Drawing Number-5 MW SLD - Dhorwasa - WCL-SLD

The document outlines specifications for a 23.0MW AC / 32.2 MW DC grid-connected solar power plant, including requirements for numerical relays, cable sizing calculations, and inverter protection details. It emphasizes the need for RS 485 communication for various equipment and mandates compliance with government regulations for metering. Additionally, it notes that inverter power will be clipped to a maximum of 5.0MW AC during detailed design.

Uploaded by

Kashif Naiyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
308 views1 page

Drawing Number-5 MW SLD - Dhorwasa - WCL-SLD

The document outlines specifications for a 23.0MW AC / 32.2 MW DC grid-connected solar power plant, including requirements for numerical relays, cable sizing calculations, and inverter protection details. It emphasizes the need for RS 485 communication for various equipment and mandates compliance with government regulations for metering. Additionally, it notes that inverter power will be clipped to a maximum of 5.0MW AC during detailed design.

Uploaded by

Kashif Naiyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTE:-

1. ALL NUMERICAL RELAYS & MFM OF 11KV SWITCHGEAR


SURGE/LIGHTNING ARRESTER
SHALL BE WITH RS 485 PORT FOR MODBUS COMMUNICATION .
2. LT CABLE SIZING CALCULATION SHALL BE SUBMITTED
ISOLATOR
SEPARATELY.
CURRENT TRANSFORMER 3. AUX TRAFO SIZING CALCULATION SHALL BE PROVIDED IN
AUX SLD.
VOLTAGE TRANSFORMER
4. CONNECTION FROM LT PANEL TO TRANSFORMER WILL BE
VSS VOLTMETER SELECTOR SWITCH THROUGH CABLE.
V VOLTMETER 5. EQUIPMENT INTERCONNECTION WITHIN THE LT PANEL
SHALL BE AS PER STANDARD OFFERING OF OEM.
33 kV VCB
6. NUMERICAL RELAYS & PROTECTION FUNCTIONS SHALL BE
AS PER OEM DESIGN AND THE COMMUNICATION SHALL BE AS
TO NAVIN KUNADA
ACDB PER RS485 COMMUNICATION PROTOCOL.
SUBSTATION
AC
7. METERING SHALL BE AS PER GOVT. REGULATIONS.
DC
350 kVA STRING INVERTER
8. ALL THE CABLE SIZING INCLUDING SOLAR CABLE &
SOLAR TRANSFORMER AUXILIARY TRANSFORMER RATINGS ARE INDICATIVE AND
SHALL BE UPDATED AS PER APPROVED SIZING CALCULATION.
PLANT SIDE
2 POLE STRUCTURE
9. INVERTERS POWER WILL BE CLIPPED AS PER 5.0MW AC
CAPACITY DURING DETAILED DESIGNING.

INVERTER PROTECTION DETAILS


50 Instantaneous Overcurrent Relay S.NO. DESCRIPTION AVAILABILITY

50N Neutral Instantaneous Overcurrent 1. DC INPUT PROTECTION YES

51 Ac Time Overcurrent Relay 2. OUTPUT PROTECTION YES

51N 3. SURGE PROTECTION DC TYPE I+ II/AC TYPE II


Neutral Time Overcurrent

4. GRID MONITORING YES


80 Liquid or Gas Flow Relay
5. OVERVOLTAGE PROTECTION YES

33kV ICOG HT PANEL 86 MASTER TRIP RELAY 6. INSULATION MONITORING YES


LOC : MCR AT DHORWASA 7. Q AT NIGHT FUNCTION YES
94 ANTI-PUMPING
INDOOR PANEL 8. EARTH FAULT PROTECTION YES

95 TRIP CIRCUIT SUPERVISION

Pressure Switch Detector


63X Transformer Fault Protection

27 UNDER VOLTAGE

59 OVER VOLTAGE

59N NEUTRAL DISPLACEMENT

49 T/F THERMAL OVERLOAD PROTECTION

33 kV, 630A, 50Hz,


25kA for 1 Sec, Al Bus Bar

AC:DC RATIO - 1:1.40

00 21.03.25 FOR APPROVAL

5.5 MVA IDT REV. DATE REVISION HISTORY


PROJECT TITLE :
SPARE 23.0MW AC / 32.2 MW DC GRID CONNECTED SOLAR
POWER PLANT AT MAJRI AREA CHANDRAPUR,
PLANT SIDE
MAHARASTRA, INDIA
2 POLE STRUCTURE

DEVELOPER :
WESTERN COALFIELDS LIMITED
(A Subsidiary of Coal India Limited)

FROM DHORWASA EPC CONTRACTOR:


AC Distribution Board AC Distribution Board
SUBSTATION SURYAM INTERNATIONAL
Capacity :2500 Amps @0.8kV Capacity :2500 Amps @0.8kV

PRIVATE LIMITED
PROJECT CODE:
SIPL-AZS-MAJ
DRAWING TITLE:
String Inverter String Inverter String Inverter String Inverter String Inverter
INVERTER-1
STRING

INVERTER-1
STRING

AC Capacity: 300 KW @51°C AC Capacity: 300 KW @51°C AC Capacity: 300 KW @51°C AC Capacity: 300 KW @51°C AC Capacity: 300 KW @51°C
Total No. of String: 25 Nos. Total No. of String: 25 Nos. Total No. of String: 25 Nos. Total No. of String: 25 Nos. Total No. of String: 24 Nos.
Total No. of Modules: 700 Nos. Total No. of Modules: 700 Nos. Total No. of Modules: 700 Nos. Total No. of Modules: 700 Nos. Total No. of Modules: 672 Nos.
MPPT-16 MPPT-16 MPPT-16 MPPT-16 MPPT-16

String 1 to 25 String 1 to 25 String 1 to 25 String 1 to 25 String 1 to 24

+VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE +VE -VE

SINGLE LINE DIAGRAM - SLD


01
01

01
01

01

01
01

01
01

01

01
01

01
01

01

01
01

01
01

01

01
01

01
01
02
02

02
02

02

02
02

02
02

02

02
02

02
02

02

02
02

02
02

02

02
02

02
02
27
27

27
27

27

27
27

27
27

27

27
27

27
27

27

27
27

27
27

27

27
27

27
27
28
28

28
28

28

28
28

28
28

28

28
28

28
28

28

28
28

28
28

28

28
28

28
28
STRING 24

STRING 25

STRING 24

STRING 25

STRING 24

STRING 25

STRING 24

STRING 25

STRING 24
STRING 21

STRING 21

STRING 21

STRING 21

STRING 21
STRING 2

STRING 2

STRING 2

STRING 2

STRING 2
STRING 1

STRING 1

STRING 1

STRING 1

STRING 1

DRAWING NO. : SIPL-AZS-MAJ-SLD-E-002


SITE CO-ORDINATE.: 20° 4' 4.86"N-79° 4' 51.48"E

SHEET NO. 1 OF 1 SCALE N.T.S.


DRAWN PB PAPER SIZE A0
CHECKED PP REV NO. R0
APPROVED AKS DATE 21.03.25
RELEASED FOR PRELIMINARY TENDER APPROVAL CONSTRUCTION