Mega Electrical Panel Ferrule Code Chart (150+ Codes)
Ferrule Code Full Description
L1 Line 1 (Phase 1)
L2 Line 2 (Phase 2)
L3 Line 3 (Phase 3)
N Neutral
E Earth
PE Protective Earth
R Red Phase
Y Yellow Phase
B Blue Phase
T1 Motor Output Phase 1
T2 Motor Output Phase 2
T3 Motor Output Phase 3
M1 Motor Wire 1
M2 Motor Wire 2
M3 Motor Wire 3
C1 Control Wire 1
C2 Control Wire 2
C3 Control Wire 3
C4 Control Wire 4
S1 Sensor Input 1
S2 Sensor Input 2
A1 Relay/Contactor Coil Terminal A1
A2 Relay/Contactor Coil Terminal A2
13 NO (Normally Open) Contact
14 NO (Normally Open) Contact Return
11 NC (Normally Closed) Contact
12 NC (Normally Closed) Contact Return
24V 24V DC Supply
230V 230V AC Supply
+24V DC Positive
0V DC Negative
OL1 Overload Relay Connection 1
OL2 Overload Relay Connection 2
FR Forward Control Signal
REV Reverse Control Signal
PB1 Push Button 1
PB2 Push Button 2
TB1 Terminal Block 1
TB2 Terminal Block 2
KM1 Contactor 1
KM2 Contactor 2
Q1 MCB or Breaker 1
Q2 MCB or Breaker 2
TR Transformer
CT Current Transformer
VT Voltage Transformer
B1 Buzzer 1
B2 Buzzer 2
H1 Hooter 1
H2 Hooter 2
IND Indicator Lamp
PLC-I01 PLC Digital Input 1
PLC-O01 PLC Digital Output 1
PLC-I02 PLC Digital Input 2
PLC-O02 PLC Digital Output 2
PLC-I03 PLC Digital Input 3
PLC-I04 PLC Digital Input 4
PLC-I05 PLC Digital Input 5
PLC-O03 PLC Digital Output 3
PLC-O04 PLC Digital Output 4
PLC-O05 PLC Digital Output 5
LS1 Limit Switch 1
LS2 Limit Switch 2
F1 Fuse 1
F2 Fuse 2
NO1 Normally Open Contact 1
NC1 Normally Closed Contact 1
X1 Intermediate Relay Terminal X1
X2 Intermediate Relay Terminal X2
Y1 Relay Coil Y1
Y2 Relay Coil Y2
HMI-PWR HMI Power Supply
HMI-TX HMI Transmit Line
HMI-RX HMI Receive Line
SCADA-IN1 SCADA Input 1
SCADA-OUT1 SCADA Output 1
ALM1 Alarm Signal 1
ALM2 Alarm Signal 2
BAT+ Battery Positive
BAT- Battery Negative
GEN-START Generator Start Signal
GEN-STOP Generator Stop Signal
ATS-IN Automatic Transfer Switch Input
ATS-OUT Automatic Transfer Switch Output
DG-CTRL DG Control Signal
DG-STAT DG Status Signal
SPD1 Surge Protection Device Line 1
SPD2 Surge Protection Device Line 2
AI1 Analog Input 1
AI2 Analog Input 2
AO1 Analog Output 1
AO2 Analog Output 2
DI1 Digital Input 1
DI2 Digital Input 2
DO1 Digital Output 1
DO2 Digital Output 2
ETH-TX Ethernet Transmit
ETH-RX Ethernet Receive
UPS-IN UPS Input
UPS-OUT UPS Output
TEMP-IN Temperature Sensor Input
PRESS-IN Pressure Sensor Input
FREQ-IN Frequency Signal Input
SPD-ALM Surge Protection Alarm
GND Ground
CAN-H CAN Bus High
CAN-L CAN Bus Low
RS485-A RS485 Line A
RS485-B RS485 Line B
VFD-IN1 VFD Input Signal 1
VFD-OUT1 VFD Output Signal 1
VFD-EN VFD Enable
VFD-FR VFD Forward
VFD-RV VFD Reverse
ENC-A Encoder A Phase
ENC-B Encoder B Phase
ENC-Z Encoder Zero Pulse
I1+ Current Signal +
I1- Current Signal -
V1+ Voltage Signal +
V1- Voltage Signal -
SMPS-IN SMPS Input
SMPS-OUT SMPS Output
FAN1 Cooling Fan 1
FAN2 Cooling Fan 2
FLT1 Fault Indicator 1
FLT2 Fault Indicator 2
INTLK1 Interlock Signal 1
INTLK2 Interlock Signal 2
REMOTE Remote Start/Stop
LOCAL Local Start/Stop
PUMP1 Pump Control 1
PUMP2 Pump Control 2
SOL1 Solenoid Valve 1
SOL2 Solenoid Valve 2
IGN Ignition Signal
OIL-LVL Oil Level Sensor
TEMP-HI High Temperature Alarm