Catálogo - Notifier Completo
Catálogo - Notifier Completo
Technology
informationguide2019
SPARE PARTS 50
GENERIC 50
POWER SUPPLIES 50
NFS 2-8 SERIES FACP 50
IFS-2600 SERIES FACP 50
CFP-16 SERIES FACP 50
PRINTER EQUIPMENT 50
AM-1010/AFP-2020 SERIES 50
AFP-3030 SERIES PANEL 51
AFP-2800 SERIES FACP 51
SOLO TEST EQUIPMENT 52
I-2000 EWIS 52
VESDA 53
OSID 54
to use and powerful detection and control system CFP-16/900-8Z-PS5NZ 8 zones fitted with NPS-5 in CAB900
for all conventional detection applications.
CFP-16/650-8Z-PS11NZ 8 zones fitted with NPS-11 in CAB650
The standard panel is equipped with 8 zones but CFP-16/900-8Z-PS11NZ 8 zones fitted with NPS-11 in CAB900
may be extended to 16 Zones by the addition of
an 8 Zone expansion module.
• Simple to install FSKIT650NZ NZ Acrylic (FS) kit, includes Annunciator Plates CAB650
• Expandable to 16 x conventional FSKIT900NZ NZ Acrylic (FS) kit, includes Annunciator Plates CAB900
zones
• 24 character programmable zone descriptor RSMSK650 CAB650 Rear Service Mimic Surrounod Kit
• Compatible with System Sensor devices RSMSK900 CAB650 Rear Service Mimic Surrounod Kit
• Space for up to 33AH batteries
• IP30 rated for CAB650 / CAB 900
NOTE: Contact your Notifier systems consultant for pricing of alternate configurations
detection with 1 zone of agent release. 8 zones fitted with NPS-5, 1 x Agent Release zone in CAB900
CFP-16/900F-LCS2
with LCS fitted to outer door
• CAB650 and CAB900 versions available 8 zones fitted with NPS-5, 1 x Agent Release zone in CAB650
CFP-16/650F-LCS3
• Versions available with LCS fitted to with LCS fitted to outer door and DA30 OWS
outer door. 8 zones fitted with NPS-5, 1 x Agent Release zone in CAB900
• Space for up to 33AH batteries CFP-16/900F-LCS4
with LCS fitted to outer door and DA30 OWS
• IP30 rated for CAB650 / CAB 900
Zone Index Kits
Cabinet Dimensions:
- CAB650 – 650mm H x 450mm W x 190mm D
Part # Description
- CAB900 – 900mm H x 450mm W x 190mm D FSKIT650NZ NZ Acrylic (FS) kit, include Annunciator Plates CAB650
FSKIT900NZ NZ Acrylic (FS) kit, include Annunciator Plates CAB900
FPA Equipment Listing #: NI/102 RSMSK650 CAB650 Rear Service Mimic Surround Kit
RSMSK900 CAB900 Rear Service Mimic Surround Kit
The SGD (signal generating device) provides the SGDIF16 SGD interface to suit CFP- 16NZ
interface to the NZ alarm monitoring services SFDMK16 SGD Inner Door Mounting KitI
Accessories
Part # Description
ACM-ZM8 Remote LED mimic annunciator for up to 8 zones with status LED’s
ACM-8RA Relay module to provide up to 8 C/NO/NC relay contacts
ZLKT16 Annunciator name plate for zone & custom labelling
NOTE: Contact your Notifier systems consultant for pricing of alternate configurations
Strobe/Sounder Interface
Part # Description
• 5A reversible output for use with dual strobes IFS-993F Monitored Strobe/Sounder Interface
• Comes with subplate to fit into standard CHS-xL slot
AFP-3030 ANNUNCIATORS
FPA Equipment Listing #: NI/630 See Page 46 for Annunciator mounting enclosures
• On-Line/Power LED
• Local piezo sounder with a Silence switch
for audible indication of alarm and trouble
conditions
• Slide-out zone text label
options
• 312.5K baud transmission rate
• Dual port for network redundancy
• Mounts on PSI or fits into CHS-xL chassis
• Supports network of up to 200 nodes HS-NCM-MF High Speed Noti·Fire·Net Module – MMOF
• Wire, multi and single mode fibre options inc HS-NCM-SF High Speed Noti·Fire·Net Module – SMOF
hybrid cards HS-NCM-WMF High Speed Noti·Fire·Net Module – Wire / MMOF
• Up to 100mb baud transmission rate
HS-NCM-WSF High Speed Noti·Fire·Net Module – Wire / SMOF
• 1 x HS-NCM can support 2 nodes
HS-NCM-MFSF High Speed Noti·Fire·Net Module – MMOF / SMOF
• Can be used as a repeater
• Mounts on PSI or fits into CHS-xL chassis
ONYXWorks™
Powerful, versatile platform for life safety management
ONYXWorks is the next generation in life safety management for centralized control and monitoring of the fire alarm
system. The intuitive, graphical display allows personnel to rapidly pinpoint, investigate, and respond to alarm events
with minimal operator training. Versatile enough for single-site, multi-site and even worldwide applications, the
ONYXWorks graphical workstation allows end-users to manage their NOTIFIER life safety system over a proprietary
network or Ethernet.
Through its intelligent gateway architecture, ONYXWorks can easily meet the needs of expanding systems. ONYXWorks is also an
ideal retrofit solution. Additionally, ONYXWorks provides mass notification capabilities through IP-based voice paging and LED sign
integration.
Workstation
Description
OnyxWorks™ Workstation & map development
Software Licensing
Part # Description
OnyxWorks™ Workstation Basic Licence, includes email and Netlogic
OW-LIC-BASIC
(requires map development)
OW-LIC-NOTIFY-IP Workstation licence upgrade
Part # Description
NFN-GW-PC-W PC based NFN gateway, Wire
NFN-GW-PC-F PC based NFN gateway, MMOF
ONYX FIRSTVISION™
• Monitors up to 4 nodes
• Uses ModBus over IP
• Requires network control module
• Utilizes TCP/IP
• Requires network control module
VESDAnet Gateway
Part # Description
The VESDA Gateway provides a communication VESDA-HLI-GW VesdaNet gateway
link between the NOTI•FIRE•NET™ network
and the Xtralis™ VESDAnet network.
• Utilizes TCP/IP
• Requires network control module
• Supports up to 100 detectors
CONVENTIONAL DETECTORS
temperature (90°C) Conventional thermal detector, fixed temp 63deg, system sensor, requires
5151AUS
• Uses universal B401 plug in base B401AUS - off white, Type B
• Magnetic test feature Conventional thermal detector, rate of rise, 90deg, system sensor, requires
5151HRAUS
• Dual LED’s for 360° visibility B401AUS - off white, Type C
• 12/24VDC operation Conventional thermal detector, fixed temp 90deg, system sensor, requires
5151HAUS
B401AUS - off white, Type D
FPA Equipment Listing#: NI/221, NI/219, NI/222, NI/220
Part # Description
FPA Equipment Listing #: NI/326, 328, 327
DST-1.5 Sampling tube to suit duct 0.3m to 0.6m
DST-3 Sampling tube to suit duct 0.5m to 1.2m
DST-5 Sampling tube to suit duct 1.2m to 2.4m
DST-10 Sampling tube to suit duct 2.4m to 3.7m
ETX Duct detector exhaust tube
• 10-100m range >70m requires BEAMMK BEAM1224S Beam detector with built in test station
• 4-wire 12/24VDC operation
• Ceiling or wall mount Accessories
• In-built alignment tool Part # Description
• Automatic gain control
BEAMSMK Surface Mount Kit for BEAM 1224, for flat surfaces only
• Remote test station available
BEAMLRK BEAMSMK Surface mount kit Long range kit (70-100m)
• BEAM1224S includes built-in test station
Multi mount kit - For use when mounting beam detector on ceiling or on an
FPA Equipment Listing #: NI/311, 312 BEAMMK
angle.
RTS451KEY Remote test station with key lock to reset beam detector
Part # Description
Conventional Indoor MCP
MCPCNZ NZ conventional MCP Indoor Red, flexible element, with clear flap
This MCP is highly reliable with an aesthetically pleasing,
compact, low-profile design.
Accessories
• Flexibal non- frangible element
Part # Description
FPA Equipment Listing#: NI/601 NZMCPOS Polycarbonate MCP operation sign
NZFE1612 Flexible MCP element with Notifier Logo
PS200FLAP Replacement Clear flap cover for MCP
SC070 Spare test key (pk10)
PS059 Breakable seal for hinged cover (pk5)
Conventional Outdoor MCP NZTB017 Surface mount bezel and adaptable plate for NZ back box
Part # Description
SG-1x10 Spare MCP glass (pk 10) common to all MCP’s
Clear replacement flap to cover MCP from accidental
PS200FLAP
breakage - curved shape
PS210 Flexible MCP element to suit KAC MCP’s
SC070 Spare test key (pk 10) SC070
Accessories
Part # Description
SG-1x10 Spare MCP glass (pk 10)
Clear replacement flap to cover MCP from accidental
PS200FLAP
breakage - curved shape
PS210 Flexible MCP element
SC070 Spare test key (pk 10)
• Multiple colour options for variety of functions Green Double pole indoor call point for Emergency door release, with flexible
MCP4A-GSF
• With Glass or Flexible (non-glass) element element
available Green Double pole indoor call point for Emergency door release, with glass
MCP4A-GSG
element
WCP4A-GSG Green Double pole outdoor call point IP67, with glass element
WCP4A-RSG Red Double pole outdoor call point IP67, with glass elemen
• Dual Bi-colour LED indication FSP-851AUS/BCK FlashScan Photo-optical Smoke Sensor - black
• Flat chamber design to reduce false alarms
• Adjustable from 1.64% to 7.71%/m
obscuration
• Fine protective mesh to prevent insect entry
DETECTOR ACCESSORIES
• Colour coded terminal B501AUS-W Universal addressable detector base, pure white
• Tamper proof lock B501AUS-BK Universal addressable detector base, black
• Multiple hole centres
Accessories
Part # Description
SMK-400 Surface mount box for off-white detector base
WB-1AP-IV Wet base shroud for analogue and conventional detectors 200 Series
Ionization and Heat detectors. W-200B/1 Detector cover - Pure White to suit 800 series and 2151BAUS
• Replaceable plug-in sensor head (not included) Weatherproof duct detector housing for intelligent detector, requires detector
DNRW
• Backward compatible with Innovair models and sampling tube
• Indoor and Weatherproof (IP66) options
Accessories
NOTE: Requires separate intelligent detector and Part # Description
sampling tube
DST1.5 Sampling tube to suit duct 0.3m to 0.6m
REMOTE INDICATORS
addressable relay outputs or notification FRM-1 Single intelligent relay output module.
appliance circuits
Accessories
FPA Equipment Listing #: NI615, 614
Part # Description
SMB-500 Surface mount box to suit 500 series modules
• Switch input or conventional zone versions FMM-1 Single switch input module
available. FZM-1 Single conventional zone interface module Requires external 24VDC
Part # Description
SMB-500 Surface mount box to suit 500 series modules
ZCM Conventional Zone Conversion Module for FZM-1 and XP6-MA
circuits. Accessories
Part # Description
M200E-DIN DIN rail mount clip
M200E-PMB Panel mounting clip
M200E-SMB-KO Surface mount box with knockouts
FPA Equipment Listing #: NI/627 PS200FLAP FG-18-026 Replacement Clear flap cover for MCP
SC070 FG-18-023 Spare test key (pk10)
PS059 FG-18-024 Breakable seal for hinged cover (pk5)
Surface mount bezel and adaptable plate for NZ
NZTB017 FG-18-025
back box
STI-3150 FG-72-016 Weather stopper, clear polycarbonate enclosure
Accessories
Part # Description
B501AP-IV Plug in base for NFX series
BRR Deep base. Red
BDD Deep base. Off-white
WRR Waterproof base. Red
WDD Waterproof base. Off- white
Accessories
Part # Description
B501AP-IV Plug in base for NFX series
BRR Deep base. Red
BDD Deep base. Off-white
WRR Waterproof base. Red
WDD Waterproof base. Off- white
IBS-LID/DW Lid to suit sounder base (pk10)
The Notifier I-2000 Emergency Warning and Intercommunication System (EWIS) has been designed to facilitate the orderly
and speedy evacuation of a building in the event of an emergency. This procedure may be initiated automatically by a fire
alarm system or manually by a break glass call point.
The I-2000 may be used as a fully automated system or it will allow Fire Wardens to easily control and coordinate an
evacuation using the dedicated emergency telephone network.
As these systems are available in any size or configuration, pricing is dependent on the particular design.
• Separate speaker for call tone WIP Handset to suit I-2000 EWIS panel
Surface mount outdoor enclosure in red WIP-BOX-IP66 Weather proof (IP66) surface mount enclosure
Cabinet Dimensions:
- 300mm H x 200m W x 150mm D
Stand alone occupant warning system DA-60CAB Stand alone 60W occupant warning system with NPS-11 in CAB650
including power supply and battery charger DA-120CAB Stand alone 120W occupant warning system with NPS-11 in CAB650
in metal enclosure.
• Digital pre-recorded speech messages FPA Equipment Listing #: NI/409, 410, 411
• Chime, Lock-down, False alarm and Test
messages
• Ability to synchronize multiple amplifiers
• Includes DA series BOWS and power supply
indications and controls
Cabinet Dimensions:
- CAB650 - 650mm H x 450mm W x 190mm D
• Chime, Lock-down, False alarm and Test DA-60 60 Watt building occupant warning system
messages DA-120 120 Watt building occupant warning system
• Ability to synchronize multiple amplifiers
• Mounts onto CHS-1L chassis Accessories
Part # Description
CMM-2 CMM-2 – Custom message module (2 x messages)
amplifiers with manual control and PA DA-DISP/B– DA Series control and microphone
DA-DISPB
functionality. to suit CAB650/CAB900 cabinets
DA-DISP/C – DA Series control module
DA-DISPC
• Designed to be installed in standard to suit 18u/28u/40u cabinets
annunciator slots. DA-DISP/D – DA series PA selector for up to 4 zones
DA-DISPD
Requires a DA-DISP/C for each zone control
CEILING SPEAKERS
• SPL: 90dB 1W @ 1m
• Ceiling cut-out: 140mm ø
Accessories
Part # Description
L-SMB-W Surface mount box to suit 4” speaker, White Ø 280mm, depth 75mm
• SPL: 90dB 1W @ 1m
Accessories
• Ceiling cut-out: 140mm ø
Part # Description
L-SMB-BK Surface mount box to suit 4” speaker, Black dia. Ø 280mm, depth 75mm
HORN SPEAKERS
• SPL: 106dB 1W @ 1m
• Suitable for outdoor (IP66)
Part # Description
Ceiling Loudspeakers
4”Ceiling Loudspeaker, 6/3/1.5/0.75/0.375W White
L-VCP06D-W
• Excellent sound reproduction White plastic dome, AS ISO7240. 24: 2015, with capacitor
• Robust plastic/metal dome 4” Ceiling Loudspeaker, 6/3/1.5/0.75/0.375W Black
L-VCP06D-BK
• AS ISO 7240-24 Certified Type A Speaker / IP21C Black plastic dome, AS ISO7240. 24: 2015, with capacitor
• Available with or without capacitor (part 5” Ceiling loudspeaker, 6/3/1.5W White
L-VCP06A/ENC
number without “C”) White plastic dome, AS ISO 7240.24:2015, with capacitor
6.5” Metal ceiling loudspeaker, 6/3/1.5/0.75W White
L-VCM6A/ENC
Red dome, AS ISO 7240.24:2015, with capacitor
Accessories
Part # Description
L-SMB-W Surface mount box to suit 4” speaker White, Ø 280mm, depth 75mm.
L-SMB-BK Surface mount box to suit 4” speaker Black, Ø 280mm, depth 75mm.
Horn Loudspeakers
Part # Description
• Intelligible voice and superior sound reproduction
• Low-profile design blends easily into any Outdoor horn, 15/10/5W, 8ohm, Grey, ABS, AS ISO 7240.24:2015, with
L-VHP15A/EN
outdoor applications capacitor
• Ergonomic and stylish design
• High-strength UV protective UL94V0 ABS housing
• AS ISO 7240-24 Certified Type B Speaker / IP33C
certified (IP 66 compliant)
Column Loudspeakers
Part # Description
• Intelligible voice and superior sound reproduction Outdoor column speaker, 20/10/5/2.5W, White, Aluminum, AS ISO
L-VOM20A/ENC
• Robust aluminum housing 7240.24:2015, with capacitor
• Supplied with universal swivel bracket for Outdoor column speaker, 40/20/10/5W, White, Aluminum, AS ISO
easy angle adjustment L-VOM40A/ENC
7240.24:2015, with capacitor
• Able to be switched between 100V and 70V
• Adapts to extreme environmentw
• AS ISO 7240-24 Certified Type B Speaker / IP33C
certified (IP65 compliant)
• Available with or without capacitor
(part number without “C”)
INSTALLATION TOOLS
installation of suit the Notifier ceiling speakers. HOLESAW-125 165mm Hole saw to suit 5” speakers
ARBOR A6 Arbor to suit hole saw
NOTIFICATION APPLIANCES
• Synchronized sound
• EN54-3 approved
• 10V-60VDC input SOLEX10B Solex Strobe 10Cd - Blue Shallow Base (10-60vdc)
• IP54 with shallow base, IP65 Deep base SOLEX10G Solex Strobe 10Cd - Green Shallow Base (10-60vdc)
• 80mA alarm current SOLEX10R Solex Strobe 10Cd - Red Shallow Base (10-60vdc)
Accessories
Part # Description
SOLEX-WDBR Deep conduit base to suit Roshni/Solex - Red
SOLEX-WDBW Deep conduit base to suit Flashni/Solex - White
preliminary snap-in feature to hold the SRHK-P Red outdoor strobe, IP66, with clear lens High Candela, Plain/ no label
product in place for the screw attachment
• 7 field-selectable candela settings 15, 30,
75, 95, 110, 135, 185 for wall and ceiling
mount devices.
• Rotary switches to select horn tone and
volume settings. Compatible with 12- or
24-volt systems.
• L-Series horn strobes are listed to UL 1971
and UL 464 for public mode evacuation.
Certified to IEC:-
- II 2G Ex d-IIB T4 Ta. -50oC to +70oC
- II 2G Ex d-IIC T4 Ta. -50oC to +55oC
- II2D Ex tD A21 IP67 T115 **
- Zones 1,2, 21 and 22
Certified to IEC:-
- II 1G Ex ia-IIC T4 Ga. -40oC < Ta < +60oC
- Zone 0
Certified to IEC:-
- II 1G Ex ia-IIC T4 Ga. -40oC < Ta < +60oC
- Zone 0
Certified to IEC:-
- II 1G Ex ia-IIC T4 Ga. -40oC < Ta < +60oC
- Zone 0
- Zone 0
FIRE BELLS
Part # Description
SSM Series Fire Bells
SSM24-6 6” (150mm) Alarm bell – 24VDC
SSM series alarm bells are low current, high SSM24-8 8” (200mm) Alarm bell – 24VDC
decibel notification appliances for use in fire or SSM12-6 6” (150mm) Alarm bell – 12VDC
other signaling applications.
Accessories
• High dB output
Part # Description
• Suitable for indoor and outdoor use
• Low current draw WBB Back Box to suit Bells –Red
• IP66 outdoor rating WS-FIRE Warning Sign - “FIRE” 150mm x 60mm, red on white
• Integrated piezo sounder WS-FIP Warning Sign - “FIRE INDICATOR PANEL”, red on white
• High brightness amber LED illumination WS-000 Warning Sign - “Dial 000, Local Fire Alarm Only”, red on white, 80 x 25mm
• System Inoperative faceplate for use with
Warning Sign - “WARNING - FIRE DOOR CLOSING”,
agent release systems WS-WFDC
non-illuminating, 730mm(w) x 200mm(h)
• Black sign coloured text
Part # Description
Certified to IEC:-
SG-1X10 Spare MCP glass (pk 10), common to all MCP’s
- Ex ia-IIB T4 Ga (-30oC ≤ Ta ≤ +40oC)
Clear replacements flap to cover MCP from accidental breakage suits all
- Zones 0, and 20 PS200FLAP
KAC MCP’s - curved shape
PS210 Flexible MCP element
SC070 Spare test key (pk 10), to suit all MCPs
Part # Description
MDHW15 Wall mount extension bracket 15cm
• Spark suppression MDH400/30 Wall or Floor mount magnetic door holder 400N (41kg) with
MDH400/30
• Reverse polarity diode fitted 30cm arm
Accessories
Part # Description
SZ2575 Surface mount box for MDH400/15 or MDH400/30
FLAME DETECTORS
oxygen deficiency and toxic gasses may pose a SPXCDASMFX XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry
hazard to working environments. XCD is designed
for a broad spectrum of industrial applications XCD CH4(Methane) IR, 0-100%LEL (20,0 to 100.0%LEL) with LM25
SPXCDALMRX
with a comprehensive choice of features and Aluminium Alloy, M20 Entry
benefits in a cost effective package.
SPXCDASMRX XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL) with SS316, M20 Entry
• AS3786 approved
SPXCDALMO1 XCD Oxygen, 25.0%/Vol with Aluminium Alloy, M20 Entry
• Includes field replaceable sensor
• Built in sounder
SPXCDASMO1 XCD Oxygen 25.0%/Vol with SS316, M20 Entry
• N/A and N/C Alarm contacts
• Interconnect up to 24 units XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with LM25 luminium
SPXCDALMHX
Alloy, M20 Entry
Certified to IEC:-
- II 2G Ex d-IIC t SPXCDASMHX XCD Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm) with SS316, M20 Entry
- Ex d IIC T4 Gb. T6(Ta -40oC to +65oC) XCD Carbon Monoxide 0-500ppm (100 to 1000ppm) with Aluminium Alloy,
- Ex tb IIIC T85oC Db IP66 SPXCDALMCX
M20 Entry
Certified to ATEX:- SPXCDASMCX XCD Carbon Monoxide 0-500ppm (100 to 1000ppm) with SS316y, M20 Entry
- Ex d IIC T4 GD T6(Ta -40oC to +65oC)
XCD Hydrogen0-1000ppm with Aluminium Alloy,
- Ex tb IIIC T85oC Db IP66 SPXCDALMG1
M20 Entry
ATEX/IECEX & AP approved SP XCD Hydrogen 0-1000ppm with SS316, M20
SPXCDASMG1
Entry
SPXCDALMB1 XCD CO2(Carbon Dioxide) IR 0-2%VOL with Aluminium Alloy, M20 Entry
AP Sensing’s fiber optic, linear heat detection systems leave no area unmonitored and display the real-time
temperature and heat transfer of the entire area at once. Based on the quantum mechanical RAMAN-effect and
a patented code-correlation measurement technique AP Sensing’s “Linear Heat Series” measures an accurate
temperature profile along the optical fiber over several thousand meters with measurements every 10 seconds.
With an extremely high level of integration and unique optical assembly technology, AP Sensing offers you full
protection combined with worry free permanent operation.
Enabling fast, reliable and cost-effective sensing through highly integrated optical measurement systems.
AP Sensing DTS will provide temperature monitoring for;
• Fire Detection
• Power cable monitoring
• Oil & Gas downhole performance monitoring
• Pipeline leakage detection
Suitable applications include large distributed manufacturing facilities, refineries, power plants, silos,
warehouses, cold stores, conveyor belt systems, cable trays and tunnels
• Suitable for Harsh and Hazardous areas
• Continuous temperature monitoring
• Ability to integrate into management systems
68 deg C
System Sensor Linear Heat Detection
Part # Description
System Sensor’s linear heat detection system SS-LD-68-155-100 Linear Heat Cable 68deg, 100m roll
is a fixed temperature device consisting of the
SS-LD-68-155-200 Linear Heat Cable 68deg, 200m roll
conductor cable and an EOL box.
SS-LD-68-155-500 Linear Heat Cable 68deg, 500m roll
When heated to the rated temperature, the SS-LD-68-155-1000 Linear Heat Cable 68deg, 1000m roll
heat sensitive polymer insulation melts
allowing the inner conductors to contact each 78 deg C
other initiating an alarm state. Part # Description
SS-LD-78-172-100 Linear Heat Cable 78deg, 100m roll
This type of detection is widely used in
SS-LD-78-172(200M) Linear Heat Cable 78deg, 200m roll
industrial, petrochemical, refinery and power
generation plants. SS-LD-78-172-500 Linear Heat Cable 78deg, 500m roll
SS-LD-78-172-1000 Linear Heat Cable 78deg, 1000m roll
• Continuous sensitivity along the length of
cable 88 deg C
• Easy to install, test and splice
Part # Description
SS-LD-88-190-100 Linear Heat Cable 88deg, 100m roll
FPA Equipment Listing #: SS-LD-88-190-200 Linear Heat Cable 88deg, 200m roll
NI/ 209, 210, 211, 212
SS-LD-88-190-500 Linear Heat Cable 88deg, 500m roll
SS-LD-88-190-1000 Linear Heat Cable 88deg, 1000m roll
105 deg C
Part # Description
SS-LD-105-220-100 Linear Heat Cable 105deg, 100m roll
SS-LD-105-220-200 Linear Heat Cable 105deg, 200m roll
SS-LD-105-220-500 Linear Heat Cable 105deg, 500m roll
SS-LD-105-220-1000 Linear Heat Cable 105deg, 1000m roll
Accessories
Part # Description
8687/EOL 47k End of line box
MB LHD Junction Box to suit linear heat cable
When heated to the rated temperature, the SS-LDN-68-155-1000 Linear Heat Cable 68deg, with nylon coating, 1000m
105 deg C
Part # Description
SS-LDN-105-220-100 Linear Heat Cable 105deg, with nylon coating, 100m
SS-LDN-105-220-200 Linear Heat Cable 105deg, with nylon coating, 200m
SS-LDN-105-220-500 Linear Heat Cable 105deg, with nylon coating, 500m
LDN-105-220(1000m) Linear Heat Cable
SS-LDN-105-220-1000
105deg, with nylon coating, 1000m
Accessories
Part # Description
8687/EOL 47k End of line box
MB LHD Junction Box to suit linear heat cable
VESDA DETECTORS
VESDA-E VEU
VESDA DETECTORS
VESDA-E VEP
Part # Description
VESDA Laser SCANNER with 7
VLS-204 Vesda FD7 Scanner, 2x Blank, Display, 7 Relays fitted
Relay
VLS-210 Vesda FD7 Scanner, 2x Blank, Programmer, 7 Relays fitted
Termination Card
VLS-214 Vesda FD7 Scanner, 1 Blank plate & Display & Programmer
• Four Pipes Vesda FD7 Scanner, Blank with FIRE 1 and OK LED’s plus Blank, Blank and 7
VLS-600
• Four Zones Relays
• AutoLearn™ Smoke
Part # Description
VESDA Laser SCANNER with 12 Relay
Termination Card Vesda FD12 Scanner, Blank with FIRE 1 and OK LED’s plus Blank, Blank and
VLS-700
12 Relays
• Four Pipes VLS-304 Vesda FD12 Scanner, 2x Blank Display, 12 Relays fitted
• Four Zones VLS-310 Vesda FD12 Scanner, Blank, Programmer, Blank, 12 Relays
• AutoLearn™ Smoke
VLS-314 Vesda FD12 Scanner, 2x Blank, Display, Programmer, 12 Relays
VESDA ACCESSORIES
Part # Description
VHH-100 Hand Held Programmer inc Cable
VHX-1200 HLI – Wall mounted inc VESDAnet socket
VHX –0200 HLI – Vesdanet PC Link Windows, used with VSM3
VHX-1420-HFS Modbus HLI (Honeywell version) to suit Vesda Net gateway
• Multiple emitters for power input OSE-HP-01 OSID Emitter - High Power, Alkaline battery
• Ball & Socket adjustment OSE-SPW OSID Emitter Standard Power/24V Wired Version
• Laser alignment tool OSE-HPW OSID Emitter High Power/24V Wired Version
Part # Description
OSID-EHE OSID Emitter Environmental Housing
OSID-WG OSID Wire Cage
OSE-ACF OSE Anti-Condensation film to suit OSID-EHE (10pk)
Panel mount 24VDC power supply and battery NPS-11 11.7A Stand-alone Power Supply
charger.
Accessories
• Certified to AS4428.5
Part # Description
• Includes fault output relays
• Replaces PS249 NPS-DISP Display kit to suit NPS power supplies, provides status and battery test switch
BATTERIES
secondary power supply to equipment. BATT12 SLA Battery 12AH - 151mm(L) x 98mm(W) x 101mm(H)
BATT18 SLA Battery 18AH - 181mm(L) x 77mm(W) x 167mm(H)
• Approved to AS1603.4
BATT22 SLA Battery 22AH - 181mm(L) x 77mm(W) x 167mm(H)
NOTE: 2 x batteries required for 24V system BATT26 SLA Battery 26AH - 175mm(L) x 166mm(W) x 125mm(H)
BATT33 SLA Battery 33AH - 195mm(L) x 130mm(W) x 180mm(H)
BATT40 SLA Battery 40AH - 197mm(L) x 165mm(W) x 170mm(H)
BATT75 SLA Battery 75AH - 258mm(L) x 166mm(W) x 206mm(H)
BATT85 SLA Battery 85AH - 305mm(L) x 168mm(W) x 212mm(H)
BATT100 SLA Battery 100AH - 330mm(L) x 172mm(W) x 221mm(H)
BATT150 SLA Battery 150AH - 485mm(L) x 172mm(W) x 240mm(H)
Part # Description
SOLO Smoke & Heat Detector Kits Smoke & Mains Heat detector test and removal kit (Contains Solo330,
SOLO814
Solo424, Solo100, Solo200 and Solo610) (6m reach)
Solo Detector test kits for use in testing
Smoke & Cordless Heat detector test and removal kit (Contains Solo330 ,
smoke & heat detectors. SOLO822
Solo461, Solo100, Solo200 and Solo610) (6m reach)
Smoke & Cordless Heat detector test and removal kit (Contains Solo330,
SOLO823
Solo461, 3x Solo100, Solo200 and Solo610) (9.3m reach)
SOLO AEROSOLS
and smoke detectors. They may also be used in SMOKEPEN-R Smoke Pen refills (pk of 6)
areas of high airflow to determine airflow
direction.
specifically for the System Sensor and XR2B Removal tool for 100B/800 series detectors
Notifier range of conventional and
addressable detectors
microphone
• Features low (30-80db) and High (80-130dB)
level
• Frequency range 31.5 - 8,000Hz
• Dynamic range 50dB / Accuracy: +/- 1.4dB
• Two built in weighting curves (A & C
weighting)
• Supplied with carry case, tripod mounting
adaptor and mic wind screen
• requires 1x 9V long life battery (included)
• Dimensions: 252H x 66W x 33D mm
MODULE ENCLOSURES
Cabinet Dimensions:
- 300mm H x 200m W x 150mm D
CABINET SURROUNDS
NOTE: Contact your Notifier systems consultant for alternate (custom) dimensions
INSTALLATION CABLE
• Twisted & flat versions available TPS-0.75-2C-500 TPS Flat Cable (500m) 2-core x 0.75mm2
TPS-1.00-2CW-200 TPS Flat Cable (200m) 2-core x 1.00mm2, white stripe
TPS-1.00-2CW-500 TPS Flat Cable (500m) 2-core x 1.00mm2, white stripe
TPS-1.5-2C-200 TPS Flat Cable (200m) 2-core x 1.5mm2
TPS-1.50-2C-500 TPS-Flat Cable (500m) 2-core x 1.50mm2
TPS-1.50-2CW-200 TPS Flat Cable (200m) 2-core x 1.50mm2, white stripe
TPS-1.50-2CW-500 TPS Flat Cable (500m) 2-core x 1.50mm2, white stripe
TPS-1.50-2CT-200 TPS Twisted Cable (200m) 2-core x 1.50mm2, twisted
TPS-1.50-2CT-500 TPS Twisted Cable (500m) 2-core x 1.50mm2, twisted
200 TPS Twisted Screened cable (200m) 2-core x 1.50mm2, twisted &
TPS-1.50-2CTS-200
screened
TPS-1.50-2CTS-500 TPS Twisted Screened cable (500m) 2-core x 1.50mm2, twisted & screened
GENERIC
POWER SUPPLIES
NPS-DISP Display kit for NPS power supplies, provides indication and battery test switch
PRINTER EQUIPMENT
PRN-80 Panel Printer Kit - includes Thermal Printer, DC-DC converter and metalwork
SCS-8AU/00 Smoke Control Station with 8 x 3 position switches with 3 x LEDs per switch - e.g. AS1668 fan controls
ACM-32AAUS/00 Annunciator Module with 32 Red LED. E.g. Flow switches, monitors etc.
LDM-R32 Lamp driver relay kit 32 Relays (requires 10460 LDM-32). E.g. Plant & EWIS Interfaces.
SOLO720 SOLO Replacement Battery Baton, for use with the SOLO461 Heat Detector Tester
I-2000 EWIS
CB-MIC CB-style Balanced EWIS Microphone, supplied with mounting clip to suit 10W/25W/50W Evac modules
FA2029 I2000 Membrane Keyboard 8 Zones, 3 WIP/Zone for use on 21U cabinets
KT0519 200W Amplifier Kit - 2 x AMP cards + wiring loom for I-2000
ME0205 Panel 8 Zone Display Extender / 3 WIP Display Keyboard Assembly for use on I2000 (Metalwork, mylar and PCB)
ME0207 Control Panel ECP, 3 WIP/ Zone 699-093 for use on I2000 (Metalwork, mylar and PCB)
PA0643 Evac Control Panel 3WIP/Zone PCB Assy for I2000, ECP9702-2
PA0647 200w Amplifier Card Module for I2000, AMP2009 (Single Amp)
PA0649 Secondary Panel Interface Module for I2000, (DIN) PCB Assy SPIF9709
PA0690 2x50W / 1 x 100W Amplifier Card Module PCB Assy for I2000, HAMP9308
PA0691 2x50W Transformer Card Module PCB Assy for I2000, HTRN9308-1
PA0692 1x100W Transformer Card Module PCB Assy for I2000, HTRN9308-2
PA0696 1x100W Transformer Card B495Module Music Switch for I2000, HTMS9408-2
PA0697 Strobe Termination Board PCB Assy for I2000, STRM9502, 8 Strobe/ 16 Relay Module (DIN)
PA0698 Evac Communication Module, PCB Assy for I2000, (DIN) ECM9603
PA0795 4 x 10W Transformer Module without Relays for I2000, TRAN 9706-1
PA0796 4 x 10W Transformer Module for I2000, c/w Relays, TRAN 9706-2
PA0916 WIP Termination PCB Assy for I2000, (common 0V version) DIN WTRM
SU0168 EWIS Gooseneck Microphone and bracket to suit I-2000 paging console, DM-521 B
VESDA
VESDA (Continued)
VSP-710 VLF-02 Spare Front cover with serv. pan. ASIAN Language Set 1
VSP-990 VESDA-E VEA 6mm Microbore Tube UL-compliant Plenum-rated (1000 ft)
VSP-991 VESDA-E VEA 4mm Microbore Tube UL-compliant Plenum-rated (500 ft)
OSID
Zones
In which an explosive gas/dust and air mixture In which an explosive gas/dust and air In which an explosive gas/dust and air
is present continuously or is present for long mixture is likely to occur in the normal mixture is not likely to occur in the normal
periods. operation of the plant. operation.
Type of Protection
Ex ma Encapsulation
Ex d Flameproof
Ex e Increased safety
Ex s Special protection
Ex m/ Ex MD/ Ex mb encapsulated
Any design suitable for Zone 1 plus
Ex n or N Non sparking (Non-incendive)
2 Ex ib Intrinsically-Safe
Ex o Oil immersion
Ex q Powder / sand filled
Apparatus Group
Easier to ignite
Ethylene Group IIB
Propane Group IIA
Methane Group I
Temperature Class
Easier to ignite
T3 200
T4 135
T5 100
T6 85
No Protection 0 0 No Protection
Protection against solid bodies larger than 50mm 1 1 Protected against vertically-falling drops of water or condensation
(e.g accidental contact with the hand)
Protection against solid bodies larger than 12.5mm 2 2 Protection against drops of water falling at up to 15º from the vertical
(e.g finger on the hand)
Protection against solid bodies larger than 2.5mm 3 3 Protection against drops of water falling at up to 60º from the vertical
(e.g tools, wires)
Protection against solid bodies larger than 1 mm 4 4 Protection against drops of water from all directions
(e.g small wires, fine tools)
Protection against dust 5 5 Protection against jets of water from all directions
(no harmful deposits)
Completely protected against dust 6 6 Completely protected against jets of water of similar force to heavy seas
Dual IR (IR2)
Triple IR (IR3)
Single IR
UV/IR2
UV
Optical Interference Sources
Arc Welding
Modulated IR Radiation
Electrical Sparks
Lightning
Radiation (Nuclear)
Sunlight
Artificial Lighting
UV Lamps
Smoke
Effects to Sensitivity
Steam
Water Spray
Oil Film
Dust
Low immunity to false sources High Immunity to false sources Excellent Immunity Highest Immunity
- Lowest Cost to false sources to false sources
- Fastest Response Time (Indoor Areas)
(Indoor or Outdoor Areas) (Indoor or Outdoor Areas)
(For Enclosed & Dark Areas)
The oil and gas industry covers a Probably one of the largest users Traditionally coal and oil have been Waste Water Treatment Plants are a
large number of upstream activities of gas detection equipment are used as the main fuel for Power familiar site around many cities and
from exploration and production of oil Chemical Plants. They often use a Stations. towns. Sewage naturally gives off
and gas to its transportation, storage wide range of both flammable and In Europe and the US most are both Methane and
and refining. The large amount of toxic gases in their manufacturing being converted to natural gas. H2S. The ‘rotten eggs’ smell of H2S
highly flammable Hydrocarbon gases processes or create them as by- can often be noticed as the nose can
involved are a serious explosive risk products of the processes. Typical Applications: detect it at less than 0.1ppm.
and additionally toxic gases such as • Around the boiler pipe work and
Hydrogen Sulphide are often present. Typical Applications: burners Typical Applications:
• Raw material storage • In and around turbine packages • Digesters
Typical Applications: • Process areas • In coal silos and conveyor belts in • Plant sumps
• Exploration Drilling Rigs • Laboratories older coal/oil fired stations • H2S Scrubbers
• Production Platforms • Pump rows • Pumps
• Onshore oil and gas • Compressor stations Typical Gases:
terminals • Loading Areas Flammable: Typical Gases:
• Refineries Natural Gas, Hydrogen Flammable:
Typical Gases: Toxic: Methane, Solvent
Typical Gases: Flammable: Carbon Monoxide, vapours
Flammable: General Hydrocarbons SOx, NOx and Oxygen Toxic:
Hydrocarbon gases Toxic: deficiency Hydrogen Sulphide,
Toxic: Various including Carbon Dioxide,
Hydrogen Sulphide, Hydrogen Sulphide, Chlorine, Sulphur Dioxide,
Carbon Monoxide Hydrogen Fluoride Ozone.
and Ammonia
Boiler Rooms come in all shapes and sizes. Small Hospitals may use many different flammable and Car Tunnels and enclosed Car Parks need to be
buildings may have a single boiler whereas larger toxic substances, particularly in their laboratories. monitored for the toxic gases from exhaust fumes.
buildings often have large boiler rooms housing Additionally, many are very large and have onsite Modern tunnels and car parks use this monitoring
several large boilers. utility supplies and backup power stations. to control the ventilation fans.
Tunnels may also need to be monitored for the
Typical Applications: Typical Applications: build up of natural gas.
• Flammable gas leaks from the incoming gas main • Laboratories
• Leaks from the boiler and surrounding gas piping • Refrigeration plants Typical Applications:
• Carbon Monoxide given off badly maintained • Boiler rooms • Car tunnels
boiler. • Underground and
Typical Gases: enclosed car parks
Typical Gases: Flammable: • Access tunnels
Flammable: Methane, Hydrogen • Ventilation control
Methane Toxic:
Toxic: Carbon Monoxide, Typical Gases:
Carbon Monoxide Chlorine, Ammonia, Flammable:
Ethylene oxide and Methane (natural gas),
Oxygen deficiency LPG, LNG, Petrol Vapour.
Toxic:
Carbon Monoxide,
Nitrogen Dioxide
The following terms and conditions apply where Honeywell Limited (ACN 000 646 882) t/a 3.3 Subject to these Conditions, and only in relation to any Services provided by
Honeywell Security & Fire (“HSF”) supplies goods or services to a customer (“Customer”). HSF to a Customer who is not a consumer as defined by the Australian
Consumer Law, HSF hereby expressly warrants that for three (3) months
1. Definitions from date of provision, the Services shall be free from Errors. HSF will if any
For the purpose of these Conditions and unless the context otherwise requires: Errors occur in Services, during the Services Warranty Period, at its election,
“Australian Consumer Law” means the Australian Consumer Law set out in either:
Schedule 2 of the Competition and Consumer Act 2010 (Cth), as supplemented or (a) supply the Services again; or
amended. (b) pay the cost of having the Services supplied again.
“Conditions” means these Terms and Conditions of Sale. 3.4 Clauses 3.1,3.2 and 3.3 will not apply to Errors attributable to:
“Contract” means the contract formed in accordance with clause 2.1, consisting of (a) Non-HSF Goods or Services;
HSF’s proposal (if any), the relevant invoice and these Conditions and where (b) any modification or repair of Goods unless made by HSFor with HSF’s
applicable, Special Conditions of Subcontract relating to the Code and Guidelines. prior written approval;
“Equipment” means equipment manufactured by HSF or its affiliates. (c) negligent use, abuse or misuse of Goods;
“Errors” means the failure of Goods to perform a function as described in the HSF (d) the use of Goods under environmental, power or operating conditions
proposal, the HSF functional specification for those Goods, the appropriate HSF user beyond the limits or constraints specified by HSF;
manual or HSF product literature as the case may be. (e) the installation or wiring of any Goods other than in accordance with
“Goods” means Equipment or Software. HSF’s instructions;
“GST” means the tax imposed by the A New Tax System (Goods & Services) Act (f ) the use of any Goods with any Non-HSF Goods or Services; or
1999 (Cth) and related imposition Acts of the Commonwealth. (g) wear or burn-out resulting from usage of goods of a kind inherently
“Index” means the average weekly earnings measure (as per ABS No. 6302, Series susceptible to burn-out.
No, A594406R [or such other ABS reference as may be substituted for the measure]) 3.5 HSF authorises Customer to pass on the express warranties contained in
or in the event that this Index is discontinued, the Australian Bureau of Statistics clauses 3.2 (a) and (b) (as applicable) to end users who purchase Goods from
index that most reflects the Index’s constituents. Customer, provided that:
“Loss or Damage” includes all types of property, pecuniary or other loss or damage, (a) Customer is not authorised to, and must not purport to, pass on to
including consequential loss or damage and loss of profits. such end-users any warranty rights greater than, or different to, those
“Non-HSF Goods or Services” means equipment, documentation, product literature, granted by HSF in clause 3.2(a) or (b) (as relevant); and
labour, knowledge, service or computer programs in machine readable form that is (b) if Customer wishes to pass on the warranty rights granted in clause
supplied, manufactured, installed or provided by a person other than HSF. 3.2 (a) or (b) in writing, Customer must provide HSF with a copy of
“Person” includes a corporation. the document which it proposes to use for this purpose for review
“Services” means HSF labour or service. and written approval by HSF before such document is provided to the
“Software” means computer programs developed by HSF or its affiliates in the form end-user.
of machine readable instructions and any documentation or product literature relating 3.6 Our Goods come with guarantees that cannot be excluded under the
to those computer programs. Australian Consumer Law. Customer is entitled to a replacement or refund
“System” may include HSF equipment and software and Non-HSF Goods or for a major failure and for compensation for any other reasonably foreseeable
Services. Loss or Damage. Customer is also entitled to have the Goods repaired or
replaced if the goods fail to be of acceptable quality and the failure does not
2. Contract Formation amount to a major failure.
2.1 Subject to clause 2.3, a binding agreement will form between the parties: 3.7 This clause 3 states HSF’s total responsibility and liability, and Customer’s
(a) if these Conditions form part of a proposal to Customer, on receipt by sole remedy in respect of the Goods and Services. In no event will HSF be
HSF of Customer’s unconditional acceptance of the proposal, liable for any incidental, consequential, special, or indirect damages, even if
evidenced by Customer’s purchase order whether or not the proposal informed of the possibility of such damages and notwithstanding the failure
is referenced; or of the essential purpose of any limited remedy. No extension of this warranty
(b) otherwise, on HSF’s written acceptance of Customer’s purchase will be binding upon HSF unless set forth in writing and signed by HSF’s
order; and the Contract will constitute the entire contract between authorised representative.
the parties in connection with the sale of Goods and Services.
2.2 Any proposal incorporating these Conditions: 4. Limitation of Liability
(a) will not be valid after 30 days of its date, unless otherwise agreed by 4.1 To the full extent permitted by law and subject to clauses 3.1, 3.2 and 4.2:
HSF; and (a) HSF makes no warranty and will not be liable for any breach of
(b) may be varied or withdrawn by HSF at any time prior to unconditional statutory obligation or implied condition or warranty in respect of
acceptance by Customer. Goods and Services or the materials used, Systems or results of any
2.3 No modifications or variation of the Contract (including any statement by process with which the Goods and Services are used or integrated;
Customer that Customer’s terms will apply) shall bind HSF unless expressly (b) HSF shall under no circumstances be liable in any way whatsoever to
agreed to in writing by an authorised representative of HSF. HSF will not be Customer for any Loss or Damage sustained or incurred by Customer
deemed to have waived these Conditions if it fails to object to provisions or any other party arising directly or indirectly out of the supply of
submitted by Customer. Goods or Services by HSF, the use or performance of Goods or
2.4 These Conditions will prevail in relation to the supply of Goods and Services Services in isolation or as part of a System, any breach by HSF of
to the extent of any inconsistency between these Conditions and any other the Contract, or negligence of HSF. HSF’s liability to the Customer, if
documentation agreed by HSF under clause 2.3. any, in contract, tort or otherwise will be reduced to the extent the
Customer contributed to the Loss or Damage;
3. Express Warranty (c) HSF does not make any representations or give any warranty as to
3.1 Subject to these Conditions, HSF hereby expressly warrants that: the overall performance of any System or the results of any process
(a) Goods manufactured by HSF in its Baulkham Hills, New South Wales with which the Goods or Services are used or integrated; and
facility shall be free from Errors for thirty six (36) months from date of (d) the express warranties in clauses 3.1 and 3.2 is in substitution for all
supply or installation (whichever is the earlier) of the Goods (the other terms, conditions, warranties and representations, implied by
Goods Warranty Period). Any Non-HSF Goods sold by HSF, but not statute or otherwise, and all other terms, conditions, warranties and
manufactured by HSF, will be provided with the same warranty as representations are excluded.
provided by the original manufacturer; and 4.2 Where the Australian Consumer Law imposes statutory consumer
(b) Services performed by HSF shall be free from Errors for twelve (12) guarantees in respect of Services provided by HSF to the Customer, and
months from the date of performance of the Services (Services the Services are of a kind not ordinarily acquired for personal, domestic or
Warranty Period). household use or consumption, then the Customer’s remedies for breach of
3.2 HSF will if any Errors occur in Goods, during the Goods Warranty Period, at any such statutory consumer guarantee shall be limited to, at HSF’s election:
its election, either: (a) re-supply of the Services; or
(a) in the case of Equipment, (b) payment of the cost of having the Services supplied again.
(i) replace the Equipment or supply equivalent equipment FOB at 4.3 This clause 4 will survive termination or completion of the Contract.
HSF’s facility; or
(ii) repair the Equipment; or 5. Price and Terms of Payment
(iii) pay the cost of replacing the Equipment; and 5.1 Unless stated otherwise in writing, all prices quoted by HSF, are exclusive
(b) in the case of Software, of all taxes, (including any GST), duties, levies and any other government
(i) repair, modify or make good the Software; or charges, and where applicable shall be added to the price payable by the
(ii) make available to Customer instructions to enable Customer to Customer to HSF. When GST is payable by HSF in respect of a taxable supply
repair, modify or make good the Software; or made by HSF to the Customer, the Customer shall pay HSF, in addition to
14. Variations
Subject to its statutory obligations in relation to the supply of services under the
Australian Consumer Law, HSF reserves the right to revise at any time the extent or
type of goods or services it supplies to the Customer, if it believes that other goods
or services supplied by HSF can fulfil the same function.
1 BEXCP3A-BG-LF 31
FDM-1
FDMR-1
18
18
BEXCS110-L2D 23 Fibre Optic Linear Heat Detection 35
1668x2 4
BEXL15D100V 23 FIM 48
18U 43
BExS110D24DC 26 Fire Rated Cable 47
18U/BB 43
BExS120D24DC 26 FirstVision 9
2012/24AUS 11
C Flashni 24
Flush surrounds for panels 43
2012J 11
CAB650BB-BK 43 FMM-1 18
2151BAUS 11
Capillary tube 40 FMM-101 18
28U 43
Ceiling Speaker 23 FRM-1 18
28U/BB 43
Centaur Bracket 44 FSB-200 15
4 CFP-16
CHS-1L
3
44
FSB-200S
FSP-851AUS
15
15
CHS-2 44 FSP-851AUS/BCK 15
40U 43
CHS-2L 44 FSL-751 15
5 CHS-3L
CHS-4
44
44
FSP-851AUS
FST-851AUS
15
15
CHS-4L 44 FST-851HAUS 15
5151AUS 11
CHS-6 44 FST-851RAUS 15
5151HAUS 11
CMM-2 22 FST-851R-WP 15
5151HRAUS 11
Code Red Bracket 44 FST-851-WP 15
5151RAUS 11
CPU (spare parts) 49 - 52 FZM-1 18
8 D G
885WP-B 11
D2 Duct Detector 12 Gas card See Agent Release Module
A D4120W
DA-120
12
22
Gas Detectors
Graphics
34
See OnyxWorks, See OnyxWorks
DA-120/CAB 22 Green MCP 30
AAM 18
DA-30 22
ABF-1B
ABF-1DB
44
44
DA-30CAB 22 H
DA-60 22
ABF-2B 44
DA-60CAB 22 HASP 40
ABF-2DB 44
DAA2-5070E 21 Horn Speaker 23, 24
ABF-4B 44
DA-DISPA 22 HS-NCM-MF 8
ABS-1B 44
DA-DISPB 22 HS-NCM-MFSF 8
ABS-1TB 44
DA-DISPC 22 HS-NCM-SF 8
ABS-2B 44
DA-DISPD 22 HS-NCM-W 8
ABS-2D 44
DBS-4-W 25 HS-NCM-WMF 8
ABS-4D 44
DBSLIDW 25 HS-NCM-WSF 8
ACM-16ATAUS/00 48
Detector guards 17
ACM-32AAUS/00
ACM-8RA
48
3
DGP1B 43 I
DGP2B 43
Agent Release Module 26
Digital Audio Amplifiers 21 IDX-1E 13
Almos Bracket 44
Digital Voice Command 21 IFS-1125C 49
Annunciator Enclosures 44
DNR-AUS 17 IFS-2004C 49
ASE bracket 44
DNRW 17 IFS-713 See CPU, See CPU
DS-FM 21 IFS-717E See RLY8
B DS-SFM 21 IFS-724 See FIM
DST1.5 12, 17 IFS-725I 48
B401 11 DST10 12, 17 IFS-816 49
B501AUS-BK 15 DST3 12, 17 IFS-993F 4
B501AUS 15 DST5 12, 17 IMX-1E 13
B501AUS-W 15 Dual strobe 4, 24 IR2 Flame Detector 33
BACNET-GW 10 Duct detector (addressable) 17 IR3 Flame Detector 33
Batteries 42 Duct detectors (conventional) 12 IS Horn Sounder 25
Battery box 43 DVC-AOI 21 Isolation Barrier 48
BCK-200B/10 15 DVC-EM 21 IS-A105N-R 25
BDA-70V 21 DX070 48 IS-L101L 25
BEAM1224 12 IS-mA1-R 25
BEAM1224S 12 E IS-mB1 25
BEAMLRK 12, 15 IS-mC1-R/R 25
BEAMMK 12, 15 End cap (ASD pipe) 40 ISO-X 18
BEAMSMK 12, 15 ETX 12, 17
Bells 25 E60 - E240 12 J
BEXBG05D24DC-RD 24
BEXBG15D24DC-RD 24 F J piece 40
KFD0-CS-Ex1.54-Y2 48 U
P
L UniPoint Gas detector Controllers 34
Paging Console 22 Upload/Download cable 48
LaserCOMPACT 37 PBC-150 49 USB to RS232 Converter 48
LaserFOCUS 37 PBC-70 49 UV/IR Flame detector 33
LaserSCANNER 38 Pendant Speaker 24
LCD-80/2800 48 Pipe clip 40 V
LCM-320 5, 48 Pipe junction 40
LCS 24 Pressure switch 19 VESDA/ASD Pipe 40
LDM-32 7 Projection Speaker 24
LDM-R32 7 PS200 30, 31
LEM-320 5, 48 PS210 30, 31 W
LIM 48
Linear Heat Detection
Loop Control Module
35, 36
See LCM-320
R Warning sign face plate 29
White detector cover 15
Loop Expander Module See LEM-320 White MCP 30
Relay modules 3, 4, 44
Low profile chassis 44 WIP Handset 20
Remote indicator 17
WIP/BOX/IP66 20, 43
M Repeater
Resettable MCP
See RPT-F or RPT-WF
30 WSA-I/SI 29
Romteck Bracket 44 WSA-O/SI 29
M200E-DIN 18 WSR-I 29
Roshni 24
M200E-PMB 18 WSR-O 29
RPT-W 8
M200E-SMB-KO 18
RPT-WF 8
Magnetic Door Holders
MCP clear flap
32
30
RTS451Key 12 X
MDH/F
MDH1000
32
32
S XCD Gas Detector 34
XP module mounting 44
MDH1350 32
Sampling point 40 XP-10M 19
MDH400 32
SC070 30, 31 XP-4 44
MDHREM 32
SCS-8A 6 XP-6C 19
MDHW15 32
SCS-8LA 6 XP-6MA 19
MDHW30 32
SDM-4 22 XP-6R 19
MHRZA 25
SDX-851AUS 13
MHWZA 25
MIC/1D 22
Sensepoint XCD
SG-1x10
34
30, 31
Y
MIC/4D 22
Small bend 40
Mimic (LCD) See LCD-80 Y piece 40
SMB-500 18
Mini-Horn Sounder 25 Yellow MCP 30
SMK-400 11, 15
ModBus-GW-3 10
Smoke alarm See 2012
Z
N Smoke Pen
SMOKE-C
44
43
Zener barrier 48
SMOKE-CO 43
NCM-F 8 Z728 48
SMOKE-D 43
NCM-SF 8
SMOKE-S 43
NCM-W 8
SMOKESABRE 43
NFN-GW-AU-EM-3 10
SMOKE-T 43
NFN-GW-PC-F 9
SOLEX10 25
NFN-GW-PC-W 9
SOLO 43
NFS2 49
SP-125 23
NFS4 49
SP-320 49
NFS8 49
Speakers 24, 25
NIM 48
SpectrAlert 24
Notify-IP 9
SPH-15W 23
NPS-11 42, 49
SRHKRLFIRE 24
NPS-11/BBO 42
SSM Series Fire Bells 25
NPS-11S 42
STI-3150 24
NPS-2/BB 42
STI-9604 17
NPS-5 42, 49
Surge Suppression 48
NPS-5BB 42
Surrounds 43
NPS-5S 42
NPS-DISP
NTFast bracket
42, 49
44
T
NWS-3 10
T piece 40
O Test magnet
TPS Cable
44
47
Trunk adaptor 40
Onyx FirstVision 9
Type E Probe 12
OnyxWorks 9
Honeywell Security & Fire (Pacific) Honeywell Security & Fire (NZ)
Honeywell Ltd Honeywell Ltd
9 Columbia Way 56 Cawley St Ellerslie
Norwest Business Park AUCKLAND, NZ 1051
BAULKHAM HILLS NSW 2153 Visit: www.notifier.co.nz
Visit: www.notifier.com.au
Tel: +64 9 623 5050 (New Zealand)
Tel: 1300 234 234 (Australia) Email: [email protected]
DOC-02-183 – REV. A
informationguide2019