The MPM489 Pressure Transmitter is designed for various industrial applications, offering a wide measurement range from -100kPa to 100MPa with multiple configurations for different pressure types. It features robust construction for harsh environments, intrinsic safety, and explosion-proof certifications, making it suitable for hazardous areas. The device ensures high accuracy and long-term stability, with various options for electrical connections and thread ports.

Uploaded by

Israel Leyrana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views11 pages

MPM489 Pressure Transmitter

The MPM489 Pressure Transmitter is designed for various industrial applications, offering a wide measurement range from -100kPa to 100MPa with multiple configurations for different pressure types. It features robust construction for harsh environments, intrinsic safety, and explosion-proof certifications, making it suitable for hazardous areas. The device ensures high accuracy and long-term stability, with various options for electrical connections and thread ports.

Uploaded by

Israel Leyrana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Flexible & Customizable

Pressure Transmitter
MPM489

Applications
Specifications
• Hydrology and water resources
• Petrochemical Range -100kPa…0kPa - 10kPa…100MPa
• Electric power
Overpressure ≤ 2 times FS or 110MPa (min. Value is valid)
• Machinery manufacturing
Gauge G, Absolute A, Sealed Gauge S, Positive/
• Hydraulic and pneumatic control Pressure type
Negative N

Accuracy Refer to “Measuring Range & Accuracy Table”


Features
Long-term stability ±0.3%FS/year
• Intrinsically safe, Ex ia IIC T6 Ga
-30℃~ 80℃(B1, B4)
• Flameproof, Ex db IIC T6 Gb
• ATEX, II 1 G Ex ia IIC T4 Ga -20℃~ 70℃(B2, cable material: PE)

• CE, EAC, RoHS and CCS approved -20℃~ 80℃(B2, cable material: PUR)
Operating
temperature -30℃~ 60℃(Intrinsically safe explosion-proof,
Introduction B1)
-20℃~ 60℃(Intrinsically safe explosion-proof,
M P M 4 8 9 P r e s s u r e Tr a n s m i t t e r i s B2)

developed for general industry. The transmitter -20℃~ 60℃(Flameproof)

incorporates a highly stable piezoresistive sensor, -40℃~ 120℃(B1)


Storage
specialized circuitry, and a high-strength stainless temperature
-20℃~ 85℃(B2, B4)
steel housing, featuring an integrated construction
with standardized output. It offers multiple Vibration 10g,55Hz ~ 2000Hz

thread ports and electrical connection options, Shock 100g,11ms


meeting the precise measurement requirements
IP rating IP65
of automation control systems. The transmitter
is rugged and durable, suitable for operation in Weight ≤270g

harsh environments. It is available with intrinsically


safe and explosion-proof configurations, making it
suitable for use in hazardous areas.

www.microsensorcorp.com V6.0 02/2025


02 MPM489 Pressure Transmitter
Measuring Range & Accuracy Table
Gauge Pressure G
Unit Measuring Range Accuracy Overpressure Code Unit Measuring Range Accuracy Overpressure Code
0-7 15 K007 0 - 70 150 m070
0 - 10 ±1%FS 20 K010 0 - 100 ±1%FS 200 m100
0 - 20 40 K020 0 - 200 500 m200
0 - 25 50 K025 0 - 250 500 m250
0 - 40 100 K040 0 - 400 1000 m400
0 - 50 100 K050 mbar
0 - 500 1000 m500
0 - 60 100 K060 0 - 600 ±0.5%FS 1200 m600
±0.5%FS
0 - 70 100 K070 0 - 700 1400 m700
0 - 80 200 K080 0 - 800 1600 m800
0 - 90 200 K090 0 - 900 1800 m900
0 - 100 200 K100
kPa
0 - 160 300 K160 0-1 ±0.5%FS 2 B001
0 - 200 400 K200 0 - 1.6 3 B1D6
0 - 250 500 K250 0-2 4 B002
0 - 300 600 K300 0 - 2.5 5 B2D5
0 - 400 1000 K400 0-3 6 B003
±0.25%FS
0 - 500 1000 K500 0-4 10 B004
0-5 10 B005
0 - 600 1000 K600
0-6 10 B006
0 - 700 1400 K700
bar 0-7 14 B007
0 - 800 1600 K800
±0.25%FS
0-8 16 B008
0 - 900 1800 K900
0-9 18 B009
0 - 10 20 B010
0-1 2 M1D0
0 - 16 30 B016
0 - 1.6 3 M1D6
0 - 20 40 B020
0-2 4 M2D0
MPa ±0.25%FS 0 - 25 50 B025
0 - 2.5 5 M2D5
0 - 30 60 B030
0-3 6 M3D0
0 - 35 60 B035
0 - 3.5 6 M3D5

0 - 1.5 3 P1D5
±1%FS
0-3 6 P003
0-5 10 P005
0 - 10 ±0.5%FS 15 P010
0 - 15 20 P015
0 - 30 45 P030
psi
0 - 60 150 P060
0 - 100 150 P100
0 - 160 ±0.25%FS 300 P160
0 - 200 300 P200
0 - 300 450 P300
0 - 500 750 P500

www.microsensorcorp.com V6.0 02/2025


MPM489 Pressure Transmitter 03

Sealed Gauge Pressure S


Unit Measuring Range Accuracy Overpressure Code Unit Measuring Range Accuracy Overpressure Code
0 - 3.5 7 M3D5 0 - 35 70 B035
0-4 10 M4D0 0 - 40 100 B040
0-5 10 M5D0 0 - 50 100 B050
0-6 10 M6D0 0 - 60 100 B060
0-7 10 M7D0 0 - 70 100 B070
0-8 15 M8D0 0 - 80 150 B080
0-9 15 M9D0 0 - 90 150 B090
0 - 10 15 M010 0 - 100 150 B100
0 - 16 30 M016 0 - 160 300 B160
0 - 20 30 M020 0 - 200 300 B200
MPa ±0.25%FS bar ±0.25%FS
0 - 25 37.5 M025 0 - 250 450 B250
0 - 30 45 M030 0 - 300 525 B300
0 - 35 52.5 M035 0 - 350 375 B350
0 - 40 60 M040 0 - 400 600 B400
0 - 50 75 M050 0 - 500 750 B500
0 - 60 90 M060 0 - 600 900 B600
0 - 70 100 M070 0 - 700 1000 B700
0 - 80 100 M080 0 - 800 1000 B800
0 - 90 100 M090 0 - 900 1000 B900
0 - 100 110 M100 0 - 1000 1100 B01K

0 - 500 750 P500


0 - 600 1500 P600
0 - 700 1500 P700
0 - 800 1500 P800
0 - 900 1500 P900
0 - 1000 1500 P01K
0 - 2000 3000 P02K
psi 0 - 3000 ±0.25%FS 4500 P03K
0 - 4000 6000 P04K
0 - 5000 7500 P05K
0 - 6000 9000 P06K
0 - 7000 10500 P07K
0 - 8000 12000 P08K
0 - 9000 13500 P09K
0 - 10000 15000 P10K

www.microsensorcorp.com V6.0 02/2025


04 MPM489 Pressure Transmitter

Absolute Pressure A
Unit Measuring Range Accuracy Overpressure Code Unit Measuring Range Accuracy Overpressure Code
0 - 40 100 K040 0-1 2 B001
0-1.6 3 B1D6
0 - 50 100 K050 0-2 4 B002
0 - 60 100 K060 0-2.5 5 B2D5
0 - 70 ±1%FS 100 K070 0-3 6 B003
0-4 10 B004
0 - 80 200 K080 ±0.5%FS
0-5 10 B005
0 - 90 200 K090 0-6 10 B006
0-7 14 B007
0 - 100 200 K100
0-8 16 B008
0 - 160 300 K160 0-9 18 B009
kPa 0 - 200 400 K200 0-10 20 B010
0 - 250 500 K250 0-16 30 B016
0-20 40 B020
0 - 300 600 K300
0-25 50 B025
0 - 400 1000 K400 0-30 60 B030
±0.5%FS 0-35 60 B035
0 - 500 1000 K500
bar 0-40 100 B040
0 - 600 1000 K600 0-50 100 B050
0 - 700 1400 K700 0-60 100 B060
0-70 140 B070
0 - 800 1600 K800
0-80 160 B080
0 - 900 1800 K900 0-90 180 B090
0-100 200 B100
±0.25%FS
0-160 300 B160
0-1 ±0.5%FS 2 M1D0 0-200 300 B200
0 - 1.6 3 M1D6 0-250 375 B250
0-300 350 B300
0-2 4 M2D0 0-350 525 B350
0 - 2.5 5 M2D5 0-400 600 B400
0-500 750 B500
0-3 6 M3D0 0-600 900 B600
0 - 3.5 6 M3D5 0-700 1000 B700
0-800 1000 B800
0-4 6 M4D0
0-900 1000 B900
0-5 10 M5D0 0-1000 1100 B01K
0-6 10 M6D0
0-7 14 M7D0 0-5 10 P005

0-8 16 M8D0 0 - 10 ±1%FS 15 P010

0-9 18 M9D0 0 - 15 20 P015

MPa 0 - 10 20 M010 0 - 30 45 P030


±0.25%FS 0 - 60 150 P060
0 - 16 30 M016 ±0.5%FS
0 - 20 30 M020 0 - 100 150 P100

0 - 25 37.5 M025 0 - 160 300 P160

0 - 30 45 M030 0 - 200 300 P200

0 - 35 52.5 M035 0 - 300 450 P300

0 - 40 60 M040 0 - 400 750 P400

0 - 50 75 M050 0 - 500 750 P500

0 - 60 90 M060 0 - 600 1500 P600


psi 0 - 700 1500 P700
0 - 70 100 M070
0 - 800 1500 P800
0 - 80 100 M080
0 - 900 1500 P900
0 - 90 100 M090
0 - 1000 1500 P01K
0 - 100 110 M100 ±0.25%FS
0 - 2000 3000 P02K
0 - 3000 4500 P03K
0 - 400 1000 m400 0 - 4000 6000 P04K
0 - 500 1000 m500 0 - 5000 7500 P05K
0 - 600 1200 m600 0 - 6000 9000 P06K
mbar ±1%FS
0 - 700 1400 m700 0 - 7000 10500 P07K
0 - 800 1600 m800 0 - 8000 12000 P08K
0 - 900 1800 m900 0 - 9000 13500 P09K
0 - 10000 15000 P10K

www.microsensorcorp.com V6.0 02/2025


MPM489 Pressure Transmitter 05

Positive/Negative Pressure N
Unit Measuring Range Accuracy Overpressure Code Unit Measuring Range Accuracy Overpressure Code
- 25 - 0 50 V025 - 0.25 - 0 0.5 VD25
- 40 - 0 100 V040 - 0.4 - 0 1 V0D4
- 60 - 0 100 V060 - 0.6 - 0 1 V0D6
- 100 - 0 150 V100 -1-0 1.5 V1D0
- 3 - +3 10 C033 - 0.03 - +0.03 0.1 C0D3
- 5 - +20 30 C520 - 0.05 - +0.2 0.3 C052
- 5 - +25 30 C525 - 0.05 - +0.25 0.3 C5D5
- 15 - +15 ±1%FS 30 C015 - 0.15 - +0.15 ±1%FS 0.3 CD15
- 20 - +20 30 C020 - 0.2 - +0.2 0.3 C0D2
- 25 - +25 50 C025 - 0.25 - +0.25 0.5 CD25
- 30 - +30 50 C030 - 0.3 - +0.3 0.5 C003
- 50 - +50 100 C050 - 0.5 - +0.5 1 C005
- 100 - +60 150 C16B - 1 - +0.6 1.5 C0D6
kPa - 100 - +100 300 C11B bar - 1 - +1 2 C101
- 100 - +150 300 C1B5 - 1 - +1.5 3 C1D5
- 100 - +300 500 C13B - 1 - +3 5 C103
- 100 - +500 1000 C15B - 1 - +5 10 C105
- 100 - +900 2000 C19B - 1 - +9 20 C109
- 100 - +1000 2500 C11K - 1 - +10 25 C110
- 100 - +1500 3000 C1K5 - 1 - +15 30 C115
- 100 - +1600 ±0.5%FS 3000 C1K6 - 1 - +16 ±0.5%FS 30 C116
- 100 - +2000 3000 C12K - 1 - +20 30 C120
- 100 - +2400 5000 C24K - 1 - +24 50 C124
- 100 - +2500 5000 C25K - 1 - +25 50 C125
- 100 - +3000 6000 C30K - 1 - +30 60 C130
- 100 - +3500 7000 C35K - 1 - +35 70 C135

-15 - 0 20 PF00
-15 - +10 ±1%FS 20 PF10
-15- +15 45 PF15
-15- +30 150 PF30
psi
-15 - +50 150 PF50
-15 - +80 ±0.5%FS 300 PF80
-15- +100 300 PF1B
-15 - +150 450 P1B5

Test standard:GB/T 17614.1-2015/IEC60770-1:2010


Ambient temperature:20℃ ±5℃
Relative humidity:45% ~ 75%

For other measurement ranges, please contact MICROSENSOR

www.microsensorcorp.com V6.0 02/2025


06 MPM489 Pressure Transmitter
Thermal Error

±0.05%FS/℃ (≤ 100kPa)
Zero thermal error
±0.03%FS/℃ ( > 100kPa)

±0.05%FS/℃ (≤ 100kPa)
Span thermal error
±0.03%FS/℃ ( > 100kPa)

Output Signals

Output Signal Supply Voltage Output Type Load Resistance

4mA~20mA DC 2-wire ≤(U-11)/0.02 (Ω)

1V~5V DC
11V~28V DC
0V~5V DC

0.5V~4.5V DC

0V~10V DC 15V~28V DC 3-wire ≥10kΩ

0.5V~4.5V DC
5V±0.1V DC
0.5V~2.5V DC

0.5V~2.5V DC 3.3V±0.1V DC

Outline Construction
Unit: mm

Flameproof (d) 4-pin connector (B1) Cable (B2) M12×1 4-pin connector (B4)

www.microsensorcorp.com V6.0 02/2025


MPM489 Pressure Transmitter 07

Electrical Connection

4-pin connector Cable M12×1 4-pin connector


(B1) (B2) (B4)

Definition

Current Voltage Current Voltage Current Voltage


2-wire 3-wire 2-wire 3-wire 2-wire 3-wire

+V 1 1 Red Red 1 1

OUT 2 3 Black White 3 3

GND Null 2 Null Black Null 2

Sensor Sealing Construction Materials

O-ring Wetted parts


Welding
(FKM / EPDM ) Isolated diaphragm SS 316L/Tantalum/Titanium alloy
Pressure port: SS 304/SS 316L/Hastelloy C/Titanium
Laser
alloy
welding
O-ring
Laser
Non-wetted parts
welding Housing: SS 304/ SS 316L/Titanium alloy
Cable: PE/PUR

www.microsensorcorp.com V6.0 02/2025


08 MPM489 Pressure Transmitter
Unit: mm
Process Connection
M20× 1.5 Male, face seal (C1) NPT1/ 4 Female (C8)

NPT1/2 Male (C10)


G1/ 4 Male, face seal (C2)

G3/ 8 Male, face seal (C16)

G1/ 2 Male, face seal (C3)

7/16- 20 UNF Male, 90° cone seal (C26)

G1/ 4 Female, waterline seal (C4)

M20×1.5 or G1/2 flush diaphragm (PC1/PC3)

M20×1.5 Male, Waterline (C5)

DN25 Clamp (PD1)

NPT1/4 Male (C6)

DN25 Clamp connection with heat sink (PD1s)

www.microsensorcorp.com V6.0 02/2025


MPM489 Pressure Transmitter 09
Order Guide
MPM489 Pressure Transmitter
Code Pressure type
G
Gauge/Sealed gauge pressure
S
A Absolute pressure
N Negative pressure
Range Measuring range -100kPa…0kPa - 10kPa…100MPa
XXXX Range-specific code
Code Output signal
E 4mA~20mA DC
F 1V~5V DC
J 0V~5V DC
V 0V~10V DC
K 0.5V~4.5V DC
W 0.5V~2.5V DC
Code Power supply
V5 11V~28V DC
V6 5V±0.1V DC
V7 3.3V±0.1V DC
V13 15V~28V DC
Code Accuracy
A1 ±0.25%FS
A2 ±0.5%FS
A3 ±1%FS
Construction material
Code
Isolated diaphragm Pressure port Housing
22 SS 316L SS 304 SS 304
23 SS 316L SS 316L SS 304
24 SS 316L SS 316L SS 316L
25 Tantalum Ta1 SS 316L SS 304
35 Tantalum Ta1 Hastelloy C-276 SS 304
40 Titanium TA1 Titanium TC4 Titanium TC4
Code Sensor sealing
00 FKM (standard)
01 EPDM (optional for special media based on compatibility)
02 Welding (optional for special media based on compatibility)
03 Integral sintering (optional only for PC1, PC3, PD1, and PD1s)
Code Process connection
C1 M20× 1.5 Male, face seal
C2 G1/4 Male, face seal
C3 G1/2 Male, face seal
C4 G1/4 Female
C5 M20×1.5 Male, waterline seal
C6 NPT1/4 Male
C8 NPT1/ 4 Female
C10 NPT1/2 Male
C16 G3/8 Male, face seal
C26 7/16-20 UNF Male, 90° cone seal

0kPa ~ 20kPa…35MPa
PC1 Flush diaphragm M20× 1.5 Male
PC3 Flush diaphragm G1/ 2 Male

0kPa ~ 35kPa…
PD1 Hygienic DN25 clamp connection
Hygienic DN25 clamp connection
PD1s 3.5MPa
with heat sink

MPM489 G M1D6 E V5 A1 22 00 C1 The complete spec.

www.microsensorcorp.com V6.0 02/2025


10 MPM489 Pressure Transmitter
Code Process connection sealing
N None (not optional for C6, C8, C10, PD1, PD1s)
1 NBR
2 FKM (standard, except for C5, C6, C8, C10, PD1, PD1s)
3 EPDM
4 Copper (C5 required)
Code Electrical connection ①
B1 4-pin connector
B11 4-pin connector with 1.5 m PVC cable
B2 Cable
B21 Cable connection with M20×1.5 fixed thread
B22 Cable connection with NPT1/ 2 fixed thread Flameproof only, select one
B23 Cable connection with G1/ 2 fixed thread
B4 M12×1 4-pin connector
B41 M12× 1 4-pin connector with 2m PVC straight cable
B42 M12×1 4-pin connector with 2m PVC angled cable
Code Cable material (optional only for B2 cable)
N None (non-cable connection option)
P1 PE (Standard)
P2 PUR
Code Cable length (Unit: m) (optional only for B2 cable)
N None (non-cable connection option)
L001 1
L1D5 1.5
L002 2
L003 3
L004 4
L005 5
L006 6
L007 7
L008 8
L009 9
L010 10
Code Certification requirement ②
N None
i Intrinsically safe Ex ia IIC T6 Ga
T Ship-use Ex ia IIC T6 Ga、Ex d IIC T6 Gb
y ATEX Ex ia IIC T4 Ga
d Flameproof Ex db IIC T6 Gb
Code Accessory
N No accessory
4-digit LED indicator (only for 4mA~20mA DC output non-explosion proof or
M6
non-ship-use products with B1 electrical connection)
4-digit LCD indicator (only for 4mA~20mA DC output non-explosion proof or
M7
non-ship-use products with B1 electrical connection)
Yb3 Yb junction box (3-core terminals)
Yc3 MS200 (3-core terminals) Polymer plug (default)
Yd PD140
YeM6 Ye(M6)
YeM7 Ye(M7)
Ye Ye (Without indicator)
MS01 Polymer plug (except for Yb3, Yc3, Yd)
D01 Damping gasket

1 B2 P1 L001 y M6 The complete spec.

www.microsensorcorp.com V6.0 02/2025


MPM489 Pressure Transmitter 11
Notes
1、" ② ", refers to certification requirements.
For the intrinsically safety type, current output is available only.
The product can be intrinsically safe explosion-proof/flameproof and suitable for ship-use simultaneously.
2、Refer to the "Measuring Range" on page 2 for product accuracy.
3、The minimum operating temperature of FKM O-ring is -20°C, while EPDM O-ring is -40°C.
4、Please note that for 5V DC/3.3V DC powered products, the cable length must be less than 10m if connected.
5、The 4mA ~ 20mA transmitter can use the M6 or M7 indicator, with a power supply ≥ 16V DC.
6、The ambient temperature of transmitter should be -20°C~ 70°C with M6 indicator, while -10°C~ 60°C
with M7 indicator. Indicator settings refer to its order guide, which can be obtained from the
MICROSENSOR website.
7、If a metrology verification certificate is required, or there are any other special requirements, please
consult with the MICROSENSOR and specify them in the order.

www.microsensorcorp.com V6.0 02/2025