SCHEDULE OF LOADS GENERAL SPECIFICATIONS
CIRCUI DESCRIPTION QTY. VI V I AF P AT HOMERUN 1. ENSURE THAT ELECTRICAL EQUIPMENT INSTALLED IN OPEN OR SEMI-OPEN
T NO. STRUCTURES IS WEATHERPROOF AND RATED FOR OUTDOOR USE.
1 LIGHTING 3 100 220 1.35 50 2 15 2 - 3.5 MM^2 TW IN 20MMØ 2. ALL METAL PARTS NOT INTENDED TO CARRY CURRENT SHALL BE BONDED TO
OUTLET GROUND TO AVOID ELECTRICAL SHOCK HAZARDS.
2 CONVENIENCE 2 180 220 3.27 50 2 20 2 - 3.5 MM^2 TW IN 20MMØ 3. SOLAR ENERGY SYSTEMS, IF USED, SHALL INCLUDE PROPER CHARGE
OUTLET CONTROLLERS, BATTERY STORAGE, AND INVERTERS DESIGNED FOR
COMMUNITY-SCALE USAGE.
3 SPACE 1000
4. POWER DISTRIBUTION SHALL BE BALANCED TO AVOID OVERLOADING OF
TOTAL TOTAL 2020 4.62
TRANSFORMERS, PANELBOARDS, AND SERVICE ENTRANCE EQUIPMENT.
5. EXTENSION OF ELECTRICAL SERVICE TO NEW STRUCTURES SHALL ONLY BE
DONE BY QUALIFIED PERSONNEL WITH PRIOR APPROVAL OF COMMUNITY
LEADERS OR ENGINEERS.
6. ELECTRICAL OUTLETS IN KITCHENS, BATHROOMS, AND OUTDOOR AREAS
SHALL HAVE GFCI PROTECTION IN ACCORDANCE WITH PEC REQUIREMENTS.
7. ALL UNUSED OR SPARE CIRCUITS IN THE PANEL BOARD SHALL BE PROPERLY
MARKED AND LEFT IN A SAFE, NON-ENERGIZED CONDITION.
SINGLE LINE DIAGRAM
UNIVERSITY
LEGEND
SYMBOL DESCRIPTION
PANEL BOARD
LIGHTING OUTLET
DUPLEX CONVENIENCE OUTLET
S1 SINGLE GANG SWITCH
OF SCIENCE PROJECT NAME DRAWN BY: PREPARED BY: CHECKED BY: APPROV SHEET NO:
AND TECHNOLOGY IN ED BY:
SOUTHERN PHILIPPINES
INDIGENOUS HOUSE RANDY O. ABALDE RANDY O. ABALDE ENGR. CONCORDIO CAHANSA 1