0% found this document useful (0 votes)
11 views5 pages

RE 900 Series REV 03 EN - 8 - 10 - 2020

The document details a Microprocessor-based conventional Fire Alarm Control Panel designed for medium to large establishments, featuring a user-friendly touch keypad and accommodating 12 to 128 Initiating Device Circuits (IDCs). It includes various specifications such as CE approval, a 20 x 4 dot matrix LCD display, standby battery backup, and options for network communication. Additionally, it outlines compatible devices and ordering information for different panel configurations.

Uploaded by

danodo6309
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views5 pages

RE 900 Series REV 03 EN - 8 - 10 - 2020

The document details a Microprocessor-based conventional Fire Alarm Control Panel designed for medium to large establishments, featuring a user-friendly touch keypad and accommodating 12 to 128 Initiating Device Circuits (IDCs). It includes various specifications such as CE approval, a 20 x 4 dot matrix LCD display, standby battery backup, and options for network communication. Additionally, it outlines compatible devices and ordering information for different panel configurations.

Uploaded by

danodo6309
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

CONVENTIONAL FIRE ALARM CONTROL PANEL

General
A Microprocessor based conventional Fire Alarm
Control Panel are designed to be used for medium
& Large establishments like Schools, hospitals,
hotels, banks, residential / commercial building,
and small scale industries. The system is user
friendly with includes all standard to ensure ease
for use and high reliability . This panel can
accommodate a range of 12 IDC’s upto 128 IDC’s.
User friendly systems which involves a touch
keypad to program the panel. This can be used as
a standalone or peer to peer network.
Features

Isolate and walk test


- CE Approved and NFPA -72 Standard.
- 20 x 4 dot matrix LCD display.
- Operates on 120 - 220VAC 60 /50 Hz, AC mains
power supply.
- Standby (battery) backup 24 VDC power supply
with built in charger.
- Wide range of operating voltage.
- Touch keypad for user friendly operation.
- Epoxy powder coated finish.
- Class- B, Style B / C Initiating Device Circuit
(IDC).
- All zones accept smoke detectors and normal
open contact devices.
- Class B Notification Appliance Circuits (NAC).
- NAC shall be programmed as AUTO SILENCE /
Silence Inhibit.
- Error free Fire / Fault status in unambiguous
colored LED indication.
- 1000 Event storage with RTC.
- Main, Standby status with audible and visual
indication.
- IDC labelling facility in display.
- Each IDC have dedicated LED for Fire, Fault,
- Potential free contact for fire and fault. - All field wiring circuits are supervised.
- Resettable / Steady 24VDC. Output. - Zone Isolation facility with loop voltage cut
- RS 485 Communication facility. off.
- TCP/IP facility (Optional). - Zones available : 12, 16, 20, 24, 32, 48, 64,96
- MODBUS for Building Management System and 128.
integration (Optional).
- Facility to connect Public Address System
- PC software (optional). (PA) through RS-485 Communication.
- External zone wise sounder/contact via RS - Peer to Peer network facility.
485 (Optional).
- Maximum 16 panels can be connected
to a single network.

1 RE-900 Series / Rev 03-EN / 2020-


2021
Specification
Electrical Specification
Primary Power 120 - 220VAC ± 10%, 60 / 50
Hz.450W
24 VDC (2 X 12V Battery (for AH refer battery
Standby Power
calculation) Quiescent current: 120 mA
Operating temperature: 0 – 49° C / 32 – 120° F
Operating Condition Storage Temperature: 0 – 60° C
Relative Humidity - 93 ± 2% RH (non- condensing) at 32 ±2°
C/90 ±3° F
Charging Voltage: 28.0V, ±
Charging Circuit
2% Charging current: 1.2A
(max)
Wiring style Class B, Style Y
Operating Nominal Voltage 24 VDC Nominal
NACs(Current from 12 Zone
2 Amps (1 A percircuit)
Notification Appliance Upto
Circuit 64 Zone)
NACs(Current above 64 Zone) 4 Amps (1 A percircuit)
Line drop 1.8V
EOL resistor 4K7, ½ watt
DC Output (Resettable / Steady) 24VDC Output ,500mA Max
Quantity 3No’s (12Z - 48Z), 6 No’s (64Z -
128Z)
Type Form C
Relays
Relay contact rating 2A @ 30 VDC, 0.5A @ 125 VAC
Power factor 1.0
Wiring style Class B, Style B/C
Normal operating voltage 14 – 21 VDC
Current 15 – 30 mA
Initiating Device Circuits Short circuit current 45 mA (max)
Loop resistance 100 Ω (max)
EOL Resistor 4K7, ½ watt
Standby current 7 mA (2 mA for detectors)

Mounting Detail
2 RE-900 Series / Rev 03-EN / 2020-
2021
Dimensions
IDC Width(mm) Height(mm) Depth(mm)
12 425 350 120
16 425 350 120
20 500 600 160
24 500 600 160
32 500 600 160
48 600 700 160
64 600 1000 160
96 600 1400 160
128 600 1400 160

Compatible Devices
Models Description
RE-900RP Series Fire Alarm Repeater Panel
RE-316S-2L Conventional Photoelectric Smoke detector with
base.
RE-316H-2L Conventional Heat detector with base.
RE-316SH-2L Conventional Multi sensor detector with base
RE-716 MR Conventional Manual Call Point.
RE- 24 CS Conventional Sounder / Horn.
RE-25SS Conventional Sounder / Horn cum strobe
RE-90MB Modbus Converter
RE-TCP Ethernet Module
RE-716SO UL Listed Conventional Sounder / Horn
RE-716SS UL Listed Conventional Sounder / Horn cum
Strobe
RE-716P1T UL Listed Single Action Manual Pull station
RE-716P1TLP(R) UL Listed Dual Action Manual Pull Station
RE-RI Response Indicator.
RE-364BS Conventional Sounder Base
Models Description
Ordering Information
RE-9012 12 IDC Fire Alarm Control Panel
RE-9016 16 IDC Fire Alarm Control Panel
RE-9020 20 IDC Fire Alarm Control Panel
RE-9024 24 IDC Fire Alarm Control Panel
RE-9032 32 IDC Fire Alarm Control Panel
RE-9048 48 IDC Fire Alarm Control Panel
RE-9064 64 IDC Fire Alarm Control Panel
RE-9096 96 IDC Fire Alarm Control Panel
RE-9128 128 IDC Fire Alarm Control Panel

India
United Kingdom USA
RAVEL ELECTRONICS PVT LTD.,
RAVEL ELECTRONICS LTD., RAVEL AMERICAS INC.,
150A, Electronics Industrial
Unit 11, Chancel Industrial Estate, Newhall 2855 NW 112th Ave ST#2 Miami,
Estate, Perungudi,Chennai –
street, Willenhall WV13 1NX, West Midlands, Doral, Florida 33172, USA.
96, India.
United Kingdom. E-mail: [email protected];
E-mail: [email protected]; Web:
www.ravelfire.com Web: www.ravelfire.co.uk

*Ravel reserve the right to change the specification without prior notice. RE-900 Series / Rev 03-EN / 2020-
2021

You might also like