Anti-static Eliminator - Eliminator power unit
• After decades of research and design, the internal high-voltage structure has reached a high-
efficiency high-voltage transformation device in conversion. It uses the mains frequency voltage without
converting the voltage to reduce the fault problem. It provides a variety of options such as power indicator
and fault indicator in panel operation. If the device has no discharge loss, it can be used for a long time (it
needs to keep the environment clean and appropriate temperature). The electrostatic elimination device
can drive multiple groups of electrostatic elimination rods (the total length of the
electrostatic elimination rods shall be less than 6m), electrostatic elimination gun
series and electrostatic fan series. The electrostatic elimination device consumes very low power in
terms of power demand and only needs about 20W / h
• The high-voltage output port is connected with a special designed fast high-voltage connector,
which is simple, safe, fast and convenient. 1-to-4 adapter box can also be used to reduce the cost.
• Adopting the traditional winding structure without using the electronic voltage doubling
method can be more stable and have long service life.
• The host series of electrostatic elimination device will encounter high-voltage output fault in use.
It can be equipped with high-voltage abnormal power-off safety control device to improve safety to
ensure industrial safety
• The electrostatic elimination device series can be customized according to customer
requirements for various input voltage power supplies 110V, 220V, 380V, 440V and output 5kV, 7kv,
9KV, 11kv, 12kV, 15kV at high voltage side... (please call for special specification.)
High voltage abnormal power-off safety control device
The whole series of Static elimination device power unit can be equipped with safety protection power-off
system against electric shock and fire! In case of abnormal high- voltage leakage of the electrostatic
elimination unit, abnormal damage inside the host, abnormal high-voltage conductor of the connecting
device, insulation damage of the electrostatic elimination device, etc., the digital control can quickly respond
within 1
second, cut off the high-voltage output power supply and display an alarm to inform the operator, so as to
quickly deal with the industrial safety problems. (The power-off controller is only used for the static
elimination and cannot be used for other purposes.) Abnormal power-off controller: when resetting without
using the reset button, cut off the power supply for about (3 seconds) and restart it, and then reset the monitoring.
Products still protected by patents, patented product counterfeiting not allowed.
certificate of grant of patent: M 495697 (number)
*power unit=host
*HV=high voltage
Static eliminator power unit
Power-off controller
Controlled components
Constant frequency AC output high voltage generation
Because the host of the elimination device uses AC constant frequency discharge, it can release the
positive and negative ions at the tip of the electrode needle connected to the electrostatic elimination
device, so as to avoid increasing static electricity due to the generation of positive or negative ions alone.
Through the high-voltage connection port of the host of the electrostatic elimination device, it can realize
a variety of combinations and multiple device connections, such as Electrode bar, Static eliminator-
air ionizer and air spray gun.
Discharge method-
Discharge
method-AC
The static elimination device uses
stable AC mains frequency as
electrode needle to convert positive
and negative ions
When the DC device provides high
voltage output at a certain pole, it will
cause voltage problems, and can only
release a single positive ion or negative
Positive and Negative electrode
Anti-static Eliminator (HD)
High voltage
contact 6mm
ground
The specifications of power unit (A series of H)
rameters Specifications / value remarks
types HD
Input V standard international voltage 220V/240V Customization
Output KV 5KV , 7KV , 9KV , 11KV , 12KV , 15KV Customization
power
20W 15W
consumption Monitoring at
Current 220V
60mA 30mA
consumption(mA)
HZ commercial
50/60HZ
frequency
operating ambient Too high
temperature and temperature or
humidity °C/%RH humidity is easy
0°C ~ +50°C ( 32°F ~ +122°F) , 35%~80%RH to cause insulation
problems
The total length maximum
6M 3M
of power unit usable length
fixed form baseboard baseboard
HV connection
HV output line , HV connection , HV terminal
form
trouble display *The alarm device
Flashes alarm Flashes alarm needs Additional
Flashes Flashes None None
production.
Weight( KG) 11 8/9.5 8/9.5 8/9.5 6.5 5
standards (mm) L
300*210*250 220*130*250 212*130*225 170*180*225 190*130*135 160*110*110
xWxH
assembly alarm buzzer, timer device, HV abnormal power-off controller, pressure filter, HV voltage connection box
Drive elimination
A series of Electrode bar, air gun and air ionizer (The power unit is a driving static elimination device)
device
maintenance Always keep away from locations where water, oils, flammable gas and solvents are present/ 1 month
procedure Keep clean and dry. clean with 75% alcohol
guarantee 1 year (not the human error)