0% found this document useful (0 votes)
12 views24 pages

UK OMEGA Infrared Ebook - Kopie

The document provides an overview of OMEGA's infrared measurement products, including various types of infrared sensors, their applications, and considerations for selection. It details fixed mount and hand-held infrared devices, their specifications, and suitable applications in industries such as food processing, automotive testing, and metal manufacturing. Additionally, it includes information on emissivity and spectral response, essential for accurate temperature measurements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views24 pages

UK OMEGA Infrared Ebook - Kopie

The document provides an overview of OMEGA's infrared measurement products, including various types of infrared sensors, their applications, and considerations for selection. It details fixed mount and hand-held infrared devices, their specifications, and suitable applications in industries such as food processing, automotive testing, and metal manufacturing. Additionally, it includes information on emissivity and spectral response, essential for accurate temperature measurements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

VIDEO DISPLAY LASER TRANSMITTERS IR SENSORS IR GUNS COMPLETE SYSTEMS

Infrared
Measurement
Products and application solutions

omega.co.uk
CONTENTS

3 Introduction to infrared sensors

3 Types of OMEGA infrared sensors

4-5 Considerations when selecting a device



6 Emissivity application table

7 Application examples

Fixed mount infrared sensors

8-9 Infrared sensors with optional displays

10-17 Fixed infrared sensors for integrated systems

Hand-held infrared sensors and devices

18 Video hand-held infrared

18 Clamp meter with thermocouple

19 Laser infrared guns

20 Pocket size laser infrared

20 Infrared scanner

21 Infrared with thermocouple input

22-23 Economic infrared guns


Introduction to OMEGA
infrared temperature sensors

When to use an infrared thermometer tripod mount. OMEGA offers a large variety of
Infrared measuring devices have many advantages laser thermometers in various shapes and form
over other temperature measurement thermometers. factors. Many of OMEGA hand-held devices
These include taking high temperature measurement feature OMEGA’s patented Circle Dot/Circle Laser
in environments that do not allow the use of infrared thermometer which clearly outlines the
thermocouples, and also measurements which must not field of view of the gun. Hand-held units with an
be in direct contact with devices. attached thermocouple probe is another option.

Infrared devices also allow the measurement of moving Fixed Mount IR


objects and also can measure surfaces with low thermal Thermometers
conduction and capacity. A fixed mount infrared
thermometer is commonly
used in industrial processes
How do infrared devices work? where the thermometer
Substances with temperatures above absolute zero emit can be mounted in a stationary position, and
infrared radiation (spectral range of wavelengths from output their temperature signals to a control or
0.7 to 1000µm). This range is not visible to the human data acquisition system. For very hot or dirty
eye. The most useful infrared measurements are located environments, instruments can be equipped with
between 0.7 and 20µm. water or thermoelectric cooling to keep internal
electronics cool. Units can also be supplied with
The optical system of an infrared thermometer captures optional air or water jackets.
the energy emitted from an object. This is performed
from a circular measuring spot and is then focused Integrated Systems
onto a detector. The energy captured by the detector is
Compete IR systems are also
electronically amplified and converted into an electrical
available, they consist of an
signal. The optical resolution results from the ratio of the
infrared sensor, display and
measuring distance to the size of the measuring spot.
alarms.
The measuring spot must always be smaller than the test
object or the measuring point of interest. The higher the These systems are compact,
optical resolution the smaller the measuring spots can be making them ideal for mounting in tight spaces.
measured at further distances High ambient versions are capable of withstanding
temperatures of up to 180°C without water or
air cooling, allowing significant energy and cost
Types of infrared sensors savings to be made.
Infrared Thermocouples Many different outputs are available to suit the
An infrared thermocouple is a low- needs of different users and environments.
cost infrared thermometer that
measures surface temperature of Two-Color Systems
materials without contact. It can be For use in applications where
directly installed on conventional the target may be obscured
thermocouple controllers, by dust, smoke or similar
transmitters and digital readout devices as if it were a contaminants, or changing
replacement thermocouple. An infrared thermocouple emissions as in “pouring
can be installed in a fixed, permanent location, or used metals,” a two-color infrared thermometer is
with a hand-held probe. ideal. It measures temperature independently of
emissivity. Systems are available with fiber optic
Hand-held Infrared Thermometers sensors, or can be based on a fixed or hand-held
Infrared thermometer guns are configurations.
one of the most popular type of
units. They are commonly used for
portable applications although some
models also feature an integral

3
Considerations when
selecting an infrared device

Before choosing an infrared device, it is important to have a clear understanding


of the application requirements.

C
O
What is the temperature range of your process?

What size is the target?

How close to the target can the instrument be installed?

Does the target fill the field of view?

What is the emissivity of the target material?

How fast is the target moving?

What is the ambient temperature?

Is there any steam, smoke or dusty in the application?

Do you want to connect control equipment?

Do you need a data logging function?

4
Considerations when
selecting an infrared device

Field of View Objects with very low emissivity (below 0.2) can be
difficult applications. Some polished, shiny metallic
The field of view of an infrared surfaces, such as aluminum, are so reflective in the
sensor defines the size of infrared that accurate temperature measurements are
the measurement target at a not always possible.
specified distance from the
sensor.
Spectral response
The spectral response of the unit is the width of the
Each type of IR sensor has a specific field of view,
infrared spectrum covered. Most general purpose units
such as 10:1, 20:1 or 40:1. These numbers show the
use a wide-band filter in the 8 to 14 micron range.
ratio between: the distance of the sensor from the
This range is preferred for most measurements, as
measurement target (the number on the left); and
it will allow measurements to be taken without the
the target spot size (the number on the right).
atmospheric interference.

Some units use wider filters such as 8 to 20 microns,


which can be used for close measurements, but are
For example, a 20:1 IR positioned 200cm from a ‘‘distance-sensitive’’ against longer distances.
brake can ‘see’ a target spot of diameter 10cm. At
300cm away, the spot size would be 15cm. This is
For special purposes, very narrow bands may be
the sensor’s field of view.
chosen. These can be used for higher temperatures,
and for penetrations of atmosphere, flames, and gases.
Emissivity Typical low band filters are at 2.2 or 3.8 microns. High
All values of emissivity fall temperatures above 800°C are usually measured with
between 0.0 and 1.0. Emissivity 2.1 to 2.3 micron filters.
is defined as the ratio of the
energy radiated by an object If the temperature is measured through a glass or
at a given temperature to the quartz window, the infrared device must have a
energy emitted by a perfect radiator, or blackbody, at wavelength where the glass is somewhat transparent,
the same temperature. The emissivity of a blackbody which means they can only be used for high
is 1.0. Most infrared thermometers can compensate temperature.
for different emissivity values, for different materials.
In general, the higher the emissivity of an object,
the easier it is to obtain an accurate temperature See our Emissivity and Spectral response table on
measurement using infrared. the next page for a better idea of your applications
properties.

5
Spectral Response/Emissivity
Application Table

This table can be used to gain an idea of what values your application may have.

For example,a mirror has a low emissivity of 0.1 while a so-called ´black body´ has a high emissivity of 1.
A black body is an ideal radiator, which absorbs the whole radiation of all wavelengths and which does not reflect
nor transmit any radiation. The surface of a full radiator has a uniform emissivity of 1.

Many non-metals such as wood, rubber, stone, and organic materials have only low reflecting surfaces and, as a
result, high emissivities between 0.8 and 0.95. However, metals, especially if they have glossy surfaces, can have
emissivity values of 0.1.

This table data only represents average values, as the emissivity of a material is influenced by various factors.
These include: temperature and surface geometry.

Spectral Response Emissivity Application

Black body object


8 to 14 µm 1
(no reflective properties)

8 to 14 µm 0.95 Wood and paper

8 to 14 µm 0.91 Concrete

8 to 14 µm 0.87 Oxidised copper

3 to 5 µm 0.7 Heated up glass, sealing, laminating

Ferrous and non-ferrous metals,


2 to 3 µm 0.5
induction furnaces, glass

1 to 6 µm 0.10 Polished ceramics

1 µm 0.3 Polished Chrome

Polish Silver
1 µm 0.01
(or other highly reflective object)

6
Applications for infrared devices
OMEGA infrared products are used in many applications in manufacturing, food processing, medicine, aerospace,
and science, to name a few. Our highly qualified sales and application engineers are at your service to guide you
through our extensive range of products. Give us a call to discuss your application needs.

Food
The temperature of food products is easy to measure using
infrared devices, as they are usually non-reflective.
OMEGA fixed mount laser thermometers can be installed in a
location to continuously monitor a process.
Permanently mounted devices are generally installed on
a manufacturing or process control line, and output their
temperature signals to a control or data acquisition system.
Omega OS136 is an ideal solution for process lines. This
sensor comes with measurement ranges
18 to 202°C or 149 to 538°C.

https://www.omega.co.uk/OS136

Iron and Steel


The surface condition of iron and steel can vary during the
manufacturing process, even when viewed at the same
position. Along with the reflective metal surface, this has
traditionally made it difficult to measure the temperature of
reflective materials. OMEGA has a range of short-wavelength
sensors designed for the task of iron and steel manufacture.

The OS-MINI has a miniature sensing head to fit most


applications. This uses short wavelength measurement for
low-emissivity targets such as steel rollers and other metal
surfaces.

https://www.omega.co.uk/OS-MINI22

Automotive Testing
OMEGA provides a comprehensive range of thermal
cameras, infrared guns and infrared transmitters suitable
for remote temperature measurement and analysis.
The featured OS730K unit has a range of -50 to 800°C,
a Type K thermocouple input, and is ideal for engine
temperature monitoring. Many different styles are
available on our website.

https://www.omega.co.uk/automotive

7
Fixed Mount Infrared Sensors
with Optional Touch Screen Display

OS-MINI Series MINIATURE SENSOR WITH OPTIONAL


TOUCH SCREEN DISPLAY

The OS-MINI has adjustable emissivity setting on all models,


suitable for a wide range of target materials such as paper,
plastics, food, painted surfaces, and many more. Optional
touch screen display available.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.20 to 1.00

Spectral response 8 to 14 µm

Field of view up to 30:1

Output 4 to 20 mA or RS485 Modbus®

es.omega.com/os-mini

OS-MINI22 Series HIGH TEMPERATURE MINIATURE SENSOR


WITH OPTIONAL TOUCH SCREEN DISPLAY

Ideal for extreme temperature environments, the OS-MINI22


has short wavelength measurement for low-emissivity targets
such as steel rollers and other Metal surfaces. Optional touch
screen available.
Range 100 to 2000°C
Accuracy ± 1%
Emissivity 0.20 to 1.00

Spectral response 2.0 to 2.6 µm

Field of view up to 75:1

Output 4 to 20 mA or RS485 Modbus®

es.omega.com/os-mini22

8
Fixed Mount Infrared Sensors
with Optional Touch Screen Display

OS-PC HIGH SPEED INFRARED SENSOR


WITH SMALL MEASURED FIELD OF VIEW SIZE

The OS-PC cube is an infrared pyrometer with an extremely


fast response time and a very small measurement area size.
Designed for extremely fast response times, or where the
object to be measured is very small.
Range 0 to 500°C
Accuracy ± 1%
Emissivity 0.3 to 1.0

Spectral response 82 to 7 µm

Field of view up to 30:1

Output 4 to 20 mA or RS485 Modbus®

www.omega.co.uk/os-pc

OS-MINIHUB MULTI-CHANNEL INFRARED TEMPERATURE


MONITORING SYSTEM RS485/MODBUS

OS-MINIHUB sensors are designed to measure the surface


temperature of non-reflective materials, from -20 to 1000°C.
They are sealed to IP65, built from 316 stainless steel, and
fully tested to industrial EMC standards.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.2 to 1.0

Spectral response 8 to 14 µm

Field of view up to 75:1

Output 4 to 20 mA or RS485 Modbus®

www.omega.co.uk/os-minihub

9
Fixed Mount Infrared Sensors
for Integrated Systems

OS-MINIUSB MINIATURE SENSOR THAT MEASURES THE


SURFACE TEMPERATURE OF A SOLID OR LIQUID

The OS-MINIUSB is a miniature infrared sensor that measures


the surface temperature of a solid or liquid without contact. It can
measure non-metal surfaces between -20 and 1000°C, with a
response time of just 125 ms.
Range -20 to 1000°C
Accuracy ± 1%
Emissivity 0.2 to 1.0

Spectral response 8 to 14 µm

Field of view 2:1 or 20:1

Output USB

www.omega.co.uk/os-miniusb

OS301A-USB COMPACT INFRARED TEMPERATURE


TRANSMITTER

OS301A-USB is specially designed for distant targets and has


an optical resolution of 30:1. It measures temperatures from
-40 to 1000°C accurately and consistently, with an outstanding
response time of 240 mS.
Range - 40 to 1000°C
Accuracy ± 1%
Emissivity 1.0

Spectral response 2.0 to 2.4 µm

Field of view 30:1

Output USB, 4 to 20 mA

www.omega.co.uk/os151-usb

10
Fixed Mount Infrared Sensors
for Integrated Systems

OS150-2USB PC CONFIGURABLE INFRARED


TEMPERATURE SENSOR

PC configurable temperature range, short-wavelength measure-


ment for low emissivity targets such as steel rollers and other
metal surfaces, even at low temperatures.

Range 45 to 2000°C
Accuracy ± 1%
Emissivity 0.1 to 1.0

Spectral response 2.0 to 2.4 µm

Field of view up to 75:1

Output 0 to 20 mA or 4 to 20 mA

www.omega.co.uk/os150-2usb

OS210 LOW-COST INFRA RED TEMPERATURE


SENSOR/TRANSMITTER

This Series is a range of high quality, low cost, compact sensors


which measure the temperature of inaccessible or moving objects
and materials with an outstanding response time of 240 ms

Range -20 to 500°C


Accuracy ± 1%
Emissivity Fixed at 0.95

Spectral response 8 to 14 µm

Field of view up to 30:1

Output 0 to 20 mA or 4 to 20 mA

www.omega.co.uk/OS210-150-300-800

11
Fixed Mount Infrared Sensors
for Integrated Systems

OS136A LOW-COST FIXED INFRARED TEMPERATURE


SENSOR AND TRANSMITTER

This mini transmitter is ideal for applications that require measur-


ing temperature in hard-to-reach, confined or harsh environment
areas. Comes with a shielded cable.

Range -18 to 202°C or 149 to 538°C


Accuracy ± 3%
Emissivity Fixed at 0.95

Spectral response 5 to 14 µm

Field of view 6:1

Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, type K


thermocouple, 10 mV/degree analogue

www.omega.co.uk/os136a

OS137A FIXED INFRARED TEMPERATURE SENSOR


AND TRANSMITTER

3 Temperature Ranges Available: OS137A-1: 0 to 100°C


(32 to 212°F) OS137A-2: -18 to 260°C (0 to 500°F)
OS137A-3: -18 to 538°C (0 to 1000°F)

Range -18 to 538°C


Accuracy ± 1.5%
Emissivity 0.5 to 1.0

Spectral response 8 to 14 µm

Field of view 10:1

Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, type K


thermocouple, 10 mV/degree analogue

www.omega.co.uk/os137a

12
Fixed Mount Infrared Sensors
for Integrated Systems

OS36-2 COMPACT INFRARED SENSOR AND


AIR PURGE HEAD

The OS36-2 internal air purge passages provide a convenient


and highly efficient method of maintaining optical cleanliness in
harsh environments.

Range -18 to 250°C


Accuracy ± 2%
Emissivity 0.8 to 1.0

Spectral response 6.5 to 14 µm

Field of view 2:1

Output J, K, E, or T Thermocouple

www.omega.co.uk/os36-2

OS36 Series INFRARED THERMOCOUPLES

The OS36 produces a thermocouple output signal that can be


used with any standard J, K, T or E thermocouple instrumenta-
tion. The thermocouple’s accuracy is specified for target emissivi-
ty between 0.8 and 1.0.
Range -18 to 250°C
Accuracy ± 2%
Emissivity 0.8 to 1.0

Spectral response 6.5 to 14 µm

Field of view 1:1

Output J, K, E, or T Thermocouple

www.omega.co.uk/OS36

13
OS36 Infrared Sensor Accessories

OS36-APC COOLING JACKET KIT FOR OS36 AND OS36-2


INFRARED THERMOCOUPLES

The OS36-APC needs water flow rate of only 0.05 gpm (190 cc/
min.) to protect an infrared thermocouple at 540°C (1000°F).
This kit makes it possible to use either the OS36 or OS36-2 with
air, water or both for service in harsh environments.
Range 0 to 540°C
Accuracy NA
Emissivity NA

Spectral response NA

Field of view NA

Output NA

www.omega.co.uk/os36-apc

OS36-GMK GOOSE NECK MOUNTING KIT FOR OS36 SERIES


INFRARED THERMOCOUPLES

For fast and convenient mounting of OS36 Series infrared ther-


mocouples. Heavy duty design provides excellent stiffness for
reliable positioning.

Range 0 to 540°C
Accuracy NA
Emissivity NA

Spectral response NA

Field of view NA

Output NA

www.omega.co.uk/os36-gmk

14
Fixed Mount Infrared Sensors
for Integrated Systems

OS36-01 FIXED MOUNT INFRARED THERMOCOUPLES


WITH ABS PLASTIC HOUSING

These units feature an exceptionally strong, hermetically sealed


ABS plastic housing that makes non-contact infrared temperature
measurement more economical.

Range -18 to 250°C


Accuracy ± 2%
Emissivity 0.8 to 1.0

Spectral response 6.5 to 14 µm

Field of view 1:1

Output J, K, E or T Thermocouple
Output Signal

www.omega.co.uk/os36-01

OS36-3-K-1200F RUGGED INFRARED NON-CONTACT


TEMPERATURE SENSOR

The OS36-3-K-1200 is ideal for use in extreme ambient


temperature applications. Maintains accuracy with thermal shock.
High pressure and vacuum compatible.

Range -45 to 650°C


Accuracy ± 1%
Emissivity 0.90

Spectral response 6.5 to 14 µm

Field of view 3:1

Output Type K thermocouple output

www.omega.co.uk/os36-3-k-1200f

15
Fixed Mount Infrared Sensors
for Integrated Systems

OS36-3-RF REFRIGERATED FOODS ENVIRONMENTS


INFRARED TEMPERATURE SENSOR

Idea for use in refrigerated foods environments. Highly reliable


(minimal downtime), hermetically sealed, immersible for wash
downs, and with built-in air purge.

Range -18 to 38°C


Accuracy ± 3.5%
Emissivity 0.90

Spectral response 6.5 to 14 µm

Field of view 3:1

Output 0 to 10 Vdc

www.omega.co.uk/os36-3-rf

OS36-3 RUGGED INFRARED THERMOCOUPLE WITH


INTEGRAL AIR COOL/PURGE HEAD

The OS36-3 Series is ideal for use in paint or ink environments


in which the sensor is mounted remotely from the target. Also
equipped with an internal air cool/purge system

Range -18 to 250°C


Accuracy ± 2%
Emissivity 0.8 to 1.0

Spectral response 6.5 to 14 µm

Field of view 3:1

Output J, K, E or T Thermocouple
Output Signal

www.omega.co.uk/os36-3

16
Fixed Mount Infrared Sensors
for Integrated Systems

OS38 ADJUSTABLE RANGE INFRARED SENSOR WITH


INTEGRAL AIR COOL AND PURGE HEAD

The OS38 units offer a choice of 10:1, 20:1 or 100:1 optics. It


features a built-in air purge collar that conveniently and efficiently
maintains optical cleanliness in harsh environments. Great for
clean metals.
Range 27 to 93°C
Accuracy ± 2%
Emissivity 0.8 to 1.0

Spectral response 0.1 to 5 µm

Field of view 10:1, 20:1 or 100:1

Output J or K Thermocouple Output Signal; R or S


Type for 100:1 Models

www.omega.co.uk/os37_os38

OSAT INTRINSICALLY SAFE INFRARED


TEMPERATURE SENSOR

Suitable for hazardous areas, zone 0, 1 and 2 (gas), and


zone 20, 21 and 22 (dust), with a suitable intrinsically safe
isolator

Range -20 to 500°C


Accuracy ± 1%
Emissivity 0.20 to 1.00

Spectral response 8 to 14 µm

Field of view up to 30:1

Output 4 to 20 mA

www.omega.co.uk/osat

17
Hand-held Infrared Sensors

OS-VIR50 DIGITAL INFRARED VIDEO THERMOMETER


FOR EXTREME TEMPERATURES

Capable of making infrared and contact (thermocouple)


temperature measurements, the built-in camera offers still image
and video capturing functionality for documenting measurement
locations.
Range -50 to 2200°C
Accuracy ± 1% to ± 3%
Emissivity 0.1 to 1 (0.001 increment)

Spectral response 8 to 14 µm

Field of view 50:1

Live video window. Output USB, SD Card Storage

www.omega.co.uk/os-vir50

HHM-EX623 CLAMP METER 400 A DUAL INPUT WITH


INFRARED THERMOMETER AND VOLTAGE

The HHM-EX623 is a True RMS Clamp Meter with built-in dual


thermocouple inputs for T1, T2, and T1-T2 differential temperature
measurement and non-contact infrared thermometer..

Range -50 to 270°C


Accuracy ± 2%
Emissivity 0.95 fixed

Spectral response 6 to 16 µm

Field of view 8:1

Output -

www.omega.co.uk/hhm-ex623

18
Hand-held Infrared Sensors

OS758-LS DUAL LASER INFRARED THERMOMETER

The OS758-LS offers a rugged design that is shatter-proof at


1 metre. A Type K thermocouple input is included for contact
measurements, often used to verify emissivity.

Range -35 to 1600°C


Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)

Spectral response 8 to 14 µm

Field of view 60:1

Output SPI, USB, SD Card Storage

es.omega.com/os758-ls

OS768-LS DUAL NON-CONTACT LASER HIGH


TEMPERATURE INFRARED THERMOMETER

Accurately verify surface temperatures, can also input Type K


thermocouple input (free T/C included) for high precision meas-
urement of contact surfaces, gases, and liquids.

Range 100 to 1800°C


Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)

Spectral response 8 to 14 µm

Field of view 75:1

Output USB

es.omega.com/os768-ls

19
Hand-held Infrared Sensors

OS-PEN9 POCKET SIZE INFRARED THERMOMETER


WITH CIRCLE LASER

These Infrared pens include: 9:1 optical ratio with circular laser,
an ergonomic double injection casing for comfortable holding and
measuring, and a backlit LCD. Just point, press, and read the
display.
Range 33 to 500°C
Accuracy ± 2%
Emissivity 0.95 (fixed)

Spectral response 6 to 14 µm

Field of view 9:1

Output -

www.omega.co.uk/os-pen9

OM-144 TEMPERATURE/HUMIDITY DATA LOGGERS


WITH USB INTERFACE

The OM-144 is a low cost, compact, battery powered temper-


ature and humidity data logger, capable of unattended logging
of the ambient temperature and relative humidity (RH) of an
environment for days, weeks or months.
Range –20 to 250°C
Accuracy ± 3%
Emissivity 0.95 (fixed)

Spectral response -

Field of view 2:1

Output USB, 10,000 Readings

www.omega.co.uk/om-140-series

20
Hand-held Infrared Sensors

OS423HT-LS INTRINSICALLY SAFE INFRARED


TEMPERATURE SENSOR

OS423HT-LS offers laser sighting, several mathemati-


cal modes, and adjustable emissivity. Long battery life,
(typical 180 hours without laser or backlight), is obtained
from 2 “AAA” batteries (included).
Range -60 to 1000°C
Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)

Spectral response 8 to 14 µm

Field of view 30:1

Output -

www.omega.co.uk/os423-ls

OS1327D INFRARED THERMOMETER WITH


USB INTERFACE

The OS1327D features adjustable emissivity, laser sighting,


backlit LCD, 12:1 field of view, max, minimum,average,
differential temperature monitoring, high/low audible alarms,
temperature and data storage.
Range -35 to 500°C
Accuracy ± 2%
Emissivity 0.17 to 1

Spectral response 6 to 14 µm

Field of view 12:1

Output Reading Storage

www.omega.co.uk/os1327d

21
Hand-held Infrared Sensors

OS418-LS NON-CONTACT INFRARED THERMOMETER


WITH RELATIVE HUMIDITY

Accurately verify surface temperatures, can also input Type K


thermocouple input (free T/C included) for high precision meas-
urement of contact surfaces, gases, and liquids.

Range -60 to 500°C


Accuracy ± 2%
Emissivity 0.1 to 1 (0.001 increment)

Spectral response 8 to 14 µm

Field of view 12:1

Output -

www.omega.co.uk/os418-ls

OS543 LOW COST INFRARED THERMOMETER GUN

Low cost infrared thermometers offer solutions for many non-con-


tact temperature measurement applications. Applications include:
Electrical, Asphalt, HVAC, Automotive, In-Process Temperature
Measurement, Fire and Safety.
Range -30 to 550°C
Accuracy ± 2%
Emissivity 0.95 (fixed)

Spectral response 6 to 14 µm

Field of view 10:1

Output -

www.omega.co.uk/os540

22
Handheld Infrared Sensors

OS561 LOW COST INFRARED THERMOMETER GUN

The OS561 is an economical tool for temperature measure-


ments. It features a user-friendly 2-key operation, and max and
hold modes. The backlit LCD screen and the laser stay on when
the trigger is depressed.
Range -60 to 500°C°C
Accuracy ± 2%
Emissivity 0.95 (fixed)

Spectral response 8 to 14 µm

Field of view 10:1

Output -

www.omega.co.uk/os561

OSXL-TG165 INFRARED TEMPERATURE CAMERA

Bridging the gap between single spot infrared thermometers and


infrared temperature cameras, the OSXL-TG165 gives you the
advantage of thermal imaging to help you discover temperature
issues you can’t see with typical spot radiometers.
Range -25 to 380°C
Accuracy ± 1.5%
Emissivity 4 pre-set levels with custom
adjustment, 0.1 to 0.99
Spectral response 8 to 14 µm

Field of view 24:1

www.omega.co.uk/osxl-tg165

23
European Headquarters

United Kingdom

Int: +44 (0) 161 777 6611


Free Phone: 0800 488 488
[email protected]
omega.co.uk

Headquarters
United States

Int: 1-203-359-1660
US & Canada: 1-888-826-6342
[email protected]
omega.com

European Sales & Service

Benelux Germany
Int: (+31) 070 770 3815 Int: (+49) 07056-9398-0
Domestic: 07077 03815 Free Phone: 0800-8266342
[email protected] [email protected]
omega.nl omega.de

Denmark Italy
Int: (+45) 80 25 14 43 Int: (+39) 022 333 1521
Domestic: 80 25 14 43 Free Phone: 800 906 907
[email protected] [email protected]
dk.omega.com it.omega.com

France Spain
Int: (+33) 01 57 32 48 17 Int: (+34) 911 776 121
Free Phone: 0805 541 038 Free Phone: 800 900 532
[email protected] [email protected]
omega.fr es.omega.com

© COPYRIGHT 2017 OMEGA ENGINEERING,LTD. ALL RIGHTS RESERVED