Aw Me Hvac 100
Aw Me Hvac 100
RT
H
LEGEND :
FLEXIBLE DUCT
Exhaust Duct
I.U INDOOR UNIT
VD VOLUM DAMPER
REFRIGERENT
RETURN FLOW BAR SIDWALL
PIPE GAS
S.G SUPPLY GRILLE
THERMOSTAT
ROOF PACKAGE
Fresh Duct
EX.F EXHAUST FAN
HUMIDIFIER
Kitchen Exhaust
Duct
REVISION STATUS :
-Feeding from the same machine for Storage Room 17 is difficult due to limited 1XS.G 8"X8"
-The supply air in DRIVER BATH 33 has been reduced to maintain negative 50 CFM
pressure inside the bathroom, preventing odors from escaping into adjacent space and long distance, affecting routing and static coverage. We suggest
adding a high-wall unit or leaving it as is. The return grille near the storage room N.C < 20
areas.
in the corridor creates negative pressure, pushing air outside and renewing the Air outlet P.D = .006 inches w.g
Note 3:
airflow. THROW = 1 M TO 1.8 M
There is a stove in this space that was not equipped with an exhaust hood in the
concept design. Accordingly, a hood has been added to address this
2XS.G 10"X10" SUPPLY AC requirement. 200x200 1XS.G 8"X8" 1XS.G 8"X8"
190 CFM 1XS.G 8"X8" Exhaust Air 155 CFM 105 CFM 1.3 TON 1XS.G 8"X8"
N.C < 20
Air outlet P.D = .016 inches w.g
65 CFM
N.C < 20
EXHAUST
4XE.G 8"X8"
75 CFM EACH
200x200
141.6 L/s
Exhaust Air 200x200
B.O.D=2865
200x200
1xR.G 8"X8"
155 CFM
1xR.G 8"X8"
105 CFM
FXMQ40PB
155 CFM
1xR.G 8"X8"
155 CFM
BUILDING KEY PLAN
THROW = 2.4 M TO 3.6 M Air outlet P.D = .014 inches w.g
THROW = 1.2 M TO 2.4 M
4XFLEX.D∅6"
N.C < 20
B.O.D=3030 Exhaust Air
B.O.D=2965
Exhaust Air
B.O.D=2865
N.C < 20
Air outlet P.D = .057 inches w.g
N.C < 20
Air outlet P.D = .025 inches w.g
V1 N.C < 20
Head Loss=.105 in.WC/100 ft
Air outlet P.D = .016 inches w.g THROW = 3.6 M TO 4.5 M THROW = 2.5 M TO 3.5 M 565 CFM Air outlet P.D = .057 inches w.g
5 Velocity=719 FPM
THROW = 3.6 M TO 4.5 M Note 5:
The hood and bathroom fan exhausts were relocated from the stairwell wall
outlets as the architect and structural engineer did not approve wall openings.
AW-ME-HVAC-102 250x200
122.7LAUNDRY
L/s
the white cirle on the wall refers to the old opens postions. 2XS.G 8"X8"
FXAQ20ARVM
150ø
WC WC 157.5 CFM
FXAQ20ARVM
FXAQ20ARVM
FXAQ20ARVM
FXAQ20ARVM
250x200 B.O.D=2945
FXAQ20ARVM
FXAQ20ARVM
565 CFM Air outlet P.D = .006 inches w.g Velocity=482 FPM 150 mm take off to
round duct to above
THROW = 1 M TO 1.8 M
1xR.G 12"X8" 200 Ф
200 CFM
STORAGE
EX.F-03 (CASSETTE)
75 CFM 16
ALEISA FAMILY
RESIDENCES
MEP CONTRACTOR:
DRAWING TITLE :
Sheet Contents:
AW-ME-HVAC-100