Product datasheet
Specifications
                                     iC60N - miniature circuit breaker -
                                     1P - 10A - C curve
                                     A9F74110
 Main
 Device application          Distribution
 Range                       Acti9
                                                                                                     Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
 Product name                Acti9 iC60
 Product or component type   Miniature circuit-breaker
 Device short name           IC60N
 Poles description           1P
 Number of protected poles   1
 [In] rated current          10 A
 Network type                DC
                             AC
 Trip unit technology        Thermal-magnetic
 Curve code                  C
 Breaking capacity           6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
                             10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2
                             15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
                             10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
                             36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
                             20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
 Utilisation category        Category A conforming to EN 60947-2
                             Category A conforming to IEC 60947-2
 Suitability for isolation   Yes conforming to EN 60898-1
                             Yes conforming to EN 60947-2
                             Yes conforming to IEC 60898-1
                             Yes conforming to IEC 60947-2
 Standards                   IEC 60947-2
                             EN 60898-1
                             IEC 60898-1
                             EN 60947-2
 Complementary
 Network frequency           50/60 Hz
 Magnetic tripping limit     8 x In +/- 20 %
  12 Jul 2025                                                                                    1
[Ics] rated service breaking     27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
capacity                         7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
                                 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
                                 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
                                 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
                                 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
                                 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
                                 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
                                 10 kA 100 % conforming to EN 60947-2 - 72 V DC
                                 10 kA 100 % conforming to IEC 60947-2 - 72 V DC
                                 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
                                 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class                 3 conforming to EN 60898-1
                                 3 conforming to IEC 60898-1
[Ui] rated insulation voltage    500 V AC 50/60 Hz conforming to EN 60947-2
                                 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand   6 kV conforming to EN 60947-2
voltage                          6 kV conforming to IEC 60947-2
Contact position indicator       Yes
control type                     Toggle
Local signalling                 Trip indicator
Mounting mode                    Fixed
Mounting support                 DIN rail
Comb busbar and distribution     Top or bottom: YES
block compatibility
9 mm pitches                     2
Height                           85 mm
Width                            18 mm
Depth                            78.5 mm
Net weight                       0.215 kg
Colour                           White
Mechanical durability            20000 cycles
Electrical durability            10000 cycles
Connections - terminals          Single terminal (top or bottom) 1…25 mm² rigid
                                 Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length            14 mm for top or bottom connection
Tightening torque                2 N.m top or bottom
Earth-leakage protection         Without
Environment
IP degree of protection          IP20 conforming to IEC 60529
                                 IP20 conforming to EN 60529
Pollution degree                 3 conforming to EN 60947-2
                                 3 conforming to IEC 60947-2
Overvoltage category             IV
Tropicalisation                  2 conforming to IEC 60068-1
Relative humidity                95 % at 55 °C
Operating altitude               0...2000 m
Ambient air temperature for      -35…70 °C
operation
Ambient air temperature for      -40…85 °C
storage
   2                                                                                               12 Jul 2025
Packing Units
Unit Type of Package 1         PCE
Number of Units in Package 1   1
Package 1 Height               7.000 cm
Package 1 Width                1.800 cm
Package 1 Length               9.500 cm
Package 1 Weight               107.000 g
Unit Type of Package 2         BB1
Number of Units in Package 2   12
Package 2 Height               8.200 cm
Package 2 Width                9.900 cm
Package 2 Length               22.500 cm
Package 2 Weight               1.348 kg
Unit Type of Package 3         S03
Number of Units in Package 3   132
Package 3 Height               30.000 cm
Package 3 Width                30.000 cm
Package 3 Length               40.000 cm
Package 3 Weight               15.391 kg
Contractual warranty
Warranty                       12 months
12 Jul 2025                                3
        Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental Data explained
How we assess product sustainability
       Environmental footprint
       Carbon footprint (kg.eq.CO2 per CR, Total Life cycle)      13
       Environmental Disclosure                                   Product Environmental Profile
  Use Better
       Materials and Substances
       Packaging made with recycled cardboard                     No
       Packaging without single use plastic                       Yes
       EU RoHS Directive                                          Compliant
       SCIP Number                                                26ff71d1-98cf-4280-8725-455b9a6b2fb9
       REACh Regulation                                           REACh Declaration
  Use Again
       Repack and remanufacture
       Circularity Profile                                        No need of specific recycling operations
       Take-back                                                  No
                                                                        The product must be disposed on European Union
       WEEE                                                             markets following specific waste collection and never end
                                                                        up in rubbish bins
   4                                                                                                                        12 Jul 2025
Product datasheet                     A9F74110
Image of product / Alternate images
Alternative
12 Jul 2025                                      5
Product datasheet   A9F74110
 6                             12 Jul 2025