Data Sheet
RISH Eine+ DC DPM
96X96/48X96
Measure Control Record Analyze
Data Sheet
RISH Eine+ DC DPM
RISH Eine+ has been designed for industrial applications, which Power Factor Display
frequently require precise and on-site adjustment of the display
The meter can be configured to display power factor also.
range. It measures electrical DC parameters like DC voltage and
DC current. Ambient Temperature Indication
The meter gives an accurate indication of the ambient temperature
in °C and °F.
Applications Auxillary Supply
l Distribution and Control Panels The Auxillary supply 40-300V AC-DC and 20-60V DC / 20-40V AC
l Electrical load monitoring are supported.
l In Laboratories 4 Full digits Ultra Bright LED display
l In Industrial automation 14mm full range display possible of 4 digits having maximum
count - 9999.
Wide Input Range
Product Features Wide range of voltages and currents to choose from.
Low Back Depth (For 96x96 model) Enclosure Protection for dust and water
The instrument has very low back depth (behind the panel) of less Conforms to IP 50 (front face) as per IEC 60529.
than 40 mm. Compliance to International Safety standards
Rescalable Display range Compliance to International Safety standard
The meter is completely programmable and user can easily scale IEC 61010-1- 2010.
the values as per his requirements on-field. Setting for ‘-ve’ sign and
decimal point position is also provided. EMC Compatibility
Function keys Compliance to International standard IEC 61326
Using 2 function keys it becomes easy and convenient for user to Class B
program the meter without any difficulty.
Bent Characteristics
The meter supports bent characteristics. Hence user can configure
the meter as per requirement.
Measure Control Record Analyze
1 M.05/2021
Data Sheet
RISH Eine+ DC DPM
Dimensional Details Technical Specifications
96 mm
Measuring Ranges
96.0mm
Model RISH Eine+ Voltage
Input mV ranges -75...0...75mV, -150...0...150mV
48.0mm Display Area
Input Voltage range -5...0...5V, -10...0...10V, 0...48V,
0...150V, 0...500V, 0...1000V
96mm
Display Area
Max continuous input voltage 120% of Nominal value
Model RISH Eine+ Current
Front View Input Current ranges -10...0...10mA, -20...0...20mA,
4...20mA, -1...0...1A, -5...0...5A
27 mm
Max continuous input current 120% of Nominal value
Accuracy
66.6mm
RISH Eine+ Voltage <0.5% of Display End value ±1 digit
(Input current < 300uA) for V/mV
RISH Eine+ Current <0.5% of Display End value ±1 digit
(Voltage drop < 600mV) for A/mA
5mm
58.1mm Ambient Temperature ±3 °C
6 mm
35 mm Influence of Variations
Side View Temperature coefficient 0.05% / °C, plus
Zero point drift 0.025% / °C
92mm+0.8 92mm+0.8
Display
Type 1 line 4-digit LED display
43.5mm+0.6
Display Count Setting -9999...-10 or +10...+9999 counts
92mm+0.8
Digit Height 14mm
Decimal point position Configurable
Negative Display indication ‘-’
Overload Indication “ - oL - ”
(above 125% of nominal value)
Panel Cutout
Factor C (The highest value applies if calculated C is less than 1,then C=1 applies)
Linear characteristics: Bent characteristics:
Y1 - Y0 X2or C=1
Y0 For X0 < X < X1 C=
1 X1 - X0 Y2
C= Y2 or C=1
1 X0 Y1
X2 1
For X1 < X < X2 C= Y2 or C=1
1 X1
X2
X0 = Start value of input, Y0 = Start value of display ,X1 = Elbow value of input ,Y1 = Elbow value of display
X2 = End value of input,Y2 = End value of display
Measure Control Record Analyze
2 M.05/2021
Data Sheet
RISH Eine+ DC DPM
Installation Technical Specifications
Auxiliary Supply
External Aux 40 - 300V AC-DC
20 - 60V DC/20-40V AC
80 - 300V AC (For 96x96 model only)
Frequency range 45 - 65Hz
Easy Clip - in VA burden < 4.5VA approx. at 240VLN, 50Hz
mounting < 1VA approx. at 24VLN, 50Hz
Reference Conditions for Accuracy
Swivel screw
Reference Temperature 23°C ± 2°C
Auxiliary Supply Voltage Rated Value ±1%
Auxiliary Supply Frequency Rated Value ±1%
96x96 model
Applicable Standards
66.6mm EMC IEC 61326-1:2005
Immunity IEC 61000-4-1 up to 4. Level 3 industrial
Low level
Safety IEC 61010-1:2010, Permanently connected use
5mm IP for water & dust IEC60529
58.1mm Pollution degree 2
Installation category III
48x96 model High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all
Electrical circuits.
Environmental
Operating temperature -10 to +55°C
Storage temperature -20 to +70°C
Electrical Connections Relative humidity 0... 90% non condensing
Warm up time Minimum 3 minute
+
Shock 15g in 3 planes
+ 0...48V Vibration 10... 55 Hz, 0.15mm amplitude
-10...10mA 0...150V
- -20...20mA 0...500V
-1...1A 0...1000V
-5...5A Dimensions and Weight
1 2 3
-75...75mV
-150...150mV Bezel size 96 mm x 96 mm DIN43718(For 96x96 model)
-5...5V
-10...10V 48 mm x 96 mm DIN4371
(48x96 model)
13 14 Panel cutout 92 +0.8mm x 92 + 0.8mm(For 96x96 model)
43.5+0.6mm x 92+0.8mm(For 48x96 model)
LN Overall depth <40mm(For 96x96 model)
Aux Supply <75mm(For 48x96 model)
96x96 model Weight 310 gm. approx.(For 96x96 model)
250 gm. approx.(For 48x96 model)
- +
Approbations
CE, RoHS
- + 1 2 3 4 5 6 7 8 B A
L N
0...48V Aux Supply
0...150V.
0...500V
0...1000V
48x96 model
Measure Control Record Analyze
3 M.05/2021
Data Sheet
RISH Eine+ DC DPM
Ordering codes
Ordering 000000
X 1 X XX X X X X
Information EI99-
Size 96X96 G
48X96 E
Type DC Voltmeter C
DC Ammeter D
Input 75 mV 11
150 mV 12
5V 21
10 V 22
500 V 23
1000 V 24
48V 49
150V 50
10 mA 31
20 mA 32
4-20 mA 33
1A 41
5A 42
Power Supply 40-300V AC/DC M
20-40VAC/20-60V DC D
Accuracy
5
Class Class 0.5
IP Protection Standard IP50 0
Optional IP54 (On request-chargeable) 1
Test Not Required 0
Certificate Required (On request-chargeable) 1
Measure Control Record Analyze
4 M.05/2021
RISHABH INSTRUMENTS PVT. LTD.
Domes c (India): +91 253 2202028/99 | marke [email protected]
Interna onal: +91 253 2202004/06/08/99 | [email protected]
www.rishabh.co.in