0% found this document useful (0 votes)
18 views1 page

Report 1

KSB Limited issued a test certificate for three pumps supplied to Pooja Engineering Company, detailing the chemical and physical properties of various components, including the volute, casing, cover, impeller, and shaft. The certificate confirms compliance with material standards and includes results from visual inspections, hydro tests, and balancing tests, all of which were found acceptable. The hydro test was conducted with no leakage observed, and the impeller balancing was within acceptable limits.

Uploaded by

mvanbate88
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

Report 1

KSB Limited issued a test certificate for three pumps supplied to Pooja Engineering Company, detailing the chemical and physical properties of various components, including the volute, casing, cover, impeller, and shaft. The certificate confirms compliance with material standards and includes results from visual inspections, hydro tests, and balancing tests, all of which were found acceptable. The hydro test was conducted with no leakage observed, and the impeller balancing was within acceptable limits.

Uploaded by

mvanbate88
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

KSB Limited

Test Certificate
S.O.No. 0510127027/0300 Client POOJA ENGINEERING COMPANY
Pump Type ETN 050-032-125 CCSCP GA200302B Project
Qty. 3.000 P.O.No. PEC/STOCK-0920/2024
QN No. QN3270024 - P4 P.O.Date 25-06-2024

Material Test Certificate (2.2)


Chemical Properties (%) Physical Properties
Part Name Matl.Grade C Si Mn Cr Ni Mo S P UTS YS Elong RA HARD
Kg/mm2 Kg/mm2 ation % % (BHN)
VOLUTE ASTM A743 0.048 0.74 1.05 19.35 9.25 2.19 0.007 0.033 55.966 32.092 41.26 - 150
CASING CF8M
CASING ASTM A743 0.048 0.74 1.05 19.35 9.25 2.19 0.007 0.033 55.966 32.092 41.26 - 150
COVER CF8M
IMPELLER ASTM A743 0.048 0.74 1.05 19.35 9.25 2.19 0.007 0.033 55.966 32.092 41.26 - 150
CF8M
SHAFT ASTM A276 0.02 0.33 1.7 16.72 10.12 2.05 0.022 0.039 60.34 26.19 58 70.02 172
TYPE 316
SHAFT ASTM A276 0.02 0.33 1.7 16.72 10.12 2.05 0.022 0.039 60.34 26.19 58 70.02 172
SLEEVE TYPE 316

Remark : Chemical and/ or Physical properties indicated above are complying to respective material standard & grades.
Visual Inspection Certificate (2.1)
Visual inspection as per QN111004 (QN 10421Part-I & II) was carried out for above parts and found acceptable.

HydroTest Certificate (3.1) Balancing Test Certificate (2.1)


Hydro test as per QN1110011 (QN 10439) Impeller Qty. Balanced per Pump : 1
Part Name Part Code Qty./Pump Test Pressure
Kg/cm2 Impeller balancing done as per ISO 21940-11 GR.6.3
Volute Casing 102 1 21
and unbalance found within acceptable limit.
Casing Cover 161 1 21

Duration : 10 Min
Test Medium : Water at ambient temperature.
Remark : Found no leakage. Date : 30 Jun 2025

This is system generated certificate hence no signature required.