0% found this document useful (0 votes)
14 views5 pages

Electroheat ECO-V Inverter Side Vent Heat Pumps - Jul23 - ZZB2010 - Low-Res Spread

The Electroheat ECO-V inverter pool heat pumps provide an energy-efficient solution for heating swimming pools, allowing for extended swimming seasons and year-round enjoyment. Utilizing inverter technology, these heat pumps can produce up to 8kW of heat for every 1kW of electricity consumed, resulting in significant energy savings and more stable water temperatures. The units also feature automatic de-icing, smart controls, and are designed for outdoor installation, making them a versatile choice for pool heating.

Uploaded by

Mochtar Sulaiman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views5 pages

Electroheat ECO-V Inverter Side Vent Heat Pumps - Jul23 - ZZB2010 - Low-Res Spread

The Electroheat ECO-V inverter pool heat pumps provide an energy-efficient solution for heating swimming pools, allowing for extended swimming seasons and year-round enjoyment. Utilizing inverter technology, these heat pumps can produce up to 8kW of heat for every 1kW of electricity consumed, resulting in significant energy savings and more stable water temperatures. The units also feature automatic de-icing, smart controls, and are designed for outdoor installation, making them a versatile choice for pool heating.

Uploaded by

Mochtar Sulaiman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

ECO-V

ECO-V

Inverter pool heat pumps


extend the season or swim year round

www.waterco.com
COST EFFECTIVE HEATING
A swimming pool is a major financial investment. Getting the most out of your pool, means keeping the

Extend the swimming season pool at a swimmable temperature for the maximum number of hours in each day and the maximum
number of days in each year.

A pool heat pump will economically keep your pool warm 24 hours a day.

Compared to gas and electric heaters, the Electroheat ECO V pool heat pump range use just a fraction
of the energy to generate the same amount of heat and unlike solar heating; there is no reliance on the
The Electroheat heat pump range are an ideal sun as the latent heat in the air is used.
solution for heating:
For every 1kW of electricity consumed, Electroheat can produce up to 8kW of heat.

Swimming pools to
Plunge pools
extend the season
ENERGY EFFICIENT INVERTER TECHNOLOGY

Swimming pools for Swim spas Drive at fixed speed. Can’t adjust accelerator. Pool water has greater
It takes longer time to reach The unit waits until water is below temperature fluctuation.
year round enjoyment and spas desired temperature and switch off. desired temperature to switch on.

Uncomfortable

Comfortable

Uncomfortable Desired temperature

Reaches desired Adjust speed to maintain Pool water kept close to


temperature faster desired temperature desired temperature

Inverter system

Fixed-speed system Output power variation diagrammatic sketch

Electroheat ECO-V inverter pool heat pumps utilise a variable speed compressor to regulate the pool
water temperature automatically and independently.

• inverter technology uses a variable speed compressor motor similar to a cars engine
• it slows down and speeds up as needed to hold a selected desired temperature or speed
• the desired temperature will be reached more quickly and maintained more efficiently
• inverter technology provides a more precise water temperature without the fluctuations and power
wastage of fixed speed systems
• inverter technology is significantly more energy efficient with energy savings of between 15 - 30%
over fixed speed systems
• the speed control of the compressor and fan motor also means quieter operation

AUTOMATIC EVAPORATOR DE-ICING


Electroheat ECO-V inverter pool heat pumps feature automatic de-icing for situations where frost or
ice may develop on the evaporator as part of normal operation. Common in cooler climates or winter
months, when a build-up of ice is detected the heat pump shifts temporarily into cooling mode to
reverse the flow of refrigerant through the evaporator coils. Hot refrigerant moves through the outside
coils, melting ice and defrosting the system. When the defrost cycle is complete, the unit shifts back to
* Heating pools in winter months May – August should be achieved using maximum day time operation of eight hours.
heating mode.
A pool cover is necessary to achieve desired temperature in winter.

2 | Electroheat ECO-V inverter pool heat pumps www.waterco.com Electroheat ECO-V inverter pool heat pumps | 3
Frequently asked questions

ECO-V SHOULD I USE A POOL COVER? WHAT IS THE ELECTROHEAT’S HEATER


The most effective way to prevent heat loss is to RUNNING TIME?
install a pool cover. An un-blanketed pool loses 2-3 Most units should be sized to operate during warmer
SMART CONTROLS for temperature management times more heat than a blanketed pool. Pool covers months the pool filtering cycle time of 8 - 12 hours
and self diagnosis virtually eliminate evaporation and reduce heat loss daily (Winter - 8hrs, Summer - up to 12hrs), providing
ECO-V by insulating the surface of the pool, greatly reducing a steady flow of heated water. On warmer days the
pool heating costs. As with all pool heaters, it would be heater will run less because the heat loss will be less.
advisable to use a pool cover at night, and when the
INBUILT SAFETY DEVICES for water flow, refrigerant pool is not in use. Electroheat heat pumps have a lower heating capacity
level and compressor startup delay on a BTU/hr basis compared to fossil fuel based pool
WHAT IS THE MINIMUM AMBIENT OPERATING heaters such as gas heaters. Therefore, Electroheat
TEMPERATURE? heat pumps require longer operation to accomplish the
The heat pump will actually operate down to an ambient desired temperature.
POWERFUL HEAT TRANSFER through the coiled air temperature of 0° if fitted with hot gas deicing but
heat exchanger, maximising water contact with minimal heat output. Therefore, we recommend If your heat pump has been sized and installed
heat pumps be operated in the warmest part of a 24 correctly between 10°C to 18°C, it will increase your
hour period to increase operating efficiency. water temperature by 3°C to 5.5°C a day. Over 21°C you
should obtain an increase up to 0.8°C a hour and over
TITANIUM DUAL COIL heat exchanger is highly 26°C up to 1.1°C an hour depending on the size of the
WHAT IS THE BEST LOCATION FOR
resistant to ozone, iodine, baquacil, salt and pool, the size of the heat pump, the water temperature,
chlorinated water THE ELECTROHEAT?
and the ambient air temperature at the moment of
The location of the Electroheat is very important in
operation.
keeping installation costs to a minimum, while providing
for maximum efficiency of operation allowing adequate
LARGE BLUE FIN EVAPORATOR AREA to extract more ambient Even though the Electroheat may require longer
heat. Blue Fin coating provides additional protection against
service and maintenance access.
operation, it will still heat the pool far more
corrosion, especially for coastal installations.
economically.
The unit should be located as close as practically
possible to the existing pool pump and filter to
HOW DOES ELECTROHEAT COMPARE WITH
minimise water piping. The use of 90 degree bends and
SOLAR HEATING AND GAS HEATING?
SCROLL COMPRESSOR for improved efficiency short radius elbows in the water piping should be kept
and high performance to a minimum. Longer distances from the pool increase Solar
piping heat loss. • Fuelled by the power of the sun, solar heating systems
are a low-cost method of heating up your pool water.
CAN THE ELECTROHEAT BE ENCLOSED?
• As solar heating is reliant on the sun, they are best
WEATHERPROOF CABINET for The Electroheat is designed for outdoor installation and used to extend the swimming season.
outdoor installation
should not be installed in totally enclosed areas such
as a shed, garage, etc., unless mechanical ventilation is • Virtually no operating costs, just the cost of electricity
provided to ensure adequate air exchange for proper to pump pool water through the solar absorber on
operation. Re-circulation of cold discharged air back the roof.
R32 REFRIGERANT, ozone friendly and into the evaporator coil will greatly reduce unit’s
Gas heaters
R32 maximises performance heating capacity and efficiency.
• Gas heaters are the fastest method for heating
WHAT IS THE ELECTROHEAT’S PERFORMANCE your pool, providing a comfortable temperature for
DEPENDENT ON? swimming on demand. Gas is best for heating pools
AUTOMATIC HOT GAS DE-ICING or spas for short periods of time.
Heats your pool even when the ambient air Performance will fluctuate depending on water and
temperature is close to 0° weather temperatures. 5 important factors determine • Gas heaters can easily maintain any desired
the performance of Electroheat: temperature regardless of the weather.
Warranty - Residential 1. Size of the pool • Gas heaters are effective, but expensive to operate.
25 years - titanium heat exchanger tube against corrosion (eff 1 Aug 22) 2. The desired temperature of the pool
3 years - compressor
2 years - all other components 3. Ambient air temperature - the warmer the air, the Heat pumps
Warranty- Labour - 1 year better the performance • Heat pumps may not heat up the swimming pool as
Warranty- Commercial - 1 year 4. The presence of a pool cover fast as gas heaters, but are more energy efficient.
Conditions apply, see the Waterco Limited warranty set out in
5. The size of the heater • Heat pumps require a small amount of electricity; its
the Waterco Warranty Booklet or view it at www.waterco.com
heat energy source is extracted from the ambient air.

4 | Electroheat ECO-V inverter pool heat pumps www.waterco.com Electroheat ECO-V inverter pool heat pumps | 5
Performance Specifications - Electroheat ECO-V Inverter Side Vent
Model 12kW 15kW 20kW 27kW
Heating Capacity KW 11.9 ~ 3.8 14.5 ~ 4.2 20.2 ~ 5.3 27.0 ~ 14.3
Air 27C Electrical Input KW 1.4 ~ 0.25 2.4 ~ 0.48 3.0 ~ 0.5 5.1 ~ 1.75
Clearance
/ Water
26C COP 8.48 ~ 15.2 5.99 ~ 8.75 6.64 ~ 10.6 5.3 ~ 8.2
Clearance to rear
Normal Current Amps 6.1 ~ 1.1 10.4 ~ 2.1 13.0 ~ 2.2 24.2 ~ 3.95
minimum 30cm
Heating Capacity KW 9.2 ~ 2.5 12.2 ~ 3.5 17.0 ~ 4.5 24.1 ~ 6.1
Air 15C Electrical Input KW 1.86 ~ 0.32 2.36 ~ 0.46 3.62 ~ 0.61 5.25 ~ 0.85 Clearance to rear
/ Water min 30cm
26C COP 4.95 ~ 7.8 4.85 ~ 7.6 4.7 ~ 7.4 4.6 ~ 7.2
Normal Current Amps 8.08 ~ 1.4 9.85 ~ 2.0 15.7 ~ 2.65 24.2 ~ 3.95
Power Supply V / Hz 230-240VAC / 50Hz
Supply Voltage Phase Single Phase
Breaker or fuse size Amps 20 20 20 32
Electrical Connection 10A Plug 15A Plug Terminals
Set Temperature range °C 15°C ~ 40°C Clearance
Operating Temp range °C -10°C ~ 43°C to side Clearance
Clearance
min 60cm to side
Water Heat Exchanger Titanium Coil / PVC Tank min 60cm
to side
Heat Exchanger Max. Pressure 3.5 bar / 350kPa min 60cm

Compressor Inverter
Compressor Quantity 1
Fan Quanity 1 2
Exhaust Direction Horizontal
Water Inlet / Outlet Dimension 1.5"
Hydraulic Connection mm PVC 40 SLIP No obstruction to No obstruction within 2.5m
Nominal Water flow LPM 84 - 94 100 - 110 110 - 120 165 - 195 front 2.5m minimum minimum to allow cold air
dispersal
Sound Pressure at 1M dB(A) 50 ~ 59 50 ~ 58
Sound Pressure at 10M dB(A) 32 ~ 42 32 ~ 40
Unit Dimensions (W*L*H) mm 1269 * 370 * 714 1092 * 402 * 1276
Evaporator Area m2 1.16 1.16 1.71 2.29
Powder Coat
Cabinet Material Polymer Dimensions
Steel
Net Weight kg 53 59 67 126
Refrigerant R32 R32
Display LED LCD
Modes Heating / Cooling

Related products:
H
Electroheat MKV range - Pool heat pumps
H
Electroheat Pro range - Pool heat pumps for commercial applications.
Electroheat ECO-V range - Top venting pool heat pumps with inverter technology

Sizing Chart to Heat your Pool to 28°C Sept to April


Temperate Location * Warm Location **
Up to 10 hrs / Day Run time Up to 10 hrs / Day Run time
Pool Size (m) Litres with Pool Cover No Pool Cover with Pool Cover No Pool Cover
3x6 Up to 23000 12kW 20kW 12kW 15kW
L
3x7 Up to 27000 15kW 20kW 12kW 15kW W
4x7 Up to 35000 15kW 20kW 12Kw 20kW
L
4.5 x 8.5 Up to 50000 20kW 27kW 15kW 27kW W

5 x 10 Up to 65000 27kW 20kW x 2 15kW 27kW


5.5 x 11 Up to 80000 27kW 27kW x 2 20kW 27kW
Note: Size and performance are influenced by ambient temperature, humidity, use of a pool cover, night time temperature, pool location, wind factor,
water features and if the unit is switched off over night. The recommended sizing in the table above is based on operating the unit up to 10 daytime
hours with the pool subjected to normal suburban wind. No allowance has been made for the cooling effects of water features, negative edges or
high wind areas. Therefore, any under sizing of the heater for your pool heating requirements is not the responsibility of Waterco.
* Temperate Location (Sydney) :- Where minimum average daytime temperatures between September to April are not less than 18°C.
** Warm Location (Brisbane) :- Where minimum average daytime temperatures between September to April are not less than 24°C
***Pool heating between May and August (winter) will require a larger heat pump. Consult www.watercocalculator.com or contact your local
Waterco office.

6 | Electroheat ECO-V inverter pool heat pumps www.waterco.com Electroheat ECO-V inverter pool heat pumps | 7
Waterco pioneers reliable solutions for healthy, safe water environments, which are
used in residential, commercial and industrial applications in over 40 countries.

Established in 1981, it has since become a global brand recognised for designing and
manufacturing filtration and sanitisation innovations for the swimming pool, spa,
aquaculture, and water purification sectors.

OFFICES - AUSTRALIA OFFICES - OVERSEAS


NSW - Sydney (Head Office) Waterco (Europe) Limited Waterco (Far East) Sdn Bhd
Tel: +61 2 9898 8600 Sittingbourne, Kent. UK Selangor, Malaysia
QLD - Brisbane Tel: +44 (0) 1795 521 733 Tel: +60 3 6145 6000 distributed by:
ZZB1937 07/2023

Tel: +61 7 3299 9900 Waterco (USA) Inc PT Waterco Indonesia


VIC/TAS - Melbourne Augusta, Georgia, USA Jakarta, Indonesia
Tel: +61 3 9764 1211 Tel: +1 706 793 7291 Tel: +62 21 4585 1481
WA - Perth Waterco Canada Waterco Singapore Intl Pte Ltd
Tel: +61 8 9273 1900 Boucherville, Quebec, Canada MAPEX Building, Singapore
Tel: +1 450 748 1421 Tel: +65 6344 2378
SA/NT - Adelaide
Tel: +61 8 8244 6000 Waterco (NZ) Limited Waterco Vietnam Company
Auckland, New Zealand Limited
ACT Distribution Tel: +64 9 525 7570 Ho Chi Minh City, Vietnam.
Tel: +61 2 6280 6476 Tel: +84 28 3622 7780
Waterco (C) Limited
Guangzhou, China
AUSTRALIAN MEMBER
Tel: +86 20 3222 2180

In the interest of providing better quality and value we are constantly improving and updating our products. Consequently, pictures and information on our brochures may sometimes vary slightly
from models available.

You might also like