2399 0062 04 Diagrams and Drawings
2399 0062 04 Diagrams and Drawings
DM75D
No. CNN006204
Rev. 001 |
© Copyright 2024, Epiroc Drilling Solutions LLC, USA
Any unauthorized use or copying of the contents or any part thereof is prohibited.
This applies in particular to trademarks, model denominations, part numbers and drawings.
Table of Content
Electrical Diagram................................................................................................5
D.C. SCHEMATIC / .................................................................................................................6
SCHEMATIC, ELEC / ........................................................................................................... 25
RCS LITE SCHEMA / ........................................................................................................... 26
Hydraulic Diagram............................................................................................. 33
HYDRAULIC SCHEM / .........................................................................................................34
3
4
Electrical Diagram
LIST OF CONTENTS
Part no Description Remarks Page
2310030526 D.C. SCHEMATIC 6 - 24
2310034072 SCHEMATIC, ELEC 25
2310133078 RCS LITE SCHEMA 26 - 31
5
1 2 3 4 5 6 7 8 9 10
8241
004 ALL 507
8 SPOOL VALVE, 10 SPOOL VALVE UPDATED 15.11.06 LLG JZ
SHT-2
1. ENGINE SHUT DOWN CIRCUIT UPDATED.
SHT-3 2. PROPEL JOYSTICKS WIRING UPDATED.
SHT-4 USS19
006 SHT-5 00162
3.
4.
JACK WIRING UPDATED.
TRAM SPEED CONTROL ADDED.
19.02.22 LLG JZ
PROHEAT
COOLANT
SHT-8 00215 DELETE NOTE 14 &15.
ENGINE
HEATER
USS21
008 SHT2-E9
01113
THROTTLE WIRES FOR CUMMINS UPDATED. 21.08.09 EW JC
MICROWAVE OVEN
PCM
TIMER
ALTERNATOR
(OPTION)
CABISIDE
)
STARTER
NON-CAB
STARTER
100 AMP
SIDE
(
5
C
S2
S4
M
M
DISCONNECT
ALT
BATTERY
S2
S4
POWER SOURCE FOR
12 VDC OPTIONS
TO SH12,
FUSIBLE
VANNER EQUALIZER
LINKS
C-3
P2
SIDE OF DRILL
20A BATTERY SAME
AS EQUALIZER
35A
35B
N1
8 AWG
8 AWG
LOCATED AT
D
BATTERY JUMP START
+12 V GRND
14 AWG
-
-
12 V
12 V
MICRO
WAVE
CONNECTION
-
(OPTION)
7
S1
V2
S3
+
15 A
CB#5
-
+24 V
12 V
12 V
+
KEY SWITCH
6
POSITIVE CONNECTION POST
ON
10A
20A
P1
FUSIBLE LINKS
OFF
V1
E
242B
8 AWG
ON NCS STARTER
1
1
P2
CB #6, #7
TO SH 12
FUSE
30A
8 AWG
2
242A
F
10 AWG
NOTES:
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000 ANGULARITY
1. " "
ANGLES 0 30' MFG. APPVL.
CONFIDENTIAL OR TRADE SECRET INFORMATION
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
CONCENTRICITY
SCALE 1.000 COMM.
NO. 2310030526 SH 1 OF 19
6
1 2 3 4 5 6 7 8 9 10
QSK 19 TIER 2
UNSWITCHED GROUND
UNSWITCHED POWER
ENGINE SHUTDOWN
KEYSWITCH INPUT
AIR TEMPERATURE
AIR TEMPERATURE
STARTER RELAY NCS
)
ETHER CONTROL
STARTER RELAY CS
)
START INTERLOCK
NEUTRAL START
NEUTRAL START
DIAGNOSTIC
DIAGNOSTIC
DATA LINK
THROTTLE
B
FUEL GAUGE
CONTROL
(
INTERLOCK
INTERLOCK
CIRCUIT
(
TO ECM
TO ECM
SWITCH
ENGINE
LIGHTS
SENDER
J1939
GAUGE
RELAY
(
5
5
31 PIN ENGINE
5
5
5
23 PIN ENGINE
16 PIN ENGINE
ES
SERVICE TOOL
3 PIN J1939
CONNECTOR
CONNECTOR
CONNECTOR
ON ENGINE
C
CONNECTOR
COMPRESSOR DISCHARGE
20
21
22
01
24
17
18
23
08
C
B
16
A
TEMPERATURE SENDER
X
W
F
K
L
C
A
H
200
100
200
100
04E
03E
18E
02E
23E
01E
21E
16E
20E
22E
08E
X
W
38E
EMERGENCY
OHM
120
C
(OPTION)
DIAGNOSTIC INCREMENT
TACHOMETER
ANSUL
2657409104
STOP
FIRE
DIAGNOSTIC SWITCH
S1
S3
ENGINE
MAINTENANCE LAMP
ENGINE STOP LAMP
THROTTLE RETURN
SENDER UNIT
12
THROTTLE SIGNAL
HYD. TO CERTIQ HARNESS HLA
A
34
25
16
1
THROTTLE +5V
36E
(OPTIONAL)
VOLTMETER
R23
NEUTRAL DETECT FEED
R7
R8
R9
ENGINE
34
25
16
B
A
34
25
16
7F
20
(SH 6, C-5)
7
5
LVL.
-
(SH 6, B-8)
89
-
7
8
A
B
C
2.5 K
2.5 K
2.5 K
THROTTLE HARNESS
OPTION PRELUBE
36D
B
Y
R
+
307
ENGINE OIL
2654651187
OR
90
+
PRESSURE
(TO PRELUBE
B
34
25
16
TIMER/SOL)
DIAGNOSTIC SCROLL
248 F
DISCH
DIAGNOSTIC SWITCH
TEMP
2658337417
A
34
25
16
19
YLW
337
6
5
1
36C
B
34
25
16
9
RED BLK
EMERGENCY
R8A
DC SIDE
START
(SH 6, C-3)
34
25
16
A
STOP
FUEL GAUGE
BLU
ROTATION
(DIAGNOSTICS)
NEUTRAL
C
A
B
DETECT
17
POWERVIEW
36B
F
A
C
E
D
POWER +24V
(RESISTOR INCLUDED)
COMPRESSOR DISCHARGE
HARNESS 2657760555
MODULE
EMERGENCY
MURPHY POWERVIEW
CAB SIDE
R7A
GROUND
TEMPERATURE GAUGE
R9A
STOP
5
89
36A
THROTTLE CONTROLLER
B C A 2657678088
DIRECT
CAN HI
2657409096
CAN LO
CAN SHLD
EMERGENCY
CONNECT
STOP IN
CONSOLE
TERMINATION
TO
BATTERIES
RESISTOR
36
2658337361
CONNECTOR
DATA LINK
CB#1
5 A
A
E
B
D
9 PIN
7
7
7
7
6 7
6
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE
UNSPECIFIED TOLERANCES CHARACTERISTIC SYMBOL O 1in DRAWN BY NH
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
7
1 2 3 4 5 6 7 8 9 10
EMERGENCY SHUTDOWN
STARTER RELAY NCS
(STANDARD E-STOP
STARTER RELAY CS
MURPHY POWERVIEW
BATTERY NEGATIVE
START INTERLOCK
AIR TEMPERATURE
ENGINE THROTTLE
ENGINE SHUTDOWN
AIR TEMPERATURE
SWITCHED POWER
UNSWITCH POWER
NEUTRAL START
NEUTRAL START
COOLANT LEVEL
J1939 AND CAT
FUEL GAUGE
INTERLOCK
INTERLOCK
STRING)
CONTROL
SENSOR
TO ECM
RELAY
SENDER
GAUGE
B
5
5
5
5
5
5
5
5
5
5
5
5
5
5
120
OHM
ENERGIZE TO RUN
R19
16
44E
B
S1
S3
TACHOMETER
ENGINE
70E
42E
08E
09E
55E
34E
50E
66E
04E
49E
05E
61E
63E
65E
48E
52E
53E
69E
44E
ENGINE
ECM
1
16
34
25
A
SENDER UNIT
42E
08E
09E
34E
50E
66E
70E
TERMINATION
36F
COMPRESSOR DISCHARGE
RESISTOR
R7
R8
R9
SUPPRESSION
TEMPERATURE SENDER
UNSWITCHED BATTERY +24V
(OPTION)
FIRE
C
5
ENGINE VOLTMETER
120
OHM
NEUTRAL DETECT FEED
25
16
34
B
20
2657409104
36E
12
COOLANT LEVEL SIGNAL
COOLANT LEVEL RETURN
(OPTIONAL)
R23
COOLANT LEVEL +8V
25
16
34
A
(SH 6, C-5)
THROTTLE SIGNAL
90
SWITCHED POWER
0X
89
OR
OPTION PRELUBE
100E
100E
(TO PRELUBE
TIMER/SOL)
ENGINE COOLANT
7F
J1939 DATA LINK (-)
J1939 DATA LINK (+)
25
34
16
36D
B
INLINE
INLINE
90
TEMPERATURE
FUSE
FUSE
15A
15A
8
337
WH
HYD.
LVL.
19
34
25
16
A
SW.
D
HARNESS (2657760555)
(RESISTOR INCLUDED)
9
DIRECT CONNECT
TO BATTERIES
5 BLK
7 GRN
TO BATTERIES
R8A
MURPHY POWERVIEW
START
7
TEMPERATURE
DISCHARGE
248 F
(SH 6, C-3)
O
ENGINE OIL
FUEL GAUGE
ROTATION
A
C
B
25
34
16
B
17
NEUTRAL
PRESSURE
DETECT
YLW
36C
25
A
16
34
R7A
R9A
RED BLK
89
GROUND LVL
NCS/DE
BLU
SIGNAL
RETURN
TO SH 13,E-6
+24V
10
11
1 12
B
POWERVIEW
36B
THROTTLE CONTROLLER
E
2
3
GROUND LVL
COMPRESSOR DISCHARGE
MODULE
CS/NDE
C
B
6
TEMPERATURE GAUGE
25
A
16
34
(2658316897)
1
TERMINATION
36A
RESISTOR
2657409096
A
B
C
D
E
F
G
CAN HI
B C A
CONSOLE
CAN LO
CAB
CAN SHLD
7
7
7
7
7
7
7
7
7
7
(2657678088)
36
DATA LINK
CONNECTOR
9 PIN
CB#1
5A
F
6
6
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
8
1 2 3 4 5 6 7 8 9 10
)
A
(
(
)
(
FEMA
(
STROBE LIGHT ON PLATFORM REAR
(OPTION)
STROBE LIGHT ON CAB (OPTION)
,
,
LIMIT SWITCH(OUT)
B
CENTER LOCKING)
CENTER LOCKING)
CAROUSEL STOWED
SOLENOID VALVE
PULLDOWN FORCE
ROTARY HEAD UP
PROPEL SELECT
FEMA ACTUATOR
PROPEL DRILL
ROD SUPPORT
PROPEL ALARM
PROPEL MODE
PROPEL MODE
PROPEL MODE
DRILL FEED
MAIN PUMP
MAIN PUMP
(NO BUMP)
CAROUSEL
INDEXING
D.C.SIDE
CAB SIDE
CONTROL
PULLDOWN
RELAYS
LIMIT
FORCE
CCW
ROD
AUTO
AUTO
CW
5
10
10
5
8
SV
R5
LOCKING
D4
R6
G
Y
LOCKING
G
Y
D5
RETURN
HANDLE
CENTER
SPRING
RETURN
HANDLE
CENTER
SPRING
70B
2310113583, SECT 6
70B
70B
+
X
2310113583, SECT 4
-
A
+
B
A
B
-
70B
DPV
DPV
C1 DN/F'WD C
UP/B'WD
C1
C1
C2
R11A
C2
R11
R13
R2
74
7
73
70A
70A
70A
96
70C
R5B
R5A
C2
33A
54
95
5
2
53
19
B'WD
F'WD
R1OA
JACK
R13B
4
79
)
1
2
2
60
R6A
R6B
C1
82A
CCW C2
62
R11B
120
50
51
-
33
NEUTRAL DETECT
20
-
CKT
ROD IN HOLE/TRAM INTERLOCK
CKT
HOLDBACK VALVE
CW
R13A
NEUTRAL DETECT
OF 1200 PSI
R2A
70A
KNOB
MOUNT IN CONSOLE
B
ROD SUPPORT INTERLOCK
B
SV
PULLDOWN
59
58
B
D
ROTATION
R/S RET
U.T.DEC
PA
79B
82
121
20
X
RETRACTED(ON)
34
X
81
ROD SUPPORT
R14
A
9
90
X0
106
0X
OX
X0
98
DRILL
78
5
89
ROD INDEXING
A
RETRACT
A
79A
ROD SUPPORT
A
6
61
CAROUSEL
NO
CONTROL
CONTROL
NC
+
+
B
+
82
82
N
A
N
X
R
A
-
+
R
NC
NC
NO
NO
0-500
RES2
CONTROL
PROPEL
9
9
DRILL
FORCE
130
FEED
LS4
160
3
8
8
(SHT. 1)
80
78B
7
7
82 RES3
RES4
19
LS5
LS6
200
200
NEUTRAL
DETECT
82
82
82
82
82
82
82
NOTES:
(FRICTION HOLD,
(FRICTION HOLD,
CENTER LOCK)
BUTTON IN HANDLE
POSITION(OUT)
CENTER LOCK)
BUTTON IN HANDLE
DRILL MODE
NEUTRAL
PULL DOWN
DETECT
DRILL MODE
SPEED REDUCER
SPEED REDUCER
ROTATION
4. IF JACK/PROPEL INTERLOCK OPTION IS N0T USED, CONNECT
WIRE 70A TO RELAYS R5 AND R6. AND OMIT WIRE 70B.
/ , 70A R5 R6, 70B
5. LIMIT SWITCH ON CAM SHAFT OF OEM CONTROLLER, TO DETECT
80
80
PULLDOWN CONDITION.
20 A
CB#3
6
6
: , ,
7. FOR PROPEL INTERLOCK, IF NO ROD SUPPORT DO NOT INSTALL
RELAY 11. USE R13B CONTACTS FOR TRAM INTERLOCK.
, II. R13B
8. SWITCHES FROM DRILL CONTROLLERS. TO PROPEL CONTROLLERS.
10. STROBE LIGHT "ON" DURING TRAMMING ONLY. WARNING THE FOLLOWING NOTE DOES NOT APPLY TO THIS PART
SECRET INFORMATION, IS THE PROPERTY OF EPIROC
DRILLING SOLUTIONS, AND IS GIVEN TO THE
FABRICATION
DIM (mm) TOL (mm)
MACHINING
TOL (mm)
STRAIGHTNESS DATE
CHECKED BY
09.09.23
NH
EPIROC G
RECEIVER IN CONFIDENCE. THE RECEIVER BY DIM (mm) FLATNESS
EXPORT OF THIS DRAWING TO COUNTRIES STRUCTURAL WELDING MUST BE DONE BY WELDERS AND RECEPTION AND RETENTION OF THE DRAWING UNDER 1PL 2PL O 5 1O 15 2O 25 mm DATE 09.09.23 DRILLING SOLUTIONS LOCATION: NANJING, CHINA
ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES 600
1.5 ROUNDNESS
OUTSIDE OF CHINA IS SUBJECT TO CHINESE UP TO 400 0.4 0.13 (CIRCULARITY) ENG. APPVL. NH
PROCEDURES QUALIFIED IN ACCORDANCE WITH THE DS
19. C1 MEANS MAIN PUMP COIL CLOSE TO DE ON CS SIDE.
THAT, EXCEPT AS AUTHORIZED IN WRITING BY
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
C1 THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION
MFG. APPVL.
DATE DM75
GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
20. C1 MEANS MAIN PUMP COIL CLOSE TO DE ON NCS SIDE.
(SQUARENESS)
COPYRIGHT 2021 AND RADII TO BE 0.75
EPIROC PERMITTED FOR THIS ASSEMBLY UNLESS APPROVED BY
CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED
UNLESS OTHERWISE SPECIFIED, REMOVE PARALLELISM
FINISHED WEIGHT SIZE A1 REF.NO 2657663031
DWG
NO. 2310030526 P
C1 DRILLING SOLUTIONS EPIROC DRILLING SOLUTIONS
TO RETAIN THE DRAWING, OR UPON DEMAND,
ALL BURRS AND SHARP CORNERS AND
2310030526 SH 4 OF 19
RETURN THE DRAWING, ALL COPIES THEREOF, AND POSITION
COMM.
ALL RIGHTS RESERVED ALL MATERIAL COPIED THEREFROM. COUNTERSINK TAPPED HOLES TO BODY SIZE. CONCENTRICITY
SCALE 1.000 NO.
9
1 2 3 4 5 6 7 8 9 10
(BOTTOM COIL)
(BOTTOM COIL)
(OPTION)
(OPTION)
(BOTTOM COIL)
(OPTION)
(TOP COIL)
(BOTTOM COIL)
(TOP COIL)
(TOP COIL)
DUST COLLECTOR SIDE
RETRACT INDICATOR
END JACK CONTROL
PROPEL INTERLOCK
CAB SIDE JACK
TEST LAMP
TEST LAMP
TEST LAMP
JACK CONTROL
JACK CONTROL
/
NON DRILL
D.C. SIDE
CAB SIDE
RETRACT
RETRACT
RETRACT
EXTEND
EXTEND
EXTEND
LOWER
RAISE
/
HOIST
5
5
2658503165, SECT. 4
2658503165, SECT. 5
2658503165, SECT. 1
2658503165, SECT. 6
DPV
DPV
DPV
LOCKING
LOCKING
LOCKING
DPV
LOCKING
SPRING
RETURN
HANDLE
CENTER
CENTER
SPRING
RETURN
HANDLE
SPRING
RETURN
HANDLE
CENTER
SPRING
RETURN
HANDLE
R10
C1
C1
C1
C1
C2
C2
C2
C2
D8
28C
28C
28C
G
G
G
186
FAN BLOWER
(OPTION)
D10
D8
D9
LS13
171
170
66
C
R14
65
67
185
5
5
DCS(OPTION) CS(OPTION)
LADDER
LS13
244
C
27
184
181
183
182
LADDER
LS12
4-JACK OPTION
85
87
83
-
-
NO
NC
LS2
LS1A
183
LS3
CKT
CKT
CKT
CKT
X0
0X
OX
B
X0
B
FAST
JACK
DCS
LS3
181A
65A
182
181
84
88
86
LS7
11
X
X
LS2 182
LS1
SLOW
D
A
A
JACK
A
CS
D.C. SIDE
NON DRILL
END JACK
CONTROL
70B
CONTROL
CONTROL
CONTROL
LS1 181
HOIST
80
+
+
+
JACK
SIDE
JACK
CAB
JACK
REAR
82
82
82
82
80
80
80
80
80
80
80
80
80
E
6
6
CKT ELECTRONIC CONTROLLER. F
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
10
1 2 3 4 5 6 7 8 9 10
LUBRICATOR CONTROL
ELECTRIC THREAD
A
WATER INJECTION
(OPTION)
BLOWER MOTOR
PROPELLING
LOWER (RETRACT)
RAISE (EXTEND)
DUST CURTAIN
(BOTTOM COIL)
(OPTION)
(TOP COIL)
LOWERING
CONTROL
(LOWER)
(RAISE)
RAISING
TOWER
5
5
2658503165, SECT. 8
LOCKING
2658503165, SECT. 3
RETURN
HANDLE
CENTER
SPRING
DPV
C1
2658503165, SECT. 7
-
R22
C1
R
C2
KNOB
LOCKING
RETURN
2658503165, SECT. 2
CENTER
SPRING
HANDLE
B
M
202C
202D
C2
SET INTERVAL FOR 60 SECONDS
X
202E
DPV
2310072817
134
R21
WATER INJ.
C1
SV
A
C2
B1
16
18
R22
CONTROL
108
-
231
CKT
INTERVAL
+
TIMER
C
-
232
CKT
233
B
133
60
91
B
15
A1
109
X
92
202B
T3
231A
PS10 NO
X
CB#11(LOCATED IN DC BOX)
234
DUST CURTAIN
OPEN AT 900PSI
A
PRESS SWITCH
R21
900PSI
T4
T1
CONTROL
A
+
LOWERING
RAISING
CONTROL
202A
+
TOWER
BLOWER(OXOO)
RESET
OFF(XOOO)
WTR INJ(OOXO)
BOTH(OOOX)
20A
82
80
82
82
82
82
80
80
E
6
6
2
2
F
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
11
1 2 3 4 5 6 7 8 9 10
THROTTLE CONTROLLER
(NO-BUMP) (OPTION)
ANGLE PINNING
LOCKOUT RELAY
LOCKOUT RELAY
TOWER PINNING
VERTICAL PIN
ANGLE PIN
(OPTION)
BREAKOUT
CAROUSEL
RETRACT
LOADING
UNLOCK
EXTEND
STOWED
WRENCH
UNLOCK
CHAIN
SWING
LOCK
FORK
LOCK
5
5
2310113583, SECT 9,HP
2310113583, SECT 2
2310113583, SECT 3
2310113583, SECT 7
2310113583, SECT 5
2310113583, SECT 1
D14
D15
R17
R18
R
DPV
DPV
DPV
DPV
LOCKING
LOCKING
LOCKING
LOCKING
C
SPRING
RETURN
HANDLE
CENTER
SPRING
RETURN
HANDLE
CENTER
SPRING
RETURN
HANDLE
CENTER
SPRING
RETURN
HANDLE
CENTER
C1
C1
C1
C2
DPV
DPV
C1
C2
C2
C2
C2
C1
C1
C2
129A
R14A
24A
26A
26
24
117
116
128
94A
11
101A
129
123
126
-
-
100
CKT
CKT
CKT
CKT
R17B
93
R18B
B
B
B
R18A
R17A
D
12
UNLOCK
UNLOCK
THROTTLE CONTROLLER
X
X
101
94
122
127
(CS) 23 (DCS)
(CS) 25 (DCS)
HIGH PRESSURE
LS11
A
A
A
LS9
OOX
XOO
OOX
XOO
BREAKOUT
OFF
OFF
TS1
CAROUSEL
TS2
CONTROL
WRENCH
CONTROL
CHAIN
+
SWING
FORK
LS10
LOCK
LOCK
A.P.SW
LS8
T.P.SW
82
82
82
82
82
82
80
80
F
NOTES:
11. LIMIT SWITCH USED TO PREVENT ROTARY HEAD FROM HITTING CAROUSEL.
12. DON'T NEED TO CONNECT THIS CONTACT IF ANGLE DRILLING IS NOT SELECTED.
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
12
1 2 3 4 5 6 7 8 9 10
COOLER,WALKWAY
MOTOR 1# (OPTION)
MOTOR 2# (OPTION)
3# (OPTION)
PUMP 2# (OPTION)
PUMP 1# (OPTION)
TEST LAMP
(BOTTOM
(OPTION)
COIL)
PARKING BRAKE
B
CAB LIGHT
FLOW INDICATOR
PUMP SOLENOID
TEST LAMP
COOLER
(OPTION)
(OPTION)
TORQUE LIMIT
BRAKE ON
ON CONSOLE
5 PULSE TIMER
(TOP COIL)
INJECTION
2
(OPTION)
COLLECTOR
3
WASHER
2
WASHER
1
(OPTION)
WIPER
WIPER
WIPER
MOTOR
OPTION
WATER
VALVE
DUST
5
28C
2658503165, SECT. 7
28C
(-)
C
D12
C1
PS
R
SV
G
(A)
WP
(A)
(B)
(B)
-
(A)
WP
(B)
(+)
KNOB
(P)
(P)
B
(P)
F
68B
T
T
T
T
B
3A
(OPTION)
FEMA
PA
D13
F
T
T
F
T
68A
F
A
112
HIGH
PARK
HIGH
PARK
68
PARK
HIGH
LOW
LOW
LOW
A
114
115
42
GND
41
2658503165, SECT. 7
DHD TIMER
29
+24V +12V +12V
131
165
IN
WATER INJECTION
OUT
-
-
IN
LOCATED AT TANK
FLOW SWITCH
DRILL LIGHTS
KNOB
KNOB
114B
TRAM LIGHTS
43
45
46
44
48
47
49
36
35
OOX
XOO
PORT T
B
LOCATED AT CONSOLE
FEMA
C2
PARKING BRAKE
PA
ON/OFF
X
X
LUBE ON
OFF
OFF
OFF
OFF
118
TORQUE LIMIT
134
WATER INJ.
A
A
DC/PULSE
CONTROL
CONTROL
+
+
133
40
164
114A
E
40
28
80
82
40
82
82
82
CB#7
CB#6
15A
20A
CB#2
5A
20A
80
80
6
6
F
6
6
2
2
2
2
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE
UNSPECIFIED TOLERANCES CHARACTERISTIC SYMBOL O 1in DRAWN BY NH
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
13
1 2 3 4 5 6 7 8 9 10
CAMERA SYSTEM(OPTION)
THREAD LUBRICATOR
TACHOMETER (OPT)
GRACO AUTOLUBE
SOLENOID VALVE
IN ROTARY HEAD
B
CONTROL (OPT)
ROTARY TABLE
STROBE LIGHT
STROBE LIGHT
ANTI-RUMBLE
CLUTCH SOL.
PRESSURIZER
)
(OPTION)
(OPTION)
ON TOWER
(OPTION)
HEATER/
(
BLOWER
ON CAB
COMP.
MOTOR
14
CAB
5
5
LOCATED AT COMPRESSOR
CS
SV
OPEN AT 325 PSI,
21A
C
M
DISCHARGE PORT
STROBE
STROBE
MONITOR
HIGH PRESS.
BARE
CLOSED AT 2500PSI
NEAR COMPRESSOR
N/CLOSE
SV
205
M
206
LOCATED IN CAB
2500PSI
-
LOW LEVEL
SWITCH
TACH
SIG
PRESSURE SWITCH
HORN
HORN
203
SV
10A
+
RE-OPEN AT 6 PSI.
(BLACK)
CLOSE AT 34 PSI,
LOCATED AT EVAPORATOR
(ORANGE)
(YELLOW)
HI
(BROWN)
(WHITE)
BLUE
194A(GRAY)
(BLUE)
BAT(+)
(RED)
LOW
BAT(-)
LOW PRESS.
MED
DISCHARGE PORT
235A
236A
HI
N/OPEN.
80A
235
236
194
209A
MED
SWITCH
VACUUM
209
21
10
9
6
8
4
1
3
5
LOW
202
OFF
243
GLC 2200
PURPLE
THERMOSTAT
ON-OFF
A/C
E
18
TO SH 10,E-9
1A
CB#4
20 A
70A
80
80
80
7
7
82
82
80
80
80
7 70A 80
7 70A
F
6
6
6
2
2
16.NC PRESSURE SWITCH WILL BE ACTIVATED WHEN
PRESSURE HIGHER THAN 2300PSI.
2300PSI WARNING
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE
SECRET INFORMATION, IS THE PROPERTY OF EPIROC
UNSPECIFIED TOLERANCES
FABRICATION MACHINING
CHARACTERISTIC
STRAIGHTNESS
SYMBOL O 1in DRAWN BY
DATE
NH
09.09.23 EPIROC
THE FOLLOWING NOTE DOES NOT APPLY TO THIS PART DRILLING SOLUTIONS, AND IS GIVEN TO THE
DIM (mm) TOL (mm) TOL (mm) CHECKED BY NH G
RECEIVER IN CONFIDENCE. THE RECEIVER BY DIM (mm) FLATNESS
EXPORT OF THIS DRAWING TO COUNTRIES STRUCTURAL WELDING MUST BE DONE BY WELDERS AND RECEPTION AND RETENTION OF THE DRAWING UNDER 1PL 2PL O 5 1O 15 2O 25 mm DATE 09.09.23 DRILLING SOLUTIONS LOCATION: NANJING, CHINA
ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES 600
1.5 ROUNDNESS
OUTSIDE OF CHINA IS SUBJECT TO CHINESE UP TO 400 0.4 0.13 (CIRCULARITY) ENG. APPVL. NH
PROCEDURES QUALIFIED IN ACCORDANCE WITH THE DS THAT, EXCEPT AS AUTHORIZED IN WRITING BY
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
14
1 2 3 4 5 6 7 8 9 10
ADDITIONAL HEATER
(OPTION)
EFFICIENCY
(OPTION)
(OPTION)
DRILL AIR
INDICATOR
DEI RELAY
INDICATOR
PRESSURE
DRILLING
(OPTION)
(OPTION)
STRATA-
SWITCH
LOGGER
PLUS
B
5
5
PULLDOWN PRESS. SENSOR
TORQUE PRESS. SENSOR
ADDITIONAL HEATER
0.25 HP
R12
EMB
15A
COMPUTER DOWNLOAD
STRATALOGGER 2
DIB
(OPTIONAL)
238
DRILLER'S CONSOLE
DEI
LOCATED ON
HAND HELD
MDL 2
TERMINAL
OXO
OOX
OFF LOW HIGH
-
KNOB
ENCODER
OX
LOCATED IN TOWER
FEMA
PA
ON
FROM SH 9,E-2
X
OFF
124
A
E
FAN SPEED
CONTROL
80
82
82
80
80
7
7
6
6
2
2
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
15
1 2 3 4 5 6 7 8 9 10
CENTER LOCKING)
CENTER LOCKING)
CENTER LOCKING)
CENTER LOCKING)
INDICATOR LIGHT
RECEIVER POWER
SOLENOID VALVE
PROPEL SELECT
PROPEL DRILL
PROPEL ALARM
NON-CAB SIDE
PROPEL MODE
PROPEL MODE
PROPEL MODE
MAIN PUMP
MAIN PUMP
MAIN PUMP
MAIN PUMP
D.C.SIDE
CAB SIDE
D.C.SIDE
CAB SIDE
CAB SIDE
RELAYS
5
5
C
5
RECEIVER
RECEIVER
D13
HARNESS
HARNESS
R5
D4
SV
G
R6
D5
RMI
R4
R3
70B
FROM
FROM
6
70B
EX1
EX1
70B
-
+
X
B
A
70B
53
74
6
5
R11A
56
75
73
54
70A
57
76
EX1/3 TO 71
70C
R3B
R4B
R3A
R4A
53A
INTERLOCK
79A
77
5
R1OA
52
5
JACK
51
95
1 96
50
R5A
R6A
R5B
C1
R6B
C2
C1
C2
1
2
2
1
2
1
2
70A
59
58
60
79
-2
20
RECEIVER
82
XO
OX
OX
XO
CONTROLLER WIRING
DRILL
CONTROLLER WIRING
REFER SHEET 2, C
11
REFER SHEET 2
+1
FOR ROTATION
FOR PULLDOWN
PROPEL
(SHT. 1)
80
19
82
7
F
7
7
NOTES:
EX1 1 11
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
16
1 2 3 4 5 6 7 8 9 10
(OPTION)
FOR USE OF LIMIT-SWITCH
SEE CIRCUIT ON SHT 3 OF 11.
SH-3
CAROUSEL STOWED
FOR USE OF LIMIT-SWITCH
TRAM INTERLOCK
ROTARY HEAD UP
PULLDOWN FORCE
SEE CIRCUIT ON SHT 4 OF 11.
FEMA ACTUATOR
FOR USE OF LIMIT-SWITCH
11
SEE CIRCUIT ON SHT 3 OF 11.
DRILL FEED
(NO-BUMP)
& UP STOP
B
(NO BUMP)
PULLDOWN
CAROUSEL
(OPTION)
SENSOR
FORCE
LIMIT
5
5
5
B
G
PA
A
C
R11
R13
R2
98
MOUNT IN CONSOLE
-
R14
SEE CIRCUIT ON SHT 2 &3 OF 12
KNOB
82A
62
R15
R15
R15
B
FOR USE OF LIMIT-SWITCH
106
78
DECEL LIMIT SWITCH
X
D
308
27
UPPER TOWER
ROD SUPPORT
0-500
RES2
RETRACTED
T2
+
CONTROL
T3
T1
78A
T2
FORCE
DRILL
PS4
FEED
T3
T1
T2
T2
PS7
RES (50
T3
T3
T1
T1
E
PS6
PS5
82
82
82
82
82
82
82
82
80
80
80
80
80
F
CB#3
20 A
6
6
6
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE
UNSPECIFIED TOLERANCES CHARACTERISTIC SYMBOL O 1in DRAWN BY NH
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
17
1 2 3 4 5 6 7 8 9 10
SEAT HEATER
LED
5
5
5
B
BLACK
BLACK
2300000169
C
RED
TO REMOTE RECEIVER
EX1 WIRE 4(OPTION)
PRESSURE CONTROL
HEATER
C
QUICKEVAC
244
WHITE
PUMP
P
RED
ELECTRAK HD
THOMSON
FROM SH1,C-6
241E
241D
241C
RACOR FILTER
HEATER RELAY
X0
0X
OX
X0
RED
BLACK
BROWN
BLUE
R1
R1
R1
239C
D
SLOW
CAN+
CAN-
2
SPDT 2
243
241A
241B
RADIO REMOTE
239A
239B
RMI B
1
SPDT 1
FROM SH-2,E-5
E
239
241
5A
5A
30A
10A
70A
80
80
6
6
2
2
70A
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
18
1 2 3 4 5 6 7 8 9 10
RESISTOR
03-13046
COOL EVAPORATOR - COMBO UNIT
20 B
1 2 3 4
BLUE RELAY(R2)
NO
03-01704
ORANGE
NC BLOWER
C1 C2 MOTOR
BLACK
02-03523
C
ORANGE
BLACK C
ORANGE
C
ORANGE
RED
D
RED TO POWER SOURCE WHEN IGNITION IS ON
YELLOW
#6 START COOLING
LIQUID
CIRCUIT
FREON
#18
24VDC
(FROM CB4, SHT-6 OF 11 GRID 3-E)
F
NOTE:
17. BLOWER MOTOR RUNS AT MINIMUM SPEED WITH FAN .
SWITCH IN OFF POSITION. THIS IS TO CREATE POSITIVE
PREESURE INSIDE THE CAB. THROUGH RELAY (R1)
R1 EVAPORATOR
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
19
1 2 3 4 5 6 7 8 9 10
EARS(OPTION)
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
20
1 2 3 4 5 6 7 8 9 10
EARS(OPTION)
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
21
1 2 3 4 5 6 7 8 9 10
EARS(OPTION)
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
22
1 2 3 4 5 6 7 8 9 10
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
23
1 2 3 4 5 6 7 8 9 10
WHITE 14 26A VERTICAL P/N " NOT LOCKED" INDICATOR WHITE 14 152 HEAT DEV ON SW TO THERMOSTAT (HEAT DEV) C
WHITE 14 164 CAB LIGHT WHITE 14 153 HEAT DEV ON SW-FM HEAT/COOL SW
WHITE 10 28A TRAM LIGHTS SWITCH WHITE 14 154 INSULATION (GROUND FLT) ALARM
WHITE 10,14 29 LIGHTS: TRAM, WALKWAY, REC
WHITE 14 155 CONTACTOR, THERMAL O/L RELAY
WHITE 14 33,33A ROD SUPPORT EXTEND (OPTION)
WHITE 14 34 ROD SUPPORT RETRACT (OPTION) WHITE 14 156 AC HEATER (HEAT DEV) CONTACTOR
WHITE 14 37,38 THROTTLE SETTING CAT ENGINES WHITE 14 160 LOW RANGE SELECT FOR FEED
WHITE 14 40 WIPER OPTION WHITE 10 164 FROM CB TO DRILL LIGHT SWITCH
WHITE 14 41 WASHER MOTOR #1 (OPTION) WHITE 10 165 DRILL LIGHTS: TOWER TOP, POWER PACK, TOWER BOTTOM
WHITE 14 42 WASHER MOTOR #2 (OPTION)
WHITE 14 170,171 HOIST
WHITE 14 43 WIPER MOTOR #1 PARK
WHITE 14 44,45 WIPER MOTOR #1, LOW - OFF - HIGH (OPTION) WHITE 14 181,182,183,184,185,186 JACK/SPRING LADDER/FAN BLOWER RETRACT, PROPEL INTERLOCK (OPTION)
WHITE 14 46 WIPER MOTOR #2 PARK WHITE 14 190,191 PRESSURE SWITCH, CENTROMATIC LUBE (OPTION) D
WHITE 14 47,48 WIPER MOTOR #2, LOW - OFF - HIGH (OPTION) WHITE 14 192,193 LOW LEVEL SWITCH, CENTROMATIC LUBE (OPTION)
WHITE 14 49 WIPER MOTOR #3 PARK WHITE 14 194,195 PUMP SOLENOID, CENTROMATIC LUBE OPTION)
WHITE 14 35,36 WIPER MOTOR #3, LOW - OFF - HIGH (OPTION)
WHITE 14 198,199,200 ESPAR HEATER TIMER
WHITE 14 50,51 D. C. SIDE, MAIN PUMP, PROPORTIONAL ACTUATOR
WHITE 14 53,54 PROPEL MODE, D. C. SIDE, MAIN PUMP WHITE 14 201A DEI POWER SOURCE
WHITE 14 58,59 ROTATION, DRILL MODE, D. C. SIDE, MAIN PUMP WHITE 14 202 THREAD LUBE (OPTION)
WHITE 14 60 DRILL MODE, CAB SIDE, MAIN PUMP WHITE 14 203 VACUUM SWITCH (OPTION)
WHITE 14 61 PULL DOWN, DRILL MODE, ROD CHANGER BYPASS DIODE WHITE 12 204 RACOR FUEL HEATERS (OPTION)
WHITE 14 62 UPPER TOWER, DECEL LIMIT SWITCH AND TRAM INTERLOCK
CABLE 18/2 BLACK, CLEAR 205,206 ROTATION TACHOMETER (OPTION)
WHITE 14 63 PULLDOWN, DRILL MODE, POTENTIOMETER
WHITE 14 65 NON-DRILL END JACK RETRACT INDICATOR CABLE 18/2 BLACK, CLEAR 205,206 ROTATION TACHOMETER (OPTION)
WHITE 14 66 CAB SIDE JACK RETRACT INDICATOR WHITE 14 208,208A HATCH DOOR
WHITE 14 67 D.C, SIDE JACK RETRACT INDICATOR WHITE 14 209 CAB WARNING HORN (OPTION)
E
WHITE 14 68,69 PARKING BRAKE (OPTION) WHITE 14 209A COOLER WARNING HORN (OPTION)
WHITE 14 70,70A,70B,70C PROPEL MODE, JACK RETRACT, TRAM INTERLOCK (OPTION) 28B,28C,68A,68B,68C,23A,
WHITE 14 73,74 PROPEL MODE, CAB SIDE, MAIN PUMP WHITE 14
67A, 65A, 66A
TEST LAMP
WHITE 14 78,98 PULLDOWN FORCE LIMIT,CAROUSEL UNSTOWED WHITE 14 52,53A,56,57,71,75,76 77,79A REMOTE PROPEL OPTION
WHITE 14 79 DRILL MODE, CAB SIDE, MAIN PUMP
WHITE 12,14 80 POWER DISTRIBUTION FOR OEM CONTROLLERS WHITE 14 232,233 TOWER DOWN DECEL.
WHITE 14 81 HOLDBACK SOLENOID VALVE ON TOWER
WHITE 12,14 82 POWER FOR DRILL MODE FUNCTIONS
WHITE 14 82A ROD SUPPORT RETRACT RELAY (OPTION)
WHITE 14 83,84 CAB SIDE JACK CONTROL 7-SPOOL FUNCTIONS(2657750572) SPOOL FUNCTIONS(2310016202)
WHITE 14 85,86 NON-DRILL END JACK CONTROL
HOIST
WHITE 14 87,88 D.C. SIDE JACK CONTROL ROD CHANGER(CAROUSEL)
WHITE 14 89 NEUTRAL DETECT, ROTATION CONTROLLER TOWER RAISING
AUTO BREAKOUT
WHITE 14 90 NEUTRAL DETECT, PULL DOWN CONTROLLER F
DUST CURTAIN
WHITE 14 91,92 TOWER RAISING & LOWERING CHAIN WRENCH
WHITE 14 93,94,94A,94B TOWER PINNING JACK,FRONT,CAB SIDE
ROD SUPPORT
WHITE 14 95,96 CAB SIDE, MAIN PUMP, PROPORTIONAL ACTUATOR
JACK REAR
WHITE 14 98 PULLDOWN FORCE LIMIT (NO BUMP) TOWER PINNING
WHITE 14 100,101,101A ANGLE LEG PINNING JACK,FRONT,DCS
ANGLE PINNING
WHITE 14 106 PULL DOWN FORCE LIMIT
DUST COLLECTOR/WATER INJECTION
ROD INDEXING
SCHEMATICS,DC
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 09.09.23 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL.
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE DM75
COPYRIGHT 2021 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
24
25
1 2 3 4 5 6 7 8 9 10
TERMINATION RESISTOR
CHANGED TO EPIROC FORMAT
ADDRESS PLUG 0
9106182834
477/478 TO CABLES 481/482
SHT2:A1
J1939 CONNECTION ADDED CS RELAY PICTORAL
9106220700
IN CAB CONSOLE USS20
002 SHT3 ADDED DM75SP WIRING 20.08.14 EW JZ
WHITE,CAN-HI TO WIRE 37 302 01191
BLUE,CAN-LO TO WIRE 38
SHIELD,TO J1939 SHEILD
ADDRESS PLUG 0
9106220700
481
482
307
RCS BOX
D510 POWER
INPUT/OUTPUT 327
451
USB MODULE
(LOCATED IN RCS BOX) 3RD PARTY 328
ETHERNET
INTERFACE
454 453 452
456
ETHERNET
STANDARD 5 PIN M12 I/O WIRE CONFIGURATION C
POWER
3 1 +24V DC INPUT
458
STANDARD 4 PIN M12 POWER CONFIGURATION 1 2 0.5-4.5V SIGNAL
DIAGNOSTIC/ OPTIONAL WIFI CORRECTIONS
2
FEMALE END VIEW 3 NEGATIVE (-)
M12 ON SENSOR D
5 4 4 OPEN
PIN WIRE COLOR
1
1 BLACK +24V DC
3
RCS LITE ELECTRICAL BOX POWER AND GROUNDS 2
MALE END VIEW
2 BLUE +24V DC WATER TANK LEVEL SENSOR
3 GREEN/YELLOW NEGATIVE (-)
5 4
10A RCS I/O MODULE
TOP BOTTOM 3 4 BROWN NEGATIVE (-)
LOCATED IN MAIN ELEC. BOX 2R D510 C RED
I/O MODULE (PINS 1,2,5) 2 SIGNAL
10AWG CB1 B BLACK
1 3 NEGATIVE (-)
CCI (PINS 1,2) 2 A WHITE
RP 10A 1 +24 VDC
CONNECT TO GE MULTILIN 7 3R RED LION CONVERTER (TERMINAL 10)
0 1
MOTOR CONTROLLER CB2 7/8 I/O POWER CABLE
5 4R 18AWG POWER OVER ETHERNET
(TERMINALS NUMBERS 3 7 25A FEMALE END VIEW
SAME AS WIRE NUMBERS) 1R 5A
1 1 2 3
14AWG 4 8 14AWG RCS 4R GPS PIN WIRE COLOR PROXIMITY SWITCHES
PLUG VIEW CB3
501 RS485 WIRELESS ACCESS POINT 4 SOURCE (PNP) PROXIMITY SWITCH
1R 2 6
1 (COMM)
2 (+24V)
3 (N/C)
SYMBOL LEGEND
BULKHEAD CONNECTOR
BILL OF MATERIALS
335
ITEM NUMBER
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
26
1 2 3 4 5 6 7 8 9 10
NON-CAB
CKT
SIDE
JACK
CONTROL 5
SPRING
RETURN
CENTER + A X B - 87R
FROM PWM CONV. J1
6 7 80 82 6 7 80 82 DRILL 5
LOCKING ALIR1 FEED KNOB
87R 87
C2 EXTEND (TOPCOIL)
ORIGINAL RIG WIRING
FORCE B
WIRING
ALIR2 DPV NON-DRILL END JACK CONTROL
80 86R 86
C1 RETRACT (BOTTOM COIL) 82 ADD CS RELAY TO
MAIN ELECTRICAL BOX
LS1 LS1A 86R
FROM PWM 7
80 65A 65 CONV. J1 106 98
G NON-DRILL END JACK DRILL FEED FORCE
RETRACT INDICATOR CS
80 181A 181 65R 28C
TO PWM CONV. J3 200 0-500 TO PWM
82 78A 78 LS4 98R CONV. J3
TEST LAMP OPTION 7 WHITE PULLDOWN FEMA ACTUATOR
RES2 CS
D9 BROWN
4 JACK OPTION
78 98 0 A CAROUSEL STOWED
183 0 1 PA
CAB SIDE R10 JACK RETRACT/ MOUNT IN CONSOLE BLUE LIMIT SWITCH
CKT PROPEL INTERLOCK OPTION FEMA
END
PULLDOWN FORCE
JACK FOR FIELD INSTALL, ADD 98
D7 LIMIT (NO BUMP) D
CONTROL NEW CABLE FROM MAIN BOX BLACK
BREAKOUT TO LS4 IN TOWER AND FOLLOW
CKT
FORK WIRE COLORS SHOWN.
CONTROL
SPRING
RETURN
CENTER + A X B - 83R
FROM PWM CONV. J1
LOCKING ALIR3
83R 83 SPRING
C2 EXTEND (TOP COIL)
RETURN
DPV CAB SIDE JACK CONTROL CENTER + A X B -
80 84R ALIR3 84 TO PWM
C1 RETRACT (BOTTOM COIL) LOCKING 126R
CONV. J2 126
C2 ENGAGE
LS2 84R CDX
FROM PWM TO RCS DPV BREAKOUT WRENCH
80 66 CONV. J1 82 127
G CABSIDE JACK C1 DISENGAGE
RETRACT INDICATOR 127R
181 66R TO PWM
182 TO PWM CONV. J2 28C
CONV. J2
TEST LAMP OPTION
6 7 80 82 5
D8
E
6 7 80 82 5
CS
0 1 5
98R
3 7
106
4 8
98
2 6
CS RELAY WIRING F
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
27
1 2 3 4 5 6 7 8 9 10
6 7 5
DRILL POSITION A
DRILL R7A R8A
FEED KNOB 8 6 17 8 6 19 OX 20 0 1
R9 START INTERLOCK
FORCE 5
RCS LITE
6 7 80 82
+ A X B - DRILL/PROPEL 11
82
WIRING ADD CS RELAY TO OX
Y STROBE LIGHT ON PLATFORM REAR OPTION
MAIN ELECTRICAL BOX
XO
CB3 G PROPEL MODE INDICATOR LIGHT OPTION
106 98 80 OX D5
20 A XO 70A 70A
CS PROPEL ALARM
80 70R TO PWM 9
R10A R15A
CONV. J3 8 6 70C 2 4 70B 0 1
R5 JACK INTERLOCK
DRILL FEED FORCE
50 0-500 JACK PROPEL
82 78A 78 98 0 A PULLDOWN FEMA ACTUATOR 0 1
PA 82 INTERLOCK INTERLOCK R6 PROPEL SELECT RELAYS
PULLDOWN FORCE B
R12B FEMA D4
RES2 LIMIT (NO BUMP)
NEUTRAL DETECT
82 82
SV PROPEL DRILL SOLENOID VALVE
R23A DETECT
TO PWM
98R CONV. J3
7 106A WHITE
CS
R12A R14A 0-500 COM NO NC
Multifunction Control 5 6 7
R11A R5 R5
+ +
8 6 61C 8 7 60 7 8 8 6 73
80 80C
R23 R23B R19A R2A R4A
61 61A 61B 8 6 73
R13A R14B A 95 95R A
CFX TO PWM C
R23-1 TO PWM. CONV J1 1
X 0-500 CONV. J1 X
R13B 100 PROPEL MODE, CAB SIDE, MAIN PUMP
R23-1A R19B
NO 79A 79B 79C 8 7 2 5 74 SPRING RETURN TO NEUTRAL
80 BROWN WHITE 321 CAROUSEL SWING B CW 5SH B
R12 CENTER LOCKING
PROXIMITY SWITCH 79R TO PWM R3-1A DN/FWD
- CONV. J1 5
-
R13 CAB
5 GROUND
PS6 R 5SH
2 301 BRAKE RELEASE
SV
BUTTON 81 PIR
ON HANDLE D SV 5R
BROWN NO WHITE 322
1
96
80 CAROUSEL INDEX HOLDBACK VALVE CCW
R14
PROXIMITY SWITCH N UP/BKWD
R5 R5
79 3 4 4 2 74 OR 79B
9 8 7 D
PS6A
82
PULLDOWN CONTROLLER INTERLOCK
90 0 1
R7
FEED UP & DOWN CONTROLLER/ DRILL MODE
FRICTION HOLD, CENTER LOCK
70B 70B
DETECT
82
NEUTRAL COM
5
NO
6
NC
7
DETECT Multifunction Control 58 54
+
8 6
+
7 8
R6 R6
ROTATION / 50R PROPEL MODE
DRILL MODE TO PWM 54
A CONV. J2 A D.C.SIDE E
FRICTION
HOLD 50 MAIN PUMP
1
CRX TO PWM X
CENTER LOCK X
CONV. J2 (SPRING RETURN TO NEUTRAL,
2 5 CAB 53 CENTER LOCKING)
B CW 5SH GROUND
B
F'WD
- 5
- 301
5
R 5SH
2
D 51 PIR
1
TO PWM 5R
CCW 51R
CONV. J2
N B'WD
59 53 OR 53A
3 4 4 2
9 8 7 R6 R6 5
F
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
28
6 7 80 82 5
1 2 3 4 5 6 7 8 9 10
6 7 5
DRILL POSITION
R7A R8A
8 6 17 8 6 19 OX 20 0 1
R9 START INTERLOCK
DRILL/PROPEL 11
Y STROBE LIGHT ON PLATFORM REAR OPTION
OX
XO
CB3 G PROPEL MODE INDICATOR LIGHT OPTION
80 OX D5
20 A XO 70A 70A
PROPEL ALARM
80 70R TO PWM 9
R10A R11A
CONV. J3 8 6 70C 2 4 70B 0 1
R5 JACK INTERLOCK B
JACK PROPEL
0 1
82 INTERLOCK INTERLOCK R6 PROPEL SELECT RELAYS
D4
NEUTRAL DETECT
70B 70B
MP) Y STROBE LIGHT ON CAB OPTION
82
SV PROPEL DRILL SOLENOID VALVE
Multifunction Control
R13A R5 R5
+ +
8 6 60 7 8 8 6 73
U.T.DECEL
R2A
61 ROD SUP. 73
A
8 6
95 TO PWM A
RETRACT 95R
CONV. J1
CFX
TO PWM. CONV J1 1 C
X 0-500 X
100 PROPEL MODE, CAB SIDE, MAIN PUMP
R14 R11B
79A 79B 8 7 2 5 74 SPRING RETURN TO NEUTRAL
B CW 5SH B
CENTER LOCKING
79R TO PWM DN/FWD
-
PROPEL INTERLOCK RELAY
CONV. J1
CAB
5
- LOCATED IN CAB CONSOLE
5 GROUND PIR
R 5SH
2 PK4 FROM SHT4,C4 0 1 PK3 FROM SHT4,C4
BUTTON 81 PIR
ON HANDLE D SV 5R 5R FROM ZONE C5 3 7
1
96 5R FROM ZONE A5
HOLDBACK VALVE CCW
N UP/BKWD 5 FROM ZONE C5 4 8
R5 R5 2 6
79 3 4 4 2 74 OR 79B
9 8 7
D
82
PULLDOWN CONTROLLER INTERLOCK
90 0 1
R7
FEED UP & DOWN CONTROLLER/ DRILL MODE
FRICTION HOLD, CENTER LOCK
70B 70B
82
NEUTRAL
DETECT Multifunction Control 58 54
+
8 6
+
7 8
R6 R6
ROTATION / 50R
DRILL MODE TO PWM 54
A CONV. J2 A
FRICTION
50 E
HOLD 1
CRX TO PWM X
CENTER LOCK X
CONV. J2
2 5 CAB 53
B CW 5SH GROUND
B
PROPEL MODE
F'WD
- -
5 D.C.SIDE
MAIN PUMP
5 (SPRING RETURN TO NEUTRAL,
R 5SH
2
CENTER LOCKING)
D 51 PIR
1
TO PWM 5R
CCW 51R
CONV. J2
N B'WD
59 53 OR 53A
3 4 4 2
9 8 7 R6 R6 5
F
82 89
6 7 80 82
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
29
1 2 3 4 5 6 7 8 9 10
RED LION
RED LION SETTINGS: FREQUENCY
1437 HERTZ CONVERTOR
4-20mA
S1,S2,S3=OFF
MIN/MAX RESPONSE TIME = 200msec 1 2 3 RCS LITE PWM CONVERTER CIRCUIT BOARD
INSTALLED IN RCS LITE ELECTRICAL BOX
206 J4
MAGNETIC PICKUP 4 5 6 A B
205 TB-1 172299-1108
(LOCATED IN ROTARY HEAD)
IN S C 1 5
SHIELD WIRE-NOT T WATER TANK BROWN 2 6
D510 X2 PIN 1
LEVEL SENDER WHITE D510 X2 PIN 2
A
TERMINATED AT T 3 7 B
3 PIN DEUTSCH BLUE D510 X2 PIN 3
SENSOR OUT U 8
S VIEW OF PLUG END D510 X2 PIN 4
4 401
A = POWER PWM TO DIGITAL D510 X6 PIN 4
7 8 9 2
B = SIGNAL CONVERTER
D510 X6 PIN 2
1
C = GROUND D510 X6 PIN 1
PWM TO DIGITAL 3
D510 X6 PIN 3
10 11 12 CONVERTER
POWER/GROUND
J1 TP10 TP11
172299-1114 TP1 TP2 TP3
+5V +24V GND
RHS 1
3R 2
{
95R
FROM SHT 3, C6-C7 3
FROM 5 CFX
4 J5
SHT 1 79R
5 172299-1116
5 83R 6 1
D510 X7 PIN 4
84R 7 2
D510 X7 PIN 3
8 3
D510 X7 PIN 2
ALIR3 85R 9 4
D510 X8 PIN 4
0 1 TS5 86R 10 5 C
D510 X8 PIN 3
11 6
D510 X8 PIN 2
3 7 87R 12 7
D510 X9 PIN 4
88R 13 8
84R D510 X9 PIN 3
{
(TO CONTROLLER B TERMINAL) 83R 14 9 402
4 8 D510 X9 PIN 2
83 10
2 6 D510 X10 PIN 4
TO SHT 2, B6 11
84 D510 X10 PIN 3
12
D510 X10 PIN 2
13
(TO CONTROLLER A TERMINAL) 84R D510 X11 PIN 4
14
D510 X11 PIN 2
J2 15
TP4 TP5 TP6 D510 X12 PIN 4
172299-1112 16 D510 X12 PIN 2
7
PK4
8
ALIR2 (FROM A5) PK3
JK2 9
1
{
0 1 TS5 50R FOR DRILL WITH 2 NDE
FROM SHT 3, A6 2 PWM TO DIGITAL
JACKS, MOVE J8 JUMPER
51R
3 7 3 CONVERTER
TO POSITION 1-2.
CRX
4
{
D
86R 126R 1 2 3
{
(TO CONTROLLER B TERMINAL) 85R FROM SHT 2, B3 127R 5 PWM TO DIGITAL
4 8 J8
85 6 CONVERTER J6
2 6 CDX 172299-1114
TO SHT 2, C6 10
86
11 13
MAINFRAME INCLINOMETER (TO CONTROLLER A TERMINAL) 86R
(FROM SHT2, B6) 66R
(FROM SHT2, D6) 67R 12 14
7
D510
D510
X14
X14
PIN
PIN
4
2
{
(TO CONTROLLER B TERMINAL) 87R (FROM SHT3, D7) 70R
5 4 8 AE2 6 11
4 6 87 7 12
1 4 TO SHT 2, D6 2 6 AE1
{
88 8
MP4
7 TO MAINFRAME 9
3 AUTOLEVEL MP1
(TO CONTROLLER A TERMINAL) 88R INCLINOMETER 10
ENABLE SWITCH MP3
2 1 ZONE B8 11 J7 E
(LOCATED IN MR4
12 172299-1108
8 2 3 CAB CONSOLE)
13 8
CAB POWER D510 X20 PIN 4
8 PIN M12 4 PIN DEUTSCH 14 5
WIRE 7 D510 X20 PIN 1
FEMALE END VIEW OF PLUG END 7
D510 X20 PIN 3
BYPASS SWITCH 4
D510 X21 PIN 4
(LOCATED ON CAB CONSOLE) 3 404
MP4 D510 X21 PIN 3
306 TB-2 6
LOCATED MP1 CAB POWER WIRE 7 TILT SWITCH FORWARD D510 X20 PIN 2
TS4 1 2
IN CAB MP3 24V OUTPUT WHEN ROTATION WHITE D510 X21 PIN 2
5 2 1
MR4 PITCH & ROLL < 6 PRESSURE BROWN D510 X21 PIN 1
3
SENSOR BLUE
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
30
1 2 3 4 5 6 7 8 9 10
5
323
D510
ALIR3 J1 B
83 83R
X7a JACK EXTEND, CABSIDE, DRILL END
X7 X13
ALIR3 J1 J5
X7b JACK RETRACT, CABSIDE, DRILL END
84 84R PWM ADDRESS
ADDRESS PLUG
OUTPUT 9106220700
33Hz
TOWER
321 DISCONNECT X3 X21 J3
X3a TOWER INCLINOMETER (PITCH) 320 J7 MAINFRAME INCLINOMETER - ROLL X21a
311 ANALOG ANALOG
1
X4 X22
X4a NOT USED 325 350 NOT USED X22a
312 ANALOG ANALOG 318 D
X4b PULLDOWN PRESSURE SENSOR (CS PUMP A) INPUT INPUT BIT AIR PRESSURE SENSOR X22b
PK4
X10a PROPEL INTERLOCK PIR
X10 X16
J2 J5 355 JACK ON GROUND - DRILL END CABSIDE X16a
JK2 DIGITAL DIGITAL 314
2
X10b JACK INTERLOCK JIR
OUTPUT INPUT JACK ON GROUND - DRILL END NON-CABSIDE X16b
1
PK3
2
J2
A 50R 4 JACK ONLY
X11a CONTROLLER-ROTATION, FORWARD COMMAND
X11 X17
1
J2 J5 375 E
B 51R PWM TO DIGITAL DIGITAL DIGITAL 315 JACK ON GROUND - NON-DRILL END NON-CABSIDE X17a
X11b CONTROLLER-ROTATION, REVERSE COMMAND
CONVERTER INPUT INPUT JACK ON GROUND - NON-DRILL END CABSIDE X17b
J2
X CRX
J1
A 95R
X6a CONTROLLER-FEED, DOWN COMMAND
X6 X24 70R 70A
J1 J4 J6 J3 PROPEL MODE SELECTED X24a
B 79R PWM TO DIGITAL DIGITAL DIGITAL
X6b CONTROLLER-FEED, UP COMMAND
CONVERTER INPUT INPUT AE1 AE2
J1 AUTOLEVEL ENABLE SWITCH X24b
X CFX
J2
A 126R NOTE: TILT SWITCH POWER AND GROUND SUPPLIED BY CAB
X12a CONTROLLER-DECK FORK, EXTEND COMMAND
X12 X18 TS4 5 TS4
J2 J5 J6 J3 ALIR TILT SWITCH X18a
B 127R PWM TO DIGITAL DIGITAL DIGITAL
X12b CONTROLLER-DECK FORK, RETRACT COMMAND
CONVERTER INPUT INPUT 98R 98
J2 CAROUSEL STOWED X18b
X CDX
SCHEMATIC,RCS LITE
EXPORT ADMINISTRATION REGULATIONS. EPIROC DRILLING SOLUTIONS, IT WILL (1) NOT
2.5
400 - 2000 0.7 0.40 DATE 18.01.03 TITLE
STRUCTURAL WELDING PROCEDURE CHN/AWS-02 AND USE THE DRAWING OR ANY COPY THEREOF OR THE 600 TO 3000
ANGLES 0 30'
ANGULARITY
CONFIDENTIAL OR TRADE SECRET INFORMATION MFG. APPVL. HS
THE AWS STRUCTURAL WELDING CODE ANSI/AWS D1.1 THEREIN; (2) NOT COPY THE DRAWING; (3) NOT
3000 UP 3.0 UNSPECIFIED FILLETS PERPENDICULARITY FIRST ANGLE PROJECTION DATE 18.01.03 DM30/DM75
COPYRIGHT 2020 GMAW, SHORT CIRCUIT TRANSFER MODE, IS NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE
AND RADII TO BE 0.75 (SQUARENESS)
31
32
Hydraulic Diagram
LIST OF CONTENTS
Part no Description Remarks Page
2310110594 HYDRAULIC SCHEM 34 - 36
33
34
35
36
epiroc.com