GEC - Inverse Time Undervoltage Relay

The VDG13 undervoltage relay is designed to protect induction motors from voltage restoration after a loss of supply or severe dip, featuring adjustable time/voltage characteristics. It operates within specific voltage settings and includes auxiliary units for operation indicators. The relay is housed in a durable case suitable for various environmental conditions and is available in multiple voltage ratings.

Uploaded by

Paulo H Tavares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views2 pages

GEC - Inverse Time Undervoltage Relay

The VDG13 undervoltage relay is designed to protect induction motors from voltage restoration after a loss of supply or severe dip, featuring adjustable time/voltage characteristics. It operates within specific voltage settings and includes auxiliary units for operation indicators. The relay is housed in a durable case suitable for various environmental conditions and is available in multiple voltage ratings.

Uploaded by

Paulo H Tavares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

VDG13

lID Measurements I

Type VDG13
The type VDG13 llndervoltage relay is a frequency
compensated induction disc unit with an adjustable
inverse time/Voltage characteristic. Applications include
the protection of induct'lon motors against restoration of
voltage on loss of supply or severe voltage dip.
Overload or temperature rels'{s will usuallv prevent a
motor f;-om running on sustained undervoltage as this
condition generally causes QV6rCurrent. Undervoltage
protectIOn must be applied to a fan motor however,
because the load drops sharply with speed and prevents
the motor current from increasing.
Taps on the operatmg coil and a series resistance are
connected to a link. board and provide a constant induc~
tance/resistance ratio for frequency compensation on
each voltage setting.
Adjustment of the time setting is made by rotating a
knurled moulded disc against a graduated time multiplier
scale.
The disc unit contact is <;Iosed when the operating coil is
de- energiSed.

VOLTAGE SETTINGS
50-90% of 110 volts s.c. adjustable in five equal steps or BURDENS
30-90% of 110 volts a.c. in seven equal steps (with
externally mounted resistor) at 50 or 60 cis. At voltage setting: 5VA
An external voltage transformer can be supplied to enable At norma! voltage:
operation on 230/250 or 440/480 volts a.c.
I
30-90% version
.. - ­ .......... ..
Resetting Voltage '"--.~ """~

I;~! I 1-
50-90% version
.
105% of voltage setting
Re.ay sell:ng (%) ·0 50 60 -r 70 'T SO 90
VA at no'tIlal vOltage 50 : 31 20 : 14 : '05 : B 6
'--- ....
TIME SETTINGS
0···5 seconds at lero voltage (see characteristic) FREQUENCY ERRORS
The maximum pickup variation between 40 Bnd 70 cis
Resett,ng Times. is 7%,
If the voltage reduction is sustained long enough to cause the
rokay to operate, on restoration to rated vatls and with the time
multiplier set at 1.0, resetting times are: AUXILIARY UNITS AND
OPERATION INDICATORS
Relay sctling (%) : 30 .1 40 i 50 1 60 ,70 80 I 90 An auxiliary attracted armature with a hand reset operation
indicator for either shunt reinforcing or series soal in is
Reselling time (sec(lnds) i-···'····IHI~,:-4-'--10T12
ritted as standard.
A--_______________ ,

B---t---c=-
STANDARD COIL RATINGS
Voltage operated (shunt} auxiliary units: 30, 50, 110,
125,220 or 250 volts d.c. at a nominal burden of 3 watts
continuously,

c--~~r-------~--
lhe series seal in Uriit has two current taps. Standard
ratings are as follows:

V.T, MiOimum 0p6r31'l'9


cunen! (amps)

ALA>J:t-1 TRIP eeT

Other coil ratings mo ava,"able wl'th both typos of auxiliary


unit.

Contacts
..,.. IS
Two electrically separate normally open self or
hand reset contaos are fitted, rated to make and carry
r------­ 7500 VA for 0-5 second with maxima of 30 amps Jnd
660 volts a,c, or d.c,
I

AUK CASES
UNiT
The relays are supplied in a size 1 drawout case available
for f!ush or projecting mounting, finished phenolic black
Relays for use in exceptionally severe environments
can be finished to B.S. 2011 ; 20/50/56 at extra cost;
standard relays are finished to B.S. 2011 20/40/4
OPERAT!:'\lG and are satisfactory for normat tropical use.
corL

Maximum Overall DimenSIOns


IL --......... __ ._-­

-i--'
DISC UNIT
I
-------- ---
inS.
Height

! mm ins.
Width

mm in,­
Dep.fh"

mm
Typical application iJnd internal circuit diagram .

Relay Cllse 9--'0 233 I 6,* • 170 11 197

F:<lNnal
resistor 3';'­ .7 I 7ft 198 2,,, 58

[;(lernal ,
transformer 4/ 121 31 92 95
!
• of 2BA terminal S!uds.
"Add 3-' (76 rom) for maxImum ionglh

. I· r -.., .,.. I· --+-++-1


.t ---~I~"'" INFORMATION REQUIRED WITH ORDER
<:)

~-:-?H~~~;~.
?; SLPP~y frequ?:lcy
«
~ 10
Lj : Voltage sett:ng
"­ 1;~I .. ,,,,r.-: , E.derna! transformer ~equirements
Trip circuit (shunt relntorcing or series sea! in}
o 5 . : 11 j- .... :-~-~--~--~--- ,t ! I
Trip circuit current (series seal tn)
o I'!i I ~t :-:---1 :- t-++-;-j
Trip circuit voltage (shunt reinforcing)
100 9() 80 70 60 SO 40 30 20 10 0
Auxiliary contacts (hand or self reset)
PER CENT OF CLOSI><G VOL:AGE
Operation indicator lnsGrlpt:on :f required
Time/vo/tage characteristic. Time multiplier selting= 1-0 Case finish and mode of IT'ountlng

Our policy is One of continuous product development and the right is reserved to supply equipment which may vary slightly from that describe{t

GEe Measurements The General Electric Company Limited of England


51. Leonards Works Stafford ST17 4LX England
Telephone: 07853251 Telex: 36240 Cables: Measurements Stafford Telex

Publication R-5113B
028040 GSP Printed in England

You might also like