General Dealer For Mithi Shoko by Marshal Donnel
General Dealer For Mithi Shoko by Marshal Donnel
NOTES:
VERTICLE D.P.M floor tiles to Architect's 12mm top board or similar
SHOP approval RWDP approved ceiling on 38x38mm branderings @
400mm centres both ways.
foundation :
VERANDAH 40mm grano screed V. dpc
FF LEVEL I.b.r deck roofing sheets purlins all
to S.E detail, Pitch- 22,5
690x230 concrete strip footing to take 230mm brickwork,
Precast concrete copping plastered
concrete slab 900mm wide precast concrete paving
& painted as specified for the walls & painted as specified for the walls 575 x 230mm under 115mm internal partitions.
all round on 25mm sand blinding.
Depth to be determined by site conditions- min 700mm.
well compacted hardcore Stepped galvanized iron flushing Brickwork under DPC to have brickforce every 2 courses.
1491
1692
fill
Stepped galvanized iron flushing
slab :
100mm concrete floor slab in 1:3:6 mixture on minimum
600
D.P.M
Storeroom 150mm rammed fill after removal of all loose turf-ant-proof
230
R.C Beam
0.5mm Chroma deck sheets treatment underside fill and to 1500 beyond curtillage of roof
on steel canopy to ses's detail
Slab level to be minimum 200mm above natural ground level.
3200
690 Shop Retail
brickwork
2400
STEP DOWN DETAIL FOOTING DETAIL Above DPC, brickforce every four courses. Prestressed
lintols over door and window openings.
SCALE 1 : 25 scale 1:20
Detail A External brickwork woodfloat sand/cement render to take
two coats external PVA paint.Kitchen and bathroom areas
2400
to have white-glazed wall tile to door head + render and
1200
set + pva. All other rooms render and set to take two
2300
WINDOW AND DOOR SCHEDULE coats external quality pva.
2500 roof :
4400 A 10 year guarantee for ant
A 10 year guarantee for ant
poison to be provided &
0.5mm Chroma deck roofing sheets on steel
poison to be provided & 690
approved during construction approved during construction purlings & steel trusses,all to Structural Engineer's detail
1620
2300
600 600
115 walls rest on 500x230 reinforced conc (1:3:6) footings strip foundation Foundation walls to have brick force
380
WO2 1230 walls rest on 700x230 reinforced conc (1:3:6) footings strip foundation every 3rd course fixed to wall with g.i. hoops embeded 4 courses into brickwork.
G.I. flashing to all roof-wall junctions.
2100
40mm cement sand screed and floor on 100mm conc- floor Excavate 200min. topsoil and backfill
1030
slab reinforced with mesh wire ref- D.P.M on well compacted with approved gravel fill compacted
1120 in layers Roof pitch 4
200mm layers of hardcore after stripping off vegetable top soil.
900
Final layer of hardcore surface to be treated against termites by
specialist prior to laying D.P.M.
ceiling
1020
230 2400
drainlayer/plumber :
woodfloat plaster with 1 coat plus 3 Stepped galvanized iron flushing All water taps to be cobra or equal approved.
coats exterior quality P.V.A paint
colour to Owner's approval
0.5mm Chroma deck sheets
All toilet pans and cisterns to be white close-couple
complete with white plastic seats.
Aluminum door frames White porcelain toilet roll holder recessed into wall.
All WHBs white pedestal by 'Beta.'
600mm wide x760mm mirror above every WHB.
Shop Retail White porcelain soap holder to every shower recessed
Screed
Provide mechanical ventilation
into brickwork 100 litre roof-mounted water heater.
One stainless steel vegetable prep. sink to kitchen.
Conc- service counter with tiles
FLOORS
-finishes to rooms as indicated on floor plans.
woodfloat plaster with 1 coat plus 3 300x300mm non-slip ceramic floor tiles to toilets
coats exterior quality P.V.A paint and bathrooms and kitchen.
colour to Owner's approval
SOUTH ELEVATION Ground floor slab on damp proof membraine
9270
15000
Serving area scale 1:100 -all back fill to rceive anti-proof treatment and
Display shelves
ROOM VENTILATION
Display fridge Minimum of four airvents per room, exact positioning to be to builder's
discretion. Rooms without direct external ventilation to have either
115
0.5mm Chroma deck sheets perforated trap door or egg-crate ceiling or preferably mechanical
i.b.r sheets cladding
ventilation to be used.
115
3000
M Ndlovu HRDC/PG01
230
A21 Mzilikazi
woodfloat plaster with 1 coat plus 3 Bulawayo
woodfloat plaster with 1 coat plus 3 coats exterior quality P.V.A paint
coats exterior quality P.V.A paint colour to Owner's approval
0774987706
colour to Owner's approval [email protected]
230
6000
EAST ELEVATION NORTH ELEVATION PROJECT
scale 1:100