SOLAR PV MODULE (DCR/NON-DCR)
144 HALF CUT MONO PERC CELL
BIFACIAL TRANSPARENT BACKSHEET 525-555 W
TRANSITION TO
A BRIGHTER TOMORROW
• Based on M10-182mm wafer, best choice
for ultra-large power plant
• Advanced module technology delivers
superior module efficiency
• M10 Gallium-Dopped Wafer
• Smart Soldering
• 10 Busbar Half-Cut Cells
• ARC Coated, High Transmission Glass for
Higher Energy Yield
• High Module Quality Ensures
Long-Term Reliability
HIGH PERFORMANCE GUARANTEE!
30 LINEAR
YEARS WARRANTY FOR
POWER OUTPUT 12 WARRANTY
YEARS PRODUCT
India’s First DCR Module with M10 MonoPERC Cell
SMBB TECHNOLOGY Auto Bussing & Soldering Technology
Better light trapping and current collection to Induction based Improved soldering quality
improve module power output and reliability without pollution to module
PID Resistance Enhanced Mechanical Load
Excellent Anti-PID performance guarantee via optimized Certified to withstand wind lead (2400 Pascal)
mass-production process and materials control and snow load (5400 Pascal)
Higher Power Output IDEAL FOR
Module power increases 5-25% generally, bringing
significantly lower LCOE and higher IRR
Residential Commercial Utility Off-grid
C E R T I F I C AT I O N
IEC 62804 (PID) | IEC 61701 (Salt Mist) | IEC 61726 (Ammonia) | IEC 62782 (DMLT)
IEC 61853-1 & 2 (Panfile & IAM) | LID, LETID | IEC 60068 (Sand & Dust) | IEC 61215
IEC 62759 (Transportation) | CEC, INMETRO, CE | IEC 61730 | UL 61730
India’s Second Largest Integrated Solar PV Cell and Module Manufacturer | Available in All Black Range
SOLAR PV MODULE (DCR/NON-DCR)
144 HALF CUT MONO PERC CELL
BIFACIAL TRANSPARENT BACKSHEET 525-555 W
ELECTRICAL CHARACTERISTICS(STC) TEMPERATURE CHARACTERISTICS
PE PE PE PE PE PE PE Pmax Temperature Coefficient -0.35%/ºC
MODULE TYPE 525HB 530HB 535HB 540HB 545HB 550HB 555HB
Voc Temperature Coefficient -0.27%/ºC
Maximum Power (Pmp) 525 530 535 540 545 550 555
Ise Temperature Coefficient 0.04%/ºC
Open Circuit Voltage (Voc) 49.33 49.43 49.51 49.68 49.76 49.82 49.88
Operating Tempertarure -40ºC To + 85ºC
Short Circuit Current (Isc) 13.63 13.70 13.82 13.94 13.99 14.06 14.12
Nominal Operating Cell Temperature 42 ± 3º C
Maximum Power Voltage (Vmp) 40.93 41.02 41.11 41.21 41.30 41.41 41.41
Maximum Power Current (Imp) 12.83 12.93 13.03 13.11 13.21 13.29 13.40 Product Certificates*
Module Efficiency (nm) 20.32 20.52 20.71 20.90 21.10 21.29 21.48 IEC 61215, 61730/ INMETRO
(-0,+5W) UL 61730/IEC 61701/IEC 62716/IEC 60068-2-68
Power Tolerance
Maximum System Voltage 1500V(UL & IEC)
16
Maximum Series Fuse Rating 25 Amp Cells temp.=25ºC
14
*STC Irradiance 1000W/m2, Module Temperature 25ºC and AM 1.5 Measuring Tolerance: ±3% Incident Irrad. =1000W/m2
550.1W
12
2
Incident Irrad. = 800W/m
10 433.7W
Current [A]
ELECTRICAL CHARACTERISTICS(NOCT) Incident Irrad. = 600W/m2
8 319.2W
PE PE PE PE PE PE PE
MODULE TYPE 525HB 530HB 535HB 540HB 545HB 550HB 555HB 6 Incident Irrad. = 400W/m2 207.1W
Maximum Power (Pmp) 386 390 394 397 401 405 408 4
Incident Irrad. = 200W/m2 98.6W
Open Circuit Voltage (Voc) 46.09 46.19 46.26 46.42 49.49 46.55 46.61 2
Short Circuit Current (Isc) 10.87 10.92 11.02 11.11 11.15 11.21 11.26 0
0 10 20 30 40 50 60
Maximum Power Voltage (Vmp) 37.98 38.06 38.15 38.24 38.32 38.42 38.42 Voltage [V]
600
Maximum Power Current (Imp) 10.17 10.24 10.32 10.39 10.46 10.53 10.62 Cells temp.=25ºC 550.1W
Incident Irrad. =1000W/m2
Module Efficiency (nm) 14.95 15.09 15.23 15.38 15.52 15.66 15.76 500 Incident Irrad. = 800W/m
2
Incident Irrad. = 600W/m2 433.7W
Incident Irrad. = 400W/m2
*NOCT- Irradiance 800 W/m2, AM 1.5, Ambient Temperature 25ºC and Wind speed 1m/s Measuring Tolerance: ±3% 400 Incident Irrad. = 200W/m
2
Power [W]
319.2W
300
BIFACIAL GAIN (70±10%) PE PE PE PE PE PE PE 207.1W
525HB 530HB 535HB 540HB 545HB 550HB 555HB 200
10% Power Pmp 577.5 583.0 588.5 594.0 599.5 605.0 610.5 98.6W
100
20% Power Pmp 630.0 636.0 642.0 648.0 654.0 660.0 666
30% Power Pmp 682.5 689.0 695.5 702.0 708.5 715.0 721.5 0
0 10 20 30 40 50 60
Voltage [V]
• Bifacial gains depends on the power plant design and albedo of installation site
• Power Bifaciality=Pmax(Rear)/Pmax(Front) and Pmax Front are tested under STC Measuring Tolerance: ±3%
MECHANICAL SPECIFICATIONS
9 External Dimensions 2278(±2mm) x 1134 (±2mm) x 35(±1mm)
3.5 +
.5
R4
Weight 34 (± 3%) Kg
8
Drain Hole
8x3.5 - 16 No’s Solar Cells 10 BB, Mono PERC - crystalline 91mm x 182mm
14
9
Front Glass 3.2 mm, High Transmission, Low Iron, Tempered Glass
I Rear Cover High Transparent Backsheet
14
5:1
Mounting Hole Frame Anodized Aluminium Alloy (Silver/Black)
65
9x14 - 8 No’s
Junction Box 3 Split, IP 68 Rated
65
Mounting Hole
Connector Mc4 Compatible
Earth Hole
10
7x10-4 No’s ø5.1-2 No’s Mechanical Load 5400 Pa For Snow Load, 2400 Pa Wind Load
Common
2279
1400
990
400
II Fire Performance TYPE 29 ( UL 61730) Or Class C (IEC 61730)
Embossed 2:1
Split Junction Box Earth
Symbol Output Cable 4.0 mm2
400 mm Length
A A
FRAME PROFILE 35X35 AND 35X30MM
35/30
1088/1084
PACKING CONFIGURATION
35
Container 20’ GP 32’GP 40’HQ
Pieces per Pallet 31 31 31
65 Section A-A
135 35/30 10:1 Pallets per Container 8 16 20
1134
Pieces per Container 248 496 620
FIRST YEAR DEGRADATION < 2.0% YEAR 2-30 POWER DEGRADATION < 0.45%
For more details, please contact:
The specification and key features contained in this datasheet may deviate slightly from our actual
PREMIER ENERGIES GROUP products due to the on-going innovation and product enhancement, Premier Energies reserves the right
[email protected] | premierenergies.com to make necessary adjustment to the information described herein at any time without further notice.