14 - - 197
E25DZUA 220V 60Hz 171
CFM (RA-EA) 130 118 115.5 104 91 77 44 0 - - - 187

Performance certified is for installation type D-Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Performance ratings do not include the effects of appurtenances (accessories). Air performance ratings for gross supply airflow are from port 2. Air performance ratings for gross exhaust airflow are to port 3.
*The Watts ratings is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** The Watts rating is only for IEX test method and AMCA Certified Rating Seal does not apply to IEC test method watts.
2.12
ENERGY RECOVERY VENTILATOR
Standard Series

Product Dimension
E35DZUA Maintenance Dimension
It must be set the maintenance door, and clean the filter
and heat exchange core as specified in instruction.

230 230
723
2 680

153

168
ø160
ø144

ø144
ø160
136 (Exhaust Air) (Supply Air) 94
70

525
533
114

858
920
110

• Counter-flow heat-exchange element adopted (Outside Air) (Room Air)

for compact size

ø210
ø194

ø144
ø160
90

• All maintenance can be performed through a single 1


96

95
inspection hole
8 5 4 3
26
R6.5

• Equipped with Extra-High setting

13

115
• Bypass ventilation available for speedy exhaust
70
7 6
Internal structure after
opening the maintenance cover

• Interlock with air conditioning available


Ceiling
suspension parts

Installation method for case 1


KDK Company, Division of PES and Panasonic 427
2
723
2
Ecology Systems Guangdong Co., Ltd. certify that
the industrial series models shown herein are
licensed to bear the AMCA Seal. The ratings 9

shown are based on the tests and procedures

858
performed in accordance with AMCA Publication

2
211 and comply with the requirements of the
535
2

AMCA Certified Rating Program.


500

450
No. Part name Qty Material 1 450
615
600

1 100
3
450

865
1

654
450
1

1 Frame 1 Galvanized Steel Sheet


The area within double point chain
600 line is reserved for maintenance,
3 1110 it’s prohibited to place other devices.

2 Adapter 4 ABS Installation method for case 2


723 427

3 Impeller 2 PP
2 2

4 Fan Motor 1 /
9
858
2

5 Heat Exchange Core 1 Special Paper and Resin


535
2

6 Indoor Filter 1 /

7 Ceiling Suspension 4 Galvanized Steel Sheet


500
450
1

450
600
615

100 1
3

450
865

654
8 Switch Box 1 Galvanized Steel Sheet 450
1
The area within double point chain 600
line is reserved for maintenance, 3
it’s prohibited to place other devices. 1110

9 Filter Box Unit - /

Specification
CFM AT Static Pressure (ps-inches of H2O) Watts* Watts**
Model No. Voltage Frequency
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.75 1 1.25 1.5 1.75 For AMCA For IEC

CFM (OA-SA) 258 250 247 237 225 211 174 144 118 69 - 348
E35DZUA 220V 60Hz 310
CFM (RA-EA) 192 183 180 169 157 144 116 84 49 0 - 342
Performance certified is for installation type D-Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Performance ratings do not include the effects of appurtenances (accessories). Air performance ratings for gross supply airflow are from port 2. Air performance ratings for gross exhaust airflow are to port 3.
*The Watts ratings is only for AMCA test method and it is at the static pressure of 0 inch of H2O.** The Watts rating is only for IEX test method and AMCA Certified Rating Seal does not apply to IEC test method watts.

2.13
ENERGY RECOVERY VENTILATOR
Standard Series

Product Dimension
Maintenance Dimension
E50DZUA
It must be set the maintenance door, and clean the filter
and heat exchange core as specified in instruction.

723 240
2 680 120
177

168
194
210
210
194

(Exhaust Air) (Supply Air)


120
70
662

1026
1090

671

(Outside Air) (Room Air)


• Counter-flow heat-exchange element adopted
for compact size
ø210
ø194

194
210

90 96
• All maintenance can be performed through a single
inspection hole
95

26 1 8
R6.5 5 4 3

• Equipped with Extra-High setting


13

ø210
ø194

ø194
ø210
120

70
7 6 • Bypass ventilation available for speedy exhaust
Ceiling Internal structure after
suspension parts opening the maintenance cover
• Interlock with air conditioning available
Installation method for case 1
426
2
723
2
KDK Company, Division of PES and Panasonic
Ecology Systems Guangdong Co., Ltd. certify that
the industrial series models shown herein are
licensed to bear the AMCA Seal. The ratings
9
shown are based on the tests and procedures
1026

performed in accordance with AMCA Publication


2

211 and comply with the requirements of the


535

AMCA Certified Rating Program.


2

No. Part name Qty Material


500

450
1
600

100
3

450
450

1
615
865
1

450 655
1
600
3 1110
The area within double point chain
line is reserved for maintenance,
it’s prohibited to place other devices.
1 Frame 1 Galvanized Steel Sheet

Installation method for case 2 2 Adapter 4 ABS


723 427
2 2
3 Impeller 2 PP

4 Fan Motor 1 /
9
1026

5 Heat Exchange Core 2 Special Paper and Resin


2

535
2

6 Indoor Filter 1 /

7 Ceiling Suspension 4 Galvanized Steel Sheet


500
450
1

100
600

450
615

450
3

1
8 Switch Box 1 Galvanized Steel Sheet
1

655 450
865

1
The area within double point chain
line is reserved for maintenance, 600
3
9 Filter Box Unit - /
it’s prohibited to place other devices. 1110

Specification
CFM AT Static Pressure (ps-inches of H2O) Watts* Watts**
Model No. Voltage Frequency
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.75 1 1.25 1.5 1.75 For AMCA For IEC

CFM (OA-SA) 339 330 326 314 303 290 261 230 188 134 80 470
E50DZUA 220V 60Hz 406
CFM (RA-EA) 253 241 238 224 207 190 154 117 82 41 - 443

Performance certified is for installation type D-Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test.
Performance ratings do not include the effects of appurtenances (accessories). Air performance ratings for gross supply airflow are from port 2. Air performance ratings for gross exhaust airflow are to port 3.
*The Watts ratings is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** The Watts rating is only for IEX test method and AMCA Certified Rating Seal does not apply to IEC test method watts.
2.14
ENERGY RECOVERY VENTILATOR
Accessory & Filter Box

EB90SA
• Applicable to series DZUA
• Power: 220V / 60Hz
• Rate voltage: 3.6W
• Outter size: 86x86x40mm

Filter Box Unit


BE25DZUA For E25DZUA, E35DZUA BE50DZUA For E50DZUA

UNIT: mm UNIT: mm
240 350
2
2
284

284

302
302

air air air air


inlet outlet inlet outlet
600

600
120 121 175 176

1 1
4 4 3 3
26 3 3 26
R6.5 R6.5
13

13

210
194

194
210
194

194

Ceiling Draw out the Ceiling Draw out the


suspension parts Filter Unit suspension parts Filter Unit

No. Part name Qty Material No. Part name Qty Material
1 Frame 1 Galvanized Steel Sheet 1 Frame 1 Galvanized Steel Sheet
2 Adapter 2 ABS 2 Adapter 2 ABS
3 Outdoor filter 2 Nonwoven Fabric 3 Outdoor filter 2 Nonwoven Fabric
4 Ceiling Suspension 4 Galvanized Steel Sheet 4 Ceiling Suspension 4 Galvanized Steel Sheet

Replacement Filter
Filter(s) Service life
Product name Filter Model Included Applicable Model of the filter Remarks
Replacement filter FP25DZUA 2 BE25DZUA
2-4 months
for Filter Box Unit FP50DZUA 2 BE50DZUA
FB25DZUA 1 E25DZUA Clean monthly
Replacement filter
FB35DZUA 1 E35DZUA 6 months
for ERV
FB50DZUA 1 E50DZUA
• The service life of the filters varys with service environment, and the filters should be replaced with the new one.
• The air volume and filter efficiency will drop to different levels because of different service environments and service time. If the whole area indicated by the arrow turns black, please replace the filter.

2.15
ENERGY RECOVERY VENTILATOR
Product Specification

CFM AT Static Pressure (ps-inches of H2O) Watts* Watts**


Model No. Voltage Frequency
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.75 1 1.25 1.5 1.75 For AMCA For IEC

CFM (OA-SA) 183 172 168 155 143 131 108 77 14 - - 197
E25DZUA 220V 60Hz 171
CFM (RA-EA) 130 118 115.5 104 91 77 44 0 - - - 187

CFM (OA-SA) 258 250 247 237 225 211 174 144 118 69 - 348
E35DZUA 220V 60Hz 310
CFM (RA-EA) 192 183 180 169 157 144 116 84 49 0 - 342

CFM (OA-SA) 339 330 326 314 303 290 261 230 188 134 80 470
E50DZUA 220V 60Hz 406
CFM (RA-EA) 253 241 238 224 207 190 154 117 82 41 - 443

Preformance certified is for installation type D: Duct inlet, Duct outlet.


Performance is based on actual speed of test.
* The Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** The Watts rating is only for IEC test method and AMCA Certified Rating Seal does not apply to IEC test method watts.

Size (mm) 650 x 750 x 220 680 x 920 x 230 680 x 1090 x 240
Weight 30 39 45
Main
OA Side Duct Diameter ø200
Body
Duct Diameter
ø150 ø200
RA/SA/EA

Up-Side Down Installation Yes

Duct Diameter ø200


Filter Box
Size (mm) 600 x 385 x 240 600 x 385 x 350

2.16
CEILING MOUNT VENTILATION FAN
Super Quiet Series

17CUG/ Product Dimension


17CUGA
290
170

ø98
164

38
240
• Super low noise design

20
• Long life ball bearing motor
• Taper blade sirocco fan
• Resonance-Noise-Absorption
214

Structure
194

100
• Reverse flow prevention shutter
• Pre-installed power cord
84

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Super
Quiet Series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**

41 28 25
220V 60Hz 810 11 10
17CUG/ 0.3 0.5 0.6
17CUGA 50 43 40
240V 50Hz 780 12 10.5
0.3 0.4 0.6

Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.17
CEILING MOUNT VENTILATION FAN
Super Quiet Series

24CUG/24CDG/
24CHG
Product Dimension

352
230

• Super low noise design


• Long life ball bearing motor
ø98

• Taper blade sirocco fan


175

• Resonance-Noise-Absorption
42

Structure
300
• Reverse flow prevention shutter
13

• Pre-installed power cord

KDK Company, Division of PES and


Panasonic Ecology Systems Guangdong
Co., Ltd. certify that the Super Quiet
278
255

Series models shown herein are licensed


100

to bear the AMCA Seal. The ratings shown


are based on tests and procedures
performed in accordance with AMCA
Publication 211 and AMCA Publication
140
311 and comply with the requirements of
the AMCA Certified Ratings Program.

Specification

Watts* Watts**

83 73 68 44
220V 60Hz 610 16 15.5
0.5 0.6 0.6 1.4
24CUG
88 77 75 51
240V 50Hz 680 15.1 14
0.7 0.8 0.9 1.6
101 90 88 64
220V 60Hz 750 18.2 16.5
0.7 0.8 0.9 1.5
24CDG
105 91 86 64
240V 50Hz 780 18.6 17.5
0.8 0.9 1.0 1.7
109 99 96 75 47
220V 60Hz 860 23.6 22
1.0 1.2 1.2 1.5 2.4
24CHG
116 100 94 72 33
240V 50Hz 890 23.5 22
1.2 1.3 1.4 1.6 2.1
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.18
CEILING MOUNT VENTILATION FAN
Super Quiet Series

27CHH Product Dimension

• Super low noise design


• Long life ball bearing motor
• Taper blade sirocco fan
• Resonance-Noise-Absorption
Structure
• Pre-installed power cord
• 2 speed selectable

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Super
Quiet Series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**

182 162 158 118 78 37


220V 60Hz Hi 570 33 33
1.1 1.2 1.3 1.7 2.2 2.5
27CHH
198 179 172 126 78 18
240V 50Hz Hi 609 37 34
1.4 1.5 1.6 1.8 2.3 2.5

Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.19
CEILING MOUNT VENTILATION FAN
Super Quiet Series

Product Dimension
32CDH

• Super low noise design


• Long life ball bearing motor
• Taper blade sirocco fan
• Resonance-Noise-Absorption
Structure
• Pre-installed power cord
• 2 speed selectable

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Super
Quiet Series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**

226 202 196 163 127 91 53


220V 60Hz Hi 580 48 48
1.2 1.3 1.4 1.7 2.2 2.7 3.3
32CDH
257 236 230 192 147 99 53
240V 50Hz Hi 675 56 50
1.6 1.7 1.8 1.9 2.5 3.0 3.6
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.20
CEILING MOUNT VENTILATION FAN
Standard Series

38CDG/
38CDG 05 Product Dimension

• High-Low speed selectable


• Condenser motor with thermal
cut-off
• Well lubricated bearing for long
life operation
• High performance sirocco fan

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Standard
models shown herein are licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875
344 323 317 290 261 230 197 163 126
38CDG 220V 60Hz Hi 626 98 98
3.1 3.2 3.2 3.3 3.6 4.1 4.5 5.7 5.7
38CDG 05 387 367 362 336 305 259 212 165 108
240V 50Hz Hi 737 118 104
38CDG 4.0 4.1 4.2 4.3 4.4 4.7 5.3 5.7 6.2
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.21
CEILING MOUNT VENTILATION FAN
DC Motor Series

Product Dimension
24JRB

• DC (Direct Current) motor


• Auto operation by motion sensor
• Constant airflow
• Variable air volume
• Delay timer (15 minutes)
• Resonance-Noise-Absorption
Structure

The operation of whole house ventilation and spot ventilation

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the DC Motor
models shown herein are licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875
88 88 88 88 63 34 5 --- --
220V 60Hz Hi
0.7 1.0 1.0 1.3 1.7 1.8 3.1 --- ----
24JRB 853 10 8
88 88 88 88 63 34 5 --- ---
240V 50Hz Hi
0.7 1.0 1.0 1.3 1.7 1.8 3.1 --- ---
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.22
CEILING MOUNT VENTILATION FAN
DC Motor Series

24JAB Product Dimension

• DC (Direct Current) motor


• Constant airflow
• Variable air volume
• Delay timer (15 minutes)
• Resonance-noise-Absorption
Structure

The operation of whole house ventilation and spot ventilation

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the DC Motor
models shown herein are licensed to bear the AMCA
Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**
0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875
88 88 88 88 63 34 5 --- --
220V 60Hz Hi
0.6 0.9 1.0 1.4 1.6 1.9 3.2 --- ----
24JAB 839 10 8
88 88 88 88 63 34 5 --- ---
240V 50Hz Hi
0.6 0.9 1.0 1.4 1.6 1.9 3.2 --- ---

Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.23
CEILING MOUNT VENTILATION FAN
Metal Series
Fire
Resistant

24CMUA
Product Dimension /24CMHA

103
300
278
255
140

231
ø98

• All metal structure design


17 200
• Long life ball bearing motor
• Metallic components within
air stream provides extra safety
against fire
• Reverse flow prevention shutter

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Metal
Series models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**

55 40 37 20
220V 60Hz 495 13 12
0.3 0.7 0.8 1.6
24CMUA
55 44 41 24
240V 50Hz 562 14 13
0.3 0.8 1.0 1.4
94 85 83 72 54
220V 60Hz 681 25 23
1.0 1.4 1.5 1.9 2.3
24CMHA
108 98 95 77 44
240V 50Hz 753 27 25
1.4 1.8 1.9 2.1 2.2
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.24
CEILING MOUNT VENTILATION FAN
Metal Series
Fire
Resistant

27CMHA Product Dimension

360
270 (Installation Size)
263

ø148
240
30

112
• All metal structure design Ceiling Board
25-30

330

• Long life ball bearing motor


• Metallic components within
air stream provides extra safety

307
284
41.5
against fire

70
• Reverse flow prevention shutter
140

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the Metal
Series models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification

Watts* Watts**

208 184 178 144 108 79


220V 60Hz 615 46 43
1.6 1.7 1.7 2.3 3.2 3.5
27CMHA
219 194 188 150 110 70
240V 50Hz 669 46 43
1.9 1.9 2.0 2.4 3.4 3.1

Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.25
CABINET FAN
Low Noise Type – Single Phase Series

12NSB/
Product Dimension
15NSB

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the low noise
series cabinet fan models shown herein are licensed to
bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.

Specification

114 105 102 87 65


220V 60Hz Hi 1,460 26 23
1.5 1.4 1.4 1.3 1.4
12NSB
102 90 86 67 39
240V 50Hz Hi 1,342 27 22
2.0 1.7 1.6 1.4 1.5
200 183 177 149 118 83
220V 60Hz Hi 1,520 45 42
2.7 2.5 2.4 2.3 2.2 2.0
15NSB
193 177 172 139 94 20
240V 50Hz Hi 1,373 47 37
3.7 3.4 3.2 2.6 2.5 2.8
Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation Type D: ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.26
CABINET FAN
Low Noise Type – Single Phase Series

18NSB/
Product Dimension
18NFB

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the low noise
series cabinet fan models shown herein are licensed to
bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.

Specification

274 261 258 241 222 196 137


220V 60Hz 1,470 80 73
3.3 3.1 3.0 2.9 2.7 2.6 2.7
281 263 259 232 200 163 34
240V 50Hz Hi 1,342 84 68
4.8 4.4 4.4 3.8 3.4 3.0 2.9
417 399 395 373 347 318 237
220V 60Hz 1,420 128 119
4.0 3.9 3.9 3.9 3.6 3.5 3.4
429 406 400 381 344 290 78
240V 50Hz Hi 1,327 135 104
5.6 5.4 5.4 5.1 4.6 4.3 4.2
Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation Type D: ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.27
CABINET FAN
Low Noise Type – Single Phase Series

20NSB/
Product Dimension
23NLB

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the low noise
series cabinet fan models shown herein are licensed to
bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.

Specification

469 459 456 444 433 413 354 275


220V 60Hz 1,380 170 159
4.0 4.0 3.9 3.8 3.9 4.0 4.1 4.2
517 500 495 464 424 382 265 110
240V 50Hz Hi 1,328 175 135
6.0 5.8 5.8 5.4 5.1 4.8 4.5 4.5
655 642 640 625 611 597 555 505 440
220V 60Hz 1,400 350 310
23NLB 6.0 6.0 5.9 5.9 5.7 5.7 5.8 5.8 5.8
688 670 664 642 614 579 493 388 199
240V 50Hz Hi 1,342 347 260
8.8 8.6 8.4 8.1 8.0 7.6 7.2 6.7 6.6
Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation Type D: ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.28
CABINET FAN
Low Noise Type – Single Phase Series

25NSB/
Product Dimension
25NFB

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the low noise
series cabinet fan models shown herein are licensed to
bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with
AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.

Specification

940 924 919 899 877 857 790 710 610 502
220V 60Hz Hi 1,380 460 425
7.1 7.1 7.1 7.0 6.8 6.8 6.7 6.7 6.7 6.9
25NSB
963 938 935 906 868 822 719 567 395
240V 50Hz Hi 1,305 481 370
10.1 9.8 9.7 9.3 9.2 8.8 8.0 7.5 8.2
1,016 1,000 995 975 954 933 875 803 710 590
220V 60Hz Hi 1,420 680 520
8.2 8.2 8.2 8.2 7.9 7.9 7.8 7.6 7.5 7.5
25NFB
1,057 1,048 1,040 1,010 972 922 811 660 473
240V 50Hz Hi 1,330 537 430
12.1 11.9 11.5 11.1 10.6 9.8 8.7 8.7 10.3
Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation Type D: ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.29
CABINET FAN
Low Noise Type - Three Phase Series

25SWC/
Product Dimension
25SMC

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

Performance Data [380V 50/60Hz]

Specification

[V] [Hz]

Note: The value in specification tables are representative characteristic value at 380V 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.
2.30
CABINET FAN
Low Noise Type - Three Phase Series

28NXC Product Dimension

• Long life condenser motor


with thermal cut-off
• Twin flow fan (sirocco fan)
• Fan casing with tapered scroll
• Embedded terminal box
• Noise absorption material adopted
• Compact size

Performance Data [380V 50/60Hz]

Specification

[V] [Hz]

Note: The value in specification tables are representative characteristic value at 380V 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.31
INDUSTRIAL VENTILATION FAN
High Pressure Series

25GSE/30GSE/
Product Dimension
35GSE

• Single phase
• Reversible by adjusting wiring
and blade
• Bell mouth construction with
distinctive wave-shaped blade
Model A B C D E F G H • Durable powder coating
25GSE 327 298 165 - 171 10 - 250
• High performance motor
30GSE 378 349 210 - 200 10 - 300
35GSE 467 434 250 - 236 12 - 350
with thermal cutoff
• Ambient temperature range
KDK Company, Division of PES and Panasonic Ecology from -10ºC to +50ºC
Systems Guangdong Co., Ltd. certify that the industrial series • Possible to install horizontally
models shown herein are licensed to bear the AMCA Seal. The
or vertically
ratings shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA Publication • Optional Shutter available
311 and comply with the requirements of the AMCA Certified
Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O)
Model Voltage Frequency RPM Watts* Watts**
inches of 0 0.05 0.075 0.1 0.125 0.25 0.375
H2O
CFM 788 742 715 686 647 - -
220V 60Hz 1570 61 57
Sones 4.9 4.7 4.5 4.5 4.6 - -
25GSE
CFM 701 657 633 600 565 187 -
240V 50Hz 1400 48 44
Sones 3.8 3.6 3.6 3.5 3.6 8.6 -
CFM 1308 1247 1217 1184 1153 772 -
220V 60Hz 1460 129 119
Sones 9.0 9.0 9.1 9.0 9.1 9.4 -
30GSE
CFM 1177 1119 1090 1058 1026 561 243
240V 50Hz 1315 106 98
Sones 5.5 5.5 5.6 5.6 5.8 11.1 12.0
CFM 1850 1788 1752 1712 1669 1456 600
220V 60Hz 1640 178 161
Sones 11.9 11.6 12.0 12.4 13.6 14.6 13.4
35GSE
CFM 1615 1548 1506 1458 1411 1147 390
240V 50Hz 1435 130 122
Sones 8.6 8.2 8.2 8.0 8.0 12.6 13.4
Performance certified is for installation type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound
ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for
installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.32
INDUSTRIAL VENTILATION FAN
High Pressure Series

40GSE Product Dimension

• Single phase
• Reversible by adjusting wiring
and blade
• Bell mouth construction with
distinctive wave-shaped blade
• Durable powder coating
Model A B C D E F G H
• High performance motor
40GSE 518 485 280 460 274 12 12 400
with thermal cutoff
• Ambient temperature range
from -10ºC to +50ºC
• Possible to install horizontally KDK Company, Division of PES and Panasonic Ecology
or vertically Systems Guangdong Co., Ltd. certify that the industrial series
models shown herein are licensed to bear the AMCA Seal. The
• Optional Shutter available
ratings shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the AMCA Certified
Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O)
Model Voltage Frequency RPM Watts* Watts**
inches of 0 0.05 0.075 0.1 0.125 0.25 0.375
H2O

CFM 2677 2581 2535 2488 2440 2170 2050


220V 60Hz 1550 294 270
Sones 20.0 20.0 19.7 19.4 19.3 18.9 19.9
40GSE
CFM 2135 2067 2035 2000 1965 1800 1480
240V 50Hz 1440 164 151
Sones 9.0 8.5 8.7 8.7 8.7 13.0 14.2

Performance certified is for installation type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound
ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are
for installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.
2.33
INDUSTRIAL VENTILATION FAN
High Pressure Series

45GSC/50GSC/
Product Dimension
60GSC

• Single phase
• Reversible by adjusting wiring
and blade
• Bell mouth construction with
distinctive wave-shaped blade
• Durable powder coating
Model A B C D E F G
45GSC 450 570 540 - 320 297 12 • High performance motor
50GSC 500 659 620 560 355 315 15 with thermal cutoff
60GSC 620 760 720 650 400 320 15
• Ambient temperature range
from -10ºC to +50ºC
KDK Company, Division of PES and Panasonic Ecology Systems • Possible to install horizontally
Guangdong Co., Ltd. certify that the industrial series models or vertically
shown herein are licensed to bear the AMCA Seal. The ratings
• Optional Shutter available
shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the AMCA Certified
Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model no. Voltage Frequency RPM
inches of H2O 0 0.2 0.3 0.4 FOR AMCA FOR IEC

CFM 3278 3131 3001 2795


220V 60Hz 1563 346 325
Sones 10 10.4 10.6 10.8
45GSC
CFM 2854 2648 2454 2030
240V 50Hz 1430 277 241
Sones 7.8 7.7 7.8 9.4
CFM 3884 3443 3090 2501
220V 60Hz Sones 10.9 11.3 11.5 11.8
1080 347 326
50GSC
CFM 3354 2854 2266 912
240V 50Hz Sones 11.7 13.8 14.5 15.4
968 293 271

CFM 5038 4349 3943 3560


220V 60Hz Sones 10.1 9.8 9.5 10.1
1088 384 361
60GSC
CFM 4402 3855 3366 2972
240V 50Hz Sones
980 289 263
10.3 8.6 8.5 11.5
Performance certified is for installation type A: Free Inlet, Free Outlet. The speed (RPM) and Watts rating shown are at the static pressure of 0 inch of H2O.
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301.
Values shown are for installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.34
INDUSTRIAL VENTILATION FAN
High Pressure Series

45GTC/50GTC/
Product Dimension
60GTC

• Three Phase
• Reversible by adjusting wiring
and blade
• Bell mouth construction with
distinctive wave-shaped blade
• Durable powder coating
• High performance motor
with thermal cutoff
• Ambient temperature range
Model A B C D E F G
from -10ºC to +50ºC
45GTC 450 570 540 - 320 297 12
• Possible to install horizontally
50GTC 500 659 620 560 355 304 15
or vertically 60GTC 620 760 720 650 400 320 15
• Optional Shutter available

Performance Data [380V 50/60Hz]


45GTC 50GTC 60GTC

Specification
Voltage Consumption RPM Air Volume Noise Weight
Model No. Hz [W] [min-1] [dB(A)] [Kg]
[V] [CMH] [CFM]

50 220 1,450 5,520 3,249 52


45GTC 380 18.5
60 330 1,690 6,420 3,779 56
50 320 1,400 6,960 4,097 54
50GTC 380 28.5
60 475 1,590 8,010 4,715 58
50 310 940 9,420 5,544 49
60GTC 380 34
60 450 1,070 10,920 6,427 53
Note: The value in Specification table are representative characteristic value at 380V, 50/60Hz.
RPM data is for reference only. Values may vary subject to different conditions.

2.35
INDUSTRIAL VENTILATION FAN
Shutter Series

30KQT/
Product Dimension
40KQT

• Used in factories, warehouses


or other locations in where powerful
ventilation is necessary
• Metal large blade assembly for
abundant air volume
• Powerful, efficient and durable
condenser motor
Model A B C D E F G H I J K
• Ambient temperature range
30KQT 420 385 305 116 34 40 141 90 340 10 164
40KQT 510 480 410 133 40 52 141 90 434 10 181
from -10ºC to +50ºC

Performance Data [220V 50Hz/60Hz]


30KQT 40KQT

Specification
Voltage Frequancy Consumption RPM Air Volume Noise Weight
Model No. [V] [ Hz ] [W] [min-1] [dB(A)] [Kg]
[CMH] [CFM]

50 42 1,185 1,220 718 46


30KQT 220 4.9
60 51 1,255 1,270 747 47
50 61 1,175 2,060 1,212 49
40KQT 220 6.4
60 76 1,260 2,190 1,289 51
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz.
RPM data is for reference only. Values may vary subject to different conditions.

2.36
INDUSTRIAL VENTILATION FAN
Shutter Series

50AEQ2 Product Dimension

• Used in factories, warehouses


or other locations in where powerful
ventilation is necessary
• Metal large blade assembly for
abundant air volume
• Powerful, efficient and durable
condenser motor
• Ambient temperature range
from -10ºC to +50ºC

Performance Data [220V 50Hz/60Hz]

Specification
Voltage Frequancy Consumption RPM Air Volume Noise Weight
Model No. [V] [ Hz ] [W] [min-1] [dB(A)] [Kg]
[CMH] [CFM]

50 108 920 3,630 2,137 54


50AEQ2 220 11.5
60 130 1,050 4,200 2,472 58
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz.
RPM data is for reference only. Values may vary subject to different conditions.

2.37
WALL MOUNT VENTILATION FAN
Filter Series

Product Dimension 25AUFA

• Recommend to use in kitchen


• Automatic Shutter
• Perforated aluminum filter with
hydrophobic coating
• Large capacity oil cup
• Oil indicator on oil cup
• High exhaust air volume under
actual usage condition (20Pa)

Performance Data [220V 50Hz/60Hz]

Specification
Voltage Frequency Consumption RPM Air Volume Noise Weight Instailation space
Model No. [V] [W] [min-1] [dB(A)] [Kg] [mm ]
[Hz] [CMH] [CFM]

50 34 1,100 835 491 42


25AUFA 220 2.8 300 x 300
60 34 1,060 820 483 42

RPM data is for reference only. Values may vary subject to different conditions.

2.38
WALL MOUNT VENTILATION FAN
Automatic Shutter Series

15AAQ1 Product Dimension

• Condenser motor with thermal cutoff


• Lubricated sintered bush for long life
operation
• High performance propeller fan
adopted
• Automatic shutter with plastic
cushions
• Orifice equipped with oil cup

KDK Company, Division of PES and Panasonic


Ecology Systems Guangdong Co., Ltd. certify that
the wall mount series models shown herein are
licensed to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.025 0.05 FOR AMCA FOR IEC

CFM 157 122 65


220V 50Hz 1533 20.6 19.0
Sones 2.5 1.9 2.3
15AAQ1
CFM 154 120 63
240V 60Hz 1453 20.1 19.0
Sones 1.7 1.4 2.1

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a backdraft shutter. The speed (RPM) and Watts
rating shown are at the static pressure of 0 inch of H2O. Speed (RPM) shown in nominal. Performance is based on actual speed of test. The sound ratings shown
are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation
type A: Free inlet hemispherical sone levels.
*the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
**the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.
2.39
WALL MOUNT VENTILATION FAN
Automatic Shutter Series

20AUH/25AUH/
Product Dimension
30AUH 11

• HP condenser motor with thermal


cutoff
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advanced blade design (except
Model A B C D E F G H 30AUH 11)
20AUH 200 306 260 302 240 52 90 80 • Automatic shutter
25AUH 250 356 310 352 290 38 90 63
30AUH 11 300 406 360 402 340 38 90 78
• Single speed

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the wall mount
series models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.025 0.05 FOR AMCA FOR IEC

CFM 355 314 196


20AUH 220V 60Hz 1410 32.4 28.5
Sones 2.5 2.5 1.7

CFM 514 426 290


25AUH 220V 60Hz 1200 37.8 33.0
Sones 1.8 1.5 1.8

CFM 572 453 235


30AUH 11 220V 60Hz 856 37.0 33.0
Sones 1.0 1.7 2.6

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a backdraft shutter. The speed (RPM) and Watts
rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field
calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
*the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
**the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.40
WALL MOUNT VENTILATION FAN
Automatic Shutter Series

20AUHT/
25AUHT/ Product Dimension
30AUHT 20AUHT

• HP condenser motor with thermal


25AUHT / 30AUHT
cutoff
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advanced blade design (except
30AUHT) Model A B C D E F G H

• Automatic shutter 20AUHT 200 306 260 302 240 52 90 80


25AUHT 250 356 310 352 290 38 90 63
• Single speed 30AUHT 300 406 360 402 340 38 90 78

KDK Company, Division of PES and Panasonic Ecology Systems


(Thailand) Co., Ltd. certify that the wall mount series models
shown herein are licensed to bear the AMCA Seal. The ratings
shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the AMCA Certified
Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.02 0.04 0.06 FOR AMCA FOR IEC
CFM 356 315 271 227
220V 60Hz Sones 2.3 2.4 1.8 2.8
1343 24.5 22
20AUHT
CFM 338 294 253 171
240V 50Hz 1234 23.5 21.5
Sones 2.1 2.4 2 3.5
CFM 515 421 330 227
220V 60Hz Sones 2.5 2.3 1.9 3
1113 34.3 31
25AUHT
CFM 527 465 400 347
240V 50Hz 1143 35.2 32
Sones 5.8 5.6 5.2 4.8
CFM 586 486 335 174
220V 60Hz 874 40.4 38
Sones 2.2 2.2 4.1 2.4
30AUHT
CFM 624 565 491 312
240V 50Hz 935 41.5 39
Sones 3.7 3.6 3.6 4.1

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a backdraft shutter. The speed (RPM) and Watts
rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field
calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.41
WALL MOUNT VENTILATION FAN
Automatic Shutter Louver Series

20ALH/25ALH/
Product Dimension
30ALF 11

• HP condenser motor with thermal


cutoff
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advanced blade design (except
Model A B C D E F G H 30ALF 11)
20ALH 200 306 260 302 240 68 90 80 • Automatic shutter
25ALH 250 356 310 352 290 63 90 63
30ALF 11 300 406 360 402 340 63 90 78
• Single speed

KDK Company, Division of PES and Panasonic Ecology


Systems Guangdong Co., Ltd. certify that the wall mount
series models shown herein are licensed to bear the
AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.025 0.05 FOR AMCA FOR IEC

CFM 328 280 170


20ALH 220V 60Hz 1385 32.8 28.5
Sones 3.5 3.2 3.4

CFM 420 372 232


25ALH 220V 60Hz 1097 37.5 33.0
Sones 2.7 2.7 4.6

CFM 447 288 154


30ALF 11 220V 60Hz 746 37.1 33.0
Sones 2.0 2.7 2.2

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of an inlet grill and backdraft shutter. The speed
(RPM) and Watts rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a
hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
*the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
**the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.
2.42
WALL MOUNT VENTILATION FAN
Automatic Shutter Louver Series

20ALHT/
25ALHT/ Product Dimension
30ALFT 20ALHT

• HP condenser motor with thermal


25ALHT / 30ALFT
cutoff
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advanced blade design (except
30ALFT) Model A B C D E F G H

• Automatic shutter 20ALHT 200 306 260 302 240 68 90 80


25ALHT 250 356 310 352 290 63 90 63
• Single speed 30ALFT 300 406 360 402 340 63 90 78

KDK Company, Division of PES and Panasonic Ecology


Systems (Thailand) Co., Ltd. certify that the wall mount
series models shown herein are licensed to bear the AMCA
Seal. The ratings shown are based on tests and procedures
performed in accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the requirements of
the AMCA Certified Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.02 0.04 0.06 FOR AMCA FOR IEC
CFM 327 294 256 162
220V 60Hz 2.8 2.7 4.3 5.3
1277 24.2 22
Sones
20ALHT
CFM 300 274 234 141
240V 50Hz Sones 2.6 2.5 3.8 3.8
1228 23.5 21.5

CFM 465 409 350 250


220V 60Hz Sones 3.5 3.2 3 5.4
1116 40 36
25ALHT
CFM 468 418 371 327
240V 50Hz 1152 35.2 32
Sones 5.5 5.9 5 5.2
CFM 503 374 230 119
220V 60Hz 2.6 3 3.1 2.5
833 42 38
Sones
30ALFT
CFM 571 494 406 247
240V 50Hz 921 44.3 40
Sones 3.8 3.7 5.1 3.8

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of an inlet grill and backdraft shutter. The speed
(RPM) and Watts rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a
hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.
2.43
WALL MOUNT VENTILATION FAN
Reversible Series

20RGF/25RGF/
Product Dimension
30RGF

• Reversible
• On-off and reverse operated by pull
cord switch
• HP condenser motor with thermal
cut-off
• Well lubricated bearing for long life
Model A B C D E F G H operation
20RGF 200 306 260 302 240 52 90 80 • Propeller fan incorporated with
25RGF 250 356 310 352 290 38 90 63
30RGF 300 406 360 402 340 38 90 78
advanced blade design (except
30RGF)
• Shutter operated by pull cord

Specification
Voltage Frequency Consumption RPM Air Volume Noise Weight Installation space
Model No. [W] [min -1] [dB(A)] [kg] [mm]
[V] [Hz] [CMH] [CFM]
50 20 1,290 580 341 36
Exhaust
60 25 1,440 650 383 39
20RGF 220 2.2 250 x 250
50 16 1,100 405 238 46
Intake
60 17 1,170 355 209 48
50 29 1,120 945 556 38
Exhaust
60 34 1,145 950 559 39 2.4 300 x 300
25RGF 220
50 20 900 640 377 45
Intake
60 24 995 645 380 44
50 31 990 1,165 686 39
Exhaust
60 33 995 1,150 677 38
30RGF 220 2.8 350 x 350
50 24 905 800 471 43
Intake
60 24 810 745 428 42
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.44
WALL MOUNT VENTILATION FAN
Reversible Series

20RGFT/25RGFT/
Product Dimension
30RGFT
20AUHT

• Reversible
25AUHT / 30AUHT
• On-off and reverse operated by pull
cord switch
• HP condenser motor with thermal
cut-off
• Well lubricated bearing for long life
operation Model A B C D E F G H

• Propeller fan incorporated with 20RGFT 200 306 260 302 240 52 90 80
25RGFT 250 356 310 352 290 38 90 63
advanced blade design (except 30RGFT 300 406 360 402 340 38 90 78
30RGFT)
• Shutter operated by pull cord

Specification
Voltage Frequency Consumption RPM Air VolumeNoise Weight Installation space
Model No. [W] [min -1] [dB(A)] [kg] [mm]
[V] [Hz] [CMH] [CFM]
50 20 1,260 580 341 36
Exhaust
60 24 1,410 630 371 39
20RGFT 220 2.2 250 x 250
50 15 1,150 405 238 46
Intake
60 17 1,140 355 209 46
50 27 1,090 945 556 38
Exhaust
60 31 1,110 950 559 39 2.4 300 x 300
25RGFT 220
50 21 1,010 600 353 45
Intake
60 23 970 560 330 44
50 31 885 1,165 686 39
Exhaust
60 38 800 1,000 589 38
30RGFT 220 2.8 350 x 350
50 24 840 700 412 43
Intake
60 26 810 680 400 42
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.45
WALL MOUNT VENTILATION FAN
Reversible Louver Series

20RLF/25RLF/
Product Dimension
30RLE

• Reversible
• On-off and reverse operated by pull
cord switch
• HP condenser motor with thermal
cutoff
• Well lubricated bearing for long life
Model A B C D E F G H operation
20RLF 200 306 260 302 240 68 90 80 • Propeller fan incorporated with
25RLF 250 356 310 352 290 63 90 63
30RLE 300 406 360 402 340 63 90 78
advanced blade design (except
30RLE)
• Shutter operated by pull cord

Specification
Voltage Frequency Consumption RPM Air Volume Noise Weight Installation space
Model No.
[V] [Hz] [W] [min -1] [CMH] [CFM] [dB(A)] [kg] [mm]

50 20 1,275 546 321 39


Exhaust
60 25 1,290 600 353 43
20RLF 220 2.4 250 x 250
50 17 1,225 385 227 46
Intake
60 17 1,145 340 200 49
50 29 1,060 876 516 41
Exhaust
60 34 1,060 835 491 41 300 x 300
25RLF 220 2.7
50 20 1,020 570 335 45
Intake
60 24 970 573 338 43
50 31 876 990 583 44
Exhaust
60 33 885 945 556 43
30RLE 220 3.1 350 x 350
50 24 850 730 430 43
Intake
60 24 776 690 406 44
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.46
WALL MOUNT VENTILATION FAN
Reversible Louver Series

20RLFT/25RLFT/
Product Dimension
30RLET
20RLFT

• Reversible
25RLFT / 30RLET
• On-off and reverse operated by pull
cord switch
• HP condenser motor with thermal
cutoff
• Well lubricated bearing for long life
operation Model A B C D E F G H

• Propeller fan incorporated with 20RLFT 200 306 260 302 240 68 90 80
25RLFT 250 356 310 352 290 63 90 63
advanced blade design (except 30RLET 300 406 360 402 340 63 90 78
30RLET)
• Shutter operated by pull cord

Specification
Voltage Frequency Consumption RPM Air VolumeNoise Weight Installation space
Model No. [W] [min -1] [dB(A)] [kg] [mm]
[V] [Hz] [CMH] [CFM]
50 20 1,240 548 321 39
Exhaust 60 24 1,290 570 335 43
220 2.4 250 x 250
20RLFT 50 15 1,190 370 218 46
Intake
60 17 1,180 340 200 46
50 29 1,100 840 494 43
Exhaust 60 33 1,100 835 491 43
220 2.7 300 x 300
25RLFT 50 21 1,035 580 341 43
Intake
60 23.5 1,035 560 330 44.5
50 31 890 990 583 44
Exhaust 60 38 880 945 558 43
220 3.1 350 x 350
30RLET 50 25 770 600 353 43
Intake
60 26 770 600 353 44
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.47
WALL MOUNT VENTILATION FAN
Metallic Series

20ASB/20ASB05/
Product Dimension 25ASB/25ASB05/
30ASB/30ASB05

• Condenser motor with thermal cutoff


• Well lubricated bearing for long life
Model A B C D E F
operation
20ASB / 20ASB 05 200 300 312 240 50 90 • High performance propeller fan
25ASB / 25ASB 05 250 350 362 290 45 90 adopted
30ASB/ 30ASB 05 300 400 412 340 45 90
• Automatic shutter
• Powder painted metallic orifice,
KDK Company, Division of PES and Panasonic Ecology Systems
Guangdong Co., Ltd. certify that the wall mount series models blade and oil cup
shown herein are licensed to bear the AMCA Seal. The ratings • Detachable oil cup
shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and AMCA Publication
311 and comply with the requirements of the AMCA Certified
Ratings Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.025 0.05 FOR AMCA FOR IEC
CFM 330 259 183
220V 60Hz 1358 25.5 21.5
Sones 1.7 1.9 3.9
20ASB
CFM 296 198 151
240V 50Hz 1252 22.4 19.5
Sones 1.5 1.7 3.2
CFM 296 198 151
20ASB 05 240V 50Hz 1252 22.4 19.5
Sones 1.5 1.7 3.2
CFM 522 414 240
220V 60Hz 1277 35.5 30.5
25ASB Sones 1.9 1.6 2.2
CFM 486 434 314
240V 50Hz 1194 35.1 29.5
Sones 2.0 2.0 2.4
CFM 486 434 314
25ASB 05 240V 50Hz 1194 35.1 29.5
Sones 2.0 2.0 2.4
CFM 637 400 85
220V 60Hz 1088 39.8 34.5
Sones 2.0 2.7 2.2
30ASB
CFM 706 620 498
240V 50Hz 1175 38.1 34
Sones 2.9 2.3 2.2
CFM 706 620 498
30ASB 05 240V 50Hz 1175 38.1 34
Sones 2.9 2.3 2.2

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a backdraft shutter. The speed (RPM) and Watts
rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field
calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
*the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
**the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.48
WINDOW MOUNT VENTILATION FAN
High Pressure Deluxe Series

15WJA
Product Dimension

• Rain proof and wind resistance


• Condenser motor with thermal cutoff
• Well lubricated bearing for long life
operation
• Highly efficient axial fan adopted
• Electrically operated shutter with
dome shaped hood
• Integral rocker switch for speed
selectable

Performance Data [220V 50Hz/60Hz]

Specification
Air Volume
Model No. Voltage Frequency Consumption RPM Noise Weight Installation Size
[V] [Hz] [W] [min-1] [CMH] [CFM] [dB(A)] [Kg] [mm]

Hi 22 1,878 205 121 46


50
Lo 19 1,325 145 85 36
15WJA 220 2.4 ø 186 - ø 190
Hi 27 2,012 220 129 48
60
Lo 20 1,394 153 90 38
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.

2.49
WINDOW MOUNT VENTILATION FAN
Electric Shutter Series

15WHCT/
Product Dimension
20WHCT

• Electrically Operated Shutter


• Advance design hood structure to
prevent from rain and wind.
• Suitable for thickness of 3mm
to 25mm
• Simple and Easy installation,
no need of any silicon seal or gasket
Model A B C C’ D
15WHCT 224 182 117 111 72
20WHCT 288 243 120 117 74

KDK Company, Division of PES and Panasonic Ecology


Systems (Thailand) Co., Ltd. certify that the window
mount series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.05 0.1 0.15 FOR AMCA FOR IEC
CFM 127 94 63 31
220V 60Hz Sones 3.0 3.6 3.5 3.9
2440 14.6 13
15WHCT
CFM 127 95 68 50
240V 50Hz Sones 2.3 2.7 3.5 2.8
2537 16 15

CFM 250 188 127 78


220V 60Hz 1517 24.4 22
Sones 3 3.9 4.5 4.2
20WHCT
CFM 230 147 103 53
240V 50Hz Sones
1333 23.4 22
2.8 3.8 3.4 4

Performance certified is for installation type A: Free Inlet, Free Outlet. Performance ratings include the effects of inlet grille and shutter. The speed (RPM) and
Watts rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free
field calculated per AMCA International Standard 301. Values shown are for installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.50
WINDOW MOUNT VENTILATION FAN
Automatic Shutter Series

15WAA/15WAAMN/
20WAA/20WAAMN
Product Dimension

• Automatic shutter
Air Direction
• High Performance Condenser motor
with thermo cut-off
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advance blade design.
• Removable blade for easy Air Direction

Model A B C D E F G H (Max)
maintenance
15WAA / 15WAAMN 150 212 100 47 53 38 175 (30)
20WAA / 20WAAMN 206 290 122 76 46 59 237 (36)

KDK Company, Division of PES and Panasonic Ecology


Systems (Thailand) Co., Ltd. certify that the window
mount series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.02 0.04 0.06 FOR AMCA FOR IEC
CFM 124 109 91 79
220V 60Hz 2021 19.6 18
15WAA Sones 3.6 4.5 4.1 4
15WAAMN CFM 124 109 93 78
240V 50Hz 2062 18.2 16
Sones 3.5 4.5 4.1 3.8
CFM 206 147 124 94
220V 60Hz 1385 18.4 17
20WAA Sones 3.7 3.8 3.5 3.3
20WAAMN CFM 165 153 141 131
240V 50Hz Sones
1375 18.6 17.5
3.4 3.3 3.4 3.4
Performance certified is for installation type A: Free Inlet, Free Outlet. Performance ratings include the effects of a shutter. The speed (RPM) and Watts
rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field
calculated per AMCA International Standard 301. Values shown are for installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.51
WINDOW MOUNT VENTILATION FAN
Cord-operated Shutter Series

Product Dimension 15WUD/


20WUD

• HP condenser motor with


thermal cutoff
• Well lubricated bearing for long life
operation
• Propeller fan incorporated with
advanced blade design
Model A B C D E F G H
• Shutter operated by pull cord
15WUD 150 210 97 43 54 37 177 149
20WUD 200 271 98 36 62 36 237 201 • Metallic shutter axis

KDK Company, Division of PES and Panasonic Ecology


Systems (Thailand) Co., Ltd. certify that the window
mount series models shown herein are licensed to bear
the AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with AMCA
Publication 211 and AMCA Publication 311 and comply
with the requirements of the AMCA Certified Ratings
Program.

Specification
CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.01 0.02 0.03 FOR AMCA FOR IEC
CFM 105 94 79 66
220V 60Hz 0.9 0.9 2.2 2.4
1425 9.7 8.9
Sones
15WUD
CFM 124 115 104 94
240V 50Hz Sones 1.4 1.6 1.8 3.7
1722 10.3 9.5

inches of H2O 0 0.02 0.03 0.04


CFM 188 129 112 88
220V 60Hz 0.8 1.2 1.8 1.4
980 19.2 17.9
Sones
20WUD
CFM 221 168 141 118
240V 50Hz 1096 18.5 17.2
Sones 1.8 1.6 2.2 2.0

Performance certified is for installation type A: Free Inlet, Free Outlet. Performance ratings include the effects of a shutter. The speed (RPM) and Watts rating
shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA International Standard 301. Values shown are for installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.52
SPECIFICATIONS

Ceiling Mount Ventilation Fan Model Comparison


CFM/SONE AT STATIC Pressure (ps-inches of H2O)
Model no. Voltage Frequency Speed RPM Watts* Watts**
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.625 0.75 0.875
CFM 41 28 25 - - - - - -
220V 60Hz - 810 11 10
17CUG Sones 0.3 0.5 0.6 - - - - - -
/17CUGA CFM 50 43 40 - - - - - -
240V 50Hz - 780 12 10.5
Sones 0.3 0.4 0.6 - - - - - -
CFM 83 73 68 44 - - - - -
220V 60Hz - 610 16 15.5
Sones 0.5 0.6 0.6 1.4 - - - - -
24CUG
CFM 88 77 75 51 - - - - -
240V 50Hz - 680 15.1 14
Sones 0.7 0.8 0.9 1.6 - - - - -
CFM 101 90 88 64 - - - - -
220V 60Hz - 750 18.2 16.5
Sones 0.7 0.8 0.9 1.5 - - - - -
24CDG
CFM 105 91 86 64 - - - - -
240V 50Hz - 780 18.6 17.5
Sones 0.8 0.9 1.0 1.7 - - - - -
CFM 109 99 96 75 47 - - - -
220V 60Hz - 860 23.6 22
Sones 1.0 1.2 1.2 1.5 2.4 - - - -
24CHG
CFM 116 100 94 72 33 - - - -
240V 50Hz - 890 23.5 22
Sones 1.2 1.3 1.4 1.6 2.1 - - - -
CFM 182 162 156 118 78 37 - - -
220V 60Hz Hi 570 33 33
Sones 1.1 1.2 1.3 1.7 2.2 2.5 - - -
27CHH
CFM 198 179 172 126 78 18 - - -
240V 50Hz Hi 609 37 34
Sones 1.4 1.5 1.6 1.8 2.3 2.5 - - -
CFM 226 202 196 163 127 91 53 - -
220V 60Hz Hi 580 48 48
Sones 1.2 1.3 1.4 1.7 2.2 2.7 3.3 - -
32CDH
CFM 257 236 230 192 147 99 53 - -
240V 50Hz Hi 675 56 50
Sones 1.6 1.7 1.8 1.9 2.5 3.0 3.6 - -
220V 60Hz Hi CFM 344 323 317 290 261 230 197 163 126
38CDG 628 98 98
Sones 3.1 3.2 3.2 3.3 3.6 4.1 4.5 5.7 5.7
38CDG 05 CFM 387 367 362 336 305 259 212 165 108
240V 50Hz Hi 737 118 107
38CDG Sones 4.0 4.1 4.2 4.3 4.4 4.7 5.3 5.7 6.2
CFM 88 88 88 88 63 34 5 - -
220V 60Hz Hi
Sones 0.7 1.0 1.0 1.3 1.7 1.8 3.1 - -
24JRB 853 10 8
CFM 88 88 88 88 63 34 5 - -
240V 50Hz Hi
Sones 0.7 1.0 1.0 1.3 1.7 1.8 3.1 - -
CFM 88 88 88 88 63 34 5 - -
220V 60Hz Hi
Sones 0.6 0.9 1.0 1.4 1.6 1.9 3.2 - -
24JAB 839 10 8
CFM 88 88 88 88 63 34 5 - -
240V 50Hz Hi
Sones 0.6 0.9 1.0 1.4 1.6 1.9 3.2 - -
CFM 55 40 37 20 - - - - -
220V 60Hz - 495 13 12
Sones 0.3 0.7 0.8 1.6 - - - - -
24CMUA
CFM 55 44 41 24 - - - - -
240V 50Hz - 562 14 13
Sones 0.3 0.8 1.0 1.4 - - - - -
CFM 94 85 83 72 54 - - - -
220V 60Hz - 681 25 23
Sones 1.0 1.4 1.5 1.9 2.3 - - - -
24CMHA
CFM 108 98 95 77 44 - - - -
240V 50Hz - 753 27 25
Sones 1.4 1.8 1.9 2.1 2.2 - - - -
CFM 208 184 178 144 108 79 - - -
220V 60Hz - 615 46 43
Sones 1.6 1.7 1.7 2.3 3.2 3.5 - - -
27CMHA
CFM 219 194 188 150 110 70 - - -
240V 50Hz - 669 46 43
Sones 1.9 1.9 2.0 2.4 3.4 3.1 - - -
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft shutter. Speed (RPM) shown is nominal. Performance is
based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are
for installation type B: Free inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

2.53
SPECIFICATIONS

Low Noise Type Cabinet Fan Model Comparison


CFM/SONE AT STATIC Pressure (ps-inches of H2O)
Model no. Voltage Frequency Speed RPM Watts* Watts**
inches of H2O 0 0.1 0.125 0.25 0.375 0.5 0.75 1 1.25 1.5
CFM 114 105 102 87 65 - - - - -
220V 60Hz Hi 1,460 26 23
Sones 1.5 1.4 1.4 1.3 1.4 - - - - -
12NSB
CFM 102 90 86 67 39 - - - - -
240V 50Hz Hi 1,342 27 22
Sones 2.0 1.7 1.6 1.4 1.5 - - - - -
CFM 200 183 177 149 118 83 - - - -
220V 60Hz Hi 1,520 45 42
Sones 2.7 2.5 2.4 2.3 2.2 2.0 - - - -
15NSB
CFM 193 177 172 139 94 20 - - - -
240V 50Hz Hi 1,373 47 37
Sones 3.7 3.4 3.2 2.6 2.5 2.8 - - - -
CFM 274 261 258 241 222 196 137 - - -
220V 60Hz Hi 1,470 80 73
Sones 3.3 3.1 3.0 2.9 2.7 2.6 2.7 - - -
18NSB
CFM 281 263 259 232 200 163 34 - - -
240V 50Hz Hi 1,342 84 68
Sones 4.8 4.4 4.4 3.8 3.4 3.0 2.9 - - -
CFM 417 399 395 373 347 318 237 - - -
220V 60Hz Hi 1,420 128 119
Sones 4.0 3.9 3.9 3.9 3.6 3.5 3.4 - - -
18NFB
CFM 429 406 400 381 344 290 78 - - -
240V 50Hz Hi 1,327 135 104
Sones 5.6 5.4 5.4 5.1 4.6 4.3 4.2 - - -
CFM 469 459 456 444 433 413 354 275 - -
220V 60Hz Hi 1,380 170 159
Sones 4.0 4.0 3.9 3.8 3.9 4.0 4.1 4.2 - -
20NSB
CFM 517 500 495 464 424 382 265 110 - -
240V 50Hz Hi 1,328 175 135
Sones 6.0 5.8 5.8 5.4 5.1 4.8 4.5 4.5 - -
CFM 655 642 640 625 611 597 555 505 440 -
220V 60Hz Hi 1,400 350 310
Sones 6.0 6.0 5.9 5.9 5.7 5.7 5.8 5.8 5.8 -
23NLB
Hi CFM 688 670 664 642 614 579 493 388 199 -
240V 50Hz 1,342 347 260
Sones 8.8 8.6 8.4 8.1 8.0 7.6 7.2 6.7 6.6 -
CFM 940 924 919 899 877 857 790 710 610 502
220V 60Hz Hi 1,380 460 425
Sones 7.1 7.1 7.1 7.0 6.8 6.8 6.7 6.7 6.7 6.9
25NSB
CFM 963 938 935 906 868 822 719 567 395 -
240V 50Hz Hi 1,305 481 370
Sones 10.1 9.8 9.7 9.3 9.2 8.8 8.0 7.5 8.2 -
CFM 1,016 1,000 995 975 954 933 875 803 710 590
220V 60Hz Hi 1,420 680 520
Sones 8.2 8.2 8.2 8.2 7.9 7.9 7.8 7.6 7.5 7.5
25NFB
CFM 1,057 1,048 1,040 1,010 972 922 811 660 473 -
240V 50Hz Hi 1,330 537 430
Sones 12.1 11.9 11.5 11.1 10.6 9.8 8.7 8.7 10.3 -
Performance certified is for installation type D: Ducted inlet, Ducted outlet.
Performance ratings do not include the effects of appurtenances (accessories), Speed (RPM) shown is nominal.
Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5ft (1.5m) in a hemispherical free field calculated
per AMCA International Standard 301.
Values shown are for installation Type D: ducted inlet hemispherical sone levels. Ratings do not include the effect of duct end correction.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

Low Noise Type Cabinet Fan (Three Phase Series) Model Comparison (Non-AMCA Certified)
Voltage Frequency Comsumption RPM Air Volume Noise Weight Duct Size Impeller Diameter
Model No. Phase
[V] [Hz] [W] [min-1] [CMH] [CFM] [dB(A)] [Kg] [mm] [mm]
50 940 1,375 4,000 2,354 43
25SWC 3 380 60 250 x 500 250
60 1,450 1,530 4,500 2,648 45
50 1,180 1,345 5,200 3,060 45
25SMC 3 380 60 250 x 700 250
60 1,750 1,470 5,500 3,237 46
50 600 1,295 2,600 1,530 44
28NXC 3 380 28 ø250 280
60 840 1,380 2,650 1,560 45
Note: The value in Specification table are representative characteristic value at 380V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.
The above Low Noise Type Cabinet Fan (Three Phase Series) Model are not licensed to bear the AMCA Certified Ratings Seal.
2.54
SPECIFICATIONS

Industrial Ventilation Fan Model Comparison


CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model no. Voltage Frequency RPM
inches of 0 0.05 0.075 0.1 0.125 0.25 0.375 0.5 0.75 FOR AMCA FOR IEC
H 2O
CFM 788 742 715 686 647 - - - -
220V 60Hz 1570 61 57
Sones 4.9 4.7 4.5 4.5 4.6 - - - -
25GSE
CFM 701 657 633 600 565 187 - - -
240V 50Hz 1400 48 44
Sones 3.8 3.6 3.6 3.5 3.6 8.6 - - -
CFM 1308 1247 1217 1184 1153 772 - - -
220V 60Hz 1460 129 119
Sones 9.0 9.0 9.1 9.0 9.1 9.4 - - -
30GSE
CFM 1177 1119 1090 1058 1026 561 243 - -
240V 50Hz 1315 106 98
Sones 5.5 5.5 5.6 5.6 5.8 11.1 12.0 - -
CFM 1850 1788 1752 1712 1669 1456 600 - -
220V 60Hz 1640 178 161
Sones 11.9 11.6 12.0 12.4 13.6 14.6 13.4 - -
35GSE
CFM 1615 1548 1506 1458 1411 1147 390 - -
240V 50Hz 1435 130 122
Sones 8.6 8.2 8.2 8.0 8.0 12.6 13.4 - -
CFM 2677 2581 2535 2488 2440 2170 2050 - -
220V 60Hz 1550 294 270
Sones 20.0 20.0 19.7 19.4 19.3 18.9 19.9 - -
40GSE
CFM 2135 2067 2035 2000 1965 1800 1480 - -
240V 50Hz 1440 164 151
Sones 9.0 8.5 8.7 8.7 8.7 13.0 14.2 - -

CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**


Model no. Voltage Frequency RPM
inches of H2O 0 0.2 0.3 0.4 FOR AMCA FOR IEC
CFM 3278 3131 3001 2795
220V 60Hz 1563 346 325
Sones 10 10.4 10.6 10.8
45GSC
CFM 2854 2648 2454 2030
240V 50Hz 1430 277 241
Sones 7.8 7.7 7.8 9.4
CFM 3884 3443 3090 2501
220V 60Hz 1080 347 326
Sones 10.9 11.3 11.5 11.8
50GSC
CFM 3354 2854 2266 912
240V 50Hz 968 293 271
Sones 11.7 13.8 14.5 15.4
CFM 5038 4349 3943 3560
220V 60Hz 1088 384 361
Sones 10.1 9.8 9.5 10.1
60GSC
CFM 4402 3855 3366 2972
240V 50Hz 980 289 263
Sones 10.3 8.6 8.5 11.5
Performance certified is for installation type A: Free Inlet, Free Outlet. 1. For models 25/30/35/40GSC, Speed (RPM) shown is nominal; 2. but for models
45/50/60GSC, the Speed (RPM) and watts rating shown are at the static pressure of 0 inch of H2O. Performance is based on actual speed of test. The sound
ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for
installation type A: Free Inlet hemispherical sone levels.
* the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

Industrial Ventilation Fan Model Comparison (Non-AMCA Certified)


Voltage Frequency Comsumption RPM Air Volume Noise Weight
Model No. Phase
[V] [Hz] [W] [min-1] [CMH] [CFM] [dB(A)] [Kg]
50 220 1,450 5,520 3,249 52 18.5
45GTC 3 380
60 330 1,690 6,420 3,779 58
50 320 1,400 6,960 4,097 54
50GTC 3 380 28.5
60 475 1,590 8,010 4,715 58
50 310 940 9,420 5,544 49
60GTC 3 380 34
60 450 1,070 10,920 6,427 53
50 42 1,185 1,220 718 46
30KQT - 220 4.9
60 51 1,255 1,270 747 47
50 61 1,175 2,060 1,212 49
40KQT - 220 6.4
60 76 1,260 2,190 1,289 51
50 108 920 3,630 2,137 54
50AEQ2 - 220 11.5
60 130 1,050 4,200 2,472 58
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz. RPM data is for reference only. Values may vary subject to different conditions.
The above Industrial Ventilation Fan Model are not licensed to bear the AMCA Certified Ratings Seal.
2.55
SPECIFICATIONS

Wall Mount Ventilation Fan Model Comparison


CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.025 0.05 FOR AMCA FOR IEC
CFM 157 122 65
220V 60Hz 1533 20.6 19.0
Sones 2.5 1.9 2.3
15AAQ1
CFM 154 120 63
240V 50Hz 1453 20.1 19.0
Sones 1.7 1.4 2.1
CFM 355 314 196
20AUH 220V 60Hz 1410 32.4 28.5
Sones 2.5 2.5 1.7
CFM 514 426 290
25AUH 220V 60Hz 1200 37.8 33.0
Sones 1.8 1.5 1.8
CFM 572 453 235
30AUH 11 220V 60Hz 856 37.0 33.0
Sones 1.0 1.7 2.6
CFM 328 280 170
20ALH 220V 60Hz 1385 32.8 28.5
Sones 3.5 3.2 3.4
CFM 420 372 232
25ALH 220V 60Hz 1097 37.5 33.0
Sones 2.7 2.7 4.6
CFM 447 288 154
30ALF 11 220V 60Hz 746 37.1 33.0
Sones 2.0 2.7 2.2
CFM 330 259 183
20ASB 220V 60Hz 1358 25.5 21.5
Sones 1.7 1.9 3.9
20ASB / CFM 296 198 151
240V 50Hz 1252 22.4 19.5
20ASB 05 Sones 1.5 1.7 3.2
CFM 522 414 240
25ASB 220V 60Hz 1277 35.5 30.5
Sones 1.9 1.6 2.2
25ASB / CFM 486 434 314
240V 50Hz 1194 35.1 29.5
25ASB 05 Sones 2.0 2.0 2.4
CFM 637 400 85
30ASB 220V 60Hz 1088 39.8 34.5
Sones 2.0 2.7 2.2
30ASB / CFM 706 620 498
240V 50Hz 1175 38.1 34.0
30ASB 05 Sones 2.9 2.3 2.2

Model Voltage Frequency CFM/SONE AT STATIC Pressure (ps-inches of H2O) RPM Watts* Watts**
inches of H2O 0 0.02 0.04 0.06 For AMCA FOR IEC
CFM 356 315 271 227
220V 60Hz 1343 24.5 22
Sones 2.3 2.4 1.8 2.8
20AUHT
CFM 338 294 253 171
240V 50Hz 1234 23.5 21.5
Sones 2.1 2.4 2 3.5
CFM 515 421 330 227
220V 60Hz 1113 34.3 31
Sones 2.5 2.3 1.9 3
25AUHT CFM 527 465 400 347
240V 50Hz 1143 35.2 32
Sones 5.8 5.6 5.2 4.8
CFM 586 486 335 174
220V 60Hz 874 40.4 38
Sones 2.2 2.2 4.1 2.4
30AUHT CFM 624 565 491 312
240V 50Hz 935 41.5 39
Sones 3.7 3.6 3.6 4.1
CFM 327 294 256 162
220V 60Hz 1277 24.2 22
Sones 2.8 2.7 4.3 5.3
20ALHT CFM 300 274 234 141
240V 50Hz 1228 23.5 21.5
Sones 2.6 2.5 3.8 3.8
CFM 465 409 350 260
220V 60Hz 1116 40 36
Sones 3.5 3.2 3 5.4
25ALHT CFM 468 418 371 327
240V 50Hz 1152 35.2 32
Sones 5.5 5.9 5 5.2
CFM 503 374 230 119
220V 60Hz 833 42 38
Sones 2.6 3 3.1 2.5
30ALFT CFM 571 494 406 247
240V 50Hz 921 44.3 40
Sones 3.8 3.7 5.1 3.8
Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of backdraft shutter for all models and inlet grille for
model 20ALH, 25ALH, 30ALF 11, 20ALHT, 25ALHT, 30ALFT. The speed (RPM) and Watts rating shown are at the static pressure of 0 inch of H2O. The sound ratings
shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown
are for installation type A: Free inlet hemispherical sone levels. *the Watts rating is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
**the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.
2.56
SPECIFICATIONS

Wall Mount Ventilation Fan Model Comparison (Non-AMCA Certified)


Voltage Frequency Comsumption RPM Air Volume Noise Weight Installation space
Model No.
[V] [Hz] [W] [min-1] [CMH] [CFM] [dB(A)] [Kg] [mm]
50 34 1,100 835 491 42
25AUFA 220
60 34 1,080 820 483 42
2.8 300 x 300
50 20 1,290 580 341 36
Exhaust
60 25 1,440 650 383 39
20RGF 220 2.2 250 x 250
Intake 50 16 1,100 405 238 46
60 17 1,170 355 209 48
50 29 1,120 945 556 38
Exhaust
60 34 1,145 950 559 39
25RGF 220 2.4 300 x 300
50 20 900 640 377 45
Intake
60 24 995 645 380 44
Exhaust 50 31 900 1,165 686 39
60 33 995 1,150 677 38
30RGF 220
50 24 905 800 471 43
2.8 350 x 350
Intake
60 24 810 745 428 42
Exhaust 50 20 1,260 580 341 36
60 24 1,410 630 371 39
20RGFT 220 2.2 250 x 250
50 15 1,150 405 238 46
Intake
60 17 1,140 355 209 46
Exhaust 50 27 1,090 945 556 38
60 31 1,110 950 559 39
25RGFT 220 2.4 300 x 300
50 21 1,010 600 353 45
Intake
60 23 970 560 330 44
Exhaust 50 31 885 1,165 686 39
60 38 800 1,000 589 38
30RGFT 220
700 412 43
2.8 350 x 350
50 24 840
Intake
60 26 810 680 400 42
50 20 1,275 546 321 39
Exhaust
60 25 1,290 600 353 43
20RLF 220 2.4 250 x 250
50 17 1,225 385 227 46
Intake
60 17 1,145 340 200 49
50 29 1,060 876 516 41
Exhaust 60 34 835 491 41
1,060
25RLF 220 2.7 300 x 300
50 20 1,020 570 335 45
Intake
60 24 970 573 338 43
50 31 876 990 583 44
Exhaust
60 33 885 945 556 43
30RLE 220 3.1 350 x 350
50 24 850 730 430 43
Intake
60 24 776 690 406 44
50 20 1,240 548 321 39
Exhaust
60 24 1,290 570 335 43
20RLFT 220
50 15 1,190 370 218 46
2.4 250 x 250
Intake
60 17 1,180 340 200 46
50 29 1,110 840 494 43
Exhaust
60 33 1,110 835 491 43
25RLFT 220 2.7 300 x 300
50 21 1,035 580 330 43
Intake
60 23.5 1,035 560 583 44.5
50 31 890 990 583 44
Exhaust
60 38 880 945 558 43
30RLET 220
50 25 770 600 353 43
3.1 350 x 350
Intake
60 26 770 600 353 44
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.
The above Wall Mount Ventilation Fan Model are not licensed to bear the AMCA Certified Ratings Seal.

2.57
SPECIFICATIONS

Window Mount Ventilation Fan Model Comparison


CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**
Model Voltage Frequency RPM
inches of H2O 0 0.05 0.1 0.15 FOR AMCA FOR IEC

CFM 127 94 63 31
220V 60Hz Sones 3.0 3.6 3.5 3.9
2440 14.6 13
15WHCT
CFM 127 95 68 50
240V 50Hz Sones 2.3 2.7 3.5 2.8
2537 16 15

CFM 250 188 127 78


220V 60Hz 1517 24.4 22
Sones 3 3.9 4.5 4.2
20WHCT
CFM 230 147 103 53
240V 50Hz Sones
1333 23.4 22
2.8 3.8 3.4 4

CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**


Model Voltage Frequency RPM
inches of H2O 0 0.02 0.04 0.06 FOR AMCA FOR IEC

CFM 124 109 91 79


220V 60Hz 2021 19.6 18
15WAA Sones 3.6 4.5 4.1 4
15WAAMN CFM 124 109 93 78
240V 50Hz 2062 18.2 16
Sones 3.5 4.5 4.1 3.8
CFM 206 147 124 94
220V 60Hz 1385 18.4 17
20WAA Sones 3.7 3.8 3.5 3.3
20WAAMN CFM 165 153 141 131
240V 50Hz Sones
1375 18.6 17.5
3.4 3.3 3.4 3.4

CFM/SONE AT STATIC Pressure (ps-inches of H2O) Watts* Watts**


Model Voltage Frequency RPM
inches of H2O 0 0.01 0.02 0.03 FOR AMCA FOR IEC

CFM 105 94 79 66
220V 60Hz 0.9 0.9 2.2 2.4
1425 9.7 8.9
Sones
15WUD
CFM 124 115 104 94
240V 50Hz Sones 1.4 1.6 1.8 3.7
1722 10.3 9.5

inches of H2O 0 0.02 0.03 0.04


CFM 188 129 112 88
220V 60Hz 0.8 1.2 1.8 1.4
980 19.2 17.9
Sones
20WUD
CFM 221 168 141 118
240V 50Hz 1096 18.5 17.2
Sones 1.8 1.6 2.2 2.0

Performance certified is for installation type A: Free Inlet, Free Outlet. Performance ratings include the effects of shutter for all models and inlet grille for model
15WHCT and 20WHCT. The speed (RPM) and Watts rating shown are at the static pressure of 0 inch of H2O. The sound ratings shown are loudness values in
fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type A: Free Inlet
hemispherical sone levels.
* the Watts raing is only for AMCA test method and it is at the static pressure of 0 inch of H2O.
** the Watts rating is only for IEC test method and the AMCA Certified Ratings Seal does not apply to IEC test method watts.

Voltage Frequency Comsumption RPM Air Volume Noise Weight Installation Size
Model No. [W] [W] [W] [min-1] [dB(A)] [Kg] [mm]
[CMH] [CFM]
Hi 22 1,878 205 121 46
50
Lo 19 1,325 145 85 36
15WJA 220 2.4 ø186 - ø190
Hi 27 2,012 220 129 48
60
Lo 20 1,294 153 90 38
Note: The value in Specification table are representative characteristic value at 220V, 50/60Hz
RPM data is for reference only. Values may vary subject to different conditions.
The above Window Mount Ventilation Fan Model (15WJA) is not licensed to bear the AMCA Certified Ratings Seal.

2.58
AIR CURTAIN
Cross Flow Type

PRODUCT LINEUP
Remote Controlled Series
Efficient Distance - 3m Efficient Distance - 4m

3009GA (900mm) 4009GA (900mm)


3012GA (1200mm) 4012GA (1200mm) Remote
control
3015GA (1500mm) 4015GA (1500mm)

Sensor Series
3009DA (900mm) 4009DA (900 mm)
3012DA (1200mm) 4012DA (1200 mm)
3015DA (1500mm) 4015DA (1500 mm)

• Cross flow fan adopted for wide and uniform


Standard Series
airflow
3009UA (900mm) 4009UA (900 mm) Door Contact Sensor

• Uniquely auxiliary air enhances airflow output


for Sensor Series
3012UA (1200mm) 4012UA (1200 mm)
3015UA (1500mm) 4015UA (1500 mm)

• Thick air stream provides high inflow


momentum DIMENSION
• Resin with glass fiber adopted for fan blade ■ Front view of standard /sensor series ■ Right view of standard /
sensor series
A
• Simple structure allows easy maintenance
212

• Permanently lubricated ball bearing

231.5
equipped Direction of
Air outlet

• Air deflection plate for airflow direction ■ Front view of remote control series ■ Right view of remote
adjustment A
control series
212

• Main air inlet at top allows neat image

231.5
• Push button switch
Direction of

• 2-speed selection
Air outlet

■ Back view of standard / sensor / remote control series


power cord
B 400 400 B
22

Unit: mm
120 62

3009UA 4009UA 3012UA 4012UA 3015UA 4015UA


170

Model 3009GA 4009GA 3012GA 4012GA 3015GA 4015GA Remote


3009DA 4009DA 3012DA 4012DA 3015DA 4015DA control
250 250 250
A 900 900 1200 1200 1500 1500
B 50 50 200 200 350 350

Voltage Air Volume Consumption Current Outlet Velocity Noise Weight


Model No. Hi Lo [W] [A] [m/s] [dB(A)] [kg]
[V] [Hz] [m3/h] [CFM] [m3/h] [CFM] Hi Lo Hi Lo Hi Lo Hi Lo
3009UA 50 1,100 647 920 541 76 70 0.35 0.32 10.5 8.5 48.5 45
220V
3009GA 60 1,100 647 900 530 92 78 0.42 0.36 10.5 8.5 49.5 45 12.5
3009DA 240V 50 1,150 677 960 565 86 80 0.37 0.35 10.5 9 50.5 47.5
900mm
4009UA 50 1,340 789 1,190 700 110 94 0.50 0.43 12 10 54.5 51
220V
4009GA 60 1,340 789 1,100 647 141 111 0.64 0.51 12 10 55.5 51 13.5
4009DA 240V 50 1,360 800 1,200 706 122 100 0.51 0.43 12.5 10.5 56.5 53.5
3012UA 50 1,400 824 1,270 747 94 85 0.43 0.40 9.5 8 48.5 44.5
220V
3012GA 60 1,400 824 1,250 736 109 94 0.51 0.46 9.5 8 48.5 44.5 15
3012DA 240V 50 1,500 883 1,320 777 107 95 0.46 0.43 10 8.5 50.5 47
1200mm
4012UA 50 1,700 1,001 1,530 901 126 105 0.59 0.49 12 10 52.5 48.5
220V
4012GA 60 1,700 1,001 1,450 853 153 118 0.70 0.55 12 10 52.5 48.5 16
4012DA 240V 50 1,800 1,059 1,580 930 139 110 0.60 0.49 12.5 10.5 54.5 51
3015UA 50 2,000 1,177 1,800 1,059 131 110 0.59 0.50 10.5 9.5 51.5 48
220V
3015GA 60 2,000 1,177 1,750 1,030 150 118 0.68 0.54 10.5 9.5 51.5 48 18.5
3015DA 240V 50 2,100 1,236 1,850 1,089 145 115 0.60 0.50 11 10 53.5 50.5
1500mm
4015UA 50 2,450 1,442 2,000 1,177 177 147 0.81 0.68 13 10 56 52
220V
4015GA 60 2,300 1,354 1,780 1,048 220 160 1.01 0.74 13 9.5 56 52 18.5
4015DA 240V 50 2,500 1,471 2,050 1,207 200 160 0.86 0.68 13.5 10.5 58 54.5

Note: 1. The parameters as shown in above table are mearsured at ambient temperature of 20oC.
2. The noise value is measured 1.5m far from the product at angle of 45o below the air outlet. The air outlet is the maximum value.
3. Because the above-mentioned velocity is measured in test laboratory where it's empty, without air flow and obstacle, after actual installation the velocity may vary depends on different service environment.

2.59
AIR CURTAIN
Sirocco Type

DIMENSION For *ESK Models

900 205

226

50 400 400 50
Short Long
63

120
08ESK 08ELK
250 250 250
10ESK 10ELK
12ESK 12ELK
14ESK 14ELK
DIMENSION For *ELK Models • Sirocco fan adopted for long reach and
narrow diffusion airflow
1200 205
• ABS resin casing provides better
weather resistance
226 • Permanently lubricated ball bearing
equipped
200 200
• Air deflection plate for airflow direction
400 400
adjustment
63 • Air inlet at top allows neat image
120 • Push button switch
• 2-speed selection
250 250 250

Input [Hz] Outlet Velocity [m/s] Air Volume [CMH] Noise [dB(A)]
Length Frequency Weight
Model
[mm] [Hz] High Low High Low High Low High Low High Low [Kg]

50 46 42 0.23 0.21 11.5 10.3 650 580 42 39


08ESK 12
60 57 49 0.28 0.25 12.1 9.9 690 560 43 38
50 72 66 0.31 0.29 12 11.1 750 630 46 42
10ESK 12
60 88 79 0.42 0.33 14.9 10.9 860 600 50 40
900
50 176 155 0.85 0.69 16.9 15.8 1050 960 55 50
12ESK 13
60 202 170 0.94 0.75 16.1 15.3 990 940 54 49
50 257 218 1.14 0.99 21.9 19.1 1340 1168 62 59
14ESK 13
60 312 255 1.43 1.16 21.3 17.7 1303 1083 61 57
50 57 53 0.28 0.27 11.6 10.6 880 800 43 41
08ELK 14
60 74 62 0.36 0.32 12.4 10.5 940 790 45 40
50 96 86 0.4 0.39 13.1 11 1000 830 46 42
10ELK 14
60 116 102 0.53 0.47 15.1 10.5 1150 790 50 41
1200
50 224 200 1.04 0.9 17 15.8 1420 1320 56 51
12ELK 15
60 258 220 1.21 1.04 16.2 15.4 1340 1290 55 50
50 333 290 1.52 1.32 22.5 20.1 1867 1668 63 61
14ELK 15
60 423 339 1.93 1.55 22 18.7 1826 1552 63 59

Note: The values in specification tables are representtive characteristic value at 220V 50Hz/60Hz and the ambient temperature of 200C.
The noise values were measured at an angle of 450 below the air outlet, from a distance of 1.5 meters inside the room. The outlet shows maximum value.

2.60
REFERENCE/PROJECT LIST

Jawharaa Project 519 Villas in ALAIN


Mixed Use Development Residential Villas
SUDAN Energy Recovery Ventilators UAE Window Mount Ventilation Type

OMAN Pearl Muscat Ph1


Mixed Used Development
UAE Buhaleeba 200 Villa Complex
Residential Villas
Ducted Ventilation Products Ducted Ventilation Products

3.1
REFERENCE/PROJECT LIST

Pearl Muscat Ph2- B+G+3 Ajman


Mixed Used Development Commercial
OMAN Ducted Ventilation Products UAE Window mount Ventilation

KSA AL Waseel Housing Project


Local Housing Development for Locals
QATAR 42 Villas in Doha
Residential Villas
DC motor Ducted Ventilation products Window Mount Ventilation

3.2
REFERENCE/PROJECT LIST

Labour Camp Project 125 Apartments


Labor Camps Complex Residential Development
UAE Ceiling fans, Window Mount fans, industrial fans OMAN Ceiling Mount Ventilation Fans

OMAN 252 Apartments


Short Description
QATAR 432 Apartments
Short Description
Cabinet Fans , Wall Mount Louver Cabinet Fans, Wall Mount Louver

3.3
REFERENCE/PROJECT LIST

234 Apartments 220 Villa in Abu Dhabi


Residential Development Residential Development
QATAR Ceiling Mount Ventilation Fans UAE Window & Wall Mount Ventilation Fans

KSA SABIC
Net Zero Energy Green House Model
OMAN G+2 Warehouse & Offices
Commercial/industrial
Cabinet Fans, Wall Mount Louver, Mini Scirocco & Industrial Range Fans
Energy Recovery Ventilators

3.4
CERTIFICATES
PRODUCT CERTIFICATION

To ensure safety, KDK products are designed and manufactured according to either the standards of JIS
(Japan Industrial Standard) or IEC (International Electrotechnical Commission). Test certificates are
awarded by recognized test laboratories that further prove the reliability of our products.

CB Test Certificate
CB Test Certificate is issued to products in
compliance with the applicable requirement of
IEC standard under CB Scheme (Certification
Bodies' Scheme) set by IEC .

Beside the international standard of JIS and IEC, different safety certifications are also acquired to fulfill the
requirement in different countries.
ECAS (UAE)
KUCAS (Kuwait) IEC-CB Cert.
Quatest (Vietnam) (Hong Kong)

ICC (Philippines)

SASO (Saudi Arabia)

NOM (Mexico)

SLSI (Sri Lanka)

PSB (Singapore)

SNI (Indonesia)

IEC (Chile) SONCAP (Nigeria)


SIRIM (Malaysia)

In addition, the performance of KDK products are qualified by external authorities:


1) AMCA Seal (Air Movement and Control Association International Inc.) of The United States for ventilation products
2) Suruhanjaya Tenaga (Energy Commission) of Malaysia for ceiling mount ventilation fans
3) VNEEP (National Energy Efficiency Programme) of Vietnam for electric fans
4) EEL (Energy Efficiency Label) of Hong Kong for dehumidifier
5) Seal of Approval Certificate of Allergy UK (The British Allergy Foundation) for air purifier and air cooler
6) Gulf Technical Regulation (GCC) for the Gulf markets

(1) AMCA Mark, USA (2) Suruhanjaya Tenaga, (3) VNEEP, (4) EEL, 5) Allergy UK , 6) Gulf Technical
4.1 Malaysia Vietnam Hong Kong United Kingdom Regulation (GCC)
NOTES
NOTES
PRODUCT CERTIFICATION
NOTES
KDK Company, Division of PES
4017, Takaki-cho, Kasugai, Aichi, Japan
https://www.kdk-mea.com/ CATALOG NO: K-PQDV01
June 2020

You might also like