0% found this document useful (0 votes)
85 views1 page

Bob Ns Raceway Layout 08 08

The document outlines specifications for raceway installations, including separation of conduits for data, voice, raw power, and UPS power, with all dimensions provided in millimeters. It emphasizes maintaining a 4-inch gap between power and data runs in the same trench and mandates that only written dimensions be followed. Additionally, it details the nomenclature for raceways and the requirement for verification of dimensions on-site before work begins.

Uploaded by

Vignesh Waran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views1 page

Bob Ns Raceway Layout 08 08

The document outlines specifications for raceway installations, including separation of conduits for data, voice, raw power, and UPS power, with all dimensions provided in millimeters. It emphasizes maintaining a 4-inch gap between power and data runs in the same trench and mandates that only written dimensions be followed. Additionally, it details the nomenclature for raceways and the requirement for verification of dimensions on-site before work begins.

Uploaded by

Vignesh Waran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

RACEWAY NOTE : NOTES

1. IN PARTITIONS SEPARATE CONDUIT FOR DATA/VOICE, RAW POWER & UPS POWER. 1. ALL LEVELS INDICATED ARE IN MM.
AND PROVISION OF CUTOUT SLEEVES AS REQUIRED TO
BE PROVIDED.
2. AT LEAST 4" GAP TO BE MAINTAINED WHERE POWER & DATA RUN 2. DIMENSIONS- LEVELS INDICATED ARE STRUCTURAL UNLESS
STATED OTHERWISE.
THROUGH THE SAME TRENCH. 3. ONLY WRITTEN DIMENSIONS TO BE FOLLOWED & DRAWING
NOT TO BE SCALED.

3. THE RACEWAY NOMENCLATURE TO BE READ AS FOLLOWS. THE FIRST NUMERIC STANDS 4. DIMENSIONS- LEVELS AS SHOWN TO BE VERIFIED AT SITE
BEFORE COMMENCEMENT OF WORK. ANY DESCREPENCIES
IF NOTED SHOULD BE BROUGHT TO THE NOTICE OF
FOR NUMBER OF RACEWAY WHICH IS FOLLOWED FOLLOWED BY TYPE OF RACEWAY

10
CONSULTANTS BEFORE START OF WORK.
400 mm Deep Full Height Storage Electrical DB Location 5. RELEVEÛT SERVICES DRAWING TO BE READ SIMULTANEOUSLY
FOR , THE SECOND NUMERIC AFTER COMMA STANDS FOR NUMBER OF RACEWAYS Cashier-01 ALL DIMENSIONS MENTIONED ARE IN MM.

1500 X 1200 mm
FOLLOWED BY TYPE OF RACEWAYS FOR POWER.
Passage 1.05 M Wide
4. ONE RISER OF 25 MM TO EACH WORKSTATION FOR DATA.

0,2B
FOR EXAMPLE: 2A,1B STANDS FOR - TWO NUMBERS OF A TYPE RACEWAYS

0,1A
0,1A

0,1A
6. ALL MATERIALS - FINISHES ETC. TO BE AS SPECIFIED AND

0,1A
APPROVED BY CONSULTANTS.

FOR DATA & ONE NUMBER OF B TYPE RACEWAY FOR POWER.


5. THE JN BOXES ON FLOOR SHALL BE LOCATED AFTER THE MARKING OF FURNITURE ON

8
FLOOR.

10
8

8
6. RELATED WIRING CONNECTIONS DRAWINGS FOLLOWS. General Segment-01 General Segment-02 General Segment-03 General Segment-04 May I Help You

8
1200 X 600 mm 1200 X 600 mm
7. DATA & VOICE POINT IN AHU,ELETRICAL,STORE,BREAKOUT AREA PANTRY , KITCHEN AREA

1B,0

1B,0
1B,0
09N

15N

18N
TO BE WIRED THROUGH CEILING LAID CONDUIT & DROPPED DOWN THROUGH WALL

2D,0
03N
Cashier-02

0,1B
1500 X 1200 mm

0,1B
1A,0
24N
Entry to

8
Branch
Existing
Cabinet-
Safe-01
New
Waiting Area
2.85 x 1.82 M

8
Safe-New
Suggestion Drop
Box Box
Cabinet-01

0,1B

8
Branch Manager

10
3.29 X 2.4 M
Pass book
Printing Entry to

0,3D
Existing Existing Existing E-Lobby

0,3D
Locker-01 Locker-02 Locker-03

0,3D

0,3D

0,3D

2B,0
28N
ATM-01
Strong Room

8
Table

8
1500 X 750 mm
5.13 x 2.045 m

0,3D

8
E-Lobby

2D,0
3.20 X 2.40 M

10
03N

12

2B,0
8

32N
ATM-02

1B,0
1B,0

18N
15N
1B,0
Existing

09N
Cupboard Existing Existing Existing

2A,0
Locker-03

8
53N
-New Cupboard-03 Cupboard-02 Cupboard-01

Writing Ledge

0,3D

2D,0
400 mm Deep Low Height Storage

03N
Recycling

12
400 mm Deep Full Height Storage

8
Pune Office :
TRENCH LEGENDS: Mumbai Office :

8
514,Opal Square , 419,City Avenue,
Street No 1, Wakad ,
Wagle Estate,Thane, Mumbai-bangalor
Store Room Lunch Mumbai-400604. Highway,

2.1 X 2.2 M
DESCRIPTION QTY. Maharashtra, India.
Tel-+91 9987263696
Pune-411057
Maharashtra, India.
Area
8 200mm x200mm x50 mm Junction Box 24
RASIKA AJAY UJB
Fire Exit Passage
1.20 M Wide 10 250mm x250mm x50 mm Junction Box 04
12 300mm x300mm x50 mm Junction Box 02 DATA DROP -- 00 01.02.2022

14 350mm x350mm x50 mm Junction Box 00 LOCATION R3

R2
18 450mm x450mm x50 mm Junction Box 00 R1

R0
DISTRIBUTION BOARD ---
NO. DATE REVISION DRAWN CHECKED

TYPE OF RACEWAY CAT-6 CABLE POWER CABLE


Ladies Toilet
1.45 X 1.2 M Passage 0.90 M Wide
100x40--A TYPE 30 DATA CABLES 9 POWER CIRCUITS
P
a
s 82x38--B TYPE 25 DATA CABLES 6 POWER CIRCUITS PROJECT: Interior Works

1200
s
a
Building

N
g 63x38--C TYPE 15 DATA CABLES 3 POWER CIRCUITS
Staircase
[3'-11"]
e CLIENT: Bank of Baroda,
Nalasopara Branch
0.9 M
UPS Room 25DIA COND--D TYPE
Gents W
2.1 X 1.8 M
Block 03 DATA CABLES 1 POWER CIRCUITS
Toilet i
d
e DATA TRENCH

POWER TRENCH

25mm PVC CONDUIT FOR


DATA IN CEILING

P L A N N E R S
A r c h i t e c t s . I n t e r i o r De s i g n e r s . C o n s u l t a n t s
03, Him Parvati, Carter Road No 1, Borivali (E), Mumbai 400066

DWG. NO.: 20220202-BOB NS Interior Layout


N

Raceway Layout

DWGNO
DRAWING: Interior Layout
DRWN BY: CHKD BY: SCALE : DATE :

MAHESH NTS 02/02/2022


THIS DRAWING IS THE SOLE PROPERTY OF PROJECT PLANNERS
USE OF THIS DRAWING FOR ANY PURPOSE OTHER THAN
THAT MENTIONED TO BE DONE ONLY AFTER THEIR PRIOR APPROVAL.

You might also like