The document outlines construction details for a building project, including specifications for foundations, walls, roofing, and finishes. It includes various measurements, materials to be used, and guidelines for ensuring structural integrity and aesthetic quality. Additionally, it specifies requirements for plumbing, electrical installations, and ventilation systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views1 page

General Dealer For Mithi Shoko by Marshal Donnel

The document outlines construction details for a building project, including specifications for foundations, walls, roofing, and finishes. It includes various measurements, materials to be used, and guidelines for ensuring structural integrity and aesthetic quality. Additionally, it specifies requirements for plumbing, electrical installations, and ventilation systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

12600

NOTES:
VERTICLE D.P.M floor tiles to Architect's 12mm top board or similar
SHOP approval RWDP approved ceiling on 38x38mm branderings @
400mm centres both ways.
foundation :
VERANDAH 40mm grano screed V. dpc
FF LEVEL I.b.r deck roofing sheets purlins all
to S.E detail, Pitch- 22,5
690x230 concrete strip footing to take 230mm brickwork,
Precast concrete copping plastered
concrete slab 900mm wide precast concrete paving
& painted as specified for the walls & painted as specified for the walls 575 x 230mm under 115mm internal partitions.
all round on 25mm sand blinding.
Depth to be determined by site conditions- min 700mm.
well compacted hardcore Stepped galvanized iron flushing Brickwork under DPC to have brickforce every 2 courses.

1491

1692
fill
Stepped galvanized iron flushing
slab :
100mm concrete floor slab in 1:3:6 mixture on minimum

600
D.P.M
Storeroom 150mm rammed fill after removal of all loose turf-ant-proof

230
R.C Beam

0.5mm Chroma deck sheets treatment underside fill and to 1500 beyond curtillage of roof
on steel canopy to ses's detail
Slab level to be minimum 200mm above natural ground level.

3200
690 Shop Retail
brickwork

2400
STEP DOWN DETAIL FOOTING DETAIL Above DPC, brickforce every four courses. Prestressed
lintols over door and window openings.
SCALE 1 : 25 scale 1:20
Detail A External brickwork woodfloat sand/cement render to take
two coats external PVA paint.Kitchen and bathroom areas

2400
to have white-glazed wall tile to door head + render and

1200
set + pva. All other rooms render and set to take two

2300
WINDOW AND DOOR SCHEDULE coats external quality pva.

2500 roof :
4400 A 10 year guarantee for ant
A 10 year guarantee for ant
poison to be provided &
0.5mm Chroma deck roofing sheets on steel
poison to be provided & 690
approved during construction approved during construction purlings & steel trusses,all to Structural Engineer's detail
1620
2300

spacing of +/-750mm c/c over 50x76mm timber wall plate

600 600
115 walls rest on 500x230 reinforced conc (1:3:6) footings strip foundation Foundation walls to have brick force
380
WO2 1230 walls rest on 700x230 reinforced conc (1:3:6) footings strip foundation every 3rd course fixed to wall with g.i. hoops embeded 4 courses into brickwork.
G.I. flashing to all roof-wall junctions.

2100
40mm cement sand screed and floor on 100mm conc- floor Excavate 200min. topsoil and backfill

1030
slab reinforced with mesh wire ref- D.P.M on well compacted with approved gravel fill compacted
1120 in layers Roof pitch 4
200mm layers of hardcore after stripping off vegetable top soil.

900
Final layer of hardcore surface to be treated against termites by
specialist prior to laying D.P.M.
ceiling
1020

NC4F Foundation to firm load bearing ground depth to be determined


on site minimum 1200mm.
1300 1800 1300
R C BEAM SECTION NC2F WO1 DO1 WO1
12mm plasterboard ceiling nailed to 38x38mm
timber battens fixed to underside of the beams trusses
scale 1:20
CROSS SECTION X-X -tyro leon plaster finish with 150mm smooth margins.
-100mm wood crown moulding cornice.
X

6000 -3 coats external pva ceiling paint.


scale 1:100
230 5540 230 painter :
All surfaces to be free of dust and rust.
800 4400 800 All gutters and downpipes to have 1 coat etching primmer
one undercoat and two coats rubbed down between coats.
Doors, door frames, and window frames to have one
Precast concrete copping plastered
& painted as specified for the walls
undercoat and two coats oil rubbed down between coats.
Verendah
2400

230 2400

drainlayer/plumber :
woodfloat plaster with 1 coat plus 3 Stepped galvanized iron flushing All water taps to be cobra or equal approved.
coats exterior quality P.V.A paint
colour to Owner's approval
0.5mm Chroma deck sheets
All toilet pans and cisterns to be white close-couple
complete with white plastic seats.
Aluminum door frames White porcelain toilet roll holder recessed into wall.
All WHBs white pedestal by 'Beta.'
600mm wide x760mm mirror above every WHB.
Shop Retail White porcelain soap holder to every shower recessed
Screed
Provide mechanical ventilation
into brickwork 100 litre roof-mounted water heater.
One stainless steel vegetable prep. sink to kitchen.
Conc- service counter with tiles
FLOORS
-finishes to rooms as indicated on floor plans.
woodfloat plaster with 1 coat plus 3 300x300mm non-slip ceramic floor tiles to toilets
coats exterior quality P.V.A paint and bathrooms and kitchen.
colour to Owner's approval
SOUTH ELEVATION Ground floor slab on damp proof membraine
9270

WEST ELEVATION (polythen)on 20mm sand binding on back fill to


9040

structural Eng's specifications and approval.


15000

15000

Serving area scale 1:100 -all back fill to rceive anti-proof treatment and
Display shelves

scale 1:100 guarantee certificate to be issued by specialist.


Screed
Provide mechanical ventilation
windows :
Burglar bars to fixed and opening lights through out. Brick on
edge cill with dpc under to be put on each window
Precast concrete copping plastered
& painted as specified for the walls (See section)

ROOM VENTILATION
Display fridge Minimum of four airvents per room, exact positioning to be to builder's
discretion. Rooms without direct external ventilation to have either
115

0.5mm Chroma deck sheets perforated trap door or egg-crate ceiling or preferably mechanical
i.b.r sheets cladding
ventilation to be used.
115

0.5mm Chroma deck sheets


on steel canopy to ses's detail Marshal D. Shoko As shown
HDG002
Storeroom 2
Marshal D. Shoko
Storeroom 1 woodfloat plaster with 1 coat plus 3
3000

3000

coats exterior quality P.V.A paint


Screed colour to Owner's approval AS SHOWN July 2025

M Ndlovu HRDC/PG01
230

A21 Mzilikazi
woodfloat plaster with 1 coat plus 3 Bulawayo
woodfloat plaster with 1 coat plus 3 coats exterior quality P.V.A paint
coats exterior quality P.V.A paint colour to Owner's approval
0774987706
colour to Owner's approval [email protected]
230

720 1620 990 1020 1650


CLIENT
X

6000
EAST ELEVATION NORTH ELEVATION PROJECT

FLOOR PLAN scale 1:100 scale 1:100 DRAWING DISCRIPTIONS