0% found this document useful (0 votes)
123 views3 pages

EBSILON Component Library en

The document provides a comprehensive component library for EBSILON®Professional, detailing various components used in energy systems such as turbines, generators, heat exchangers, and control valves. It includes a wide range of equipment and their functionalities, emphasizing the importance of thorough testing and inspection by qualified experts. Additionally, it outlines the company's liability disclaimers and contact information for further inquiries.

Uploaded by

aisosanowamagbe7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views3 pages

EBSILON Component Library en

The document provides a comprehensive component library for EBSILON®Professional, detailing various components used in energy systems such as turbines, generators, heat exchangers, and control valves. It includes a wide range of equipment and their functionalities, emphasizing the importance of thorough testing and inspection by qualified experts. Additionally, it outlines the company's liability disclaimers and contact information for further inquiries.

Uploaded by

aisosanowamagbe7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

EBSILON®Professional

Component Library
1 2 3 4 5 6

Boundary Input Value Throttle Mixer with Throttle Splitter (mass defined) Steam Generator Steam Turbine
7 8 9 10 11 12

G
Steam Turbine Controller
Pump Feed Water Container Feed Water Preheater Generator (External Set Value)
Condenser
13 14 15 16 17 18

Splitter
Piping Control Valve Heat Extraction Heat Injection (w ith Characteristic) Splitter (% of Flow)

19 20 21 22 23 24

Fluid Bed Firing Combustion Chamber Gas Turbine


Drain Drum Compressor
or Combustion of a GT (Turbine only)

25 26 27 28 29 30
M
ECO / Evaporator / W ater Tank
Air Preheater Superheater Aftercooler Motor Difference Meter
(Mixing Point)

31 32 33 34 35 36

ETA=?

Power Summarizer Efficiency Meter Input of Value Expander Heat Consumer Value Transmitter

37 38 39 40 41 42

Controller
Mixer Water Injection (Internal Set Value) Gas Turbine Channel Burner Condensate Valve

43 44 45 46 47 48

Value Transmitter
Desuperheater Extraction Pump Value Indicator Measuring Point Cooling Tow er Sw itch

49 50 51 52 53 54

High Temp. Heat Selective Splitter Water Saturizer Drain of


Three Way Valve Coal Gasifier (Filter) of Gas Streams Gas Streams
Exchanger
55 56 57 58 59 60

Universal Steam Turbine Control Valve Mixer


Gas Turbine Nozzle Section
Heat Exchanger (ABB Type) (Fixed Press. Limit) (M3 or M1 % M2)
(ABB Type) Regulation
61 62 63 64 65 66
ProgDll

Feed Water Preheater


Heat Exchanger Feed Water Tank Programmable w ith Measurement
Duplex Heat Exchanger Debug Sw itch
(ABB Type) (ABB Type) Component Input
EBSILON®Professional
Component Library
67 68 69 70 71 72

Condenser with Control Valve Contr. (Ext. Set Value Evaporator GT w ith
Measurement Input (Ext. Press. Limit) and Switch) with Steam Drum Once Through Boiler Warranty Calculation

73 74 75 76 77 78
+

Heat Exchanger Block Heating Cooling Tower


ABB Reheat
(NEM Type) Pow er Plant Air Cooled Condenser Calculator w ith Char. Field
Gas Turbine
79 80 81 82 83 84
A
R
C
Pump
Fan Cooling Tow er Separator Pipe Coupling Fuel Cell w ith Characteristic Coal Dehumidifier

85 86 87 88 89 90
eta

Steam Generator Steam Generator


Electrostatic Efficiency Meter Steam Generator -
NOX Removal Main Heating surface Reaction Zone
Precipitator DIN 1942 Flue Gas Zone

91 92 93 94 95 96

Auxiliary
MSF Stage Kernel Scripting Compressor with char. Refomer Ext. Coal Gasifier
Heating Surface

97 98 99 100 101 102

Evaporator for Mixer with Specified


Extended Saturizer Separator for
Binary Mixtures Fluid Converter Fluid Reconverter Concentration
Binary Mixtures

103 104 105 106 107 108

Library Gas Turbine Steam Condensor


Absorber Rectifier OEM GT for Binary Mixtures Elementary Analyzer
Specificator

109 110 111 112 113 114


x3 1/1
Selective Splitter
Natural Draft Forced Draft Line Focussing
for Universal Fluid Mass Multiplier Distributing Header
Cooling Tow er Cooling Tower Solar Collector

115 116 117 118 119 120

1/1

Collecting Header Solar Field The Sun Direct Storage Indirect Storage Solar Tow er Receiver

121 122 123 124 125 126

Heat Exchanger w ith


Heat exchanger
Heliostat Field Steam Turbine SCC Shaft sealing Phase transition Diesel/Gas Motor
with storage
EBSILON®Professional
Component Library
127 128 129 130 131 132

Air cooled condenser hard coal mill lignite coal mill PID controller Transient separator Automatic connector
133 134 135 136 137 138

Control valve (KV) with Dynamic


Gibbs reactor Stack Emission display PV module piping
flow coefficient

139 140 141 142 143 144

Steam Generator Mixer with Wind Multi-Value


Splitter with
Wind data turbine transmitter
with two reheats three outlets three inlets

145 146 147 148 149 150


Energy Services GmbH 2021, v1_10/21

Stratified
storage
Gearbox Limiter Admission Extraction Connecting pipe

151 152 153 154 155 156


Evaporative Electric
Cooler chiller G

Steam Jet
Reciprocating engine Vacuum Pump Transformer Power Converter

157 158 159 160 161 162


Phase-
© STEAG

Splitter
(TREND) Compressor Storage for Injection with
Battery (map based) compressible fluids temperature control Electric boiler

This information and all further technical advice is based on our present knowledge and
experience. However, it implies no liability or other legal responsibility on our part
including with regard to existing third party intellectual property rights, especially patent
rights. In particular, no warranty, whether express or implied, or guarantee of product
properties in the legal sense is intended or implied. We reserve the right to make any
changes according to technological progress or further developments. The customer is
not released from the obligation to conduct careful inspection and testing of incoming
goods. Performance of the product described herein should be verified by testing, which
should be carried out only by qualified experts in the sole responsibility of a customer.
Reference to trade names used by other companies is neither a recommendation, nor
does it imply that similar products could not be used.

Contact person:
STEAG Energy Services GmbH
Detlef Günzel
Wetzbach 35
64673 Zwingenberg (Germany)
P +49 6251 1059-15
[email protected] steag-systemtechnologies.com

You might also like