0% found this document useful (0 votes)
29 views4 pages

Schneider Electric - EcoStruxure-Link150 - EGX150

The Link 150 is an Ethernet gateway with dual ports, supporting 24 V DC and PoE power supply, and is set to be discontinued on December 1, 2024, with end-of-service on September 30, 2025. It features various communication protocols including Modbus TCP/IP and RS232, and operates within a temperature range of -25 to 70 °C. The product is certified for multiple standards and is designed for industrial environments with a focus on sustainability.

Uploaded by

fayala.adel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views4 pages

Schneider Electric - EcoStruxure-Link150 - EGX150

The Link 150 is an Ethernet gateway with dual ports, supporting 24 V DC and PoE power supply, and is set to be discontinued on December 1, 2024, with end-of-service on September 30, 2025. It features various communication protocols including Modbus TCP/IP and RS232, and operates within a temperature range of -25 to 70 °C. The product is certified for multiple standards and is designed for industrial environments with a focus on sustainability.

Uploaded by

fayala.adel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Product datasheet

Specifications

Link 150 - ethernet gateway - 2


Ethernetport - 24 V DC and PoE
Local distributor code:
402718071 EGX150

notification_critical_stroke To be discontinued on: 1 Dec 2024

notification_critical_stroke To be end-of-service on: 30 Sept 2025

notification_critical_stroke To be discontinued
EAN Code: 3606480833458

Main
Range Enerlin'X

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product name Link

product or component type Gateway

Device short name Link150

device application Gateway

external supply External supply: 19.2...26.4 V DC, <500 mA

PoE Power supply device PoE conforming to IEEE 802.3af

Number of port 2

Communication gateway Ethernet/fieldbus

Complementary
Current consumption 130 mA at 24 V DC via external supply (20 °C)
65 mA at 48 V DC via PoE (20 °C)

Maximum power consumption in 15 W via PoE


W
Communication network type Ethernet, Ethernet Modbus TCP/IP daisy chain even/odd or none parity, at 10/100
Mbit/s
Ethernet, PoE 15W (Power over Ethernet) even/odd or none parity, at 10/100 Mbit/s
Ethernet, FTP even/odd or none parity, at 10/100 Mbit/s
Ethernet, HTTP even/odd or none parity, at 10/100 Mbit/s
Ethernet, SNMP even/odd or none parity, at 10/100 Mbit/s
Ethernet, Modbus TCP/IP even/odd or none parity, at 10/100 Mbit/s
RS232, Modbus RTU, JBUS, PowerLogic (SY/MAX) even/odd or none parity, at
2400, 4800, 9600, 19200 or 38400 bauds
RS232, Modbus ASCII even/odd or none parity, at 2400, 4800, 9600, 19200, 38400,
56000 or 57600 bauds
RS232, Modbus Serial line slave even/odd or none parity, at 2400, 4800, 9600,
19200 or 38400 bauds
RS485, Modbus RTU, JBUS, PowerLogic (SY/MAX) even/odd or none parity, at
2400, 4800, 9600, 19200 or 38400 bauds
RS485, Modbus ASCII even/odd or none parity, at 2400, 4800, 9600, 19200 or
38400 bauds
RS485, Modbus Serial line slave even/odd or none parity, at 2400, 4800, 9600,
19200 or 38400 bauds

Parity Even/odd or none

Communication port protocol Ethernet Modbus TCP/IP daisy chain, insulation 6 kV


Modbus TCP/IP, insulation 6 kV
Modbus RTU, JBUS, PowerLogic (SY/MAX), master - 2 or 4 wires, insulation 2.5 kV
Modbus ASCII, master - 2 or 4 wires, insulation 2.5 kV
Modbus RTU and ASCII, slave - 2 or 4 wires, insulation 2.5 kV

Communication port support RJ45: ETHERNET


RJ45: RS232
RJ45: RS485

14 Nov 2024 1
Number of inputs 0

Number of outputs 0

Connections - terminals Power supply: screw terminal block (top) 0.2…1.5 mm² cable(s) rigid
Power supply: screw terminal block (top) 0.2…1.5 mm² cable(s) flexible with cable
end
Power supply: screw terminal block (top) 0.2…1.5 mm² cable(s) flexible without cable
end

Tightening torque Power supply: 0.3 N.m flat screwdriver 3 mm

Wire stripping length Power supply: 7 mm for top connector connection

mounting mode Clip-on

mounting support 35 mm DIN rail

Product certifications cULus


FCC Class A
CE
RCM
UL
cUL

Standards IEC 60950-1


UL 61010-2-201
UL 61010-1
CSA C22.2 No 60950-1
AS/NZS 60950-1
UL 60950-1
IEC 61000-6-2

Depth 72 mm

Height 105 mm

Width 71 mm

net weight 175 g

Web services Web server

Local signalling LED: for Ethernet activity (ETH1)


LED: for Ethernet activity (ETH2)
LED: for module status
LED: for network communication status (Net Status)
LED: for communication (RS232)
LED: for communication (RS485)

compatibility code EGX150

Environment
Relative humidity 5…95 % at 55 °C without condensation

IP degree of protection IP40 (front panel (in enclosure))


IP30 (casing)
IP20 (terminal block)

Mechanical robustness Vibrations in operation: 1 Gn, 5 Hz...150 Hz conforming to IEC 60068-2-6


Vibrations de-energized: 1 Gn, 5 Hz...150 Hz conforming to IEC 60068-2-6
Shocks in operation: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks de-energized: 15 Gn for 11 ms conforming to IEC 60068-2-27
Jolts de-energized: 100 jolts/axle, 15 Gn for 6 ms conforming to IEC 60068-2-29
Free fall resistance: 1.2 m

2 14 Nov 2024
Electromagnetic compatibility Immunity for industrial environments conforming to EN 61000-6-2
Immunity for industrial environments conforming to CISPR 24
Conducted and radiated emissions conforming to FCC part 15 class B
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to CISPR 22
Electrostatic discharge - test level: 8 kV air, 6 kV contact B conforming to EN
61000-4-2
Radiated RF fields - test level: 10 V/m, 80 MHz...1 GHz A conforming to EN
61000-4-3
Radiated RF fields - test level: 3 V/m, 1 MHz...3 GHz A conforming to EN 61000-4-3
Fast transients immunity test level 4 conforming to EN 61000-4-4
Fast transient bursts class 3 conforming to EN 61000-4-12
Surges - test level: level 4 B (1.2/50 µs) conforming to EN 61000-4-5
Conducted RF disturbances - test level: 10 V conforming to EN 61000-4-6
Conducted RF disturbances conforming to CISPR 11
Magnetic field at power frequency - test level: 30 A/m class 5 conforming to EN
61000-4-8
Voltage dips and interruptions immunity test - test level: 100 %, 20 ms B conforming
to EN 61000-4-11
Voltage dips and interruptions immunity test - test level: 60 %, 200 ms B conforming
to EN 61000-4-11
Voltage dips and interruptions immunity test - test level: 30 %, 500 ms conforming to
EN 61000-4-11

Ambient air temperature for -25…70 °C


operation
Ambient air temperature for -40…85 °C
storage
Pollution degree 2

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 9.300 cm

Package 1 Width 9.000 cm

Package 1 Length 12.500 cm

Package 1 Weight 314.000 g

Unit Type of Package 2 S03

Number of Units in Package 2 24

Package 2 Height 30.000 cm

Package 2 Width 30.000 cm

Package 2 Length 40.000 cm

Package 2 Weight 8.278 kg

Unit Type of Package 3 P06

Number of Units in Package 3 192

Package 3 Height 75.000 cm

Package 3 Width 60.000 cm

Package 3 Length 80.000 cm

Package 3 Weight 72.000 kg

Contractual warranty
Warranty 18 months

14 Nov 2024 3
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-
class environmental performance. Green Premium promises compliance with the latest regulations,
transparency on environmental impacts, as well as circular and low-CO2 products.
Guide to assessing product sustainability is a white paper that clarifies global eco-label
standards and how to interpret environmental declarations.
Learn more about Green Premium arrow2_right
How we assess product sustainability arrow2_right

Transparency RoHS/REACh

Well-being performance

 Mercury Free

 Rohs Exemption Information Yes

Certifications & Standards


Reach Regulation REACh Declaration

Eu Rohs Directive Compliant with Exemptions

China Rohs Regulation China RoHS declaration

Environmental Disclosure Product Environmental Profile

Circularity Profile End of Life Information

4 14 Nov 2024

You might also like