3 Introduction to infrared sensors
3 Types of OMEGA infrared sensors
4-5 Considerations when selecting a device
6 Emissivity application table
7 Application examples
Fixed mount infrared sensors
8-9 Infrared sensors with optional displays
10-17 Fixed infrared sensors for integrated systems
Hand-held infrared sensors and devices
18 Video hand-held infrared
18 Clamp meter with thermocouple
19 Laser infrared guns
20 Pocket size laser infrared
20 Infrared scanner
21 Infrared with thermocouple input
22-23 Economic infrared guns
Introduction to OMEGA
infrared temperature sensors
When to use an infrared thermometer tripod mount. OMEGA offers a large variety of
Infrared measuring devices have many advantages laser thermometers in various shapes and form
over other temperature measurement thermometers. factors. Many of OMEGA hand-held devices
These include taking high temperature measurement feature OMEGA’s patented Circle Dot/Circle Laser
in environments that do not allow the use of infrared thermometer which clearly outlines the
thermocouples, and also measurements which must not field of view of the gun. Hand-held units with an
be in direct contact with devices. attached thermocouple probe is another option.
Infrared devices also allow the measurement of moving Fixed Mount IR
objects and also can measure surfaces with low thermal Thermometers
conduction and capacity. A fixed mount infrared
thermometer is commonly
used in industrial processes
How do infrared devices work? where the thermometer
Substances with temperatures above absolute zero emit can be mounted in a stationary position, and
infrared radiation (spectral range of wavelengths from output their temperature signals to a control or
0.7 to 1000µm). This range is not visible to the human data acquisition system. For very hot or dirty
eye. The most useful infrared measurements are located environments, instruments can be equipped with
between 0.7 and 20µm. water or thermoelectric cooling to keep internal
electronics cool. Units can also be supplied with
The optical system of an infrared thermometer captures optional air or water jackets.
the energy emitted from an object. This is performed
from a circular measuring spot and is then focused Integrated Systems
onto a detector. The energy captured by the detector is
Compete IR systems are also
electronically amplified and converted into an electrical
available, they consist of an
signal. The optical resolution results from the ratio of the
infrared sensor, display and
measuring distance to the size of the measuring spot.
alarms.
The measuring spot must always be smaller than the test
object or the measuring point of interest. The higher the These systems are compact,
optical resolution the smaller the measuring spots can be making them ideal for mounting in tight spaces.
measured at further distances High ambient versions are capable of withstanding
temperatures of up to 180°C without water or
air cooling, allowing significant energy and cost
Types of infrared sensors savings to be made.
Infrared Thermocouples Many different outputs are available to suit the
An infrared thermocouple is a low- needs of different users and environments.
cost infrared thermometer that
measures surface temperature of Two-Color Systems
materials without contact. It can be For use in applications where
directly installed on conventional the target may be obscured
thermocouple controllers, by dust, smoke or similar
transmitters and digital readout devices as if it were a contaminants, or changing
replacement thermocouple. An infrared thermocouple emissions as in “pouring
can be installed in a fixed, permanent location, or used metals,” a two-color infrared thermometer is
with a hand-held probe. ideal. It measures temperature independently of
emissivity. Systems are available with fiber optic
Hand-held Infrared Thermometers sensors, or can be based on a fixed or hand-held
Infrared thermometer guns are configurations.
one of the most popular type of
units. They are commonly used for
portable applications although some
models also feature an integral
3
Considerations when
selecting an infrared device
Before choosing an infrared device, it is important to have a clear understanding
of the application requirements.
C
O
What is the temperature range of your process?
What size is the target?
How close to the target can the instrument be installed?
Does the target fill the field of view?
What is the emissivity of the target material?
How fast is the target moving?
What is the ambient temperature?
Is there any steam, smoke or dusty in the application?
Do you want to connect control equipment?
Do you need a data logging function?
4
Considerations when
selecting an infrared device
Field of View Objects with very low emissivity (below 0.2) can be
difficult applications. Some polished, shiny metallic
The field of view of an infrared surfaces, such as aluminum, are so reflective in the
sensor defines the size of infrared that accurate temperature measurements are
the measurement target at a not always possible.
specified distance from the
sensor.
Spectral response
The spectral response of the unit is the width of the
Each type of IR sensor has a specific field of view,
infrared spectrum covered. Most general purpose units
such as 10:1, 20:1 or 40:1. These numbers show the
use a wide-band filter in the 8 to 14 micron range.
ratio between: the distance of the sensor from the
This range is preferred for most measurements, as
measurement target (the number on the left); and
it will allow measurements to be taken without the
the target spot size (the number on the right).
atmospheric interference.
Some units use wider filters such as 8 to 20 microns,
which can be used for close measurements, but are
For example, a 20:1 IR positioned 200cm from a ‘‘distance-sensitive’’ against longer distances.
brake can ‘see’ a target spot of diameter 10cm. At
300cm away, the spot size would be 15cm. This is
For special purposes, very narrow bands may be
the sensor’s field of view.
chosen. These can be used for higher temperatures,
and for penetrations of atmosphere, flames, and gases.
Emissivity Typical low band filters are at 2.2 or 3.8 microns. High
All values of emissivity fall temperatures above 800°C are usually measured with
between 0.0 and 1.0. Emissivity 2.1 to 2.3 micron filters.
is defined as the ratio of the
energy radiated by an object If the temperature is measured through a glass or
at a given temperature to the quartz window, the infrared device must have a
energy emitted by a perfect radiator, or blackbody, at wavelength where the glass is somewhat transparent,
the same temperature. The emissivity of a blackbody which means they can only be used for high
is 1.0. Most infrared thermometers can compensate temperature.
for different emissivity values, for different materials.
In general, the higher the emissivity of an object,
the easier it is to obtain an accurate temperature See our Emissivity and Spectral response table on
measurement using infrared. the next page for a better idea of your applications
properties.
5
Spectral Response/Emissivity
Application Table
This table can be used to gain an idea of what values your application may have.
For example,a mirror has a low emissivity of 0.1 while a so-called ´black body´ has a high emissivity of 1.
A black body is an ideal radiator, which absorbs the whole radiation of all wavelengths and which does not reflect
nor transmit any radiation. The surface of a full radiator has a uniform emissivity of 1.
Many non-metals such as wood, rubber, stone, and organic materials have only low reflecting surfaces and, as a
result, high emissivities between 0.8 and 0.95. However, metals, especially if they have glossy surfaces, can have
emissivity values of 0.1.
This table data only represents average values, as the emissivity of a material is influenced by various factors.
These include: temperature and surface geometry.
Spectral Response Emissivity Application
Black body object
8 to 14 µm 1
(no reflective properties)
8 to 14 µm 0.95 Wood and paper
8 to 14 µm 0.91 Concrete
8 to 14 µm 0.87 Oxidised copper
3 to 5 µm 0.7 Heated up glass, sealing, laminating
Ferrous and non-ferrous metals,
2 to 3 µm 0.5
induction furnaces, glass
1 to 6 µm 0.10 Polished ceramics
1 µm 0.3 Polished Chrome
Polish Silver
1 µm 0.01
(or other highly reflective object)
6
Applications for infrared devices
OMEGA infrared products are used in many applications in manufacturing, food processing, medicine, aerospace,
and science, to name a few. Our highly qualified sales and application engineers are at your service to guide you
through our extensive range of products. Give us a call to discuss your application needs.
Food
The temperature of food products is easy to measure using
infrared devices, as they are usually non-reflective.
OMEGA fixed mount laser thermometers can be installed in a
location to continuously monitor a process.
Permanently mounted devices are generally installed on
a manufacturing or process control line, and output their
temperature signals to a control or data acquisition system.
Omega OS136 is an ideal solution for process lines. This
sensor comes with measurement ranges
18 to 202°C or 149 to 538°C.
https://www.omega.co.uk/OS136
Iron and Steel
The surface condition of iron and steel can vary during the
manufacturing process, even when viewed at the same
position. Along with the reflective metal surface, this has
traditionally made it difficult to measure the temperature of
reflective materials. OMEGA has a range of short-wavelength
sensors designed for the task of iron and steel manufacture.
The OS-MINI has a miniature sensing head to fit most
applications. This uses short wavelength measurement for
low-emissivity targets such as steel rollers and other metal
surfaces.
https://www.omega.co.uk/OS-MINI22
Automotive Testing
OMEGA provides a comprehensive range of thermal
cameras, infrared guns and infrared transmitters suitable
for remote temperature measurement and analysis.
The featured OS730K unit has a range of -50 to 800°C,
a Type K thermocouple input, and is ideal for engine
temperature monitoring. Many different styles are
available on our website.
https://www.omega.co.uk/automotive
7
Fixed Mount Infrared Sensors
with Optional Touch Screen Display
OS-MINI Series MINIATURE SENSOR WITH OPTIONAL
TOUCH SCREEN DISPLAY
The OS-MINI has adjustable emissivity setting on all models,
suitable for a wide range of target materials such as paper,
plastics, food, painted surfaces, and many more. Optional
touch screen display available.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.20 to 1.00
Spectral response 8 to 14 µm
Field of view up to 30:1
Output 4 to 20 mA or RS485 Modbus®
es.omega.com/os-mini
OS-MINI22 Series HIGH TEMPERATURE MINIATURE SENSOR
WITH OPTIONAL TOUCH SCREEN DISPLAY
Ideal for extreme temperature environments, the OS-MINI22
has short wavelength measurement for low-emissivity targets
such as steel rollers and other Metal surfaces. Optional touch
screen available.
Range 100 to 2000°C
Accuracy ± 1%
Emissivity 0.20 to 1.00
Spectral response 2.0 to 2.6 µm
Field of view up to 75:1
Output 4 to 20 mA or RS485 Modbus®
es.omega.com/os-mini22
8
Fixed Mount Infrared Sensors
with Optional Touch Screen Display
OS-PC HIGH SPEED INFRARED SENSOR
WITH SMALL MEASURED FIELD OF VIEW SIZE
The OS-PC cube is an infrared pyrometer with an extremely
fast response time and a very small measurement area size.
Designed for extremely fast response times, or where the
object to be measured is very small.
Range 0 to 500°C
Accuracy ± 1%
Emissivity 0.3 to 1.0
Spectral response 82 to 7 µm
Field of view up to 30:1
Output 4 to 20 mA or RS485 Modbus®
www.omega.co.uk/os-pc
OS-MINIHUB MULTI-CHANNEL INFRARED TEMPERATURE
MONITORING SYSTEM RS485/MODBUS
OS-MINIHUB sensors are designed to measure the surface
temperature of non-reflective materials, from -20 to 1000°C.
They are sealed to IP65, built from 316 stainless steel, and
fully tested to industrial EMC standards.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.2 to 1.0
Spectral response 8 to 14 µm
Field of view up to 75:1
Output 4 to 20 mA or RS485 Modbus®
www.omega.co.uk/os-minihub
9
Fixed Mount Infrared Sensors
for Integrated Systems
OS-MINIUSB MINIATURE SENSOR THAT MEASURES THE
SURFACE TEMPERATURE OF A SOLID OR LIQUID
The OS-MINIUSB is a miniature infrared sensor that measures
the surface temperature of a solid or liquid without contact. It can
measure non-metal surfaces between -20 and 1000°C, with a
response time of just 125 ms.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.2 to 1.0
Spectral response 8 to 14 µm
Field of view 2:1 or 20:1
Output USB
www.omega.co.uk/os-miniusb
OS301A-USB COMPACT INFRARED TEMPERATURE
TRANSMITTER
OS301A-USB is specially designed for distant targets and has
an optical resolution of 30:1. It measures temperatures from
-40 to 1000°C accurately and consistently, with an outstanding
response time of 240 mS.
Range - 40 to 1000°C
Accuracy ± 1%
Emissivity 1.0
Spectral response 2.0 to 2.4 µm
Field of view 30:1
Output USB, 4 to 20 mA
www.omega.co.uk/os151-usb
10
Fixed Mount Infrared Sensors
for Integrated Systems
OS150-2USB PC CONFIGURABLE INFRARED
TEMPERATURE SENSOR
PC configurable temperature range, short-wavelength measure-
ment for low emissivity targets such as steel rollers and other
metal surfaces, even at low temperatures.
Range 45 to 2000°C
Accuracy ± 1%
Emissivity 0.1 to 1.0
Spectral response 2.0 to 2.4 µm
Field of view up to 75:1
Output 0 to 20 mA or 4 to 20 mA
www.omega.co.uk/os150-2usb
OS210 LOW-COST INFRA RED TEMPERATURE
SENSOR/TRANSMITTER
This Series is a range of high quality, low cost, compact sensors
which measure the temperature of inaccessible or moving objects
and materials with an outstanding response time of 240 ms
Range -20 to 500°C
Accuracy ± 1%
Emissivity Fixed at 0.95
Spectral response 8 to 14 µm
Field of view up to 30:1
Output 0 to 20 mA or 4 to 20 mA
www.omega.co.uk/OS210-150-300-800
11
Fixed Mount Infrared Sensors
for Integrated Systems
OS136A LOW-COST FIXED INFRARED TEMPERATURE
SENSOR AND TRANSMITTER
This mini transmitter is ideal for applications that require measur-
ing temperature in hard-to-reach, confined or harsh environment
areas. Comes with a shielded cable.
Range -18 to 202°C or 149 to 538°C
Accuracy ± 3%
Emissivity Fixed at 0.95
Spectral response 5 to 14 µm
Field of view 6:1
Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, type K
thermocouple, 10 mV/degree analogue
www.omega.co.uk/os136a
OS137A FIXED INFRARED TEMPERATURE SENSOR
AND TRANSMITTER
3 Temperature Ranges Available: OS137A-1: 0 to 100°C
(32 to 212°F) OS137A-2: -18 to 260°C (0 to 500°F)
OS137A-3: -18 to 538°C (0 to 1000°F)
Range -18 to 538°C
Accuracy ± 1.5%
Emissivity 0.5 to 1.0
Spectral response 8 to 14 µm
Field of view 10:1
Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, type K
thermocouple, 10 mV/degree analogue
www.omega.co.uk/os137a
12
Fixed Mount Infrared Sensors
for Integrated Systems
OS36-2 COMPACT INFRARED SENSOR AND
AIR PURGE HEAD
The OS36-2 internal air purge passages provide a convenient
and highly efficient method of maintaining optical cleanliness in
harsh environments.
Range -18 to 250°C
Accuracy ± 2%
Emissivity 0.8 to 1.0
Spectral response 6.5 to 14 µm
Field of view 2:1
Output J, K, E, or T Thermocouple
www.omega.co.uk/os36-2
OS36 Series INFRARED THERMOCOUPLES
The OS36 produces a thermocouple output signal that can be
used with any standard J, K, T or E thermocouple instrumenta-
tion. The thermocouple’s accuracy is specified for target emissivi-
ty between 0.8 and 1.0.
Range -18 to 250°C
Accuracy ± 2%
Emissivity 0.8 to 1.0
Spectral response 6.5 to 14 µm
Field of view 1:1
Output J, K, E, or T Thermocouple
www.omega.co.uk/OS36
13
OS36 Infrared Sensor Accessories
OS36-APC COOLING JACKET KIT FOR OS36 AND OS36-2
INFRARED THERMOCOUPLES
The OS36-APC needs water flow rate of only 0.05 gpm (190 cc/
min.) to protect an infrared thermocouple at 540°C (1000°F).
This kit makes it possible to use either the OS36 or OS36-2 with
air, water or both for service in harsh environments.
Range 0 to 540°C
Accuracy NA
Emissivity NA
Spectral response NA
Field of view NA
Output NA
www.omega.co.uk/os36-apc
OS36-GMK GOOSE NECK MOUNTING KIT FOR OS36 SERIES
INFRARED THERMOCOUPLES
For fast and convenient mounting of OS36 Series infrared ther-
mocouples. Heavy duty design provides excellent stiffness for
reliable positioning.
Range 0 to 540°C
Accuracy NA
Emissivity NA
Spectral response NA
Field of view NA
Output NA
www.omega.co.uk/os36-gmk
14
Fixed Mount Infrared Sensors
for Integrated Systems
OS36-01 FIXED MOUNT INFRARED THERMOCOUPLES
WITH ABS PLASTIC HOUSING
These units feature an exceptionally strong, hermetically sealed
ABS plastic housing that makes non-contact infrared temperature
measurement more economical.
Range -18 to 250°C
Accuracy ± 2%
Emissivity 0.8 to 1.0
Spectral response 6.5 to 14 µm
Field of view 1:1
Output J, K, E or T Thermocouple
Output Signal
www.omega.co.uk/os36-01
OS36-3-K-1200F RUGGED INFRARED NON-CONTACT
TEMPERATURE SENSOR
The OS36-3-K-1200 is ideal for use in extreme ambient
temperature applications. Maintains accuracy with thermal shock.
High pressure and vacuum compatible.
Range -45 to 650°C
Accuracy ± 1%
Emissivity 0.90
Spectral response 6.5 to 14 µm
Field of view 3:1
Output Type K thermocouple output
www.omega.co.uk/os36-3-k-1200f
15
Fixed Mount Infrared Sensors
for Integrated Systems
OS36-3-RF REFRIGERATED FOODS ENVIRONMENTS
INFRARED TEMPERATURE SENSOR
Idea for use in refrigerated foods environments. Highly reliable
(minimal downtime), hermetically sealed, immersible for wash
downs, and with built-in air purge.
Range -18 to 38°C
Accuracy ± 3.5%
Emissivity 0.90
Spectral response 6.5 to 14 µm
Field of view 3:1
Output 0 to 10 Vdc
www.omega.co.uk/os36-3-rf
OS36-3 RUGGED INFRARED THERMOCOUPLE WITH
INTEGRAL AIR COOL/PURGE HEAD
The OS36-3 Series is ideal for use in paint or ink environments
in which the sensor is mounted remotely from the target. Also
equipped with an internal air cool/purge system
Range -18 to 250°C
Accuracy ± 2%
Emissivity 0.8 to 1.0
Spectral response 6.5 to 14 µm
Field of view 3:1
Output J, K, E or T Thermocouple
Output Signal
www.omega.co.uk/os36-3
16
Fixed Mount Infrared Sensors
for Integrated Systems
OS38 ADJUSTABLE RANGE INFRARED SENSOR WITH
INTEGRAL AIR COOL AND PURGE HEAD
The OS38 units offer a choice of 10:1, 20:1 or 100:1 optics. It
features a built-in air purge collar that conveniently and efficiently
maintains optical cleanliness in harsh environments. Great for
clean metals.
Range 27 to 93°C
Accuracy ± 2%
Emissivity 0.8 to 1.0
Spectral response 0.1 to 5 µm
Field of view 10:1, 20:1 or 100:1
Output J or K Thermocouple Output Signal; R or S
Type for 100:1 Models
www.omega.co.uk/os37_os38
OSAT INTRINSICALLY SAFE INFRARED
TEMPERATURE SENSOR
Suitable for hazardous areas, zone 0, 1 and 2 (gas), and
zone 20, 21 and 22 (dust), with a suitable intrinsically safe
isolator
Range -20 to 500°C
Accuracy ± 1%
Emissivity 0.20 to 1.00
Spectral response 8 to 14 µm
Field of view up to 30:1
Output 4 to 20 mA
www.omega.co.uk/osat
17
Hand-held Infrared Sensors
OS-VIR50 DIGITAL INFRARED VIDEO THERMOMETER
FOR EXTREME TEMPERATURES
Capable of making infrared and contact (thermocouple)
temperature measurements, the built-in camera offers still image
and video capturing functionality for documenting measurement
locations.
Range -50 to 2200°C
Accuracy ± 1% to ± 3%
Emissivity 0.1 to 1 (0.001 increment)
Spectral response 8 to 14 µm
Field of view 50:1
Live video window. Output USB, SD Card Storage
www.omega.co.uk/os-vir50
HHM-EX623 CLAMP METER 400 A DUAL INPUT WITH
INFRARED THERMOMETER AND VOLTAGE
The HHM-EX623 is a True RMS Clamp Meter with built-in dual
thermocouple inputs for T1, T2, and T1-T2 differential temperature
measurement and non-contact infrared thermometer..
Range -50 to 270°C
Accuracy ± 2%
Emissivity 0.95 fixed
Spectral response 6 to 16 µm
Field of view 8:1
Output -
www.omega.co.uk/hhm-ex623
18
Hand-held Infrared Sensors
OS758-LS DUAL LASER INFRARED THERMOMETER
The OS758-LS offers a rugged design that is shatter-proof at
1 metre. A Type K thermocouple input is included for contact
measurements, often used to verify emissivity.
Range -35 to 1600°C
Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)
Spectral response 8 to 14 µm
Field of view 60:1
Output SPI, USB, SD Card Storage
es.omega.com/os758-ls
OS768-LS DUAL NON-CONTACT LASER HIGH
TEMPERATURE INFRARED THERMOMETER
Accurately verify surface temperatures, can also input Type K
thermocouple input (free T/C included) for high precision meas-
urement of contact surfaces, gases, and liquids.
Range 100 to 1800°C
Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)
Spectral response 8 to 14 µm
Field of view 75:1
Output USB
es.omega.com/os768-ls
19
Hand-held Infrared Sensors
OS-PEN9 POCKET SIZE INFRARED THERMOMETER
WITH CIRCLE LASER
These Infrared pens include: 9:1 optical ratio with circular laser,
an ergonomic double injection casing for comfortable holding and
measuring, and a backlit LCD. Just point, press, and read the
display.
Range 33 to 500°C
Accuracy ± 2%
Emissivity 0.95 (fixed)
Spectral response 6 to 14 µm
Field of view 9:1
Output -
www.omega.co.uk/os-pen9
OM-144 TEMPERATURE/HUMIDITY DATA LOGGERS
WITH USB INTERFACE
The OM-144 is a low cost, compact, battery powered temper-
ature and humidity data logger, capable of unattended logging
of the ambient temperature and relative humidity (RH) of an
environment for days, weeks or months.
Range –20 to 250°C
Accuracy ± 3%
Emissivity 0.95 (fixed)
Spectral response -
Field of view 2:1
Output USB, 10,000 Readings
www.omega.co.uk/om-140-series
20
Hand-held Infrared Sensors
OS423HT-LS INTRINSICALLY SAFE INFRARED
TEMPERATURE SENSOR
OS423HT-LS offers laser sighting, several mathemati-
cal modes, and adjustable emissivity. Long battery life,
(typical 180 hours without laser or backlight), is obtained
from 2 “AAA” batteries (included).
Range -60 to 1000°C
Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)
Spectral response 8 to 14 µm
Field of view 30:1
Output -
www.omega.co.uk/os423-ls
OS1327D INFRARED THERMOMETER WITH
USB INTERFACE
The OS1327D features adjustable emissivity, laser sighting,
backlit LCD, 12:1 field of view, max, minimum,average,
differential temperature monitoring, high/low audible alarms,
temperature and data storage.
Range -35 to 500°C
Accuracy ± 2%
Emissivity 0.17 to 1
Spectral response 6 to 14 µm
Field of view 12:1
Output Reading Storage
www.omega.co.uk/os1327d
21
Hand-held Infrared Sensors
OS418-LS NON-CONTACT INFRARED THERMOMETER
WITH RELATIVE HUMIDITY
Accurately verify surface temperatures, can also input Type K
thermocouple input (free T/C included) for high precision meas-
urement of contact surfaces, gases, and liquids.
Range -60 to 500°C
Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)
Spectral response 8 to 14 µm
Field of view 12:1
Output -
www.omega.co.uk/os418-ls
OS543 LOW COST INFRARED THERMOMETER GUN
Low cost infrared thermometers offer solutions for many non-con-
tact temperature measurement applications. Applications include:
Electrical, Asphalt, HVAC, Automotive, In-Process Temperature
Measurement, Fire and Safety.
Range -30 to 550°C
Accuracy ± 2%
Emissivity 0.95 (fixed)
Spectral response 6 to 14 µm
Field of view 10:1
Output -
www.omega.co.uk/os540
22
Handheld Infrared Sensors
OS561 LOW COST INFRARED THERMOMETER GUN
The OS561 is an economical tool for temperature measure-
ments. It features a user-friendly 2-key operation, and max and
hold modes. The backlit LCD screen and the laser stay on when
the trigger is depressed.
Range -60 to 500°C°C
Accuracy ± 2%
Emissivity 0.95 (fixed)
Spectral response 8 to 14 µm
Field of view 10:1
Output -
www.omega.co.uk/os561
OSXL-TG165 INFRARED TEMPERATURE CAMERA
Bridging the gap between single spot infrared thermometers and
infrared temperature cameras, the OSXL-TG165 gives you the
advantage of thermal imaging to help you discover temperature
issues you can’t see with typical spot radiometers.
Range -25 to 380°C
Accuracy ± 1.5%
Emissivity 4 pre-set levels with custom
adjustment, 0.1 to 0.99
Spectral response 8 to 14 µm
Field of view 24:1
www.omega.co.uk/osxl-tg165
23
European Headquarters
United Kingdom
Int: +44 (0) 161 777 6611
Free Phone: 0800 488 488
[email protected]omega.co.uk
Headquarters
United States
Int: 1-203-359-1660
US & Canada: 1-888-826-6342
[email protected]
omega.com
European Sales & Service
Benelux Germany
Int: (+31) 070 770 3815 Int: (+49) 07056-9398-0
Domestic: 07077 03815 Free Phone: 0800-8266342
[email protected] [email protected]
omega.nl omega.de
Denmark Italy
Int: (+45) 80 25 14 43 Int: (+39) 022 333 1521
Domestic: 80 25 14 43 Free Phone: 800 906 907
[email protected] [email protected]
dk.omega.com it.omega.com
France Spain
Int: (+33) 01 57 32 48 17 Int: (+34) 911 776 121
Free Phone: 0805 541 038 Free Phone: 800 900 532
[email protected] [email protected]
omega.fr es.omega.com
© COPYRIGHT 2017 OMEGA ENGINEERING,LTD. ALL RIGHTS RESERVED