0% found this document useful (0 votes)
223 views2 pages

Hedtd CL449 100 XX B1

The CANLink® CL-449-100-XX Module is a versatile I/O device available in three configurations: Master I/O, Client I/O, and J1939 Client, featuring 4 outputs and up to 8 inputs. It supports various input types including analog, frequency, and PWM, and operates within a voltage range of 8-32 VDC and temperature range of -40°C to 70°C. The module is designed for flexible programming and diagnostics using HED's tools, ensuring high protection against environmental factors and electrical interference.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
223 views2 pages

Hedtd CL449 100 XX B1

The CANLink® CL-449-100-XX Module is a versatile I/O device available in three configurations: Master I/O, Client I/O, and J1939 Client, featuring 4 outputs and up to 8 inputs. It supports various input types including analog, frequency, and PWM, and operates within a voltage range of 8-32 VDC and temperature range of -40°C to 70°C. The module is designed for flexible programming and diagnostics using HED's tools, ensuring high protection against environmental factors and electrical interference.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CANLink® CL-449-100-XX Module

CL-449-100-11 : CANLink Master I/O


CL-449-100-21 : CANLink Client I/O
CL-449-100-31 : J1939 Client

4 Outputs and up to 8 Inputs (8 total I/O):


 (4) Inputs software configurable as switch to battery, switch to
ground, 12-bit analog, Frequency, PWM or Quadrature Encoder.
o Analog standard range is 0-5.64VDC. Other ranges are
possible, but are set at HED. Contact HED for info.
o Frequency max is 10KHz at 50% duty cycle
 (4) pins software configurable as 2A PWM outputs with estimated
current feedback or switch to battery input
The CL-449 is a solid-state o or 2.5A digital outputs (software configurable as PWM or Digital)
microprocessor based module  Client Harness ID Codes* are set in EEPROM. Default is 0x0F (15)
and member of the HED® o ID can be changed via CAN message (see page 2)
CANLink® multiplexed control  (1) J1939 CAN port
family. Delivered in a potted
enclosure, this unit provides a
flexible I/O count in a compact Specifications
and economical package. Enclosure: Noryl plastic enclosure filled with potting
Mating Connectors: DT06-12SA
The CL-449 is designed for use Deutsch W12S (wedge) – one per connector required
as a multi-purpose stand alone 0462-201-16141 16AWG sockets
unit or as a master controller or 114017 Sealing Plugs – Unused pins are required to be
I/O module in a distributed sealed to maintain module sealing
system. Operating Voltage
8-32 VDC
Range:
The HED® CL-449 can be Operating
-40°C to 70°C
programmed using HED®’s do- Temperature:
it-yourself CANLink® Storage Temperature: -40°C to 85°C
Composer™ programming tool IP Rating: IP67
or directly by HED® engineering, PC Boards: The printed circuit boards are designed for high EMI/RFI
and is designed for use with the protection.
CANLink® Conductor™ software The boards are conformal coated with a silicone coating
for further water/moisture protection.
tool for diagnostics and field
All inputs and outputs are protected against shorts to
troubleshooting. Battery(+) or Battery(-).
100% of the boards are functionally tested before
shipment.
* Harness ID codes are used to identify I/O module
location and function to the master controller.

2120 Constitution Avenue, Hartford WI 53027 USA


Tel: 800 398-2224 Fax: 262 673-9455
e-mail: [email protected] Web: www.hedonline.com
Toll-free technical support: (800) 854-3533
CL-449-100-XX Module
DTF15-12PA
Setting Harness ID in EEPROM:
Pin Function
1. Transmit the following message to change Harness Code.
1 Input #1 STB/STG/VTD(0-5.64VDC)/FREQ/PWM/Encoder(1A)*
a. KK = old harness code
2 Input #2 STB/STG/VTD(0-5.64VDC)/FREQ/PWM/Encoder(1B)* b. HH = new harness code
3 Input #3 STB/STG/VTD(0-5.64VDC)/FREQ/PWM/Encoder(2A)* c. MM = module ID = FB (251)
4 Input #4 STB/STG/VTD(0-5.64VDC)/FREQ/PWM/Encoder(2B)*
00EF0002 00 MM KK 00 84 00 00 HH
5 CAN1-L
6 CAN1-H
7 Input #6 STB / Output #1 DOUT(+)/PWM(+)/ECC/(+)(2.5A) To verify new harness ID has been set:

8 Input #7 STB / Output #2 DOUT(+)/PWM(+)/ECC/(+)(2.5A) 2. Cycle power to module.


9 Input #8 STB / Output #3 DOUT(+)/PWM(+)/ECC/(+)(2.5A)
3. Below message is sent by module on power-up.
10 Input #9 STB / Output #4 DOUT(+)/PWM(+)/ECC/(+)(2.5A)
a. HH = new harness code
11 BAT(-) Module
BAT(+) Module and Outputs 1-4 / 00EF0001 -- -- -- HH -- -- -- --
12
Input #5 Battery Voltage VTD (0-32.78VDC)

Note: Above pinout is for HED modules with part number formats of CL-449-100-XX. J1939 Client:
Additional part number data sheets available on HED® website.
1. Default Node ID is: 0x80
* Note: Early versions of Composer™ require input to be configured as Pulse Counter 2. Reference HED J9193 Document for CAN
when using Encoder input feature. If Composer does not show Encoder as available message used to change Node ID.
option to configure input, select one of Encoder pins to be Pulse Counter and this will
configure two paired inputs as Encoder. Second pin does not need to be configured
as anything, but can be configured as FREQ if application also requires the frequency
of the Encoder. Both A & B signals from Encoder are required to be connected to
pins 1A and 1B.

Information contained on this sheet is accurate at the time of 2120 Constitution Avenue, Hartford WI 53027 USA
printing. HED, Inc. reserves the right to change specifications Tel: 800 398-2224 Fax: 262 673-9455
without notice. e-mail: [email protected] Web: www.hedonline.com
© 2018 HED, Inc. TD-CL449-100-XX-B1

You might also like