C A B L E T E R M I N AT I O N S
A2F-HTF
Ex db I/IIC, Ex eb I/IIC, Ex ta IIIC, Ex nR IIC
COMPRESSION GLAND for Single or Multi-Core Unarmored Heat Trace Cable
Features and Benefits
• Passes the IECEx / ATEX / UKEX 100% pull test, so no additional cable clamping is required.
• For indoor, outdoor, Group I, II, Ill, Zone 1, 2, 20, 21 and 22 hazardous areas.
• Fitted with a specially formulated elastomeric displacement seal, giving superior cable retention, explosion
protection, and an IP rating.
• Precision manufactured from high-quality brass (Marine Grade Electroless Nickel Plated™) available in aluminium 100%
or stainless steel 316/316L on request. (Note: Aluminium is not suitable for Group I applications.)
• Supplied with a thread-sealing gasket with parallel threads only.
Technical Data
Type: A2F-HTF
Gland Material: Brass (Marine Grade Electroless Nickel Plated™), Aluminium or
Stainless Steel 316/316L
Seal Material: Standard Thermoset Elastomer or Extreme Temperature Seals
Sealing Gasket Material: HDPE, Nylon 66 or PTFE
Cable Type: Single or Multi-Core Unarmoured Heat Trace
Sealing Area: Outer Sheath
Optional Accessories: Adaptor, Reducer, Earth Tag, Locknut, Serrated Washer and Shroud
Note: The installer should ensure that the materials are suitable for the
installation environment. C
Standards and Certifications
Equipment Protection Levels: IECEx/INMETRO: Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb,
Ex nR IIC Gc, Ex ta IIIC Da
ATEX/UKEX: #I M2 Ex db I Mb, Ex eb I Mb, # II 2/3 G 1D Ex db IIC Gb,
Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Continuous Operating Temp: Standard Seals:-60°C to +95°C /100°C (HDPE/ Nylon Sealing Gasket)
Extreme Temp. Seals: -60°C to +160°C (PTFE Sealing Gasket)
Conformance: Standard: Certificate:
IEC/BS EN IEC/BS EN 62444 CML 14CA364
IECEx IEC 60079 Part 0, 1, 7, 15, 31 IECEx TSA 23.0026
ATEX EN 60079 Part 0, 1, 7, 31 CML 20ATEX1026
EN 60079 Part 15 CML 22 ATEX 4116 The optional earth
D tag can be fitted
UKEX BS EN 60079 Part 0, 1, 7, 31 CML 21UKEX1013 between the cable
gland and the
BS EN 60079 Part 15 CML 22UKEX4117 sealing gasket.
INMETRO (Brazil) ABNT NBR IEC 60079 Part 0, 1, 7, 15, 31 TÜV 24.0267
SANS SANS/IEC 60079 Part 0, 1, 7, 15, 31 MASC S/20-9022
IP66/68 850m – Parallel IEC 60529 CML 15Y728
IP65/66 – Tapered IEC 60529
IP68 - Tapered and approved grease IEC 60529 IECEx TSA 23.0026
E
Deluge Protection DTS-01 CML 14CA370-2
Corrosion Protection ASTM B117-11, BS EN ISO 3231 EXOVA N968667
Cable Detail
Segurança
Exova
®
TÜVRheinland
TM
OCP 0004
Conditions for Safe Use - X
2024 © CCG CABLE TERMINATIONS (PTY) LTD
• None.
Gland Metric Entry Thread NPT Entry Thread Cable Detail
Maximum Hexagonal Detail Installation
Product
Size Min Min Min Max Min Max Length Max Max Torque
Code ‘C’ ‘C’
Reference ‘D’ ‘D’ ‘A’ ‘A’ ‘B’ ‘B’ ‘E’ ‘Flats’ ‘Crns’ Value Nm
0450-0 0-20s M20x1.5 15 ½/¾ 15 4.2 6.4 8.8 11.0 30.5 24.0 27.0 32.5
045001 1-20 M20x1.5 15 ½/¾ 15 4.2 8.0 10.9 14.0 36.0 27.0 30.0 32.5
045002 2-25 M25x1.5 15 ¾/1 15/19 4.8 7.0 13.7 16.0 36.0 35.0 39.0 47.5
All dimensions except NPT are in mm. Intermediate thread sizes are available on request. NPT threads should be tightened ‘wrench tight’.
CCG reserves the right to make alterations to the technical data, dimensions, designs and products available without notice. The illustrations cannot be considered binding. Please contact CCG for assistance. A2FHTF-GH051224E
FITTING INSTRUCTIONS
C A B L E T E R M I N AT I O N S
Metric Illustration
A2F-HTF COMPRESSION GLAND
ENCLOSURES AND EQUIPMENT TO WHICH CABLE GLANDS ARE FITTED:-
• Must be made from materials which are compatible with the cable gland materials. any mismatch).
• Have a sealing area around the cable gland entry point with a surface roughness • With a thread tolerance of metric class ‘6H’ or equivalent.
< Ra 6.3 µm. • Where the thread length is a minimum of 10mm for Ex d applications or 3mm for all
• Have entries that are perpendicular to the enclosure face in the area where the cable other applications
gland will seal to within 2.5°. OR CLEARANCE HOLES (not Ex d)
• Are sealed using the supplied sealing gasket (parallel threads) or by fully tightening • Where the hole size is the thread nominal size with a tolerance of +0.1 to +0.7mm.
into a threaded entry (tapered threads). Note that for tapered threads the IP rating can (e.g. the clearance hole for an M20 thread will have a diameter between 20.1mm and
be improved to IP68 with the use of a suitable thread sealant. 20.7mm).
MUST HAVE THREADED ENTRIES • Through material that is between 1mm and 12mm thick. (Thicker materials can be
• The same thread size as the cable gland. (Thread adapters should be used to correct accommodated using glands with extended entry threads.)
1. Measure the cable across its widest and narrowest dimensions to check for the correct fit.
If the gland has NPT entry threads fitted to a threaded
entry then IP68 (2m) can be achieved by applying one of
the following tested and approved grease types to the
thread:- Renolit Lubrene CA700 or LX220 EP2, Renolit
LC-WP2 or Moly LX2, or Dow Corning 4 Electrical
Compound.
2. To maintain IP66/68, ensure the gasket is in place.
Alternative installation through an unthreaded entry.
Locknut
Serrated Washer
3. Screw the inner into the apparatus. Tighten the inner to the installation
torque using a CCG Spanner . If the apparatus is untapped use a locknut.
4. Pass the cable end through the gland assembly.
5. Tighten the outer nut to the installation torque using a CCG Spanner to produce a seal and grip on the cable.
Tel: South Africa +27 11 3942020/1, Australia +1300 CABLE GLANDS (1300 222 534), Hong Kong +852 3427 2090,
Singapore +65 6 8421 002, South Korea +82 51 808 1161, United Kingdom +44 1 642 430346, United Arab Emirates +971 6 552 7781