0% found this document useful (0 votes)
11 views5 pages

MIT300 DS en

The Megger MIT300 series consists of insulation and continuity testers that are user-friendly, durable, and equipped with safety features. They offer various models with different voltage testing capabilities, data storage, and downloading options, suitable for domestic and industrial applications. Each model meets international safety standards and includes a warranty, making them reliable tools for electrical testing.

Uploaded by

etechquery
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views5 pages

MIT300 DS en

The Megger MIT300 series consists of insulation and continuity testers that are user-friendly, durable, and equipped with safety features. They offer various models with different voltage testing capabilities, data storage, and downloading options, suitable for domestic and industrial applications. Each model meets international safety standards and includes a warranty, making them reliable tools for electrical testing.

Uploaded by

etechquery
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

MIT300 Series

Insulation and Continuity Testers

„ Extremely easy to use


„ Tough rubber armoured case
„ Self contained protective cover
„ Live circuit warning
„ Weatherproof to IP54
„ Intelligent Safety System for protection.
„ Result storage and downloading
„ Download software included
„ USB interface

DESCRIPTION „ Continuity and buzzer testing starts automatically on


The Megger MIT300 series features: connection to the circuit.
Digital or Analogue: The Megger MIT300, MIT310 and „ Insulation tests being activated from the instrument or
MIT320 all feature the popular Megger digital/analogue the switch probe, supplied with MIT320 and MIT330
display. Large 20mm high characters provide very clear (not suitable for the use with the MIT300 or MIT310).
readout, combined with an analogue arc for the feel of an
Back lighting:-
analogue instrument, with a true analogue response.
„ Both the display and the range selected can be read in
The Megger MIT310A has a moving coil display for the dark because the MIT 320/330 has a backlit display
those who prefer a real moving needle. Black decals on a and range selection.
white background give high contrast, even in poor light Safety features:-
conditions. To protect the user and the tester from incorrect use the
Tough:- MIT series all have an extensive range of features known as
„ Designed to take the bashing that testers receive on site, the Megger Intelligent Safety System including:
the Megger MIT insulation testers are rubber armoured.
„ Safety Interlock – prevents unsafe connection of test
„ The rigid display cover folds right out of the way during leads
testing and locks down to protect the display when it is
„ Safe contact detectors – Even if the MIT is connected to
finished.
a live circuit whilst on continuity setting the tester will
Simple to use:- remain safe and not be damaged.
„ No buried functions mean it is obvious how to use the
„ Live voltage warning – alerts the operator when a circuit
Megger MIT.
voltage over 25 V exists.
„ Colour coded ranges help test selection, reducing
„ Safety lockout – Prevents the test from operating when
testing time and help with fault location.
the circuit voltage is >50 V.
„ A user guide in the lid provides all the basic information.
„ Continuity check – prevents a continuity test or buzzer
Hands free use:– test on a live circuit.
„ It hangs comfortably around the neck for hands-free use
The MIT300, 310, 320 and 330 meet or exceed the UK and
because the instrument is carefully balanced.
International Wiring Regulations, including requirements
MIT300 Series
Insulation and Continuity Testers
of BS7671 and VDE 0413 parts 1 and 4, HD 384, IEC 364, SPECIFICATIONS
NFC15-100, NEN3140, ES59009 and EN 61557. INSULATION RANGES
In addition the range meets the requirements of IEC 61010- Nominal Test Voltage
1 for safe connection to a 440 V Installation Category III MIT310, 310A, 320, 330 1000 V, 500 V, 250 V (d.c.)
supply (600 V Phase to Earth). MIT300 500 V, 250 V (d.c.)

The MIT330 additionally offers the facility to save test results


to internal memory. Over 1000 result can be saved on site, Terminal Characteristics
and downloaded to a computer when convenient. Data
is stored in non-volatile memory, being retained when the
instrument is switched off or batteries are exhausted.
A Job reference number can be selected for a range of
results, allowing separate locations to be tested with the
same tester and easily separated when downloaded.
A memory bar graph acts as a ‘Fuel Gauge’ showing how
much memory has been used.
Test results are downloaded to CSV (Coma Separated
Variable) spreadsheets, and can be imported into Microsoft
Excel. If certificates or reports are required, the results can be MEASURING RANGE
downloaded directly into Megger Powersuite Professional
All instruments 10 kΩ - 999 MΩ on all ranges
with a range of features for creating professionally finished
documentation. Short Circuit Current 1.5 mA nominal
Test Current on Load 1 mA at min. pass values of
APPLICATION insulation (as specified in BS7671,
HD 384 and IEC 364)
The MIT300 series has applications in all aspects of
domestic, commercial and industrial electrical contracting,
Accuracy (at 20 °C)
building maintenance, testing, inspection and servicing.
MIT300, 310, 320, 330 ±3%, ±2 digits up to 10 MΩ, ±5%
Combining both Insulation testing and continuity testing, up to 100 MΩ, ±30% up to full
each instrument caters for all aspects of fixed wiring scale
installations. MIT310A <2.5% of scale length (or 30% of
reading 200 kΩ to 10 MΩ)
Further applications can be found in panel building, testing
of motors, generators, switchgear and power tools, street
CONTINUITY RANGES
lighting and low volume manufacturing environments etc.
Measuring Range: 0,01 Ω - 99,9 Ω (0 -50 Ω on
All the MIT300 (except MIT310A) range is supplied with a analogue scale)
full 3 years warranty. Open Circuit Voltage: 5 V ±1 V
Short Circuit Current
MIT300, 310, 320, 330 205 mA +10 mA –5 mA
MIT310A 200 - 250 mA
Accuracy (at 20 °C)
MIT300, 310, 320,330 ±3% ±2 digits
MIT310A ±2.5% of scale length (or 30% of
reading 0.2 Ω to 2 kΩ)
Measuring range 0 - 2 / 20 / 200 / 2 kΩ
Open circuit voltage 1.5 V +/-0.5 V
MIT300 Series
Insulation and Continuity Testers
Zero Offset Adjust Phases P1, P2, P3
MIT300, 310,320, 330 0 - 9 Ω Last recorded result may be recalled to the display.
MIT310A 0 - 0.5 Ω
All data can be downloaded to a PC using Download
Continuity Buzzer Manager (supplied) or Megger Powersuite Professional of
MIT300, 310 Operates at <5 Ω Windows software
MIT320, 330 Adjustable 1 Ω to 20 Ω
MIT310A Operates at <5 Ω Communications USB interface
MIT300, 310, 320, 330 Response time <20 ms Environmental Protection:
MIT310A Response time <100 mS IP54
Resistance range MIT320/330 Fuses
Terminals 500 mA (F) 600 V, 32 x 6 mm Ceramic HBC 10
(can be used for diode testing) kA minimum.
Measuring Range: 10 Ω - 1 MΩ Display shows if fuse is ruptured.
Open Circuit Voltage: 5 V Safety
Short Circuit Current: 1.5 mA Meets the requirements of IEC61010-1 CAT III 600 V phase
Accuracy (at 20° C): ±5% ±2 digits up to 100 kΩ to earth.
Measuring Range (MIT310A) Automatic discharge
0 - 2 kΩ (refer to continuity) After an insulation test the item under test will be
Voltage range discharged automatically. Any voltage present will be
Measuring Range: 0 - 600 V a.c. (50/60 Hz) or d.c. indicated on the display so that the discharge can be
monitored.
Accuracy (at 20 °C)
Power supply
MIT310, 320, 330 d.c. or a.c. (50/60 Hz):
±1%, ±2 digits Battery:

MIT310A ±2.5% of scale length for 8 x 1,5 V cells IEC LR6 type (AA alkaline).
50/60 Hz Rechargeable NiCd or NiMH cells may be used.
Temperature coefficient: Battery condition is constantly shown on the display as a
<0,1% per °C on all ranges. four-section bargraph.
Default voltmeter all modes except off Battery Life
MIT310, 320, 330 >25 V a.c. or d.c. is applied display 5000 consecutive tests (5 seconds per test) on any test
will operate as a voltmeter. using 2 Ah batteries.
MIT300 Beeps and flash ‘V’ on the display Weight
MIT310A All modes including OFF All units: 980 gms
Test inhibit: If more than 50 volts is detected, Dimensions
testing will be inhibited. All units: 203 x 148 x 78 mm
AutoPower Down (MIT310, 320, 330) (8 x 5.7 x 3.2 inches)
Auto power down operates after 10 minutes if left in E.M.C. In accordance with IEC61326-1
standby mode.
Temperature and humidity
Operating Range: -10 °C to +60 °C
Operating Humidity: 93% R.H. at +40 °C max.
Storage Range: -25 °C to +70 °C
Test Result Storage (1000 results)
Job Number 255 locations
Distribution Board no.99 locations
Circuits 99 locations
MIT300 Series
Insulation and Continuity Testers
MIT300 SERIES BENEFITS

MIT300 MIT310 MIT310A MIT320 MIT330


Analogue
Insulation testing
250 V n n n n n
500 V n n n n n
1000 V n n n n
Test range 999 MΩ 999 MΩ 999 MΩ 999 MΩ 999 MΩ
Insulation limit alarm (0.01 MΩ to 1 Ω) n n
Continuity testing
Continuity to 100 Ω n n n n n
Continuity buzzer n n n n n
Lead null to 9 Ω n n 0.5 Ω n n
Adjustable buzzer 1 to 20 Ω n n
Audible buzzer disable n n
Voltage measurement
Volts AC/DC 600 V 600 V 600 V 600 V
Resistance measurement
10 Ω to 1 MΩ range n
Features
Voltage warning n
Default voltmeter n n n n
Backlit display n n
Backlight selector ranges n n
Locking test button n n n n n
Auto powerdown n n n n
Switched test probe n n
IP54 weatherproof n n n n n
Accepts rechargeable batteries n n n n n
1000 Test result storage n
Downloading n
Calibration certificate n n n n
3 years warranty n n n n
MIT300 Series
Insulation and Continuity Testers

ORDERING INFORMATION
Description Part number Description Part number
Product Optional accessories
MIT300 250 V, 500 V insulation tester MIT300-EN Fused test lead set 1002-015
MIT310 250 V, 500 V, 1000 V insulation tester MIT310-EN
MIT310A 250 V, 500 V,1000 V
analogue insulation tester MIT310A-EN
MIT320 250 V, 500 V, 1000 V insulation tester MIT320-EN
MIT330 250 V, 500 V, 1000 V insulation tester MIT330-EN
Included accessories
Test lead set and crocodile clips 1002-001
SP4F Switch probe (MIT320 and MIT330 only) 1007-156

SALES OFFICE MIT300_DS_en_V16


Megger Limited www.megger.com
Archcliffe Road Dover ISO 9001
CT17 9EN England The word ‘Megger’ is a registered trademark
T +44 (0) 1304 502101
E [email protected]

You might also like