4P359542-3M
Wireless LAN Connecting Adapter
<BRP069A45>
Installation Manual
Wireless LAN Connecting Adapter
<BRP069A45>
Installation Manual
Homepage: http://www.onlinecontroller.daikineurope.com
For details on specifications, installation instructions,
setting methods, FAQ, copy of the original declaration
of conformity and the latest version of this manual,
see the above homepage.
Hereby, Daikin Industries Czech Republic s.r.o., declares that the
BRP069A41 is in compliance with the essential requirements and
other relevant provisions of directive 1999/5/EC.
Accessories
Check if the following accessories are included in your package.
※1 Affix to the seal attachment on the back face of this sheet and store in a safe place.
(A) Wireless LAN (B) Serial number seal (C) Installation manual
connecting adapter (1 sheet) ※1 (1pc)
BRP069A41
(D) Wire
harness
English 1
Safety precautions
The following describes the meanings of pictorial symbols used in this
documentation.
Give this installation manual to the customer when installation is
completed.
To conduct a test run of the air conditioner, follow the installation
manual for the air conditioner unit.
The protection of appliances marked with this symbol is
ensured by double insulation and does not require a safety
connection to electrical earth (ground).
Prohibited Follow directions
Warning Situations which could result in
death or serious injury.
When installing:
equest installation by your dealer or a technician.
R
(Can cause electric shock or fire.)
Always use the accessories and specified parts for
installation. Be sure to follow the directions in this
installation manual.
(Can cause the unit to fall, electric shock or fire.)
Electrical work should be carried out in accordance with the
installation manual and the national electrical wiring rules or
code of practice.
Always turn off the power supply when installing.
(Touching the electrical parts can cause an electric shock.)
The main switch of the installation is at the outdoor unit.
Please switch off this main switch to turn off the power
supply.
English 2
Safety precautions
Warning Situations which could result in
death or serious injury.
When using:
o not disassemble, modify, or repair.
D
(Can cause fire, electric shock or injury.)
Do not handle this product with wet hands.
(Can cause electric shock or fire.)
Do not allow this product to get wet or use it when bathing
or doing similar activities with water.
(Can cause electric shock or fire.)
Do not use this product near medical equipment or persons
using cardiac pacemakers or defibrillators. This product may
cause life-threatening electromagnetic interference.
Do not use this product near auto-control equipment such as
automatic doors or fire alarm equipment.
(Can cause accidents due to erroneous equipment behavior.)
Immediately disconnect the air conditioner power plug if
there is abnormal odor or sound, when it is overheating,
or smoking.
(Can cause fire or malfunction.)
Request an inspection by your dealer.
Disconnect the air conditioner power plug if the product
was dropped or the case is damaged.
(Can cause fire or electric shock)
Request an inspection by your dealer.
English 3
Safety precautions
Caution Situations which could result in
damage or physical injury.
When installing:
Do not install where flammable gas leaks can occur.
(Can cause fire.)
Grip the connector when disconnecting the connecting
cord.
(Otherwise fire or electric shock can occur.)
When using:
Do not use where small children can get access.
(Can cause injuries.)
Do not use this product near a microwave oven.
(This can affect Wireless LAN communications.)
English 4
Disposal requirements
Your product is marked with this symbol. This symbol
means that electrical and electronic products shall not be
mixed with unsorted household waste.
Do not try to dismantle the system yourself: the dismantling
of the product and of other parts must be done by a
qualified installer in accordance with relevant local and
national legislation.
Product and waste must be treated at a specialized trea-
tment facility for re-use, recycling and recovery.
By ensuring correct disposal, you will help to prevent
potential negative consequences for the environment and
human health. Please contact the installer or local authority
for more information.
English 5
Main components
Wireless LAN connecting adapter
POWER lamp
(green) lights when
running. SETUP button
Use when
connecting to a
router (Wireless
RUN lamp (orange)
LAN access point).
lights when
connecting to
a router (Wireless
LAN access point).
MODE button
switches modes
(RUN/AP) when
AP lamp (yellow) held down.
lights when
connected directly to
a smart phone.
Applicable indoor unit
FTX20-71K2
ATX20-35K2 Wireless LAN connection
FTX50-71KM adapter (the product is inside
FTXP20-35K the indoor unit)
ATXP20-35K
If your indoor unit is not mentioned in the list above,
refer to http://www.onlinecontroller.daikineurope.com
for the latest applicable indoor units.
English 6
Installation Installation
Work
1 Attach the Wireless LAN connection adapter to
indoor unit. Danger
■■BRP069A41 Always turn off the power supply when installing.
(Touching the electrical parts can cause
Refer to your air conditioner‘s an electric shock.) The main switch of the
installation is at the outdoor unit.
installation manual for details on
connecting to an HA system with
wire harness (D). Wire harness (D)
PCB Wireless LAN
connecting
adapter
Set wire harness as shown (1), and attach front grille, grab wire harness
and pull it out, then set wire harness as shown (2) and attach service cover.
English 7
Installation Installation
Work
2 Remove the adapter case (upper).
■■BRP069A41
Press a regular screwdriver into the dent between the upper and lower
cases to remove. (Be careful not to damage the case.)
Regular screwdriver
Adapter
case (upper)
Wireless LAN Adapter
connecting adapter case (lower)
printed circuit board
English 8
Installation Installation
Work
3 Attach connecting cord to the product.
■■BRP069A41
Attach the connecting cord connector (white).
Fasten the connecting cord to the notch in the adapter case (lower).
Connect the connector to the same color.
Connector (white)
Fasten the connecting cord and ensure
that external force is not transmitted.
English 9
Installation Installation
Work
4 Return the adapter case to its original state.
■■BRP069A41
Snap the top of the upper case
unto the clip at the top of the
lower case and press to close
the box.
Adapter case Adapter case
(lower) top (upper) top
portion clip portion clip
Check that the
connecting cord is
securely fastened.
Push until you
hear a click.
5 Inserting Wireless LAN connection adapter to
indoor unit.
■■BRP069A41
Grab the adapter case with your fingers, insert it back into the indoor
unit and close the door. (See picture on the next page)
English 10
Installation Installation
Work
Class 15-35
• Place the wireless adapter against the hooks (1).
• Lock the adapter by pressing it down (2).
(1) (2)
Class 50-71
• Place the wireless adapter into the holder (1).
• Fix the adapter in the holder by pressing down on it (2).
(1) (2)
English 11
Installation Installation
Work
6 Functionality Check
■■BRP069A41
Turn on the power supply and check that the [POWER] lamp for the product
lights..
When turning on the
power, always attach
the adapter case (top).
English 12
Configuration Connection
Settings
Section
The customer is responsible for providing the following.
□□Smartphone or tablet PC
(Supported OS: Android 2.3.3 or later; iOS 5.0 or later.)
□□Internet line and communicating device
(Modem/router or similar device)
□□Wireless LAN access point
□□[Daikin online controller] (No cost)
Installation method of Daikin online controller
For Android Phones For iPhones
(1) Open the [Google Play]. (1) Open the [App Store].
(2) Search for [Daikin online (2) Search for [Daikin online
controller]. controller].
(3) Follow the directions on the (3) Follow the directions on the
screen to install. screen to install.
Refer to
http://www.onlinecontroller.daikineurope.com
for detailed installation instructions.
English 13
Troubleshooting
The following table provides brief descriptions of how to handle trouble or
uncertainties when you install the product or make connection settings.
Refer to the FAQ on the homepage for more details.
When this happens Explanation and where to check
None of the LEDs light → Try to operate the unit with the
infrared remote controller.
→ Turn off the air conditioner
and restart it.
→ Make sure the LEDs are not
disabled in the application.
→ Check the installation
The WLAN adapter → Check that the power is on.
is not visible on the → Check that the RUN LED is lit.
unit overview screen → If the AP LED is lit, press the MODE
("Home" screen) after button for two seconds to switch to
the WLAN adapter has RUN mode.
been configured. → If the RUN LED is blinking, retry to
connect the WLAN adapter to the
wireless network.
Make sure the WLAN adapter is
close enough to the router (wireless
LAN access point).
→ If the RUN LED is lit, make sure
that the smartphone or tablet is
connected to the same wireless LAN
network as the WLAN adapter.
English 14
Troubleshooting
When this happens Explanation and where to check
When trying to make → If the AP LED is not lit, press the
a direct connection to "Mode" button for 2 seconds to
the adapter (AP mode) switch to AP mode.
the WLAN adapter is not → If the AP LED is blinking, please wait
visible in the available until the AP LED is lit (approximately
Wi-Fi networks list of 1 minute). The WLAN adapter is still
the phone/tablet starting up.
→ If the AP LED is lit, switch to RUN
mode by pressing the MODE button
for two seconds. Now switch back
to AP mode by pressing the MODE
button again for two seconds. This
changes the wireless channel
on which the WLAN adapter
is operating.
Repeat if necessary.
None of the above work →R
efer to the FAQ on:
http://www.onlinecontroller.
daikineurope.com