-|Transparent Guide|-
DRW171188AB Safety Considerations
• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
• symbol indicates caution due to special circumstances in which hazards may occur.
Warning Failure to follow instructions may result in serious injury or death.
01. Fail-safe device must be installed when using the unit with machinery that
may cause serious injury or substantial economic loss. (e.g. nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.)
Compact Pressure Sensors
Failure to follow this instruction may result in personal injury, economic loss or fire.
02. Do not use the unit in the place where flammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact or salinity
may be present.
Failure to follow this instruction may result in explosion or fire.
03. Install on a device panel or to a pressure port directly to use.
Failure to follow this instruction may result in fire.
04. Do not connect, repair, or inspect the unit while connected to a power
source.
Failure to follow this instruction may result in fire.
05. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
06. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire or electric shock.
Caution Failure to follow instructions may result in injury or product damage.
01. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage.
02. Use a dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire.
03. This product is designed to detect the pressure of noncorrosive gas. Do not
use for corrosive gas.
Failure to follow this instruction may result in product damage.
04. Keep the product away from metal chip, dust, and wire residue which flow
into the unit.
Failure to follow this instruction may result in fire or product damage.
05. In case of reducer pressure port model, do not allow rotation, twist, pull,
moment load, vibration, impact, etc. to be applied to the one-touch fitting
after coupling.
Failure to follow this instruction may result in pressure port damage or poor
tightening.
PSS Series Cautions during Use
PRODUCT MANUAL
• Follow instructions in ‘Cautions during Use’.
Otherwise, it may cause unexpected accidents.
• 12 - 24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2,
SELV power supply device.
• Use the product, 3 sec after supplying power.
For your safety, read and follow the considerations written in the instruction
• When using switching mode power supply, frame ground (F.G.) terminal of power
manual, other manuals and Autonics website. supply should be grounded.
The specifications, dimensions, etc. are subject to change without notice for product • Wire as short as possible and keep away from high voltage lines or power lines, to
improvement. Some models may be discontinued without notice. prevent inductive noise.
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000 m
Features - Pollution degree 3
- Installation category II
• Rated pressure range
- negative pressure (0 kPa to -101.3 kPa)
- positive pressure (0 kPa to 100.0 kPa / 0 kPa to 1000 kPa)
- compound pressure (-101.3 kPa to 100 kPa)
• Compact size: W 11.8 mm × H 29.3 mm × L 24.8 mm (with pressure port)
• Analog output: voltage (1 - 5 VDCᜡ), current (DC 4 - 20 mA)
• Power supply: 12 - 24 VDCᜡ ±10%
ᜢᜫ
-|Transparent Guide|- -
Model Analog Output by Input Pressure Range
Rated Expanded Max. The analog output follows the rated pressure range, and the extended analog output
□: Pressure
Model name Pressure pressure analog output pressure Output range value outside the rated pressure range is not linear.
port
range range range
■ Static pressure ■ Compound pressure ■ Negative pressure
PSS-V01V-□ 0.0 to 5.0 to Rated pressure Voltage
Negative
-101.3 kPa -101.3 kPa ×2
Output voltage / current Output voltage / current Output voltage / current
PSS-V01A-□ Current 5 VDC 5 VDC 5 VDC
20 mA 20 mA 20 mA
PSS-01V-□ 0.0 to -5.0 to Rated pressure Voltage
PSS-01A-□ 100.0 kPa 110.0 kPa ×2 Current R1/8: R1/8
Static (Standard)
PSS-1V-□ 0 to -50 to Rated pressure Voltage R04: Ø4 reducer
PSS-1A-□ 1,000 kPa 1,100 kPa × 1.5 Current R06: Ø6 reducer 1 VDC 1 VDC 1 VDC
4 mA 4 mA 4 mA
Pressure (kPa) Pressure (kPa) Pressure (kPa)
PSS-C01V-□ Com -101.3 to -101.3 to Rated pressure Voltage 0 100/1000 -101.3 100 -101.3 0
PSS-C01A-□ -pound 100.0 kPa 110.0 kPa ×2 Current
Specifications
Series PSS series
Applicable medium Air, Non-corrosive gas
Pressure type Negative, Static, Compound
Rated pressure range Refer to ‘Model’.
Cable Ø 3 mm, 4-core, 3 m
Wire AWG28 (0.08 mm, 19-core) insulator diameter: Ø 0.88 mm
• R1/8 pressure port - Front/Rear case: PBT, Pressure port: Nickel
Material plated brass
• Reducer pressure port – Front/Rear case and pressure port: PBT
Protection structure IP40 (IEC standard)
Approval ᜢᜫ
Unit weight (packaged) ≈ 26 g (≈ 60 g)
Power supply 12 - 24 VDCᜡ ±10% (ripple P-P: ≤ 10%)
Current consumption Voltage output model: ≤ 15 mA
Effect by power supply ≤ ±0.3%F.S
Protection circuit Reverse polarity protection circuit
Voltage output 1 - 5 VDCᜡ ±2% F.S.
Linearity ≤ ±1% F.S.
Output impedance 1 kΩ
Current output DC 4 -20 mA ±2% F.S.
Linearity ≤ ±1% F.S.
Analog output temp.
≤ ±2% F.S. (in 0 to 50 ℃ temperature range, at 25 ℃)
characteristic
Insulation resistance ≥ 50 MΩ (500 VDCᜡ megger)
Dielectric strength 2,000 VACᜠ 50/60 Hz for 1 min
1.5 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y,
Vibration
Z direction for 2 hours
Ambient temperature 0 to 50 ℃, Storage: -10 to 60 ℃ (no freezing or condensation)
Ambient humidity 35 to 85%RH, Storage: 35 to 85%RH (no freezing or condensation)
Sold Separately
• Sensor connector plug: CNE-P04-□
• Pressure sensor indicators: PSM Series
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
11.8 19.8 5
12.8
Ø3, 3m
PT 1/8"
16.5
Inside: 1.6 Inside: 3.6
12 Inside M5 Tap
Ø4.0 Ø6.0
R1/8 Ø 4 reducer Ø 6 reducer
Connections
■ Voltage output ■ Current output
Brown +V Brown +V
LOAD
Black White
Voltage output Pressure sensor
12 - 24 VDCᜡ
12 - 24 VDCᜡ
model recognition
CIRCUIT
CIRCUIT
White
Pressure sensor Black N.C
model recognition
LOAD
Blue GND Blue
0 V / Current output
• There is no over current protection circuit. If the control output terminals are shorted
or supplied over the rated specification, it may result in product damage.
• Allowable load impedance: (12 VDCᜡ power) ≤ 100 Ω / (24 VDCᜡ power) ≤ 500 Ω
• Pressure sensor model recognition: Available only connecting with Autonics Pressure
sensor indicators PSM Series
• [Current output model] LOAD can be wired any direction.
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-2-2048-1577 |
[email protected]