0% found this document useful (0 votes)
98 views1 page

Indigenous Electrical Layout Abalde

The document outlines the electrical specifications and load schedule for a project, detailing the types and quantities of electrical outlets and lighting required. It includes general specifications for installation, such as ensuring weatherproof equipment and proper grounding, as well as guidelines for solar energy systems and electrical service extensions. Additionally, it emphasizes the need for GFCI protection in certain areas and proper marking of unused circuits.

Uploaded by

kirtbayot1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views1 page

Indigenous Electrical Layout Abalde

The document outlines the electrical specifications and load schedule for a project, detailing the types and quantities of electrical outlets and lighting required. It includes general specifications for installation, such as ensuring weatherproof equipment and proper grounding, as well as guidelines for solar energy systems and electrical service extensions. Additionally, it emphasizes the need for GFCI protection in certain areas and proper marking of unused circuits.

Uploaded by

kirtbayot1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SCHEDULE OF LOADS GENERAL SPECIFICATIONS

CIRCUI DESCRIPTION QTY. VI V I AF P AT HOMERUN 1.​ ENSURE THAT ELECTRICAL EQUIPMENT INSTALLED IN OPEN OR SEMI-OPEN
T NO. STRUCTURES IS WEATHERPROOF AND RATED FOR OUTDOOR USE.​

1 LIGHTING 3 100 220 1.35 50 2 15 2 - 3.5 MM^2 TW IN 20MMØ 2.​ ALL METAL PARTS NOT INTENDED TO CARRY CURRENT SHALL BE BONDED TO
OUTLET GROUND TO AVOID ELECTRICAL SHOCK HAZARDS.​

2 CONVENIENCE 2 180 220 3.27 50 2 20 2 - 3.5 MM^2 TW IN 20MMØ 3.​ SOLAR ENERGY SYSTEMS, IF USED, SHALL INCLUDE PROPER CHARGE
OUTLET CONTROLLERS, BATTERY STORAGE, AND INVERTERS DESIGNED FOR
COMMUNITY-SCALE USAGE.​
3 SPACE 1000
4.​ POWER DISTRIBUTION SHALL BE BALANCED TO AVOID OVERLOADING OF
TOTAL TOTAL 2020 4.62
TRANSFORMERS, PANELBOARDS, AND SERVICE ENTRANCE EQUIPMENT.​

5.​ EXTENSION OF ELECTRICAL SERVICE TO NEW STRUCTURES SHALL ONLY BE


DONE BY QUALIFIED PERSONNEL WITH PRIOR APPROVAL OF COMMUNITY
LEADERS OR ENGINEERS.​

6.​ ELECTRICAL OUTLETS IN KITCHENS, BATHROOMS, AND OUTDOOR AREAS


SHALL HAVE GFCI PROTECTION IN ACCORDANCE WITH PEC REQUIREMENTS.​

7.​ ALL UNUSED OR SPARE CIRCUITS IN THE PANEL BOARD SHALL BE PROPERLY
MARKED AND LEFT IN A SAFE, NON-ENERGIZED CONDITION.

SINGLE LINE DIAGRAM

UNIVERSITY

LEGEND
SYMBOL DESCRIPTION

PANEL BOARD

LIGHTING OUTLET

DUPLEX CONVENIENCE OUTLET

S1 SINGLE GANG SWITCH

OF SCIENCE PROJECT NAME DRAWN BY: PREPARED BY: CHECKED BY: APPROV SHEET NO:
AND TECHNOLOGY IN ED BY:
SOUTHERN PHILIPPINES
INDIGENOUS HOUSE RANDY O. ABALDE RANDY O. ABALDE ENGR. CONCORDIO CAHANSA 1